HomeMy WebLinkAboutConstruction PlanGEN..AL NOTES 16515 ( ULT ) A. Wood: I. All lumber on or below grade shall be ACQ Pressure Treated Southern Yellow Pine 02 Grade (Fb = 1,000 pet min.) 2. All lumber above grade (non -decking) shall be Southern Yellow Pine 02 Grade 3. All framing lumber shall be hem -fir 02 grade or equivalent 4. Wood structural panels shall be Ii" Min, thickness, exposure 1 structural sheathing 5. In all instances where aluminum comes Into contact with pressure treated wood, prov'de dielectric separation B. Concrete (See Site Preparation for Existing Concrete) C. Masonry: N/A D. Aluminum I. All structural aluminum conforms to the minimum requirements of 6005 - T5 for alloy and temper: 2. All structural aluminum work conforms to "Part I -A - specifications for aluminum structures - allowable stress design: or "Part 1-5 - Specifications for aluminum structures - building load and resistance Factor design" of The Aluminum Association, Inc. Seventh Edition, Effective January 2000 3. In all instances where aluminum comes into contact with steel, or pressure treated lumber provide dielectric separation E. Glass I. Glass units consist of two panes of 1/8" thick tempered glass with an argon fill 2, Glass conforms to ASTM E1300 3. All clear Argon roof glass has the following min, properties: Ashrae Winter U Value = .25 Ashrae Winter R value = 4.0 Solid Wall Panels I. Aluminum panel skin is Alloy 3105 - 1­1I4/1•125 and is 0.024" thick min. 2. Panel Core Foam is Preformed Expanded Polyeterene Board (EPS). F. sealant .. 1. All sealant conforms to TT - S - 001543 - A, TT - S - 002306, ASTM C 1320 Type S, Grade NS, Glass 25. Sealant to be used for structural adhesion 4 to prevent water Intrusion, G, Gaskets ,. 1. All gaskets are co -extruded and are non -migratory. H. Fasteners I. All lag bolts shall conform to stainless steel type 300 18 - 8, with standard flat washer unless manufacturer galvanized bolts specifies for use with ACQ pressure treated wood 2. Hex bolts has be ASTM A325, plated with standard flat washers and nuts 3. All concrete screws shall be ia" x 2 Itt" min., Simpson, HiM, Rawl, Tapcon, Redhead, Dynabolt, or approved equal 4. All metal ties and associated accessories shall be hot dipped galvanized 5. All lag bolts shall have a minimum embedment of 8x bolt diameter Into structural framing (G = .42 min.) 6. Lag bolts and screws into wood framing shall be provided with pilot holes having a diameter not greater than 10 percent of the thread diameter of the bolt or screw. All lag bolts and screws shall be inserted in pilot holes by turning and under no circumstances by drIAng with a hammer. 1, All expansion anchors shall be designed in accordance w th the specific manufacturers requirements and allowable loads and shall only be applied in conditione acceptable to manufacturer 8. All fasteners connecting aluminum components or pressure treated lumber are stainless steel type 300 18 - 8 unless manufacturer galvanized bolts specifies for use with ACQ pressure treated wood, or otherwise noted on plane 9. All fasteners shall comply with ASTM A153 10, All connectors shall comply with ASTM A653 Glass G - IS JOB SPECi. IC NOTES GENERAL NOTES I: CONSTRUCTION TO FOLLOW THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2014 