Loading...
HomeMy WebLinkAboutDesign Pressure Calculations"Building Our Quality Reputation One Customer At A Time" Information Owner: VICTOR & NANCY DEPIETRO Address: 12 CROWN CT FORT PIERCE, FL 34949 SCC131150472 Information Wind Zone: 170 MPH. Exposure Category: C Minimum Building Dimension: 35 ft. Mean Roof Height: 20 ft. Risk Category: II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) j[:F:,1e�va7fion(ft) Max Positive Pressure (psfj Max Negative Pressure (psf} 1 2 3 Int End Int 72 72 35 80 60 37 7 7 7 36.5 37.3 40.2 -39.9 -48.0 -43.6 -- 4 End 34.._.__ 61 7 --39.2 -51.9 5 Int - 35 61 _ 7 - 39.1 -42.5 6 Int 37 80 7 38.3 -41.7 7 - -Int 37 80 7 38.3 -41.7 8 End 35 61 7 39.1 -51.7 9 End 72 61 7 37.2 -47.9 10 End 72 __w....._61 _ _ 7 37.2 -47.9 I - Int WW 37 80 7 - 39.3 -41.7 12 End 34 23 7 40.2 -53.8 13 Int 34 24 7 40.2 _ -_43.6 14 _ Int 71 79 -u- 7 36.6 -40.0 15 m- Int 72 60 7 37.3 -40.7 - 16 End 72 60 7 37.3 -48.0 17 Int 35 37 7 40.2 -43.6 18 Int 35 37 7___ 40.2 -43.6 in accordance with: ASCF, 7-16, Chapter 30. Wind Lauds - Cwnpauenu and Cladding. 7th Edition (2020) Florida Building Code, Page 1 of 1