Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4MgnthashTonyPereira-MS93764FINALDESIGNStamped (1)
PLAN KEY PV-1 COVER PAGE PV-2 SITE PLAN PV-3 PANEL SPECIFICATION PV-3.1 PANEL LOAD TESTING RESULTS PV-3.2 INVERTER SPECIFICATION PV-3.3 COMBINER BOX SPECIFICATION PV-3.4 JUNCTION BOX SPECIFICATION PV-3.5 ATTACHMENT DETAIL PV-3.6 STRUCTURAL CALCULATION PV-3.7 SEALANT SPECIFICATION PV-4 THREE LINE DIAGRAM PV-4.1 ELECTRICAL NOTES PV-4.2 EQUIPMENT LABELS PV-5 STRUCTURAL CERTIFICATION BUILDING INFORMATION/B.O.M. # STORIES 1/15 ROOF AREA 2054.43 P.V. AREA 559 ROOFING TYPE CORRUGATED METAL ROOF PITCH 18 # RAILS 15 # L-FOOT ATTACHMENTS 42 # MODULES 29 # INVERTERS 29 # SKIRTS 0 # ENPHASE COMBINER BOXES 1 EATON 60A FUSIBLE SOLAR AC DISCONNECT 1 40AFUSES 2 125A LINE TAPS 2 SYSTEAD INFORADATION MODULE HANWHA Q.PEAK DUO BLK-G10+ 360 INVERTER ENPHASE IQ7-60-2-US RACKING SUNMODO EZ GRIP & ECOFASTENCLICKFITSYSTEM 2-RAIL SYSTEM SIZE (DC) 10.44 KW LOCATION 27.3347256,-80.3328213 J HANWHA Q.PEAK DUO BLK-G10+ 360 360 WATT MODULE 67.6" X 41.1" X 1.26" (SEE DATASHEET) THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE, 7TH EDITION 2020 FLORIDA FIRE PREVENTION CODE, NEC 2017 AND ALL LOCAL CODES & ORDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF FOR SLOPED ROOF AND NO MORE THAN 10-INCHES ABOVE THE SURFACE OF THE ROOF FOR FLAT ROOF. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF CHAPTER 471 ENGINEERING AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO THE DESIGN CONSTRUCTION OR ALTERATION OF BUILDINGS AND STRUCTURES FOR HUMAN HABITATION. INVERTER PLACEMENT: SYSTEM UTILIZES "ENPHASE" MICRO -INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. STRUCTURAL STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE SECTION 1512 THROUGH 1525 AND SECTION 1616 THROUGH 1626 FOR HIGH VELOCITY HURRICANE ZONES. FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2020 011 momentum PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING A. MA • . k '. ��P ' �CENS No PE86753 0 STATE OF AIL II Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Starn shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAIOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I I INITIAL I DATE: 2/10/2022 1 DESIGNER: SN I (REV: (DATE: (DESIGNER: (REV: (DATE: (DESIGNER: COVER PAGE PV-1 LU w 0 z Q ww 0 Nw LU 0 z RAFTER SPACING 24" O.C. (TYP) SITE PLAN 44'-0Ilk 2" 4'-411 ,ice 4'-4" 44'-0211 56'-6" R1 SCALE: 1/8" = 1'-0" NOTE: 1. ROOF COVERING MATERIAL IS COMPOSED OF CORRUGATED METAL 2. EXACT ATTACHMENT LOCATION AND QUANTITY OF ATTACHMENTS ARE BASED ON EXISTING RAFTER LOCATIONS OBTAINED FROM FIELD MEASUREMENTS.. THE LOCATION AND QUANTITY OF ATTACHMENTS MAY VARY BASED ON RAFTER LAYOUT START POINT, SPACING VARIATIONS AND ROOFING TYPE. VERIFY IN THE FIELD ALL RAFTER LOCATIONS AND ADJUST LAYOUT AS REQUIRED. A TILE ROOF WILL PRODUCE A STAGERED ATTACHMENT LAYOUT BECAUSE OF EXISTING STAGERED TILE JOINT LOCATIONS 3. EXISTING RESIDENCE EQUIPPED WITH SMOKE/CO DETECTOR IN AND OUTSIDE OF ALL SLEEPING ROOMS HARDWIRED AND INTERCONNECTED AS PER FEDERAL LAW - V\/V I V 1 1 IL 1 /-ILIIV I%J 1 1 1 JI I/- 11YV 29 180 270° 95% momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING `���,• ,,�CENSF •.� � i No PE86753 .p 4' _ 0 STATE OF 4 ON ONAL \E?C� ►►iiii1 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 334041 on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies CLAMPING MAX SPACING IN ZONE 1 48" O.0 AND IN ZONE 2 AND ZONE 3 24" O.0 SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION SYMBOL LEGEND TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 MSP MAIN SERVICE PANEL ® CHIMNEY SP SUB -PANEL SKYLIGHT PV SYSTEM INFORMATION OM UTILITY METER ® VENT SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-GIO+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US SOLAR AC D15C SOLAR AC DISCONNECT p PIPE VENT UDC UTILITY DISCONNECT FAN LC LOAD CENTER SATELLITE DISH PROJECT INFORMATION INITIAL DATE: 2/10/2022 DESIGNER:SN N3R NEMA 3R BOX W/ ENVOY-S ® FIRE SETBACKS REV: DATE: DESIGNER: CB COMBINER BOX MIN 3'x3' GROUND ACCESS POINT REV: DATE: DESIGNER: SITE PLAN MODULE PITCH DIRECTION P V - 2 WIND PRESSURE ZONE LINES THE IDEAL SOLUTION FOR: ctRooftoP " 'I", residential buildings Engineered in Germany MECHANICAL SPECIFICATION Format 1717mm x 1045mm x 32mm (including frame) a2mm 0°3b Weight 19.9 kg Front Cover 3.2 mm thermally pre -stressed glass with antl-reflectlon technology } .o,aww„s eaa..aemm r a. to I a.o, Back Cover Composite film Frame Black anodised aluminium Cell 6 x 20 monocrystalline Q.ANTUM solar half cells Junction box 53-101mm x 32-60mm x 15-18 mm Protection class IP67, with bypass diodes Cable 4mm2 Solar cable;(+) a1150mm, (-) a1150mm Connector Staubll MC4; IP68 ammlO~Ie.smm Quality ELECTRICAL CHARACTERISTICS Controlled PV POWER CLASS 350 355 360 365 370 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE+5 W /-0 W) 1prPVT� Power at MPP' Paw [W] 350 355 360 365 370 www.tuv.com Short Circuit Current' Isc [A] 10.97 11.00 11.04 11.07 11.10 ID 1111232615 E Open Circuit Voltage' Vpp IV] 41.11 41.14 41.18 41.21 41.24 Current at MPP I.. [A) 10.37 10.43 10.49 10.56 10.62 MGIRMA 'MYRVoltage at MPP Vaw IV] 33.76 34.03 34.31 34.58 34.84 ST TOP BRAND PV Efficiency' n [%] >_19.5 >_19.B >2D.1 >_20.3 >_2D.6 OER �I ' MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' 1v 'aoyr Power at MPP Paw (W] 262.6 266.3 270.1 273.8 277.6 2 221 E Short Circuit Current I� [A] 8.84 8.87 8.89 8.92 8.95 Warranty Q CELLS E ,«,��sea..a°,,,�c yield sacudry - Open Circuit Voltage V_ IV] 38.77 38.80 38.83 38.86 38.90 Current at MPP I.. [A] 8.14 8.20 8.26 8.31 8.37 Voltage at MPP Vaw IV] 32.24 32.48 32.71 32.94 33.17 'Measurement tolerances Paw :3%; Iso; Vc� x5% at STC: 1000 W/m2, 25t2'C, AM 1.5 according to IEC 60904-3.2800 W/m2, NMOT, spectrum AM 1.5 BREAKING THE 20 % EFFICIENCY BARRIER O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE Q.ANTUM DUO Z Technology with zero gap cell layout y ----, ii At least 98%of nominal power dur- � i ' > x,.....