Loading...
HomeMy WebLinkAboutEngineeringP. L 1 17"-10" L 2'-1" O.H. 2'-1" O.H. X m m o� 17'-10" 17 KP T IEZSE PLANS AIND ALL M-POSED WORK ARE SUBJECT TO ANY CORRECTIOI4S RIQUIRED DY GELD INSPECTORS THAT MY 81, NEr0FS10ARY IN 0RDEPd T0. ; 3 COMPLY �e�H � z � fsPPLICAftCOPES." I t �0.11 12' k too E * No 41111 :•* :W: �:• STATE F CV 06-27-2017 ��i�Fs�;•. 0•R �•..•�C�;�8002 PENSACOLA ROAD A;FORT PAGE ����, PIERCE, OF 3 FL File Copy "i IFS tt I. JUL 13 20W PERMilliTIING St. Lucie COUnty, (=L CONCEALED FASTENERS OR AATT'ACHME ARE THE RESPONSISILfiY OF THE OOP,1TRACTOR OF r9ECOM S T. rLITC DIVISION REVIEWED FOR C-`TLF4NCE REVIE, ,"ZvT 2=4 DATE PLANS AND P—EY—NU T -4 -LJST BE KEPI' ON JO^ 1 12' ® COPYRIGHT 2017 - FARLEY ENGINEERING, LLC 1X3 SCREEN CHANNEL W/ 1�4' DIA. TAPCONS ® 24 O.C. 2X2X3 CUP ANGLE (4) #14 EACH SIDE & (1) 1/4" X 2" EMBED TAPCON EA. SIDE L2X2X2X1/4 ANGLE CUP W/ (4) #14 TEKS EACH SIDE OF POST 3/8" DIA. X 3" MIN EMBED 2" /— TAPCON EACH SIDE e o • / BRICK PAVERS � I ' 0 0 12" X 12' OR 9"X16" ------ --� W/ (2) #5 CONT. STRIP FOOTING (2) #12 TEKS �' T EACH CLIP RECEIVER CHANNEL TYPICAL RAIL 2X3XO.05" CHAIR RAIL TO POST PURLIN (2X3) —X 2X3 W/ 1X3 —� 1 i RECIEVER WX.125"X3" CHANNEL ANGLE W/(3) #14 TEKS (6) TOTA; 2X POST PURLIN TO POST ROOF BEAM 2X3 W/ 1X3 —� 2X2X.125"X3' ANGLE W/(3) #14 (4) #14 TEKS TEKS (6) TOTA; e 2X POST 2X2X.125" E— W/(2) #14 TEKS ROOF BEAM TO POST 1X2 SCREEN CHANNEL W/ 114' DIA. TAPCON— ® 24 O.C., (2' EMBED) 2X2X.125" ANGLE J EACH SIDE W/(2) #14 AND 1/4" XK2" EMBED TAPCON TYPICAL ADD (1) 2X2 ANGLE EACH SIDE TO SPANS OVER 30' ROOF BEAM TO MASONRY 1/4" LAG 0 24" AT GUTTER 20 PURLIN • 2� yIL • � ,09" PLATE = NEACH M TEKMBE TIP. MEMBER ANS OVER 32' jj14 TEKS) POST X.05' BRACE K— BRACE ALTERNATE FASCIA SHIM RECIEVER CHANNEL5" SUPER GUTTER W/ (2) #14 TEKS PURLIN @ SUPER GUTTER 1X5X1/8X8" EACH STRUCT. FASCIA SM W/ (3) 1/4' X 3" LAGS �] (3) #12 TEKS__ '! �L— SHIM 5" SUPER GUTTER 2X2SIDE W/ (4)"#14GLE TEKSACH OVER 36" SPAN USE (3) 3/8" X 3" LAGS BEAM @ SUPER GUTTER 2X3X.05" BRACE 2X3X.05" RAIL .09" PLATE ' 0 0 TYP' (4) #12 e o TEKS o ,`,/111111 U����, �j (2) #12 TEKS TYP. EACH MEMBER ��•.••.••• �j C E N s� •� i (SPANS OVER 32' USE //14 TEKS) r POST No 40111 • .*r • • /= 2X3X.05" BRACE . STATE of : 0�`'• o6-27-2017 K—BRACE ALTERNATE AIt, 0 R 1 �.