HomeMy WebLinkAboutField Density Test Report�r Ard -nan & Associates,
Certificate of Authorization No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, Florida 34986
Phone: (772) 878-0072
Fax: (772) 878-0097
FIELD DENSITY TEST REPORT
RECEIVED
NOV 0 6 2017
PERMITTING
St. Lucie County, FL
PROJECT: Morningside
FILE NO.: 15-5434A
REPORTED TO: Renar Homes
DATE OF TEST: 10/31/2017 Permit No. 1707-0295
TEST
House Pad at 9331 Breakers Row
MDR
MOISTURE
CONTENT
DRY
PERCENT
DEPTH
NO.
NO
DENSITY
COMPACTION
LOCATION
1
Northwest Corner
1
15.8
111.1
96
0 to -1'
2
Southwest Corner
1
15.9
112.2
97
0 to -1'
3
Southeast Corner
1
14.3
109.8
95 ,
0 to 4
4
Center
1
14.5
110.0
95
0 to A'
5
Northeast Corner
1
14.4
111.4
96
0 to -1'
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF
95 PERCENT
FIELD TEST: �j ASTM D-2937 ASTM D-6938
�I ASTM D-2167 r i ASTM D-1556
TECHNICIAN: CIF
Test depth referenced from:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
Top of House Pad
MDR ASTM MAX. OPTIMUM
NO. TEST METHOD DENSITY MOISTURE
CONTENT
1 D-1557 115.5 PCF 10 % Remarks:
o STATES
0fLOW
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBM&9,,gYq(�R�
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING 0 RTS &RE
VallaEk, P.E.
PERTYn0FeCL11EFNS
lfLRIZA'TIOPENDING OUR WRPy