� --boostsmoduleefficienc u to 20.9%. UW mgnra Thereaftermaxt93.5Y P rear.------------ degradation per year. At least 93.5% u, of nominal power up to 10 Years. At s xao THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY 3 least 86% of nominal power up to tb �_ Q CELLS is the first solar module manufacturer to pass the most comprehen- Wo zsyears. Q sive quality programme in the industry: The new "Quality Controlled PV" of the All data within measurement toler- p v�r ancindependent certification institute TUV Rheinland. es. Full warranties in accordance 00 Pe with the warranty terms of the a0° t00° Uu Q CELLS sales organisation of your 800 IRRADI-EIW/mx7 INNOVATIVE ALL-WEATHER TECHNOLOGY m YE111 respective country. Typical �%- Optimal yields, whatever the weather with excellent oma module TCperconditions under low irradiance conditions in �"� ' comparison to STC conditions(25°C, 1000W/m2). ` low -light and temperature behaviour. TEMPERATURE COEFFICIENTS Temperature Coefficient of lae a [%/K] +0.04 Temperature Coefficient of Voc D [%/K] -0.27 - ENDURING HIGH PERFORMANCE Temperature Coefficient of PaEE Y [%/K] -0.34 Nominal Module Operating Temperature NMOT [^Cl 43±3 Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.Q-. PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vsys IV] 1000 PV module classification Class 11 EXTREME WEATHER RATTING Maximum Reverse Current le [A] 20 Fire Rating based on ANSI/UL 61730 C/TYPE2 High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). Max. Design Load, Push/Pull [Pa] 3600/2660 Permitted Module Temperature-40°C-+85°C Max. Test Load, Push/Pull [Pal 5400/4000 on Continuous Duty A RELIABLE INVESTMENT g� Inclusive 25-year product warranty and 25-year QUALIFICATIONS AND CERTIFICATES linear performance warranty2. Quality Controlled pV -TUV Rheinland; IEC 61215:2016; IEC 61730:2016. ' APT test conditions according to IEC /TS 62804-1:2015, method A(-1500V, 96h) Tni,detasheet complies ro w 2 See date sheet on rear for further information. Witt, DIN EN 50380. (\ QCPv Certification oN.irg. mxx„xxmn Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Menwha f3 CELLS OmbN Sonnenallee 17-21, 06766 Bitterfeltl-Wolfen, Germany I TEL+49 (0)3494 66 99-234441 FAX +49 (0)3494 66 99-230001 EMAIL seles@q-cells.com I WEB www.q-cells.com Q CELLS I Engineered in Germany QCELLS momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING ```xx%%IIIIII///// .� A Mq �P ..... %GENs i No PE86753 _- 06 7C 4: , 0 STATE OF F�ORIDP'. ONAL \E?C� 111111 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 334041 on the Date and Time Stamr shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I I INITIAL I DATE: 2/10/2022 I DESIGNER: SN I IREV: IDATE: IDESIGNER: IREV: IDATE: IDESIGNER: PANEL SPECIFICATION PV-3 QCELLS Document issue date: 2021-02-19 This authorization document ("Authorization Document") is issued and released by Hanwha Solutions Corporation on behalf of the respective warrantor as named in the Hanwha Q CELLS Limited Warranty for crystalline photovoltaic modules ("Warranty"). 1. We hereby confirm that the MODULE TYPE mounted in the CLAMP POSITION referenced in Table A, is in compliance with the requirement of UL1703/61730, and has successfully passed a pull test load of 4000 Pa and a max pull load of 5400 Pa in accordance with the UL 61730 standard Table A. OF CLAMP TEST LOAD [Pa] DESIGN LOAD [Pa] MODULE TYPE MOUNTING OPTION POSITION [mm] (Push /Pull) (Push /Pull) Q.PEAK DUO BLK-G6+/HL Clamping at long 250 — 350 +5400 / -5400 +3600 / -3600 Q.PEAK DUO BLK-G6+/AC modules sides (9.84 -13.78 in) (112.8 psf) (75.2 psf) Q.PEAK DUO-G6+/AC ("CL1") NOTE: Distance between outer edge of module and middle of the clamp The stability of the mounting system including the clamps and fixation of the modules must be secured by a certified system supplier. 2. As long as you adhere to the terms and conditions of this Authorization Document and the Warranty, the MODULE TYPE, mounted and clamped as instructed in the installation manual, shall be covered by the Warranty 3. Please note that no revisions are made to the existing terms of the Warranty. The terms of the Warranty shall remain AS IS, except as specifically referenced in this Authorization Document 4. The Warranty shall not apply to damages of the solar module backsheet and junction box caused by the mounting subconstruction. 5. Customer may not transfer, assign or delegate any of its rights or obligation hereunder to any other person, without the prior written consent of Hanwha Solutions Corporation 6. Any information contained in this Authorization Document is confidential and no part of this Authorization Document may be reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of Hanwha Solutions Corporation Q CELLS is a brand of Hanwha Solutions Corporation. Hanwha Solutions Corporation 23F, 86 Cheonggyecheon-ro,Jung-gu, Seoul,Korea 04541 T. +82 (0)2 6049 0520, F: +82 (0)2 729 1372, W: \ w .q-cells.com 0 momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING `- 0CENSF i No PE86753 0 STATE OF ONAL \E?C� /111111 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 334041 on the Date and Time Stamr shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I [INITIAL [ DATE: 2/10/2022 I DESIGNER: SN [ IREV: IDATE: IDESIGNER: REV: IDATE: IDESIGNER: PANEL LOAD TESTING RESULTS PV-3.1 Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters V� To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro'" and