Loading...
HomeMy WebLinkAboutIn Place Density Test Report- S Side WallUES Project No: Workorder No: Report Date: 3310.2100259.0000 261952-1 02/23/2022 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:Panelli Fort Pierce, LLC UES Technician:Juan Hernandez 16460 SW 137th Avenue Miami, FL 33177 Date Tested:02/23/2022 Project: Wolflube Warehouse-Manufacturing Bldg Phase I 4774 South Jenkins Road, Fort Pierce, St. Lucie County, FL 34981 Type of Test: Area Tested:South Side Footing on Site Wall Field:ASTM D-6938 Nuclear Gauge Method Material:Native Laboratory:AASHTO T180 Modified Proctor Reference Datum:0 = Bottom of Footing The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 South east corner 0-1 ft 105.2 11.5 104.3 11.2 99 Pass 2 South west corner 0-1 ft 105.2 11.5 104.6 11.0 99 Pass Remarks:Permit: 2112-0081 Reviewed By GFA International, Inc FBPE Registry No.4930 Alex Albandoz, P.E. STATE OF FLORIDA Professional Engineer No. 92555 This item has been digitally signed and sealed by Alex Albandoz, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1