•�C��` SLYE RESIDENCE 8002 PENSACOLA ROAD F IEORF L POT AGEE, 7" 0000 0 1/8" ANGLE BRACKET W/ (9) #14 X 3/4" SMS TO WALL MEMB. 1/8" STAINLESS STEEL CABLE DOUBLE COMPRESSION SLEEVES 5/16" EYE BOLT WELDED CLOSED W/ DOUBLE NUT DOUBLE SLEEVES 1/8" CABLE N 5-5/8" X 1-1/4" X 1/8' (2) 3/8" SLEEVE FLAT BAR ANCHOR CABLE BRACE ALTERNATE ROOF BEAM 2X3 RECEIVER CHANNEL —1 r 2X3 W/ 1X3 2X3— (2) #12 TEKS EA. SIDE TYP. (6 #12 TOTAL EACH END) WIND BRACING (DIAGONAL AT ROOF) COPYRIGHT 2017 — FARLEY ENGINEERING. LLC 1X5X1/8X8" EACH®��! BM W/ (3) 1/4" d X 3" LAGS #14 TEKS 0 12" O.C. (3) #12 TEKS� 1X3 SCREEN CHANNEL W/ 1�4" DIA. TAPCONS 2X CARRIER BEAM ROOF BEAM 2X2X.125" ANGLE 0 24 O.C. TO COLUMN (2) #14 TEKS 2X2X3 CLIP ANGLE (4) #14 EACH SIDE E—(6) #14 X 2" TEKS & (1) 3/8" X 2" EMBED TAPCON EA. SIDE X 3/4- ANGLE CH BEAM TO BEAM CONNECTION W/ (4) #14 ANGLE CLIP W/ (4) #14 TEKS EACH SIDE SIDE OF POST 2X2XW/ (4) SIDE W/ (4) 3X3X1/8" ALUM 1/4" DIA. X 3" MIN EMBED #14 TEKS COLUMN 2" TAPCON EACH SIDE eoe 15" TYP. (1) 3/8 " X 2" 2X2X3 ANGLE W/ 2x7 TO 2X10 BEAM 0.09" 4" CONCRETE SLAB EMBED TAPCON (4) #14 X 3/4" TEK EACH SIDE PLATE i EACH SIDE /!��#5 CONT. X COLUMN / CARRIER SECTION 2X3X.09.5" SCREEN CHANNEL TYPICAL t:=X.125" DIA. BOLT ANGLE SPANDRELSSIDE W/(2) TEKS F BEAM BEAM TO SPANDREL 2X3 PURLIN 2X2X.05" RECEIVER CHANNEL W/(2) #12 TEKS ROOF BEAM PURLIN TO ROOF BEAM (2) 2X2X.125" ANGLE AT ALL BEAM CONN. GUTTER STRAP GUTTER (2) #14 TEKS TYP. E—FASCIA (12) TOTAL PER BEAM 0 GUTTERI.F_ MIN. PURLIN OR I -,I I ROOF BEAM BEAM & PURLIN 0 GUTTER ,`ttttlll U 11 #�, � .••......, RAF' , \C ENS• •.,� • % No 401 1 2 • .. . STATE OF .'� Oin I�,VS• •••••••• % A L FOR SMB'S: #14 TEKS 0 18" O.C. A4 TEKS MIN. EACH 1DD t4) MORE FOR SPANSSIDE 33 FEET (12) #14 TEKS AT 2X6 OR SMALLER GUSSET AT RIDGE & MANSARD 1/4" LAG BOLT W/ 1-1/4- FENDER WASHER. 3" COMPOSITE ROOF PANEL 1'-8" MAX. SUPPORT BEAM (CARRIER BEAM CONNECTION' SIMILAR) 2X2 X 5" X .125" ANGLE W/(5) #14 TEKS EA. SIDE 2X2 X .125" ANGLE W/(3) #14 TEKS EA, SIDE FOR COMPOSITE ROOFS 1/4" LAG BOLT W/ 1-1/4" FENDER WASHER 0 12" O.C. 0 BEARING AND 24" O.C. 0\ NON BEARING. FOR PAN ROOF W/ 3/4 #A UMINUMLPAN WASHERR 12" PANEL CAULK ALL EXPOSED SCREW HEAD AND WASHERS OR USE NEOPRENE WASHERS WITH RUBBER GROMMETS ROOF PANEL TO BEAM RECEIVING CHANNEL W/ #12 X 3/4" SMS 0 10" D.C. TOP AND BOTTOM 3" COMPOSITE ROOF PANEL EXISTING ROOF 1/4" X 2-1/2" LAG 0 12" O.C. PROVIDE SHIM IF FASCIA SQUARE CUT ROOF PANEL TO FASCIA 06-27-2017 THICKENED SLAB EDGE GENERAL NOTES: ENGINEER IS NOT RESPONSIBLE FOR WATERPROOF CONNECTIONS TO GABLES/WALLS ALUMINUM FASTENERS SHALL BE OF ALLOY 2024-T4 MINIMUM THICKNESS SHALL BE 0.04" EXTRUDED ALUMINIMUM BEAM, GUSSET PLATES, POSTS, PURLINS, ANGLES AND CHANNELS SHALL BE 6005-T5 CONCRETE SLABS SHALL BE 2500 PSI CONCRETE MINIMUM ALL TAPCONS SHALL BE 5/16" MIN. UNLESS NOTED OTHERWISE. ALL DOORS SHALL BE SELF CLOSING AND SELF LATCHING DESIGN CRITERIA WINDLOAD - 150 MPH PER 2014 FBC ASCE-7-10 EXPOSURE - "B" (EXPOSURE HAS BEEN VERIFIED) RISK CATEGORY - 1 MEAN ROOF HGT. - 15' COPYRIGHT 2017 - FARLEY ENGINEERING, LLC