Loading...
HomeMy WebLinkAboutPool Construction PlanPUMP WITH HAIR AND LINT STRAINER (SEE ATTACHED CALCULATIONS) WASTE (RETAIN ON SITE) ERE SYSTEM ESSURE AND AIR SE VALVE LEGEND 2.5"0 SCH. 40 PVC MAIN RETURN LINE M CHECKVALVE POOL N 2-WAY VALVE FLOW DIRECTION o: i z w a Y oa �Z N 00 N N ax U is w cv N NOTE: PIPE SIZING TO BE DETERMINED BY HYDRAULIC CALCULATIONS PLUMBING DIAGRAM 11110 100 1,� e f e( I } 1 k E E E , ) ` LL 10 E 44 a f t AR ^ q a E I �ry��p a { I i TO ELEC. SERVICE VIA WATER PROOF G.F.I. NO MORE THAN 20' FROM POOL EDGE AND NOT WITHIN 10' OF POOL EDGE 3 JUNCTION BOX 48" MIN. WATER LINE -� 18" MIN. 12V LIGHT W/ - LOW WATER CUTOFF DEVICE Determine Minimum System Flow Rate: (35 gpm per Skimmer) 1. Pool Volume Calculation: 293 flf (Surf Area) x 4.25 fit (Avg. Depth) x 7.48 gaVR3= 9,314 gal 2. Determine Flow Rate: 9,314 gal / 360 min = 25.87 gpm + 0 gpm = 25.87 gpm (Volume) (Turnover Time) (Pool Flow) (Feature Flow) (System Flow) 3. Determine Pipe Sizes: Trunk Piping to be 2.5" to keep velocity at 811ps max. at 117 gpm Maximum System Flow Rate Return Piping to be 2.5" to keep velocity at 811ps max. at 117 gpm Maximum System Flow Rate System Flow Rate Must Not Exceed Flow Rate for Main Drain Cover (See Detail at Right) Pump Model: VSFHP165AUT H.P.: 1.OHP Total H.P. = H.P. x service factor. 1 H.P. or more must be.2 speed or variable speed. Filter Make: CS 150 Size: 150 Filter min. area based on 6 hr turnover Flow rate (pool flow rate calculated above) Divide gpm by the following factors: Cartridge - 0.375, Sand -15 or D.E. - 2 Time Controller Make: Intennatic Model: PE 36300 RETURN PIPING ftowGpm OTE: SEE ATTACHED HYDRAULIC CALCULATIONS FOR ADDITIONAL DETAILS TRUNK PIPING REGARDING PUMP FLOW RATES AND TOTAL DYNAMIC HEAD CALCULATIONS. SELECTED EQUIPMENT CALCULATIONS PROPERTY LINE v (� W. X- } fi- 4 /It$I Siril t.! Q + ulhm F'ilil(} i �K�)I,I�i "�.�i���i i/if h1.+aY6 �I't, S3A�fYl/!u(1)15R id ,_� CUG9PLy WIT)I /aLl, ftFhIIQA�L� C0�7F�, �� EXISTING CARPORT NJ S Pipe Size 6 fps 8 fps (in.) GPM Loss (fVft) GPM Loss (ft/ft) 1.0 16 0.14 21 0.23 1.5 37 0.08 50 0.14 2.0 62 0.06 82 0.10 2.5 88 0.05 117 0.09 3.0 136 0.04 181 _ 0.0_ 7 4.0 234 0.03 313 0.05 6.0 534 0.02 _ 712 0.03 8" MIN, WP MANUAL STARTER SWITCH (TYP.) 3-#12 WIRES IN 3/4" CONDUIT A L^�► TO PUMP -+s TO PUMP 2 (IF APPLICABLE) PANEL TO BLOWER (IF APPLICABLE) 44 TO HEATER (IF APPLICABLE) 3#8 WIRES IN 1" CONDUIT - 3 - #12 WIRES IN 3/4" CONDUIT SPST TOGGLE SWITCH 12V TRANS. - 1" NON -CORROSIVE CONDUIT POOL WALL AND DECK (SEE TYPICAL SECTION) ELECTRICAL DIAGRAM N.T.S. STAINLESS STEEL HANDRAIL (SAME BONDING FOR LADDER) POOL DECK 6" MAX. MIN. #8 BARE AWG COPPER AROUND PERIMETER OF POOL 18"-24" CONNECT PERIMETER -� GROUND WIRE TO _ GROUND SYSTEM CONNECT #8 BARE AWG COPPER WITH APPROVED BOND CLAMP LIGHT NICHE NOTE: BONDING PER FLORIDA BUIDING CODE ADAPTATION OF N.E.C. 2011 SECTION 680.26 2' FLAT PAVER DECK WIDTH VARIES 2-3/8" CONCRETE PAVER TO BE SANQ SET WITH A 6"X9" CONCRETE SET COPING SURROUNDING THE POOL. SUB -SOILS TO BE