Enphase IQ 7+ MicrOTM dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy', Enphase IQ Battery'", and the Enphase Enlighten' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. nENPHASE Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US I07PLUS-72-2-US/I07PLUS-72-9-US Commonly used module pairings' 235 W - 350 W + 235 W -440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Micrainverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range2 240 V / 208 V / 240 V / 208 V / 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycler 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6 % 97.6 % 97.5 % 97.3 % CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % MECHANICAL DATA Ambient temperature range -400Cto+650C Relative humidity range 4%to 100%(condensing) Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4: order ECA-S20-S22 - PV2 to UTX: order ECA-S20-S25 Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 Ids) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at httos://enphase.com/en-us/support/module-como�atibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com n E N P H AS E @ 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 isino�z_l-e, SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING `��� . �r,CENSF •.� � I No PE86753 00 4:, ��0 STATE OF ONAL \E?C� /fi'111\ Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 334041 on the Date and Time Staml shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I I INITIAL I DATE: 2/10/2022 I DESIGNER: SN I IREV: IDATE: IDESIGNER: IREV: IDATE: IDESIGNER: INVERTER SPECIFICATION PV-3.2 Data Sheet Enphase Networking Enphase IQ Combiner 3 (X-IQ-AM1-240-3) U� LISTED To learn more about Enphase offerings, visit enphase.com The Enphase IQ Combiner 3TM with Enphase IQ Envoy'" consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy- printed circuit board for integrated revenue grade PV X-10-AM1-240-3 Droduction metering (ANSI C12.20+/- 0.5%) and optional* consumption monitorina (+/- 2.5%). Enphase Mobile Connect' CELLMODEM-03 (4G/1 2-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-M1 (4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring* CT Split core current transformers enable whole home consumption metering (+/- 2.5%). CT-200-SPLIT • Consumption monitoring is required for Enphase Storage Systems Wireless USB adapter Installed at the IQ Envoy. For communications with Enphase Encharge' storage and Enphase COMMS-KIT-01 Enpower' smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner'" and allows redundant wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker, 2 pole,10A, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole,15A, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid) 65 A Max. fuse/circuit rating (output) 90 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Smart Max. continuous current rating (input from PV) 64 A Includes IQ Envoy for communication Max. total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker included and control Production Metering CT 200 A solid core pre -installed and wired to IQ Envoy Flexible networking supports Wi-Fi, MECHANICAL DATA Ethernet, or cellular Dimensions (WxHxD) 49.5 x 37.5 x 16.8 cm (19.5" x 14.75" x 6.63"). Height is 21.06" (53.5 cm with mounting brackets). Optional AC receptacle available for PLC Weight 7.5 kg (16.5 Ibs) bridge Ambient temperature range -40° C to+46° C (-400 to 115° F) Provides production metering and optional consumption monitoring Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors Simple 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Reduced size from previous combiner Neutral and ground: 14 to 1/0 copper conductors Centered mounting brackets support single Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) stud mounting INTERNET CONNECTION OPTIONS Supports back and side conduit entry Integrated Wi-Fi 802.11b/g/n Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) 80 A total PV or storage branch circuits Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE-M) (not included) COMPLIANCE Reliable Durable NRTL-certified NEMA type 31R enclosure Five-year limited warranty UL listed Compliance, Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 To learn more about Enphase offerings, visit enphase.com 02018 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3, and other trademarks or service names are the � E N P H A S E trademarks of Enphase Energy, Inc. E N P H A S E `/ 2019-11-04 isino�z_l-e, SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING `���,• ,,r,CENSF ••� ♦ No PE86753 0 STATE OF ONAL \E?C� /111111 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 334041 on the Date and Time Staml shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I I INITIAL I DATE: 2/10/2022 I DESIGNER: SN I IREV: IDATE: IDESIGNER: IREV: IDATE: IDESIGNER: MBINER BOX SPECIFICATIO PV-3.3 DESCRIPTION: JUNCTION BOX XL FOR RAIL DRAWN BY: mwatkins ��������� DESCRIPTION: JUNCTION BOX XL FOR RAIL DRAWN BY: mwatkins nn 5 i1�`�i1Ora& REVISION: Solar Mounting Solutions REVISION: Solar Mounting Solutions PART NUMBER(S): A 595 MARKET STREET, 28TH FLOOR • SAN FRANCISCO, CA .105 USA PART NUMBER(S): A 585 MARKET STREET, 29TH FLOOR • SAN FRANCISCO. CA 941 OS USA 242-92120 PHONE (415) SOM900 • FAX (415) 580-6902 RE%tOWCTION,DISCLOSURE,OR USE THEREOF IS PROx131TED WITROUTTRE EN CON—Ta SUNKN SOUTH LLC. 242-92120 PHONE (415) 5806900 • FAX (415) 5868902 THE MFORMATOrvIN THISDMWIrvG IB CONFIDExTIuuiOOROFRIETMv. wNT REPRODUCTION. LOSURE, ORUBE THEREOF IS PROHI&TED WITMUT THE 2.56 5.00 .80 �n 2.058011,41— 4.43 5.75 2 88 7.629 05.75 7.36 j 1 ® 2.88 BOB 10.11 9.86 11.19 ®� 3 10.66 10.11 10.37 4.07 1.00 3.2 1.19 74 .50 5.00 ® 4 2 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, JUNCTION BOX XL (BARE) 2 2 SNAPNRACK, J BOX RAIL BRACKET 3 1 BOLT, FLANGED HEX, 5/16IN-18 X 1-1/4IN, SS 4 1 SNAPNRACK CHANNEL NUT 5/16IN-18 MATERIALS: POLYCARBONATE, CLOSED CELL FOAM, ALUMINUM, STAINLESS STEEL DESIGN LOAD (LBS): N/A ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 5 (CHANNEL NUT), 3 (LID) LB -FT CERTIFICATION: UL50/UL50E, NEMA 4X RATING 3.80 ALL DIMENSIONS IN INCHES WEIGHT (LBS): momentum • •' PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N3 (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING ````11111111/11/'' o No PE86753 '0 4: 0 STATE OF 4(- ............ A�ORIDP'.•' ��� �! '���Sis��NAL lE� ��♦ /llllll Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I I INITIAL I DATE: 2/10/2022 1 DESIGNER: SN I ROOF JUNCTION BOX SPECIFICATION FOR LOW-SLOPE/TILE/METAL/CONCRETE ROOF REV: DATE: DESIGNER: REV: DATE: DESIGNER: JUNCTION BOX SPECIFICATIONI PV-3.4 /A PUN VIEW, COMP ASSEMBLY, PO—'- MODULE Sole: I"=1'-0" END CAP AND CLAMP ROOF SURFACE L FOOT G E PV MODULE ) RAIL 1.l MID CLAMP \ L13 MAX. L \ (` FRONT VIEW, COMP ASSEMBLY, PORTRAIT MODULE Scale: 1"=1'-0" (g SIDE VIEW, COMP ASSEMBLY, PORTRAIT MODULE Scale: 1"=1'-O" (rPVMODUUEFRAME MID CLAMP D DEfAI4 MID CLAMP PLAN Scale: 6"=I'-0" END CAP PV MODULE FRAME t END CLAMP �1 DEfAI4 END CAP AND CLAMP PLAN Scale: 6"=1'-0" Ifl MID CLAMP W MODULE FRAME RAILS E DET MIO CIAMP FRONT *E"DLAMP PV MODULE FRAME END CAP RAILS (1 DEFAIL. END CAP AND CLAMP FRONT Sole: 6"=1'-0" IN 1/2" PLYWOOD LOAD DIRECTION FOS=2 FOS=3 UPLIFT 345 230 LATERAL.PERP. TO SLOT 1 1401 95 LATERAL.PARALLELTO SLOT 1 2651 175 IN 7116" OSB LOAD DIRECTION FOS=2 FOS=3 UPLIFT 190 125 LATERAL.PERP. TO SLOT 125 85 LATERAL.PARALLEL TO SLOT 1351 90 PORTRAIT NOTES Factor of Safety as shown Torque at 3/8" T-Bolt = 15ft.lbs (20 N.m) All loads in pounds force Values valid only for conditons equal or better than test conditions Values valid only when product is used in accordance with SunModo installation instruction and other technical documentation * The kit as shown in the BOM. For alternative configurations, contact SunModo 4 1/4" Deck Screws in Min 7/16" OSB B15018-001 HEX CAP SCREW 3/8-16 X 3/4 C50001-001 GASKET, EPDM, WITH ADHESIVE B15003-001 IFLANGE NUT 318-16 B15039-001 HEX WASHER HEAD LAG BOLT 1/4X3 A50224-001 METAL ROOF DECK MOUNT PART NUMBER DESCRIPTION C SEE ES SunModo Corp. 14800 NE 65TH STREET, VANCOUVER WA 98682 P-0-i- len�"": Nin1°'"""°I 152ammi °aml Le METAL ROOF DECK MOUNT KIT ioiisi201a B Awwc num aEK50532-001 STRUCTURE SCALE: NONE SHEET 1 of 1 Company Feb 19, 2021 Designer 06.43 AM Job Number: Checked By:_ Section Properties: Sectionl_450124 (REVX03).DXF Section Information: Matenal Type = General Shape Type = Arbitrary Number of Shapes = 1 Basic Properties: Total Width = 1.575 in Total Heigh = 1.675 in Centroid, Xo = 0.ODO in Centmid, Yo = 0.785 in X-Bar(Right) = 0.787 in X-Bar(Left) = 0.787 in Y-Bar(Top) = 0.788 In Y-Bar (Sot) = 0.786 in Max Thick Equivalent Properties: Area, Ax = 1.675 = 0.373 in W2 Inertia, Im = 0.151 in14 Inertia, lyy 0.100 i14 Inertia, Ixy - -0.000 in14 Sx(TOP) = 0.191 in-3 Six(BoU = 0.191 in-3 BY(LeR) = 0.126 inA3 By (Right) = 0.128 in-3 nr = 0.635 in ry = 0.518 in Plastic Zx = 0.222 in-3 Plastic Zy 0.180 in-3 Torsional J - <No Cal- AsDef = 1.0D0 As yy Def = 1.000 As-xz Stress = 1.DD0 As-yy Stress = 1.OD0 Section Diagram C:\RISA\SectionProjecti Page 2 30 of 31 SUNM* ^:3 EZ GRIP METAL DECK MOUNT Make your next metal roof attachment without the daunting task of locating the truss. SunModo's EZ Grip Metal Deck Mount installs into 26 gauge sheet metal, 1/2 plywood or 7/16 OSB roof decking material. SunModo's EZ Grip Metal Deck Mount installs in just minutes into sheet metal, plywood or OSB roof decking. The four included 1/4 x 3" Hex Washer Head Self -tapping Screws have the length to penetrate though 1-1/2 inches of insulation while still piercing completely through the roof decking. And since the four screws are guided by the aluminum extruded base to penetrate at a 3o-degree angle, the Metal Roof Deck Mount Kit offers superior attachment performance. 1/4-20 Self -drilling screws can be used for attachments into 26 gauge minimum thickness metal roofs. The EZ Grip Metal Deck Mount is designed to fit on the most popular R-Panel and U-Panel _ trapezoidal types of metal roofs. The aluminum extruded base easily clears roof profiles 7/16" tall by 1-1/2" wide. The EPDM gaskets on the _ washers and on the aluminum extruded base combine to provide a water tight seal at the roof penetration site. Features and Benefits • Attaches into 1/2 plywood or 7116 OSB roof decking material using four 1/4 x 3" Hex Washer Head Self -tapping Screws • Attaches into 26 gauge minimum thickness sheet metal using four 1/4 x 2" Hex Washer Head Self -drilling Screws • Angled penetrations provide superior attachment performance • A wide variety of L-feet and attachment options are available • Passed the High -Velocity Hurricane Zone (HVHZ)-TAS ioo(a) Wind -Driven Rain Test SunModo Corp I Vanaouvar, WA 1360-844-0048 Document Number D10153-VO03102019 - SunModo Corp. SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING .� A �P ..... 