HomeMy WebLinkAboutAPPROVED, Polyglass Flat roof SAV-SAP.pdf2/17/2021 Florida Building Code Online
P —Awl.
BCIS Home Log In Wer Registration Hot Topics submit Surcharge Stats & Facts Publications Contact us 6Cl5 S+te Map Lrnis Search
doprQProduct Approval
O
USER: Puhllc user
- Product Approval Menu > Product or AQohcation Search > ggolicauon Lis[ > Application OetalI p FL # FL1654-R27 � ■
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext 242
matpert@polyglass.com
Authorized Signature Maury Alpert
matpert@ polygIass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.corn
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/07/2022
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Standard
Year
ASTM
D4601
2012
ASTM
D4897
2009
ASTM
D6162
2015
ASTM
D6163
2015
ASTM
06164
2011
ASTM
D6222
2011
ASTM
D6509
2015
https:lfwww.floridabuilding.org/pr/pr_app_dtl.espx?param=wGEVXQwlDgvgqu2w%2bnFgUPv2pw6pKxAhNlxQbXaKmD3xgHjyOAYxuQ%3d%3d 112
2/17/2021 Florida Building Code Online
ASTM G155 2013
FM 4470 2016
FM 4474 2011
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from me Code
Product Approval Method Method 1 Option D
Date Submitted 10/02/2020
Date Validated 10/04/2020
Date Pending FBC Approval 10/12/2020
Date Approved 12/15/2020
FL#
Model, Number or Name
Description
1654.1
Polyglass Modified Bitumen Roof
SBS and APP modified bitumen roof systems
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
R22.edf
Impact Resistant: N/A
Verified By: Robert Nleminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Thhtl Party: Yes
Other: 1.) The design pressure in this application relates
Evaluation Reports
to one particular assembly over concrete deck. Refer to the
ER Appendix for other systems and deck types. 2.) Refer to
R27.d f
ER, SeQlon 5 for other Limits of Use. 3.) Refer to R16237
Created by Independent Third Party: Yes
for HVHZ pmdlatkua.
IYEtrg Us:: 2601 Blair none Road renehaeeea 32399 Phoney. 85E.487-1624
The Stan of nndda Is an WEE) empioyen r.,o.mht mm-zar= ..,r undo.:: P1OCrsturmmt:: Aa.eemn,
nrad.a Asia—, s..enn:
rM®®ER®
Credit Card
Safe
hfpslA .floddabuilding.org/pripr app_dd.aspx?pamm-vGEVXQMDgvgqu2w%2bnFgUPv2pw6pIC.AhNlxQbXaK D3xgHjyOAYxuQ%3d%3d 2l2
NEMO j etC.
Certificate of A u th orizotion #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATIONPO
Polyglass USA, Inc. Evaluation Report P9290.02.08-R25
1111 West Newport Center drive FL1654-R27
Deerfield Beach, FL 33442 Date of Issuance: 02/11/2008
(954) 233-1330 Revision 25: 09/30/2020
SCOPE-.
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7" Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION. Polyglass Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FLM) preceded by the words "NEMD(etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the building Official.
This Evaluation Report consists of pages 1 through 5, plus a 94-page Appendix.
Prepared by: ,5«<'ti.,,,`.
Robert J.M. Nieminen P.E. ` �+''A' - '✓'� The facsimile seal a earin was authorired Robert
• M1.!8a`a� Nieminen, P.E. on 09130/220. This does notserve as an
Florida Registration No. 59166, Florida OCA ANE'1983 ....,,
e led roniC311y Signed document.
CERTIFICATION OF INDEPENDENCE:
1, NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018, NEMO ETC, LLC
®MEMO I etc.
ROOFING SYSTEMS EVALUATION:
Product Category:
Roofing
Sub -Category:
Modified Bitumen
Roof Systems
Compliance Statement:
Polyglass Modified Bitumen
Roof Systems, as produced by Polyglass USA,
Inc., have
demonstrated
compliance with the following sections
of the 70 Edition (2020) Florida Building Code through
testing In accordance with the following Standards.
Compliance is subject
to the Installation Requirements
and
Limitations / Conditions of
Use set forth herein.
STANDARDS:2.