COMPACTED TO 95% MAX. DENSITY - 6" WATERLINE TILE 2- #3 BARS AT TOP W/ 3" 1:3 MAX. SLOPE HOOK ON VERT. STEEL " z w WIDTH VARIES FROM 4' - 6" cQi 0 w CL of LU J Jul Q > M Q e Z (D 50 M - N NOTES: 1.) PAVERS MAY BE SUBSTITUTED FOR CONCRETE DECK. 2.) WALLS OVER 6' IN HEIGHT SHALL BE REINFORCED PER WALL OPTIONS TABLE BELOW CONNECT #8 BARE AWG COPPER WITH APPROVED • BOND CLAMP MIN. FOUR (4) CONNECTIONS (ONE c - EACH SIDE) W/ #8 BARE a� AWG COPPER W/ APPROVED CLAMPS 5' 4'-11" EQUIPOTENTIAL BONDING GRID DETAIL ST, LUCIE COUNTY IIUI' DING DIV(StON EXISTING f"1- `tE.1' EJ RESIDENCE r,SVIEL%'Ei ElyCCd,1 CE (( fj 8' DATE PEr^ ' Pit 16 KEPT OA' J08 OR Nam, CDrON Wit, CQ A4A 3 -{ 4' NOTE: LAYOUT PROVIDED BY CONTRACTOR POOL LAYOUT/ LONGITUDINAL POOL SECTION SCALE: 1/4" = 1' 2,4„ 2'4" PROPERTY LINE N.T.S. SWIMOUT DEPTH DETAIL N.T.S. s R 4 STEEL A EQUIVALENT #3 BARS @ 12" O.C. E.W. CENTERED IN CONCRETE TYPICAL WALL AND DECK SECTION (MAX 6' HEIGHT) 11° SLOPE MAX. (TYP.) N.T.S. LOCATION LONGITUDINAL POOL SECTION N.T.S. HYDROSTATIC VALVE (1-1/2") e GRATE TO BE ATTACHED WITH SCREW e 6" PLASTER FINISH, GEM COAT OR EQUIVALENT 11° SLOPE MAX. (TYR) TREMOVE 3'4" ROCK BED (MIN 3YDS. ROCK TO STABILIZE SOIL) WELL POINT THREADED GRAT= AND WELL POINT VALVE PVC PIPE FROM MAIN DR41N, AND ATTACH AUX. PUMP LINE WHEN EM)TYING WELLPOINT N.T.S. 10 1/2„ 1' -<10-1/2" #3 BARS @ 8" O.C. x' (TYP. TOP OF STAIR) -r 10-1/2" #3 BARS HOOKED INTO WALL REINFORCEMENT 6 PER WALL DETAIL -, ". 0-1/2" VERTICAL REINFORCEMENT- #3 BARS @ 12" O.C. STAIRS DETAIL EQUIPMENT-.,e...... - o ... e ) TYPE DESCRIPTION PART NUMBER QN- Circulation Pump Zodiac/Jandy Variable Speed w/ IQ Pump Ctrls. VSFHP165AUT 1 Circulation Filter Zodiac CS 150 Cartridge Filter 1 Salt/Chlorine Generator Zodiac/Jandy True Clear Salt System Truclearl 1 K 1 LED Lights Jandy Pro Series LED Color 20 Watt 1 Light Transformer Intermatic Stainless Steel 100W Trans. T104P3 1 Valves Jandy 3-Port Never Lube 2717 2 N.T.S. SAFETY NOTES 1. NO DIVING BOARD OR DIVING IS ALLOWED IN ANY POOL WITH A DEPTH LESS THAN 8'-8" AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL DOES NOT CONFORM TO THESE REQUIREMENTS AND NO DIVING SHALL BE PERMITTED 2. THIS POOL TO BE EQUIPPED WITH CHILD SAFETY FENCE AROUND THE PERIMETER OF THE POOL OR ALARMS AT THE ENTRANCES TO THE POOL (ONE TO BE CHECKED). GENERAL NOTES 1. ALL FLOORS AND WALLS OF POOL TO BE CONSTRUCTED USING PNEUMATICALLY APPLIED CONCRETE WITH 28 DAY STRENGTH OF 2500 PSI. 2. REINFORCING STEEL SHALL CONFORM TO A.S.T.M. 615 GRADE 60 3. PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL. 4. POOLS TO BE CONSTRUCTED ONLY ON CLEAN SAND OR ROCK. SOILS IN FINAL BACKFILL SHALL BE COMPACTED TO PROVIDE A MINIMUM BEARING CAPACITY OF 1000 ESE. ALL UNSUITABLE MATERIALS SHALL BE REMOVED AND REPLACED WITH CLEAN SAND PLACED AND COMPACTED IN 12" LIFTS. 5. ALL BACKFILL SHALL BE PLACED WITH CARE IN ORDER TO ENSURE THAT PLUMBING IS NOT DISTURBED. ALL FILL SHALL BE CLEAN SAND PLACED IN 12" LIFTS AND COMPACTED TO 98% OF MAXIMUM DENSITY, 6. THE CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS IN ORDER TO PROTECT EXISTING STRUCTURES AFFECTED BY THE CONSTRUCTION. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. T ENGINEERING PLOT PLANS WERE NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES WHEN NECESSARY. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. AS SUCH, THE ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACKS. 8. CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES ON SITE AND SHALL MAINTAIN MINIMUM SEPARATIONS AS REQUIRED BY LOCAL REGULATIONS. GENERALLY, ELECTRICAL LINES SHALL BE A MINIMUM OF 10 FEET FROM OPEN WATER. 9. ALL UNSCREENED POOLS SHALL HAVE A FENCE A MINIMUM OF 4 FEET IN HEIGHT WITH SELF-LOCKING GATES, 10. WHERE POOLS ABUT OR ARE PLACED NEAR SEAWALLS OR BULKHEADS SPECIAL CARE SHOULD BE TAKEN, NOTIFY ENGINEER OF THIS CONDITION FOR ANALYSIS AND RE -DESIGN IF NECESSARY. 1 t. PATIO DESIGN MAY BE NOTED TO BE COMPLETED BY OTHERS. WHEN NOTED, ANY DETAILS REFERRING TO PATIO DESIGN ARE NOT APPLICABLE. THE TYPICAL WALL SECTIONS OF POOL ARE NOT APPLICABLE TO PAVEMENT DESIGN. 12. VACUUM LINE SHALL INCLUDE A SPRING LOADED SELF CLOSING COVER. 13. THE SWIMMING POOL MUST BE BUILT TO MEET 2014 FLORIDA BUILDING CODE, AS WELL AS ANSI 7, AND SHALL BE ANSI 15 COMPLIANT. 14. BASE MATERIAL THICKNESS MUST BE 125% OF CONCRETE FASTENER EMBEDMENT, 15. HOMEOWNER MUST BE AWARE OF THE POSSIBILITY OF EROSION AND SHALL BE RESPONSIBLE FOR MAINTENANCE IN ORDER TO PREVENT FAILURE. 16. WATER VELOCITY MAXIMUM 8 FT/SEC AS PER FBC 2014-R4501.6.3 17. POOL BARRIER TO COMPLY WITH FBC 2014-R4501 18. SKIMMERS TO COMPLY WITH FBC 2014-4501.21.2 19. EQUIPMENT FOUNDATION CONCRETE SLAB, MIN. 3.5" THICK, POUR IN PLACE. 20. WATER HEATING EQUIPMENT TO COMPLY WITH FBC 2014-R4501 21. ALL DECK AND SLAB CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 P.S.I. IN 28 DAYS UNLESS OTHERWISE NOTED. 2011 POOL PUMP ENERGY EFFICIENCY REQUIREMENTS REQUIREMENTS APPLY TO EXISTING POOL DOESN'T APPLY TO REP_LAC MENTS/ADDITIONS AND NEW COMMERCIAL POOLS CONSTRUCTION IS THE PUMP MOTOR US N.T.S. SAFETY NOTES 1. NO DIVING BOARD OR DIVING IS ALLOWED IN ANY POOL WITH A DEPTH LESS THAN 8'-8" AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL DOES NOT CONFORM TO THESE REQUIREMENTS AND NO DIVING SHALL BE PERMITTED 2. THIS POOL TO BE EQUIPPED WITH CHILD SAFETY FENCE AROUND THE PERIMETER OF THE POOL OR ALARMS AT THE ENTRANCES TO THE POOL (ONE TO BE CHECKED). GENERAL NOTES 1. ALL FLOORS AND WALLS OF POOL TO BE CONSTRUCTED USING PNEUMATICALLY APPLIED CONCRETE WITH 28 DAY STRENGTH OF 2500 PSI. 2. REINFORCING STEEL SHALL CONFORM TO A.S.T.M. 615 GRADE 60 3. PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL. 4. POOLS TO BE CONSTRUCTED ONLY ON CLEAN SAND OR ROCK. SOILS IN FINAL BACKFILL SHALL BE COMPACTED TO PROVIDE A MINIMUM BEARING CAPACITY OF 1000 ESE. ALL UNSUITABLE MATERIALS SHALL BE REMOVED AND REPLACED WITH CLEAN SAND PLACED AND COMPACTED IN 12" LIFTS. 