0- • ,,�CENSF i No PE86753 00 4:, 0 STATE OF F4ORI0Qa. Sis/ONAL 0111111\ Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Starn shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I I INITIAL I DATE: 2/10/2022 I DESIGNER: SN I IREV: IDATE: IDESIGNER: IREV: IDATE: IDESIGNER: ATTACHMENT DETAIL ATTACHMENT DETAIL FOR CORRUGATED METAL ROOF PV-3.5 ALLOWABLE LOAD / ATTACHMENT 5/16" LAG SCREW W/ 3.00" EMBEDMENT INTO RAFTER BELOW ACCORDING TO THE NATIONAL DESIGN SPECIFICIFICATION FOR WOOD CONSTRUCTION 2015 EDITION. = W' = W X CD X CT. - PER TABLE 11.3.1 NDS 5/16" DIA. 4" LONG LAG W/ 3.00" EMBEDMENT INTO 2X ROOF RAFTER W' = 266LB/IN (NDS11.3.1 TABLE 12.2A) FOR DF. LARCH, S.Y.P., AND S.P.F. SPECIES CD = 1.6 (TABLE 2.3.2 2015 NDS), CT = 1.0 (TABLE 10.3.4 2015 NDS) W' = 266LB/IN X 3.00" X 1.6 X 1.0 = 1,276.8LBS = ULTIMATE MAX ALLOWABLE UPLIFT PRESSURE WITH 60% OF ULTIMATE CAPACITY 1,276.8LBS X 0.6 = 766.08LBS -THREAD MUST BE EMBEDDED IN THE SIDE GRAIN OF A TRUSSES OR OTHER STRUCTURAL MEMBER INTEGRAL WITH THE BUILDING STRUCTURE. -LAG BOLTS MUST BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER. -THESE VALUES ARE NOT VALID FOR WET SURFACE. -INSTALL LAG BOLTS WITH HEAD AND WASHER FLUSH TO SURFACE (NO GAP). TORQUE AS PER MANUFACTURERS SPECIFICATIONS. DO NOT OVER -TORQUE. -WITHDRAWAL DESIGN VALUES FOR LAG SCREW CONNECTIONS SHALL BE MULTIPLIED BY APPLICABLE ADJUSTMENT FACTORS IF NECESSARY. SEE TABLE 10.3.1 IN THE AMERICAN WOOD COUNCIL NDS FOR WOOD CONSTRUCTION. WIND PRESSURE ZONE CALCULATION (ASCE FIGURE 30.4-2A, 2B) HORIZONTAL DIMENSION A 44.0400009155273' X 10% = 4.40400009155273' HORIZONTAL DIMENSION B 56.599998474121' X 10% = 5.6599998474121' BUILDING HEIGHT 15' X 40% = 6' PRESSURE ZONE WIDTH 4' 4.85 " 10 % OF LEAST HORIZONTAL DIMENSION OR 40% OF THE BUILDING HEIGHT WHICHEVER IS SMALLER BUT NOT LESS THAN EITHER 4% OF THE LEAST HORIZONTAL DIMENSION OR 3'-0" WIND LOAD CALCULATIONS (ASCE 7-16 EQ. 29.4-7) VELOCITY PRESSURE Qh = 0.00256 Kz*Kzt*Kd*Ke *VA 2(LB/SQFT) (EQ. 26.10-1) DESIGN LOAD CRITERIA. AS PER ASCE 7-16 (2.4.1) FOR THIS PARTICULAR CASE, THE "DOWNFORCE" CASE 2 AND UPLIFT HAVE BEEN TAKEN INTO CONSIDERATION. P (PSF) = 1xD + 1x PNET (DOWNFORCE) P (PSF) = 0.6xD + 0.6x PNET (UPLIFT) (P = TOTAL DESIGN LOAD) (PNET = WIND LOAD) (D = DEAD LOAD) PNET HAVE BEEN CALCULATED FOLLOWING THE ALLOWABLE STRESS DESIGN METHOD. THE MAXIMUM ABSOLUTE VALUE OF THE 2 CASES IS THE UPLIFT LOAD. THIS 2-RAIL DESIGN IS WELL UNDER THE CAPACITY OF THE INDIVIDUAL ATTACHMENT CAPACITIES FOR THE DESIGN. THE PHOTOVOLTAIC MODULES USED IN CONJUNCTION WITH 2-RAIL ATTACHMENT SYSTEM ADDED HAVE A DESIGN CAPACITY OF -4,000 PA., 84 PSF. THIS DESIGN IS WITHIN THE LOADING CAPACITIES OF THE PHOTOVOLTAIC MODULE 2-RAIL DESIGN TESTING CAPACITIES THAT HAVE BEEN PERFORMED BY INDEPENDENT TESTING BY THE PANEL MANUFACTURERS ENGINEERS. SEE ATTACHED MANUFACTURERS TEST DATA. WIND PRESSURE PNET IS CALCULATED BY ASCE 7-16 EQ. 29.4.7, WHERE Qh IS CALCULATED BY EQ. 29.4-7 (PARAMETERS SHOWN IN THE TABLE). GCp ARE CHOSEN FROM FIGURE 30.3-A-1 FOR SPECIFIC ROOF TYPE AND ROOF TILT WITH EFFECTIVE WIND AREA EQUALS TO 10 SQFT (INTERPOLATION MAY REQUIRED). ARRAY EDGE FACTOR rE = 1.5 FOR ARRAY EDGES UPLIFT PRESSURE IF ARRAY EDGE IS MORE THAN 10 FEET (0.5h) TO ROOF EDGES AND MORE THAN 4 FEET TO ADJACENT ARRAY OR NEXT ADJACENT PANEL. rE = 1.0 FOR ARRAY INTERIOR UPLIFT PRESSURE AND ALL DOWNWARD PRESSURE AS DEFINED IN ASCE 7-16 29.4.4. NO PANEL ARE LOCATED IN ARRAY EDGE AREA AS DEFINED BY ASCE 7-16 29.4.4. FOI EXPOSURE B THIS PROJECT. V (WIND SPEED) 175 MEAN HEIGHT 15.00 2-RAIL RACKING PLUS SOLAR SYSTEM DEAD LOAD COMPONENT WEIGHT/UNIT (LB) # EFFECTIVE WIND AREA (AREA OF ONE PANEL) 19.29 Kz (VELOCITY PRESSURE EXPOSURE) 0.57 MODULES 0 29 Kzt (TOPOGRAPHIC FACTOR) 1 INVERTERS 4.0 29 Kd (WIND DIRECTIONALITY) 0.85 RAILS (2-RAIL) @ 1.8LB/LF. 1.8 15.0 Ke (GROUND ELEVATION FACTOR) 1 ATTACHMENT/FLASHING 0.98 42 LF (LOAD FACTOR BASED ON ASD DESIGN) 0.6 ARRAY TOTAL AREA (SQFT) 559 Qh (VELOCITY PRESSURE) 22.98 ARRAY TOTAL WEIGHT (LB) 184 ra (SOLAR PANEL PRESSURE EQUALIZATION FACTOR) 0.69 TOTAL DEAD LOAD PER SF (LB/SQFT) 2.60 TOTAL PRESSURE AND ATTACHMENT SPACING FOR GABLE ROOF WITH 7 to 20 DEGREE TILT GCp p- (LB/SQFT) p+ (LB/SQFT) pnet- (LB/SQFT) pnet+ (LB/SQFT) ATTACHMENT SPACING (INCH) ZONE UPLIFT DOWNWARD ARRAY INTERIOR ARRAY EDGE ARRAY INTERIOR ARRAY EDGE ARRAY INTERIOR ARRAY EDGE 1 -2.00 0.30 -31.52 -47.28 4.73 -17.35 -26.81 7.33 48.00 24.00 2e -2.00 0.30 -31.52 -47.28 4.73 -17.35 -26.81 7.33 24.00 24.00 2n -2.59 0.30 -40.84 -61.27 4.73 -22.95 -35.20 7.33 24.00 24.00 2r -2.59 0.30 -40.84 -61.27 4.73 -22.95 -35.20 7.33 24.00 24.00 3e -2.59 0.30 -40.84 -61.27 4.73 -22.95 -35.20 7.33 24.00 24.00 3r 1 -3.09 1 0.30 1 -48.64 1 -72.96 1 4.73 1 -27.62 1 -42.22 1 7.33 1 24.00 1 16.00 ATTACHMENT LB ARRAY INTERIOR ARRAY EDGE -195.50 -151.02 -97.75 -151.02 -129.27 -198.29 -129.27 -198.29 -129.27 -198.29 -155.61 -158.54 0 momentum SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING `\\j\111111//1/// A. MA %CENS No PE86753 Q STATE OF FALORIDP' •' ��� 01 II Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US PROJECT INFORMATION ITIAL DATE: 2/10/2022 DESIGNER: SN V: DATE: DESIGNER: V: DATE: DESIGNER: STRUCTURAL CALCULATION PV-3.6 TOPCOAT' LIQUID -APPLIED ROOFING FLEXSEALm CAULK GRADE Description TOPCOAT® FlexSeal'" Caulk Grade is a white solvent - based synthetic elastomeric sealant. FlexSeal" Caulk Grade is extremely flexible and durable, but with a higher viscosity formulation than standard viscosity FlexSeal-. Like all solvent -based products, the surface must be clean and completely free of moisture and residual contaminants before application. FlexSeal'" Caulk Grade is especially suited for use in any application where caulk is typically used. If a more fluid viscosity is desired, FlexSeal'" is also available in both a standard viscosity as FlexSeal' and a low -viscosity version as FlexSeal- LV. Uses TOPCOAT FlexSeal" Caulk Grade is designed for use on metal, copper, concrete, wood, asphalt shingles, SBS, APP, EPDM, BUR, TPO, and PVC substrates. Especially designed for use where elastomeric caulks are required, like term bar applications or around clamping rings at penetrations. FlexSeal- Caulk Grade may be used for cold -weather applications