HomeMy WebLinkAboutREVISED C18RECONSTRUCTED HOUSE FOR
FREDERICK & MARY DONGHIA
509 N. 43 ST.
FT. PIERCE, FL. 34947 511 SW PORT SAINT LUCIE BLVD.
PORT ST. LUCIE, FL 34953P1 08/24/20P2 09/29/20P3 10/21/20FRONT (WEST) ELEVATIONSCALE:14'' = 1'-0''TOP OF WINDOWS TO FASCIA=11-3/16'' +/- W/2x4 END RAILCOMPOSITE LAMINATEASPHALT SHINGLEROOFINGSTUCCOFINISHTYP. O.H.24" OVERHANGOVER DOORSALUM DRIPTYP. ALL SIDESALUM. FASCIA& PERFORATEDSOFFITTYP. ALL SIDESFinish GradeFinish Floor8'-1"' Truss BearingCONCRETELANDING & WALK150 ADISCONNECTFIELD LOCATECONDUIT TO EXISTON SITE METER ANDSERVICE POINTNON-IMPACTS.C. DOORSNON-IMPACT RATEDPVC SINGLE HUNGWINDOWS+ 39.2- 42.6+ 38.5- 41.9+ 38.5- 41.9ROOF PLANSCALE:18" = 1'-0''22"x30"ATTICACCESSHIP RIDGERIDGE ROOF SHEATHING58" (1932") APA RATED 40/20CDX EXTERIOR PLYWOOD SHEATHINGSECURED TO TRUSSES USING FASTENERS AND SPACINGPER ROOF SHEATHING ATTACHMENT DETAIL ON SHT. 5ROOF FINISHESLAMINATE COMPOSITE ASPHALT SHINGLESSECURED USING FASTENERS AND SPACING PER MFR'SSPECIFICATIONS OVER 30" FELT TIN TAGGED TOSHEATHINGFLASHING : GALV MTL.DRIP EDGE: 26 Ga. ALUM.HIP RIDGEHIP RIDGEHIP RIDGE1'-0"1'-0"
2'-6"17'-8"1'-0"1'-0"1'-0"1'-0"1'-0"ST LUCIE COUNTY BUILDING & CODE REGULATION DIVISION PRODUCT APPROVAL SUBMITTAL AFFIDAVITBUILDING PERMITOWNERS NAMECONTRACTOR - GROZA BUILDERS CONTRACTOR'S ADDRESS 511 SW PORT ST LUCIE BLVD PORT ST LUCIE FL 34953OPENING PROTECTIVES (WINDOWS, DOORS, AND SKYLIGHTS), COMPONENTS AND CLADDINGPRODUCTNOTE:ALL MANUFACTURED HOLES FOR ANCHORING MUST BE FILLED WITH APPROPRIATE FASTENERSI HAVE REVIEWED THE ABOVE COMPONENTS AND CLADDING AND HAVE APPROVED THEIRUSE IN THIS STRUCTURE TO PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS ANDFORCES SPECIFIED BY CURRENT CODE PROVISIONS.NAMESIGNATUREDESIGN FIRMCERT. NOMANUFACTURERMODEL / TYPEGLAZING DESCRIPTIONF.P.A.OR NOA (MIAMI DADE)BUILDING DESIGNPRESSURESMETHOD OF ATTACHMENTPRODUCT DESIGNPRESSURESDATEHURRICANE PANELSLESS THAN 6' SPANFPA:FL 11968.3 R5APPR. DATE: 12-15-20+70.0 / -80.0EASTERN METAL SUPPLYFREDERICK & MARY DONGHIAENTRY DOOR - OUT SWINGNON IMPACT RATEDSEE COVER SHEET14" TAPCONS @ 14" O.C. w/ 114" EMBEDAND 6" OFF CORNERSPLASTPRO INC.FIBERGLASS FRAME, OPAQUESINGLE LEAFFPA: FL 17184.13 R8 NON IMPACTAPP. DATE: 10-13-20SECONDARY DOOR - OSNON IMPACT RATED+/-50 PSFSEE COVER SHEET14" TAPCONS @ 14" O.C. w/ 114" EMBEDAND 6" OFF CORNERSPLASTPRO INC.FIBERGLASS FRAME, OPAQUESINGLE LEAFFPA: FL 17184.13 R8 NON IMPACTAPP. DATE: 10-13-20+/-50 PSFSEE ELEVATION SHEETSee FPA installation details sheets providedWINDOWS - SINGLE HUNGNON-IMPACT RATEDCWS WINDOWS.LOW-E 366 INSULATEDFPA: FL 17234.1 NON IMPACTSH610 PVC SINGLE HUNG+70.0 /- 84.4 PSFSH 25+70.0 /- 71.6 PSFSH 35ROOF FINISHSOFFITKAYCAN LTD2x4 BRACE AT CENTER OF PANEL+23.6 / -28.8+66.7 / -66.7ROOF VENTSApply roofing cement to the underside, back, and sideflanges of roof vent. Cement should be 14" min. thickand extend 2" beyond and onto roofing underlaymentsFPA:FL 16503.1REV. DATE: 02-13-18TRIPLE 4 FULL-O-VENT ECOVINYL SOFFIT PANELSFLORIDA METAL PRODUCTS,INC.FLAMCOLOW PROFILE OFF RIDGE VENTSFPA: FL 21580.1APPR DATE: 12-12-17+/-46 PSFUnderlayments must be ASTM D226 Type II,ASTM D4869 Type IV, & D6757Complying w/FBC-R 2020, 7th Ed. R905.1.1.1VARIOUS SUPPLIERSPer FBC-R R905.1.1.1 : (2) layers min overlapped 19"secured w/ 1" dia. mtl. taps and 0.083 dia. shank nails34" min into shthg. @ 12" o.c. in field, 6" o.c. along edgesUNDERLAYMENTSPEEL & STICKUNDERLAYMENTSNAILABLEVARIOUS SUPPLIERSUnderlayments and joint coveringsmust be ASTM 1970Complying w/FBC-R 2020, 7th Ed. R905.1.1.1Per FBC-R R905.1.1.1 :installed per both underlayment manufacturer's androof covering manufacturer's installation instructions6 ROOFING NAILS PER TAB, CLASS F OR HIKO iNDUSTRIESLAMINATE ASPHALTSHINGLESNOA:16-0329.13EXP. DATE: 05-05-2124 Ga. 'BERTHA' 2" DEEPGALV. STL. STORM PANELSDIRECT MOUNT:14" d. - 20 x 112" long, sidewalk boltsw/ 212" edge distance @ 12" o.c. max., top and bott.1############DONGHIA (2021-02-25) Permitset.dwg2/24/22C1COVER1SHEETDESCRIPTIONDATEREVBuilder:Project:SCALE:OFMODELOWNERDESIGN BYCHECKED BY12345678DRAWING INDEXC1COVER PAGEA1FOUNDATION PAGEA2FLOOR PLANA3ELECTRICAL PLANA4EXTERIOR ELEVATIONSA5ROOF PLANA6HVAC PLANS1ENGINEER DETAIL PAGES2ENGINEER DETAIL PAGEA CUSTOM HOME FOR:GROZA BUILDERS, INC.DONGHIA FMDFREDERICK & MARY DONGHIA509 N. 43rd ST.FT. PIERCE, FL 34947CHRISTOPHER D. BEERS, P.E.FLORIDA LICENSE NO. 64594W A T E R - A I R - L A N D5109 Grand Palmetto WayNorth Port, Florida 34291-8049941-628-0635fax 413-687-9013chrisbeers@byu.net