-�- wrightsoft® � � Date: Jul 13, 2017
Entire House . By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM
For. 179 VINDALE AVENUE
FT. PIERCE, FL
Notes:
FILE ���Y
L I...i'E COUNTY EUILDING DIVISION
RI vi-",TD FOR CW-1PLl4NCE
,
Design
•
Weather. Fort PierhF�r�'li�PA-
Winter Design Conditions
Summer Design Conditions
Outside db
42
of
Outside db
90
°F
Inside db
70
°F
Inside db
75
°F
Design TD
28
°F
Design TD
15
°F
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating
Summary
Sensible Cooling Equipment Load Sizing
Structure
19837
Btuh
Structure
25212
Btuh
Ducts
7394
Btuh
Ducts
11106
Btuh
Central vent (29 cfm)
897
Btuh
Central vent (29 cfm)
481
Btuh
Outside air
Outside air
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
28129
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipmelif sensible load
34959
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
2335
Btuh
Ducts
3024
Btuh
Central vent (29 cfm)
1218
Btuh
Heatingg
Coolingg
Outside air
Area (ftz)
1476
1476
Equipment latent load
6577
Btuh
Volume (ft3)
14580
14580
Air changes/hour
0.45
0.23
Equipment total load
41536
Btuh
Equiv. AVF (cfm)
109
56
Req. total capacity at 0.70 SHR
4.2
ton
Heating Equipment
Summary
Cooling Equipment Summary
Make
Make Goodman Mfg.
Trade
Trade GOODMAN; JANITROL; AMANA DISTI...
Model
Cond GPC1448M41A
AHRI ref
Coil
AHRI ref 7513341
Efficiency
100 EFF
Efficiency 11.0 EER,
14 SEER
Heating input
7.4
kW
Sensible cooling
32550
Btuh
Heating output
25133
Btuh
Latent cooling
13950
Btuh
Temperature rise
15
of
Total cooling
46500
Btuh
Actual air flow
1550
cfm
Actual air flow
1550
cfm
Air flow factor
0.057
cfm/Btuh
Air flow factor
0.043
cfm/Btuh
Static pressure
0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.85
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
. Q * wrightsoft- RightSuite® Universal 2017 17.0.14 RSU08101 2017.1u1-13 14:ge 1
�� Page 1
...serslQuick Calcs\Documents\179 VINDALE AVE..rup Calc = M.18 Front Door faces: E
-t wrightsoft Right-J@"worksheet �-� Joe=
Entire House Date: Jul 13, 2017
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOLCOM
1
Room name
Entire House
179 VINDALEAVE.
2
E)q,)osed wall
174.0 ft
174.0 ft
3
Room height
9.0 ft d
9.0 ft heat/cool
4
Room dimensions
60.0 x 27.0 ft
5
Room area
1620.0 ft2
1620.0 ft2
Ty
Construction
number
U-value
(Btuhlft-"F)
Or
HTM
(Btuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
12B--0s.w
1Ac1om
1Aclom
0.097
1.270
1.270
n
n
n
2.72
35.56
35.56
258'
XT7
34T7
W
8
16
495
0
0
. 1344
267
569
1277
261
556
540
8
16
499
0
0
1344
267
569
1277
261
556
IAclom- -.
1.270
--n
35.56
3477
- 22
0
_ 765
.748
22
- 0.
_ 765
748
yl--
IG
11
1213-0sw
0.097
a
2.72
2.58
243
232
631
5%
243
232
631
599
1Ao1om
128-0svv
1Aclom
1.270
A097
1.270
a
s
s
35.56
2.72
35.56
86.40
2.58
34.77
_ 11
'540
12
_ 1
456
12
382
1239
427
929
1177
417
_ _ 11,
540
12
.1
4-%
12
382
1239
427
929
1177
417
1Aclorn
1Aclomd
1.270
1.270
s
s'
35.56
-35.56
'34`.77
• •34.77
11
41
11
_ 41
382
1451
374
1419
11
41
11
41
382
1451
374
1419
_
1qJ
11DO .-
12B-0sw
0.390
0.097
_- s
w
. ,. _ 10.92
2.72
11.31
2.58
._-. . -.20
243
20
195
223
530
_ . .231
503
20
243
. , 20
195
'. .. 223
530
231
503
�-G
1Aclom
1.270
w
35.56
91.12
48
0
1707
4374
48
0
1707
4374
--
C
16A-11zd _
0.081
2.27
' 5,87
'1620
1620
. -:iGM
9513
1620
1620
. 3674
9513.
F
-
19A-7bstp
0.099
-
1.78
0.95
1620
1620
2883
1544
_
1620
1620
2883
15"
6
c)AED extusion
369
369
Envelope loss/gain
16472
24291
16472
24291
12
a) Infiltration
3365
921
3365
921
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
19837
25212
19837
25212
Less e:Qemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
19837
25212
19837
25212
15
Duct loads 1
379/6
449/6
7394
11106
371/6
441/6 1
7394
11106
Total room load
27231
36318
27231
36318
Air required (cfm)
1550
1550
1550
1550
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrigittsOft" Right -Suite® Universal 2017 17.0.14 RSU08101 2017.1u1 13 1 Page 1
...sers\Quick Calcs\Documents\179 VINDALE AVE..rup Calc = MJ8 Front Door faces: E
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.