Loading...
HomeMy WebLinkAboutField Density Test Report�r Ard -nan & Associates, Certificate of Authorization No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, Florida 34986 Phone: (772) 878-0072 Fax: (772) 878-0097 FIELD DENSITY TEST REPORT RECEIVED NOV 0 6 2017 PERMITTING St. Lucie County, FL PROJECT: Morningside FILE NO.: 15-5434A REPORTED TO: Renar Homes DATE OF TEST: 10/31/2017 Permit No. 1707-0295 TEST House Pad at 9331 Breakers Row MDR MOISTURE CONTENT DRY PERCENT DEPTH NO. NO DENSITY COMPACTION LOCATION 1 Northwest Corner 1 15.8 111.1 96 0 to -1' 2 Southwest Corner 1 15.9 112.2 97 0 to -1' 3 Southeast Corner 1 14.3 109.8 95 , 0 to 4 4 Center 1 14.5 110.0 95 0 to A' 5 Northeast Corner 1 14.4 111.4 96 0 to -1' * DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT FIELD TEST: �j ASTM D-2937 ASTM D-6938 �I ASTM D-2167 r i ASTM D-1556 TECHNICIAN: CIF Test depth referenced from: LABORATORY MOISTURE -DENSITY RELATIONSHIP Top of House Pad MDR ASTM MAX. OPTIMUM NO. TEST METHOD DENSITY MOISTURE CONTENT 1 D-1557 115.5 PCF 10 % Remarks: o STATES 0fLOW AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBM&9,,gYq(�R� FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING 0 RTS &RE VallaEk, P.E. PERTYn0FeCL11EFNS lfLRIZA'TIOPENDING OUR WRPy