Loading...
HomeMy WebLinkAboutKSM SOIL COMPACTION REPORT 2-14-22Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #:2202069-1d/AH/dc NUC #240Nuc Model:MC-1 Elite Nuc Serial #:31240 6110 Bamboo DriveFort Pierce, Florida Backfill for the 1st and 2nd Lifts DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1 N.W.0" - 12"50 D 109.5 111.5 98.2% 2 N.E."50 D 110.2 "98.8% 3 Center "50 D 108.6 "97.4% 4 S.E."50 D 109.4 "98.1% 5 S.W."50 D 109.9 "98.6% Proctor Optimum Moisture: Proctor Max. Dry Density: P.C.F. @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets 2/25/2022 Brown Sand With Some Clay Proudly Serving Florida since 1990 Certified Women Owned Business - WBE Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test.KSM is not responsible if the tested area has been altered from the approved inspected condition. Julie E. Keller, P.E. President PE # 68366 Email to: reloaderserviceinc@gmail.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting 111.5 Minimum Requirement For an Unstaked Foundation Respectfully Submitted: In Place Moisture: 8.1 % 10 % TEST LOCATION OF SAMPLE Soil Description: PERMIT #:21080262 CONTRACTOR:R & E Loader Service, Inc SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 DATE TESTED:February 24, 2022 ITEM TESTED: JOB LOCATION: 108.0 109.0 110.0 111.0 112.0 113.0 5 6 7 8 9 10 11 12 13 W E I G H T P C F D R Y Moisture -% of Dry Weight