provided that the material is stored properly and the substrate is dry prior to application. This product is easiest to apply at temperatures above 32°F (0°C). Substrate temperatures must be below 120°F (48.9°C) when applying product. Advantages • Extremely flexible and durable • Ideal for termination bar, railing, step flashings, or edge metal • Durable and UV resistant; will not chalk, crack, or peel • Joint movement capability maximum ± 25% • Bonds to multiple substrates including metal, copper, concrete, wood, asphalt shingles, SIBS, APP, EPDM, BUR, TPO, and PVC • Paintable • Limited material warranty available for up to 10 years* • May be used in guaranteed projects up to 20 years** • Available in 10-oz. cartridges For Application Questions Contact GAF Technical Services at 1-800-766-3411 or visit gaf.com. Applicable Standards FlexSeal'" Caulk Grade meets ASTM D412 and D920; and is tested in accordance with D2196 and D1475. Application Considerations FlexSeal'" Caulk Grade is not a structural component and it is not intended to bridge large voids. Joint depth should not exceed 1/2" wide by 1/2" deep (13 mm x 13 mm). If joint exceeds 112" (13 mm) deep, the sealant depth should be controlled by a closed cell backer rod. The number of joints and width of joints should be designed to accommodate a maximum of 25% movement. Note: Apply only as directed. Over -application may result in slumping, dripping, or unsightly appearance. Note: Repair leaks promptly to avoid adverse effects, including mold growth. "See applicable warranties and guarantees for complete coverage and restrictions. "When used as a part of a multiply system. TOPCOA71 FlexSeai �° Caulk Grade is a maintenance item and should be inspected periodically as a part of regular roof maintenance. TOPCOAT' FLEXSEAL' CAULK GRADE TECHNICAL DATA Application Rate: Approximately 1/4 -3/8 inch (6 - 10 mm) bead Application Method: Caulk gun Application Temp (air, surface): 32°F - 120°F (0°C - 48.9°C) Drying Time (varies by conditions): 24 - 48 hrs; skins in less than 1 hour; full cure - approximately 48 hours Total Solids (by weight): 77% ± 2% Specific Gravity: 1.24 ± 0.1 Weight per Gallon: 10.3 ± 0.5 Ibs Viscosity (75°F (23.9°C)): 1,200,000 cps ± 10% Tensile: >250 psi (>1.72 N/sq mm) Storage: Recommended storage temperature range 50oF-9OoF (10°C-32.2°C). Storage for continued periods outside this temperature range may shorten shelf life. Shelf Life: Approximately 1 year Clean -Up: Mineral Spirits, Toluene, Xylene =0 Product Data Sheets 35 SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING ```X11111IIII///// �P ..... t �� • %,%GENSF i No PE86753 �.0 4:, 0 STATE OF is1ONAI. E?C� //11111I Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Starn shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I I INITIAL I DATE: 2/10/2022 I DESIGNER: SN I IREV: IDATE: IDESIGNER: IREV: IDATE: IDESIGNER: SEALANT SPECIFICATION SEALANT SPECIFICATION FOR CORRUGATED METAL ROOFS PV-3.7 ELECTRICAL SERVICE ELEVATION INTERCONNECTION DETAIL 0 #2/0 AWG SERVICE momentum CONDUCTOR FROM MINUMUM BEND RADIUS 4" SOLAR • ° ° METER d RISER � OVERHEAD FOR HOT LINE TAPSMm ENCLOSURE DIMENSIONS .. • ° ° • • ° ' ' •, ' •MSP 200AMP SERVICE LENGTH: 21.31�� WIDTH: 10.3" PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ • • • •• % s ° ° r- -I s ° DEPTH: 9.06" (732)902-6224 MOMENTUMSOLAR.COM • • • • ° I ',�', • • • Inn PROFESSIONAL • a ® a ° ° °• « a• °I 'I ' #2/0 AWG SERVICE CONDUCTOR FROM ENGINEERING • •' A • I I '% UTILITY°,� 200AMP SERVICE • • • . ° • EMPHASE ° EXISTING ° COMBINER • ' SOLAR . • �MSP LOCATED IN SIDE A. • • • BOX oISCaN.E ' •°' •• .METE.R .: • ' : OF STRUCTURE �� • ', .4 �-♦ �,,cENsF I No PE86753 4' FSEC CERTIFICATION STATEMENT: Q STATE OF 29 HANWHA Q.PEAK DUO BLK-G10+ 360 360W MODULES PAIRED WITH PER FL. STATUE 377.705, I, MINA A. MAKAR PE# 86753, CERTIFICATE • ' ���� •!�40RIDOF PV SYSTEM CURRENT 36.25 A #33404, AN ENGINEER LICENSEDQ' TO ���/ssIONA1. 29 ENPHASE IQ7-60-2-US MICRO -INVERTERS CHA TER0ON 47I1 CEIR I Y THAT HE PV ELECTRICAL SYSTEM ANDANT "1111I III`` ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE Digitally signed by Mina A Makar. FLORIDA BUILDING CODE. FBC 2020 BRANCH CIRCUITA Reason : This item has been 10 MICRO -INVERTERS EXISTING SQUARE D 150A electronically signed and sealed by BRANCH CIRCUIT B MAIN SERVICE PANEL 240 V 10 MICRO -INVERTERS [Mina A. Makar, PE 86753, COA # BRANCH CIRCUIT C 9 MICRO -INVERTERS + - - + - + - - - MAIN BREAKER: 150A 334041 on the Date and Time Stamp ENPHASE I SIDE shown using a digital signature. AC COMBINER HOTT TAP BOX SOLAR CIRCUIT Printed copies of this document are TERMINATION CAP DISCONNECTING MEANS 150A not considered signed and sealed INSTALLED ON + - + - + - EATON 60A FUSIBLE GRID and the signature must be verified END OF CABLE - _ = SOLAR AC DISCONNECT on any electronic copies 4oA SOLAR CONTRACTOR CAMERON CHRISTENSEN ROOF 10A/15A BREAKER POWER UTILITY CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR INVERTERS JUNCTION (MANUFACTURER 40A FUSES GROUND METER 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION SUPPLIED FOR INS 1ATO 1C BOX 2A ENVOY) 3 4 RAIL SYSTEM 26 20A BREAKER (A) 2C 20A BREAKER (B) TONY PEREIRA - MS93764 20A BREAKER (C) 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire BLK-G10+ 360 Wire Tag Conduit Wire Qty Wire Type NOC (A) Gauge Rating Ampacity (A) Derate Fill Derate Ampacity (A) Qty Correction Current (A) Size Type 29 INVERTERS: ENPHASE IQ7-60-2-US 1A TO 1C OPEN AIR 3 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 10 1 1.25 12.50 06 AWG BARE CU 2A 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 10 1 1.25 12.50 PROJECT INFORMATION INITIAL DATE: 2/10/2022 DESIGNER:SN 2B 3/4" PVC 6 