5. ALL BACKFILL SHALL BE PLACED WITH CARE IN ORDER TO ENSURE THAT PLUMBING IS NOT DISTURBED. ALL FILL SHALL BE CLEAN SAND PLACED IN 12" LIFTS AND COMPACTED TO 98% OF MAXIMUM DENSITY, 6. THE CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS IN ORDER TO PROTECT EXISTING STRUCTURES AFFECTED BY THE CONSTRUCTION. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. T ENGINEERING PLOT PLANS WERE NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES WHEN NECESSARY. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. AS SUCH, THE ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACKS. 8. CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES ON SITE AND SHALL MAINTAIN MINIMUM SEPARATIONS AS REQUIRED BY LOCAL REGULATIONS. GENERALLY, ELECTRICAL LINES SHALL BE A MINIMUM OF 10 FEET FROM OPEN WATER. 9. ALL UNSCREENED POOLS SHALL HAVE A FENCE A MINIMUM OF 4 FEET IN HEIGHT WITH SELF-LOCKING GATES, 10. WHERE POOLS ABUT OR ARE PLACED NEAR SEAWALLS OR BULKHEADS SPECIAL CARE SHOULD BE TAKEN, NOTIFY ENGINEER OF THIS CONDITION FOR ANALYSIS AND RE -DESIGN IF NECESSARY. 1 t. PATIO DESIGN MAY BE NOTED TO BE COMPLETED BY OTHERS. WHEN NOTED, ANY DETAILS REFERRING TO PATIO DESIGN ARE NOT APPLICABLE. THE TYPICAL WALL SECTIONS OF POOL ARE NOT APPLICABLE TO PAVEMENT DESIGN. 12. VACUUM LINE SHALL INCLUDE A SPRING LOADED SELF CLOSING COVER. 13. THE SWIMMING POOL MUST BE BUILT TO MEET 2014 FLORIDA BUILDING CODE, AS WELL AS ANSI 7, AND SHALL BE ANSI 15 COMPLIANT. 14. BASE MATERIAL THICKNESS MUST BE 125% OF CONCRETE FASTENER EMBEDMENT, 15. HOMEOWNER MUST BE AWARE OF THE POSSIBILITY OF EROSION AND SHALL BE RESPONSIBLE FOR MAINTENANCE IN ORDER TO PREVENT FAILURE. 16. WATER VELOCITY MAXIMUM 8 FT/SEC AS PER FBC 2014-R4501.6.3 17. POOL BARRIER TO COMPLY WITH FBC 2014-R4501 18. SKIMMERS TO COMPLY WITH FBC 2014-4501.21.2 19. EQUIPMENT FOUNDATION CONCRETE SLAB, MIN. 3.5" THICK, POUR IN PLACE. 20. WATER HEATING EQUIPMENT TO COMPLY WITH FBC 2014-R4501 21. ALL DECK AND SLAB CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 P.S.I. IN 28 DAYS UNLESS OTHERWISE NOTED. 2011 POOL PUMP ENERGY EFFICIENCY REQUIREMENTS REQUIREMENTS APPLY TO EXISTING POOL DOESN'T APPLY TO REP_LAC MENTS/ADDITIONS AND NEW COMMERCIAL POOLS CONSTRUCTION IS THE PUMP MOTOR US 7DOESN'TAPPLYTO OR HYDROSTATx1 VALVE p p 111, 0 ° p 00000 4 qa 4• li Gp (}O °q0 O ° Ob .I).. p p _t+ ° M o G pq q a ° O pp° pp. p.pq 00 p q ♦ Q a q. o p ° .:.� Q y�}y Lt..l-1 p p °° p q q O a p p O p { y. p g�q � b ° 1 p� p0II dp°b C F ° Q pq. O p qp p b Y by � ...0 �.� iI'L[.Li:. :a ° A boa b a b u p o p o a p. p .12:L? El :1212J2: ° °b a ° IILr2J: 12Ian: 0 00 0060 00 Q 000 0 o LTTI:LL 0 000g 00 � Q) �c� 00 � � 3 6ART TCRETE r GUNf1E GRA TO PUM NOTE: 2.5" CONNECTION ON THIS CUSTOM MOLDED PRODUCTS 32" INSTALLATION CHANNEL DRAIN VGB-2009 COMPLIANT - smeuEWECONWCTIONON ANY OF RTS: PO MODEL:CMP25506-32X +-ur, 2-10- ORGREATER PIPE NOTE: THE MAXIMUM FLOW RATING FOR THIS SUCTION FITTING AS CONFIGURED WITH OUTER PORTS PLUGGED AND CENTER PORT OPEN IS 200 GPM (FLOOR) WHEN USING 2.5" PLUMBING AND 184 GPM WHEN USING 2" PLUMBING. CHANNEL DRAIN INSTALLATION DETAIL