Loading...
HomeMy WebLinkAboutProduct Approval Gulf Coast Supply, 0 W , ** �00' �im W...\ . . Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC 26 Ga. GulfRibTM Roof Panel over 15132" Plywood Florida Product Approval #11651.22 R2 17 Florida Building Code 2014:ST. LUC!E CLLTy BLrII.nr!'C Njj,'TSI0,,v Per Rule 61 G20-3 _RFVIEWED POR CO?VIPI ` / n THESE PLANS AND ALL PROPOSED WORK Method: 1 —D r'VEAD B 1 G�lZM ARE SUBJECT TO ANY CORRECTIONS DATI; MjK( BE N CE SARISLD INSPECTORS THAT ]PLANS AND ER ST BE N JOB MAYBE NECESSARY IN ICAB i 0 Category: Roofing COMPLY WITH ALL APPLICABLE COgBA' OR NO INSPECTION WILL BE MADE. Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(1)(d) NON HVHZ CONCEALED FASTENERS OR ATTACHMENTS Product Manufacturer: ARE THE RESPONSIBILITY OF THE Gulf Coast Supply & Manufacturing, LLC. CONTMCTOROFWORD 14429 SW 2nd Place, Suite G30 % ����+�'' Newberry, FL 32669 ; %%SOP ..... . , . • 1GEN Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 N. sF •.ti * : No. 7551.9 STATE OF •O• OR �0NA LAPI" EN o.6130� 15 ti 3HT 3RA Tn zu\`\�-. Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: GulfRibTM' 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/a" Major Rib at 9" O.C. Panel Fastener: #9-15x1.5" HWH with sealing washing or approved equal '/a" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 75/3z" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2014. Design Uplift Pressures: FL# 11651.22 R2 • JUNE 15, 2015 Table "A" mums;TotalGUpliftDesignPr�essure692p 15925 psf "> NMax Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- 2.5"6.5"-2.5 "-6.5" � ., . �, Fas�te"ner Patfern Sp c g 2A C CAM Design Pressure includes a Safety Factor = 2.0. l Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-04 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST 5328) Report No. 117-0062T-07A, B, Dated 02/19/2007 2. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) ® Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. FL# 11651.22 R2.1UNE 15, 2015 ... 0 4N n, W r...\ - � Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. r ' . /m '00,/\ ENGINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32" Plywood „3 [3uildings,kaving ayRoof;IUleaHeight00 s, RoofSlop 2 /12 �r 'f% }w /12>' GaE?I,e oHlp > r u,wtf,1 Roof; 1NInd Speeds 180mph, :ExposurexC Rlsk. Cafegory 11 Enclosed 8ullding based Florl= gilding Gil ee 20 4,, ' on 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN. Penetration) (MIN. 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER 'ON CENTER SPACING SPACING SPACING SPACING SPACING) SPACING "ZONE 1... °#9 15X1 5, '°f PIywOOd'"'Tyr�24 24EYPE 1� yySPAC'IING �'uJvs .,�^ 24 TYP�E 1QJ24 TYPE 1 24- TYPE 1, 24', TYPE T �24 1s �TYPEy1 ,1 �.+t'"fiib^. r7YPE N'e:_SS^":.7°• 11's :�3 ZONE 2 #9-15x1.5" Plywood 24!', TYPE 1 24"NN,,1 TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 24", TYPE 1 12", TYiPEJ2y ZONE 3 #9 �!�L�ST4'h'�'S.:,. 1. 24"., TYPE 9 12 TYPE 2 f 12", TYPE 2 =41 ti�WVbw 7@ TYPE2: ! 15x�15,P '4T�YPE n'd� 1.) PANEL DESCRIPTION: GULFRIBTM, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4" TALL. 2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) PLYWOOD DECKING: MIN. 15/a2" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 uto txnnr c `c ZONE 3 jrj J /—i\ /—-------------/ —� RIDGE ZONE /1II \\\\\I / —\ Note: Dimension (a) is defined as 10% of the minimum width of the building or 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be 4a less than either 4% of the minimum width of the building or 3 feet. TYPE 1 FASTENER PATrERN ZONE 2 GABLE ROOF TaT --- ----------------- —RIDGE i-----—---------; a — — — — — — — — a I ZONE N.\---------------------� OZONE 3 EAVE FL# 11651.22 R2 •1UNE 15, 2015 At Cont. Tape Seal for use on Slopes less than 3:1 49-15 x 1-1/2' w/Sealer Washer @ 24' O.C. Max. Cont. Tape Seat for use on Slopes less than 09.15 x 1-1/2' w/Seater Washer @ 12' O.C. Max.