Section
Pro a
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2012
1504.6
Accelerated weathering
ASTM G155
2013
1504.7
impact resistance
FM 4470, Section
4.6
2016
1507.10.2
Material standard
ASTM D4601
2012
1507.10.2
Material standard
ASTM D4897
2009
1507.11.2
Material standard
ASTM D6162
2015
1507.11.2
Material standard
ASTM D6163
2015
1S07.11.2
Material standard
ASTM D6164
2011
1507.11.2
Material standard
ASTM D6222
2011
1507.11.2
Material standard
ASTM D6509
2015
3. REFERENCES:
inift
Egam
Reference
Date
Entity
Egam
Reference
Date
ERD(TST6049)
Ph,lrah
P10490.1008.2
10MO/2C08
FM (TST1e67)
FM 4470
3006115
05/02/2003
ERDITST60a9)
FM 4470/4474
P33760.09.09
(XVIO/2009
FM (TST1867)
FM 4470
3012322
07/29/2002
ERD MT6149)
FM N70/404
P13770.09.09
09/10/2W9
FM (TST1867)
FM"M
MU692
OB/OS/2003
ERD(nnat39)
FM4470/4474
P30540.11.09A1
11/30/20(9
FM (TST1867)
FM"M
W14751
08/27/3003
ERD mT(M9)
FM 4470/4474
P305SOA2.09
1rAo/20U3
FM (TSTla67)
FM""
3007ll0
01/13/2004
ERDITSr6049)
PhpinB
P33960.12.10
1WO12010
FM OTST1867)
FM470
3019317
O6/30/30%
END ma'SU91
FMMID/W4
P33970.03.11
03125/20II
FM(TST1R6q
FM 44W
3020703
07/30/2W4
EAU (I5T6019)
Phpinh
P3759003.133A
03/06/2013
FM (15T1867)
FIVIUM/4474
301032
01/31/7W6
ERD (IST6M9)
FIA 44AV.74
P39(a9003.13
f13/M/2013
FM InT1867)
FM4470/M4
30233U
'upon.
ERD OST6M9)
Po aak
P3759001133R1
M/76IM13
FM(T5r1867)
FM4MV.74
30245%
0/23PM
ERD (T5T649)
P"Iab
P375%,03.133M3
0/01/2013
FM TST1867)
FMN70/4474
3023458
0/18/2W6
ERD p5T6M91
Ph"I.6
P37590.07.132
07/01/2013
FM991867)
FM4470/4474
3030668
09/12/2007
ERD IRT6M9)
Physhats
P1759003.135 R1
07/01/2013
FM ITStt867)
FM 4470/N74
3032172
M/12/2009
ERD(MW491
Physlob
P3759007.131
07/02/2013
FM INTI867)
FM 400/4474
3M9631
M/21/2014
FRD(MIK49)
FM4MV.74
P4163008,13
011/06/2013
FM MT1867)
FIAU70/4474
30M29
OR/02/2017
ERn(MIND19)
Physicals
"59,10.09,23
09/04/M33
MEMO(TST6M9)
Criticality
4sALY61aWID618
M/23/2018
ERD (TST6M9)
Physials
P44370.10.13
1O/M/2013
MEMO ITST6%
FM N74
4LHY4LadV.WL
08/21/2018
ERD(R 6M9)
Physirab
P39520.09.162
03/1112014
MEMO(M6019)
G Iity
10/03/20M
ERD(TST6019)
FM 4070/4474
5[b160.11.14
IV10/2014
Pnoorr TW49)
A5FM Db9>
4SftWLmLiLiax
I1AWi018
ER0(TST6049)
PhSslols
P454405C.03.IS1
03/3tAms
KEW(WOUX91
/i57RF 06164
4SHWL0]Ltva3
11/11/2018
DU)mT6019)
Phials
SC5170.05.15
95/08/2015
MEMO (TSTW49)
FM 4474
44PLY41a W3.11.16
11/28R018
ERDm T6M9)
FM WOO
SCW95.05.15
0119/2015
MEMO(MG(49)
1M4474
4LPLY416ro3 M.L9
OIAW019
ERD(TST60a9)
Physimis
SC5170.1115
12/29/2015
MEMO (TSr6049)
ASTM M163
4SITY4L.Uiu39A
01/24/2029
PRE)(ISTW49)
FM r1AVU74
A945515
N10112016
NEMOIRT6M9)
ASTM D6162
41H1.1.2Ia.