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 10 1 1.25 12.50 08 AWG THWN-2 REV: DATE: DESIGNER: 2C 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 9 1 1.25 11.25 REV: DATE: DESIGNER: 3 3/4" PVC 3 + G 08 AWG THWN-2 75'C 50 0.96 1 48.00 29 1 1.25 36.25 08 AWG THWN-2 THREE LINE DIAGRAM 4 3/4" PVC 3 + G 06 AWG THWN-2 75*C 65 0.96 1 62.40 29 1 1.25 36.25 THWN-2 ��_ "G" NOTE: LETTER IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. MODULE MAKE HANWHA MODEL Q.PEAK DUO BLK-G10+ 360 MAX POWER 360W OPEN CIRCUIT VOLTAGE 41.18V MPP VOLTAGE 34.31V SHORT CIRCUIT CURRENT 11.04A MPP CURRENT 10.49A NUMBER OF MODULES 29 UL1703 COMPLIANT YES INVERTER MAKE ENPHASE FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE 0 WIRE RUN VmP IMP R L (FT) VD 0/0 VO WIRE SIZE momentum MODEL IQ7-60-2-US SOLAR: BRANCH TO J-BOX 240.00 #NUM! 1.98 #NUM! #NUM! #NUM! 12 AWG MAX OUTPUT POWER CH 240W OPEN DC VOLTAGE 48V J-BOX TO LOAD CENTER 240.00 NOMINAL AC VOLTAGE 240V LOAD CENTER TO AC DISCONNECT 240.00 MAX AC CURRENT 1A AC DISCONNECT TO INTERCONNECTION 240.00 CEC INVERTER EFFICIENCY 97% NUMBER OF INVERTERS 29 WITH THE 2020 NATIONAL ELECTRICAL CODE 1703 COMPLIANT YES THIS SOLAR PHOTOVOLTAIC FLORIDA BUILDING CODE SYSTEM COMPLIES AND THE 2017 SUB PANEL # OF MODULES PB PER BRAN BREAKER SIZE UP TO 16 20A 0 1.24 50.00 0.000 0.00% 0 1.24 3.00 0.000 0.00% 0 1.24 10.00 0.000 0.00% MAKE MODEL VOLTAGE RATING CONDUCTOR RANGE MAIN ILSCO IPC 4020 600 V 4/0-4 AWG ILSCO IPC 4006 600 V 4/0-2 AWG 10 AWG 10 AWG CONDUCTOR RANGE TAP 6-14 AWG 2/0-6 AWG ELECTRICAL NOTES: 1. ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN 15. ALL CONDUCTORS MUST BE COPPER. 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED AC MODULES WILL COMPLY WITH 250.64. ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER COEFFICIENTS. NEC 250.24(C). 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.13, 690.15, 690.6. 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING GROUNDING ELECTRODE SYSTEM PER 250.54(D). 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY LUG USING #6 BARE COPPER WIRE OR #8 THWN-2 COPPER WIRE. WITH 705.12(A) OR 705.12(B) 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA 3. THIS SYSTEM COMPLIES WITH NEC 2017 DC. 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS SHALL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE COMBINER BOX SHALL BE SHOWN IN A SIMILAR FASHION 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 6. ALL EQUIPMENT INSTALLED IS RATED AT 75°C 7. INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(B) 11. PER NEC 690.13, 690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ *WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - OR EQUIVALENT. 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC705.12 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB -CIRCUIT BRANCHES IS ACCEPTABLE. 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 25. TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(A)(2). 26. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.6 - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. 690.6. INSTRUCTIONS FOR LINE TAPS FIGURE 1: 1. ADJUST THE CONNECTOR NUT TO SUITABLE LOCATION 2. PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY 3. INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A CERTAIN LENGTH OF THE FIRST INSULATED LAY FROM INSERTED END 4. TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN SUITABLE LOCATION. 5. SCREW THE NUT WITH THE SLEEVE SPANNER. 6. SCREW THE NUT CONTINUALLY UNTIL THE TOP PART IS CRACKED AND DROPPED DOWN PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING `\xj\IIIIII////// ` A• MA �� �•'' �. F '• .p No PE86753 0 STATE OF II Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Starn shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US PROJECT INFORMATION INITIAL DATE: 2/10/2022 DESIGNER: SN REV: DATE: DESIGNER: REV: DATE: DESIGNER: ELECTRICAL NOTES PV-4.1 I TAG LABEL QUANTITY LOCATION NOTE EXAMPLES momentum 1 AT EVERY SEPARATION BY SOLAR 0 • 12 AC CONDUITS ENCLOSURES / WALLS / PARTITIONS / CEILINGS / FLOORS AC SOLAR VOLTAGE OR NO MORE THAN 10' PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM WARNING: PHOTOVOLTAIC PHOTOVOLTAIC PROFESSIONAL © ' • •EQUIPPED WITH 1 COMBINER BOX 1 AT ANY COMBINER BOX RAPID SHUTDOWN ENGINEERING AWARNING \,%GEN SF i ©ELECTRICAL SHOCK_ No PE86753TERMINALS _ ON BOTH LINE AND 1 JUNCTION BOX 1 AT ANY JUNCTION BOXR, y wi,,- LOAD ■ - ■ IN THE OPEN POSITION 00 s = ••. . • 1131 ` iSTATE OF 4 i F40Rlop- PHOTOVOLTAIC SYSTEM AAC DISCONNECT i ONAI. RATED AC OUTPUT CURRENT ASHOCKHAZARD_ ELECTRICAL e TERMINALS ON BOTH LINE AND Digitally signed by Mina A Makar. • ■ ■ ■ _ -- Reason : This item has been Op VOLTAGENOMINAL AC IN THE OPEN POSITION AC DISCONNECT 1 OF EACH AT FUSED AC - '" electronically signed and sealed by (RSD SWITCH) DISCONNECT © [Mina A. Makar, PE 86753, COA # 010 ■ • • ' 1 RAPID SHUTDOWN COMPLETE VOLTAGE AND 33404] On the Date and Time Stamp SOLAR TO BE LOCATED CURRENT VALUES ON • shown using a digital signature. POWER TO THIS SERVICE AT AC DISCONNECT LABEL Printed copies of this document are DISCONNECT - ALSPHOTOVOLTAIC • ■ ' • • OUTSIDE THE not considered signed and sealed INSTALLED SOLAR GENERATION ,., ; BY MOMENTUM SOLAR • HOUSE 614 and the signature must be verified AC SYSTEM■ • 07080 ®� 0 on any electronic copies SOLAR CONTRACTOR • = CAMERON CHRISTENSEN REVENUEI METER - _ CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 � MOMENTUM SOLAR A 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 0 DUAL POWER SUPPLY 1 UTILITY METER.