5TH EDITION 4 WIND CRITERIA PER ASCE 1-10, 2: NO EGRESS OPENINGS FROM ANY BEDROOM / SLEEPING ROOM HAS BEEN COMPROMISED BY PROPOSED SUNROOM 3: ELEVATIONS ARE REPRESENTATIVE ONLY SUNROOM CATEGORY "II" REQUIREMENTS I. PER AAMA/NPEA/NSA 2100-02 THIS STRUCTURE MEETS CATEGORY "II" REQUIREMENTS 2: CATEGORY "II" SUNROOMS PER AAMA/NPEA/NSA 2100-02 SECTION 1.0 GENERAL REQUIREMENTS FOR SUNROOMS SUBNOTE 1.1 ELECTRICAL REQUIREMENTS SUBNOTE 1:11 : (EGRESS LIGHTING REQUIRED ONLY) SUBNOTE 1.1.2 = EXCEPTIONS: CATEGORY II SUNROOMS ARE EXEMPT FROM REQUIREMENTS FOR RECEPTACLE OUTLETS, ELECTRICAL NOTES I: ANY ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2011 NATIONAL ELECTRIC CODE 4 CONFORM WITH THE FBC 4 ALL LOCAL CODES 2: ALL ELECTRIC COMPONENTS SHALL BE TIED TO EXISTING ELECTRIC SERVICE 4 PANEL SPARES 3. PLACEMENT OF ALL. ELECTRIC COMPONENTS BY LICENSED ELECTRICAL CONTRACTOR 4. EGRESS LIGHT REQUIREMENT: NEW LIGHT 4 SWITCH OR EXISTING LIGHT OR SOLAR POWERED LIGHT MAY BE USED) S. ENGINEER OF RECORD NOT RESPONSIBLE FOR ELECTRICAL WORK. I. Site Preparation r 4 " ` �� I. Foundation eyetems must be placed on clean, compacted, termite -treated fill/soil with vapor barrier. 711 t 2. Existi Foundation, footin and slab if noted on the r ,;, ^• Floor Plan have been evaluated 4 found acceptable �„ x for this application. J. Reference Standards: ASTM E 115... ASTM E 1300... ASCE 1-10... AAMA/NPEA 2100-02 3.0: Use and occupancy category 2 4.0: All fenestration products comply 5.0: All wall and roof panels and assemblies comply 6.0: Does not apply to category 2 - -I,o: All appncaoue provisions comply K. Florida Product Approvals (provided by contractor): "SEE PRODUCT APPROVAL AFFIDAVIT" All listed product approvals have been reviewed and accepted by the engineer of record. L. DESIGN LOADS: This structure has been designed in accordance with, 4 metsts the requirements of the Florida Building Code, Residential 2014 5th Edition 4 Amendments 4 ASCE 1-10 per Section R301,2,1A 4 all applicable sections of R301 design criteria, Deetgn Criteria: Design Roof Load: Dead Load (Addition): 10 PSF Live Load (Roof): 20 PSF Wind Velocity (ULT): 165MPH (3 sec gust) Exposure: B Risk Category: II Building Height: < 30' Mean Roof Height: <I5' Enclosure Type: Sunrooms - Enclosed Max Components and Cladding Pressures: Roof Zone 1: +22.4/-40.1 pef Roof Zone 2: +22.4/-51.3 pef Roof Zone 3: +22.4/-51.3 pef Wall Zone 4. +31.6/-34.1 pef Wall Zone 5-- +31AW-38.5 pef M. Abbreviations The following list of abbreviations is not intended to represent all those used on these drawings, but to supplement the more common abbreviations used: TYP. - Typical SIM. - Similar UNO. - Unless Noted Otherwise CONT. - Continuous V.I.F - Verify In Field N. Responsibility 1, All site work shall be performed by a licensed contractor in accordance with applicable building codes, local ordinances, etc. 2. Contractor shall verify all dimensions and details, notifytng engineer of any discrepancies between drawings, fabricated items, or actual field conditions 3. These drawings represent the acceptability of the "Sunroom" room addition elements as provided by the contractor 4. All details on these drawings are engineered based on information provided by the contractor 5. Refer to the manufacturers shop drawing for further details 6. Any details not shown are to be engineered in accordance with standard engineering Practices. O. Miscellaneous i. This Structure conforms with Catagory II Sunroom requirements. 