01/25/2019
ERD(TST6W9)
FM 4470/M74
FLYG5C8905.05.16.1
05/17/2015
MEMO (TST6049)
FM 4474
46HYGIaM.WISA
M/OW019
ERD MT6049)
FM OM/4474
PUG-SC8905.05.162
05/17/2016
MEMO (TST6449)
ASTM 0622E
450'.UMi.D541c
0/20/2029
DonST60u))
FM 4470/4474
.1tiWi5.O7.I6M
09/23/2016
NEMO(TSrW49)
ASTM ('6222
4SPLYG 18N205140
M/20/2019
can ITST60a9)
ULIW7
PLYGSCII@5.10.16
10/12/2016
NEM0hST60491
ASTM M163
4SF UtML05]4M
UUM/2019
ERD(TST60u?)
FM"M/4474
PLYG-SC11475.16
11/17/2016
NEMO(TSTW491
ASTM D6164
4SH UMMS.HM
OsaW019
ERD mT6049)
FM 4AV"74
MYGX]3235.01.17
01137A017
MEMO(TSTW49)
GNaOty
45HYGI.Owi9A
07/17/2029
ERD(I5TE019)
FM 470/474
PLYG5Cll920.05.37
05tVVW17
MEMO (1316849)
ASTMD614
4I.OrO]LW.I.,
09/06/2019
ERDITST11294)
FM 47 4,174
HY6{RU olasilt
05/30/W37
NEMODRW491
ASTM Must
41HYbIBOl21 ,.
09/OW2019
ERD(TST11294)
FM 44ID/N74
HY4CmMsar1
OS/30/2017
MEMO (115116049)
FM 474
uHtt.2o6wuS
08/2WZD20
ERD(1316049)
FM 470/474
PLYG-SC13MS05A7
05/30/2017
PRO muriann
Physiob
PUS-062-02-01
12/01/2007
ERD(TSTW49)
FM 470/474
PLYGSCI5760.011.17
09/31/2017
PRI p5i58781
Physirab
PU5A-061-02-02
01/28/20011
FM RS71867)
FM 470
2MA7.AM
08/04/1934
PRO TST5976)
Phys b
PUSA-0 02-02
02/27/2009
FMRST1867)
FM 4470
003A3.AM
M/M/1997
PRI (TST58781
Phy—ts
PUSA0620242
12/04/2011
FM ITST1867)
FM 4470
2WAOAM
12/23/1998
PRO mrTS872)
TA5114
PUSH 188L201
02/08/2017
MEMO ETC, LLC EValUatlon Report P9290.02.013-1125
Cervical¢ P/AutAarlratE4 F32455 7T" EDITION (2020) FaC NON HVHZ EVALUATION FL1654-1127
POlyglass ModlOed Bitumen Roof Systems R.W.n 25: 09/30/2020
Page 2 of 5
Entity
Exam
Reference
Date
Entity
EXdm
FM (TSri867
FM 4470
2D5A9.,1M
o6/ 22/1999
PRI IT575.18)
TA5114
FM(TSrl86T)
FM 4470
3NE646
O1/04/2000
PRI(TST5878)
TASll4
FM 0ST1867)
FM 4470
3W1331
O1/25nM
PRI(TST5878)
TM 114
FM (T5r1867)
FM M70
3W13M
02/1512000
PRI Mn`5878)
TAS 114
FM M867)
FM.70
30.V857
W/1212000
MD(CER1592)
HVHZ
FM".67)
FM.70
3W4D31
01/12/20.tl
MD(CER1592)
Pro'. lo, Rev.
UL(m.25) Donn, Cuuml
ONEIMI)Jetc.
Reference
Date
PUSAd88- 01
02/OB/201]
PUSAIW-@-03
02/D8/2017
P=5 2@-02-01
05/17/2017
PU54S@-024o
05/0/201?
Vanous NCuo
wdon
1 1123
l0/1V2010
Se k Confim
03/13/2018
F
This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass
USA, Inc. published Installation instructions and the Limitations / Conditions of Use herein.
