Loading...
HomeMy WebLinkAboutElectrical DetailJUL ; ? @ oll4' PE MI�Ti"9G St. Lucie (XlLinty, FL STADMESS S= HANDRm IAMB BONDING FOR LADDER) ANCHOR WITH $8 SOLID COPPER BOND WIRE WITH APPROVED CLAMPS F8 SOLID COPPER BOND WIRE WITH APPROVED CLUMPS LIGHT NH2{B ELECTRICAL EQUIPMENT WIRING, GROUNDING AND INSTALLATION MUST CONFORM TO THE 2011 N.E.C. AND APPLICABLE LOCAL CODES 18'MIN-24'MAX ENTIRE PERIMETER 4 967_y�% I-#B SOLID BARE COPPER CONT. PERIMETER BOND WIRE WITH APPROVED CLADS 4" TO 6' BELOW SUB -GRADE BOND TO EQUIPMENT ALL-INGROUND POOLS I-J8 SOLID BARE COPPER BOND WIRE WITH APPROVED CLAWS 0 (4) SIDES OF GUNITE POOLS BOND TO POOL STEEL EQUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTION OF THE N.E.C. 2011 SEC. 680.26 12 BLIGHT OPTIONAL 2ND LIGHT TRANSFORMER JUNCTION-BOX(S) MIN OF B" ;WATER OOL TIMER W/SJ. J H ABOVE POOL DECK r OGGLE-SWITCH L G.F.I. T L DECK POOH N.E.C. APPROVED 1" PVC CONDUR:MUST PROOF NOT BE THAN 20'FROEDGE AND NOT3-112 IN WITHIN 6' OF 1/2' CONDUIT N.E.C. 2011 SEC. 660.22(3) ELECTRICAL DETAIL NOTE- ALL ELECTRICAL WORK SHALL CONFORM TO N.E.C. 2011 SEC. 680