2: Catagory II Sunroome per AAMA/NPEA/NSA 2100-02 I l:¢Jidiy.',E.tw Hl i'l�lyy:�''pp4Jk''cU'4 3rI. W�L F44s' 1+iuk14i g:o - FRONT ELEVATION SCALE: 1/4" = I'-O" Section 1.0 General Requirements for Sunrooms a I II p +� Subnote 1.1 Electrical Requirements U Ill Subnote 1.11 : (Egress, Lighting required only) Subnote 1.1.2 : Exceptions: Catagory II Sunrooms are exempt from requirements for receptacle outlets. EXISTING 2 STORY - ESOLD SIDENCE PANEL". oas , WALL" LET ELEVATION SCALE: 1/4" " 1'-0" I M n- : W/ TRANS SOLID PANEL ASV. WALL W/ U TRANS co CO ABV. O O -m W/ SOLID TRANS PANEL ABV. WALL A ELECTRICAL SYMBOL OUTLET LIGHT SWITCH ji 2' FG W/ TRANS ABV, 014A S.M.S. SCREW`ui / 1 1/2" S.S. NEOPRENE GASKET WASHER (1) SCREW 0 MAX 3" FROM EA SIDE 4 0 MAX 1" O.G. - TTL OF (1) PER POLY -PANEL 0 FRONT EDGE w/ MIN. I" EMBED INTO BEAM 0 GABLE END SIDES 0 MAX 12" O.G. y HX167ING PANEL ROOF 9 SEE WALL SECT/ON 501 FOR ADDITIONAL DETAILS SEALANT EXTR'D ALUMINUM 3" x 3" x 0.125" BEAM EXTR'D ALUMINUM 014 x I" TEK SCREW 1.45" x 2.10" x 4" x .25" (3) PER L- SHAPED CLIP' L - SHAPED CLIPS TO BEAM TTL OF Cro) EXTR'D ALUMINUM 113) INTO COL. (4) EA 3" x 3" x 0.125" COL. SIDE - 2 ROWS OF 2 EAVE / BEAM / COL. / CONNECTION SECTION NOT TO SCALE 141, (2) ANCHOR CLUSTER - MAX 4" SPACING 0 MEETING RAIL FOR NON -IMPACT MAX O.G. 4 (4) ANCHOR CLUSTER FOR IMPACT 5" MAX 1 1 # r 5" MAX mil• 131/4" MAX 5" MAX ANCHORS SAME AS HEAD REQUIRED 0 SILL ANCHORS = 012 SMS OR EQUAL INTO 1/8 6063-T5 ALUM PROVIDE 5 PITCHES MIN. PAST THREAD PLANE TYP. HRZ. WINDOW ANCHOR DETAi NT TYP. ANCHOR INFO FOR FIXED GLASS 012 SMS OR EQUAL INTO 1/8" 6O63-T5 ALUM MIN. PROVIDE 5 PITCHES MIN, PAST THREAD PLANE 1/4" TAPCONS INTO CONCRETE MIN. 1 1/4" EMBED ro" MAX FROM CORNERS 4 12" MAX O.C. FRAME HEAD / SILL / JAMBS TYP. ANCHOR INFO FOR SWING DOOR 014 SMS OR EQUAL INTO 1/8" 6063-T5 ALUM MIN. PROVIDE 5 PITCHES MIN. PAST THREAD PLANE 5/16" TAPCONS INTO CONCRETE MIN. 1 1/2" EMBED (1) 5 3/4" 4 II 3/4" MAX FROM CORNERS 4 12 3/4" MAX O.C. 0 FRAME HEAD / SILL 5 MAX FROM CORNERS 4 11 1/4 MAX O.G. 0 JAMBS RIGHT ELEVATION SCALE: 1/4" = 1'-0" EXISTING 2 STORY 7.Z/ RESIDENCE OPENINGS TO REMAIN 6'SLW W/ TRANS ABV, EXISTING CONCRETE SLAB a FTG. TO REMAIN NON -HABITABLE UN-AIRCONDITIONED CONTRACTOR TO VERIFY EXACT WIN00W SIZES TYPICAL ALUMINUM COL. SYMBOL KEY ® 3 x 3 x .125 HOLLOW ALUMINUM ❑q A❑ 6'SLW 6'SLW W/ W/ TRANS TRANS ABV. ABV. +/- 30'-011 FLOOR PLAN SCA, 1/4" = 1'-0" SEE PRODUCT APPROVAL / NOA FOR TYP. CONNECTIONS FOR OPENINGS APPLY STRUCTURAL SEALANT AS NEEDED FOR WATERPROOFING GABLE -END WALLS CONNECT SILL DIRECTLY TO ROOF PANEL U.N.O. FRONT WALL SECTIONS SEE EAVE DETAIL FOR ROOF CONNECTION _ _ - - - - 014 x 3/4" ITEK SCREW BEAM 0 16" O.C. OR - _ = STAGGERED MULLION (TYP,) i SOLID PAN ELL III l --� ---1L "- L SILL 71 \ " - - FILLER AS NEEDED TI (4) 014 x 3/4" APPLY BEAD TEK SCREWS STRUCTURAL (2) EA SIDE 0 SEALANT TYPE BTM OF PANEL ---_----__ (TYP.) MULLION 014 x MULLION tEK SCREW 0 16" O.C. STAGGERED I+ _ (TYP ) (TYP.) L� 012 S.T.S. FIXED PER N.O.A. �� GLASS i MULLION " 4 CLIP I I I 014 x 3/4" TEK SCREW rL II 0 I6" O.C. STAGGERED (TYP.) �� II (TYP.) 012 S.TS, PER N.O.A. A SLIDER I I ", I I OR WINDOW II T -0 „ n p SEE LIC I I FLOOR PLAN 7-7, !" (TYP.) LLI___ 012 S.T,8. PER N.O,A, I 014 x 3/4" MULLION TEK SCREW 0 Ira" O.G. STAGGERED (TYP.) SILL/ SOLID II PANEL KICK APPLY BEAD STRUCTURAL SEALANT TYP.Ir 11 (4) 014 x 3/4" TEK SCREWS SILL (2) EA SIDE 0 \ BTM OF PANEL (TYP.) -ram-- - OUTSIDE -� EDGE ----_-_-- 6'SLW W/ TRANS ABV, SEE SILL CONNECTION DETAIL WALL SECTION NOT TO SCALE SOLID W/ PANEL TRANS 0 WALL ASV. SOLID W/ PANEL TRANS WALL ABV. O a❑ W/ + SOLID TRANS PANEL ABV. WALL 2' FG W/ BRAN: ABV, 1/4" x 2 1/2" FASTENERS OUTSIDE FACE OF INTO EXISTING STRUCTURE EXISTING STRUCTURE / COLS. tr 0 16" O.C. MAX. VERTICALLY APPLY CAULKING BETWEEN SILL 4 WALL "' "•"'" """' ^ ' TAPCONS FOR CONIC. / 012 °- ' -' s w, PANELr%s?) fl� LAG -BOLTS w/ WASHER x 3/4" TEK SCREWS:IIALL FOR WOOD FRAME 0 RECEIVER CHANNEL t0 WALL PANEL ✓erir�ta 0 MAX 12" O.G. VERT. PLAN VIEW OSO" RECEIVER CHANN ATTACHMENT TO EXISTING STRUCTURE FOR SOLID PANEL NOT TO SCALE INSIDE ROOM (3) 014 x 3/4" TEK SCREWS WALL EACH SIDE OF COLUMN PANEL Q_- (- --- SEE SILL U 3" x 3" x 0.125" U , CONNECTION FOR DETAIL ALUMINUM Oz - COL. I 714 I PLAN VIEW (3) 014 x 3/4" TEK SCREWS CONT. L5" x 3" x .OSO" CLIP TO COLUMN EXTR'D ALUMINUM SILL TYP 3" ALUM. COL. CONNECTIONS NOT TO SCALE PLAN VIEW TYP (3) 014 x 3/4" TEK SCREWS CLIP TO COLUMN WIN. INSIDE ROOM 1.5" x 3" x .090" EXTR'D ALUMINUM SILL BELOW ,,MULLION CLIP TYP (3) 014 x 3/4" TEK 3 x 3 x 0.125 SCREWS SILL TO ALUMINUM OUT SIDE CORNER COL, ❑ WALL OF COLUMN A PANEL TYP. V ALUM. CORNER COL. CONNECTION AT SILL NOT TO tDCALE NSIDE LU •• TAPGON SCREWS 0 2" MIN OF = 4 ANCHOR BOLTS 0 3" MIN ROOM z FROM CONCRETE EDGE I 2" - 3" SILL CONNECTION TO CONCRETE - MIN. (U 3/8" x 2 1/2" TAPCON SCREWS MIN, ON EA SIDE OF UPRIGHT 0 2" MAX 4 MAX 12" O.G. BETWEEN - OR - (I) 3/8" x 3 3/4" ANCHOR BOLT i ON EA SIDE OF UPRIGHT 0 2" MAX UNIT WIDTH / LENGTH 4 MAX 16" O.G. BETWEEN SILL TO CONCRETE SLAB CONNECTION DETAILI NOT TO SCALE WALLS UNDER SUNROOM SYSTEM PORCH ENCLOSURE SOLARIUM PER AAMA/NPEA/NSA 2100-02 THIS STRUCTURE MEETS SUNROOM CATEGORY "II" REQUIREMENTS PRODUCT APPROVAL SUBMITTAL AFFIDAVIT T FOLLOWING PRODUCTS WILL BE THE DAWSON RESIDENCE 132 lE IIISTALLED IN THE STRUCTURE LOCATED AT: PEPPER LANE, JENSEN BEACH, FL 34951 PROD. DESIGN PRODUCT PRODUCT PRESSURES MANUF, MODEL • APPROVAL FRENCH +/- 86 PSF LAWSON 2200 LaPORTE IMPACT FL 15443.2 DOOR HRZ. WINDOW */- 80 PSF LAWSON HS 8100 IMPACT FL 15428.3 FIXED WINDOW +/- 18.0 PSF LAWSON 4200/6200 IMPACT FL 1542S.2 MULLIONS */- 54 PSF LAWSON I x 3 IMPACT Alum, FL 15532.1 STRUCTURAL 3" x 0.032"x 20 EPS IMPACT WALL / KICKS * 43 -10 PSF ELITE Aluminum composite Panel FL 12225,1 1 HAVE REVIEWED THE ABOVE COMPONENTS AND CLADDING, RE ICI E AND HAVE APPROVED THEIR JUL. 18207 USE IN THE STRUCTURE TO PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY THE CLIRRENT CODE PROVISIONS. AS SIGNED, SEALED A DATED HERE... Q� O wM O � zaAw� rho V Y Z U u0 z zO��R w 0.4 WDor�nx 1> O U 4.4J LU Cal Q LU LU OL ® IJ-t ) U- L LU Qi (+1 L 0.1 710 0) �- ° �U_u,r� Qj ^� tIl � N UQ)cc O ` � (L LL W_ 0 4 1L a Copyright 2011 All rights reserved, REVISION DATE JOB 0 1752 DATE : 61211E SHEET 1 of 1