TASLE 1: ROLL -GOODS FOR MODIFIED BITUMEN ROOF SYSTEMS
Type
Product
Materiel Standard
Plant(s)
Reference
Type
Grade
Polyglass G2 Base
ASTM D4601
II
N/A
AL
Polyflex SA Base
ASTM D4601
II
N/A
FL
Base Sheets
Elastobase SA
ASTM D4601
II
N/A
PA
Elastovent
ASTM D4897
N/A
N/A
PA
Polyglass Base
ASTM D6509
N/A
N/A
FL
Pol bond
ASTM D6222
I
S
FL
APP, Smpath-Surface
Membranes
Polyflex
ASTM D6222
I
S
FL
Polykool
ASTM D6222
1
5
FL
PolybondG
ASTM D6222
I
G
FL
PolyflexG
ASTM D6222
1
G
FL
Polyflex G FR
ASTM D6222
I
G
FL
PDlyfreskoG
ASTM D6222
1
G
NV
APP, Granule -Surface
Polyfresko G FR
ASTM D6222
1
G
NV
Membranes
Polynex SA P
ASTM D6222
I
G
FL, TI(
PDlyflex SA P FR
ASTM D6222
I
G
TX
Polyfresko G SA
ASTM D6222
I
G
NV
PolyfreskD G SA FR
ASTM D6222
I
G
NV
Elastoshield HT
ASTM D6162
III
S
FL
Elastobase
ASTM D6163
I
S
FL
Elastoflex V
ASTM D6163
I
S
FL
Elastoflex SA
ASTM D6163
I
S
FL, PA, TX
Elastoflex SA V FR
ASTM D6163
I
S
FL PA, TX
SBS, Smooth -Surface
Elastoflex SA V Plus
ASTM D6163
I
S
FL,TX
Membranes
Elastoflex SA V Plus FR
ASTM D6163
I
S
FL, TX
Elastobase P
ASTM D6164
I
S
FLTX
Elastoflex SA Base HD
ASTM D6164
I
5
PA,TX
Elastoflex 56
ASTM D6164
1
5
FL
Elastoflex S6 HP
ASTM D6164
II
5
NV
Pol reflect
ASTM D6164
1
5
FL
Elastoshield AT G
ASTM D6162
III
G
FL
Elastoshield AT G FR
ASTM D6162
III
G
FL
Elastoflex V G
ASTM 06163
1
G
FL. PA
Elastoflex V G FR
ASTM D6163
1
G
FL, PA
SBS, Granule Surface
Elastoflex SISG
ASTM D61M
I
G
FL PA
Membranes
Elastoflex S6 G FR
ASTM D61M
I
G
FL
Elastoshield TSG
ASTM D61M
I
G
FL TX
Elastoshield TS G FR
ASTM D61M
I
G
FL TX
Elastoflex SAP
ASTM D6164
I
G
FL TX
Elastoflex SA P FR
ASTM D6164
I
G
FL TX
NEMO ETC, LLC Evaluation Report P9290.02.08-R25
CenlAm2e o7AuMonmton#32455 7m EDITION (2020) FBC N0&HVHZ EVALUATION R16S4-R27
Polyglass Modlfled Bitumen Roof Systems Revision 25: 09/30/2020
Page 3 of 5
ONEMIDIetc.
K. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Niernmen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone Jurisdictions (i.e., Broward and Miami -Dade
Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning
the use of foam plastic insulation.
5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements
and limitations regarding edge securement for law -slope roofs.
5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations.
5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for
withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing shall be in accordance with ANSI/SPRI FR-1 or Testing Application Standard
TAS 105.
5.6.2 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing
deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface
conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-
1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on
mock-ups of the proposed new roof assembly.
5.6.3 For banded insulation or membrane over existing substrates in a recover installation, the existing roof system shall
be capable of resisting project design pressures on Its own merit to the satisfaction of the Authority Having
Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data
Sheet 1-52 or Testing Application Standard TAS 224.
5.7 Refer to Appendix l for system attachment requirements for wind load resistance.
5.7.1 "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been
applied). Refer to FBC 1609 for determination of design wind loads.
5.7.2 For mechanically attached components or partially -bonded insulation, the maximum design pressure for the
selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with
FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are AN51/SPRI WD3, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137.
Assemblies marked with an asterisk- carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29 (February 2020) for Zone 2/3 enhancements.
5.7.3 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly
shall meet or exceed critical design pressure determined In accordance with FBC Chapter 16. No rational analysis is
permitted for these systems.
5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are
produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report.
NEMO ETC, LLC Evaluation Report P9290.02.08-11C25
Cmljmre erAulhN eb #32455 7' EDMON I2020I FBC NONAVH2 EVALUATION FL1654-R27
Paly8lass Modified Bitumen Reof Systems Revision 25: 09/30/2020
Page 4 of s
ONEIVIOletc.
Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published
installation instructions, subject to the Limitations / Conditions of Use noted herein.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named CA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CA, requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625: (414( 248-6409, karen.buchmann@ul.com
THE 94-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
NEMO ETC, UC Evaluation Report P9290.02.08-1125
Ce,O➢ce. fA.ohoivaa.a 11455 Y"EDIn0N(2020)Fee NON-HVHI EVALUATION F11654-1127
Polyglass Modified Bitumen Roof Systems Revision 25: 09/30/2020
Page 5 of 5