Loading...
HomeMy WebLinkAboutField Density Test Report�Aran & Associates Certificate of Authorization No. 5950 460 NW Concourse Place, Unit 1 R ECEIVED Port St. Lucie, Florida 34986 Phone: (772) 878-0072 Fax: (772) 878-0097®V 0 s 7��7 FIELD DENSITY TEST REPORT LucPERMITTINGeunty, St. Lucie County, FL PROJECT: Morningside FILE NO.: 15-5434A REPORTED TO: Renar Homes DATE OF TEST: 10/31/2017 al?srmlt No 41707 0297 TEST MDR MOISTURE DRY PERCENT DEPTH NO. House Pad at 9338 Breakers Row NO. CONTENT DENSITY COMPACTION LOCATION % 1 Southeast Corner 1 14.3 111.1 96 0 to -1' 2 Northeast Corner 1 13.3 112.2 97 0 to -1' 3 Northwest Corner 1 12.2 110.8 96 0 to -1' 4 Southwest Corner 1 13.3 111.4 96 0 to -1' 5 Center 1 12.7 110.3 95 0 to -1' * DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT FIELD TEST: r'j ASTM D-2937 rt ASTM D-6938 r- ASTM D-2167 r ASTM D-1556 TECHNICIAN: CF Test depth referenced from: LABORATORY MOISTURE -DENSITY RELATIONSHIP Top of House Pad MDR ASTM MAX. OPTIMUM NO. TEST METHOD DENSITY MOISTURE CONTENT 1 D-1557 115.5 PCF 10 % Remarks: '14i 44 No. 63911 ; T' e t4 STATE OF ®°° d I . E. 63911 AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE C1t7�Q�1 P OF CLIENTS AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RES ENDING OUR WRITTEN APPROVAL.