= CUSTOMER INFORMATION SECONDARY • 1 AT UTILITY METER ANC PHOTOVOLTAIC SYSTEM DIRECTORY PLACARD TONY PEREIRA - MS93764 @ 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 EMERGENCY RESPONDER© SOLARTHIS • -- ■ � 7724465444 PV SYSTEM INFORMATION RAPIDWITH SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE" OFF" POSITION TO SHUT DOWN .a E.E ENTIRE PV SYSTEM DUAL POWER SUPPLY 1 INTERCONNECTION POINT __ _ - I I SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO ■ _SECONDARY SOURCE BLK-G10+ 360 ■_PHOTOVOLTAIC 29 INVERTERS: ENPHASE IQ7-60-2-US 1 OF EACH AT BUILDING I . INTERCONNECTION POINT AND POWER SOURCEOUTPUT CONNECTION.-210 1 BACKFEED PANEL ONE DIRECTORY PLACARD _� . 135182e v >'' '' PROJECT INFORMATION INITIAL DATE: 2/10/2022 DESIGNER: SN • O ■ NOMINAL OPERATING AC VOLTAGE: 240V NOMINAL POOPERAWER MAXIMUM ,. e�uu��am ��■� REV: DATE: DESIGNER: REV: DATE: DESIGNER: EQUIPMENT LABELS _ MAXIMUM OVERCURRENTDEVICE FOR 1 AC CURRENT PV MODULES P V — 4 2 AC MODULE PROTECTION: 1 0 © BACKFEED ■ Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd. Skillman NJ. 08558 908-872-3664 StudioGdesign@comcast.net February 9, 2022 Re: Proposed Photovoltaic Solar Panel Installation Tony Pereira 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 Dear Plan Reviewer: Certification: I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer of Record, and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following recommendations: 1. The array will be installed on the existing roof. The roof ftaming is constructed of 2"x4" wood trusses @24" o.c. spanning 14' with a top chord length of 14' 9" with intermediate supports at 1/2 points, making the effective longest span equals 8' with 1/2" plywood sheathing. The new array (See Site map by contractor) will add 2.63 Lb. / Sf. overall to the roof. The existing structure is sufficient to support the new loads associated with the additional weight & wind resistance. No additional structural support is required for the roof structure. 2. The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 approved tested. Provide 6 mil. vapor barrier between dissimilar metals. Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual. The panel angle shall match the roof slope. Reference summary table below: Roof Type: Corrugated Metal Fastener Max Spacing (in.) Attachment System: "ROOFTECH"® "RT MINI 11" & "Ecol aster" Click Fit® Attachment Systems Please See Manufacture Specification and PV- min. 5/16" x 4" long stainless -steel lags with a min. Fastener Info: 3.6 embedment of 3" into the rafters 3. Solar Modules shall be UL-1703 rated. Refer to manufacturers specifications sheets. 4. Positive drainage of the system shall be so as not to void the existing roof warranty. 5. All aspects of the installation shall comply with the Florida Administrative Code, 2020 Florida Building Code - Residential Seventh Edition, ASCE-7-16, 2020 Florida Building Code - Energy Conservation, Seventh Edition, 2017 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. All components used meet the criteria of the Florida Solar Energy Center. 6. Please refer to the attached structural calculations. If you have any questions relating to this matter, please contact me at your earliest convenience. Thank you. Daniel W. Dunzik, RA. LEED-AP FL. Lic. No. AR98795 Daniel W. Dunzik 370 Burnt Hill Rd. Skillman NJ. 08558 StudioGdesign@comcast.net Gravity Load Calculation Criteria Structural Design Loads per ASCE 7-16 Dead Loads = 10 psf + 2.6 psf (new solar panels) = 12.6 psf Roof Live Load = 20 psf Ground Snow Load/Live Load = 0 psf Roof Slope = 18 degrees Basic Wind Speed = 160 mph Roof Mean Height = 15 R Exposure = B Wind Load Calculation Criteria Wind Loads per ASCE 7-16, Equation 29.4-7 Using an effective wind area of 10 SF, external pressure coefficient from Figure 30.3-A-I Array Interior: Array Edge: Zone 1 = -50.8 psf Zone 1 = -76.2 psf Zone 2e = -50.8 psf Zone 2e = -76.2 psf Zone 2n = -76.2 psf Zone 2n = -114.3 psf Zone 2r = -76.2 psf Zone 2r = -114.3 psf Zone 3e = -76.2 psf Zone 3e = -114.3 psf Zone 3r = -91.44 psf Zone 3r =-137.16 psf Per section 2.4.1, ASD combo = 0.613 + 0.6W: Array Interior: Zone 1 = 0.6 x 2.6 psf+ 0.6 x (-50.8 psf) = -28.92 psf Zone 2e = 0.6 x 2.6 psf + 0.6 x (-50.8 psf) = -28.92 psf Zone 2n = 0.6 x 2.6 psf + 0.6 x (-76.2 psf) = -44.16 psf Zone 2r = 0.6 x 2.6 psf + 0.6 x (-76.2 psf) = -44.16 psf Zone 3e = 0.6 x 2.6 psf+ 0.6 x (-76.2 psf) = -44.16 psf Zone 3r = 0.6 x 2.6 psf + 0.6 x (-91.44 psf) = -53.3 psf Array Edge: Zone 1 = 0.6 x 2.6 psf+ 0.6 x (-76.2 psf) = -44.16 psf Zone 2e = 0.6 x 2.6 psf + 0.6 x (-76.2 psi) = -44.16 psf Zone 2n = 0.6 x 2.6 psf + 0.6 x (-114.3 psf) = -67.02 psf Zone 2r = 0.6 x 2.6 psf+ 0.6 x (-114.3 psf) = -67.02 psf Zone 3e = 0.6 x 2.6 psf+ 0.6 x (-114.3 psf) = -67.02 psf Zone 3r = 0.6 x 2.6 psf+ 0.6 x (-137.16 psf) = -80.74 psf Check Attachment to Wood Truss Use 5/16 dia. Lag screw w/ 3" embedment into 2 in. wide roof rafter Please refer to design PV-3.6 and manufacturer specification for maximum allowable span. Architect LEED-AP 908-872-3664 February 9, 2022 isino�z_l-e, SOLAR PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, N3 (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING ````11111111111/'' A. No PE86753 .Q 4i Z 0 STATE OF ci is10NA1.1E ��♦ /111111 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Starn shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies SOLAR CONTRACTOR CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 CUSTOMER INFORMATION TONY PEREIRA - MS93764 409 NORTHEAST OLEANDER AVENUE PORT ST. LUCIE, FL 34952 7724465444 PV SYSTEM INFORMATION SYSTEM SIZE (DC): 10.44 KW 29 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 360 29 INVERTERS: ENPHASE IQ7-60-2-US I PROJECT INFORMATION I I INITIAL I DATE: 2/10/2022 I DESIGNER: SN I IREV: IDATE: IDESIGNER: IREV: IDATE: IDESIGNER: I UCTURAL CERTIFICATIO PV- 5