Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SOUTHERN CITY 1624 Builder Name: Street: 5508 MYRTLE DRIVE Permit Office: FT PIERCE City, State, Zip: FT PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1790.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insui, Exterior R=4.1 1570.00 ft`- b. Frame - Steel, Adjacent R=11.0 220.00 ft= 3. Number of units, if multiple family 1 c. NIA R= ft 4. Number of Bedrooms 4 d. NIA R= ft: 11. Ceiling Types (1624.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1624.00 fN 6. Conditioned floor area above grade 1624 b. NIA R= f? Conditioned floor area below grade (ft2) 0 c. NIA R= ftz 7. Wlndows(183.8 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft= 6 154.8 a. U-Factor. Sgl, U=0.65 183.83 ft' SHGC: SHGC=0.26 b. U-Factor. N/A ita 13. Cooling systems kBtulhr Efficiency SHGC: a. Central Unit 34.6 SEER:15.00 c. U-Factor. NIA ft' SHGC: Area Weighted Average Overhang Depth: 5.232 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 31.0 COP:1.00 S. Skylights Area c. U-Factor(AVG) N/A fY 15. Hot-water systems SHGC(AVG): NIA a. Electric Cap: 40 gallons 9. Floor Types (1624.0 sgfL) Insulation Area EF:0.920 a. Slab -On -Grade Edge Insulation R=0.0 1624.0112 b. Conservation features b. WA R= ft, None c. NIA R= ft' 16. Credits Pstat Glass/Floor Area: 0.113 Total Proposed Modified Loads: 54.76 PASS Total Baseline Loads: 57.69 I hereby certify that the plans and specifications coviged by this calculation are in compl nce with the Florida En gy Code. Review of the plans and specifications covered by this calculation indicates compliance '.1%E S7q�, 1+� FOB, with the Florida Energy Code. PREPARED I 'r~ Before construction is completed DATE: --7 2 this building will be inspected for a compliance with Section 553.908 * ° t hereby certify that this b ding, as designed, is in compliance Florida Statutes. COD with the Florida Ene de. 1'g OWNER/AGENT: ( BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with 11402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 12/17/2021 8:16 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 er ini it et RAftfiADV PLIPe-I[I LCT OFPnOT rumlyl MW0-cvcv u.r.,..r......,...... .. -- - - - PROJECT - -- Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment SOUTHERN CITY 1624 Bedrooms: 4 User Conditioned Area: 1624 Total Stories: 1 1 Worst Case: No Rotate Angle: 0 FT PIERCE Cross Ventilation: Whole House Fan: Detached New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 5508 MYRTLE DRIVE County: St. Lucie City, Stale, Zip: FT PIERCE, FL, CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % 1nt Design Temp Heating Design Daily Temp . Winter Summer Degree Days Moisture. Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1624 16240 SPACES Number Name Area Volume Kitchen Occupants Bedrooms tnfil ID Finished . Cooled Heated 1 Main 1624 16240 Yes 8 4 1 Yes Yes Yes FLOORS Floor Type Space Perimeter R-Value Area Tile Wood Carpet - I Slab -On -Grade Edge Insulatio Main 179 ft 0 1624 ft2 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Red Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1759 ft2 0 ft2 Light N 0.96 No 0.9 No 0 22.62 ATTIC V/ # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1624 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1624 f12 0.11 . Wood 12/17/2021 8:16 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 r-mne Mary nnnn IBIOI 1 r CITInAIIIIADV t-U =f idl ICT 0;=I2A1;T WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo 0 Space 1 N Exterior Concrete Block - Int Insul Main 4,0999 54 10 540.0 ftz 0 0.15 0 2 E Exterior Concrete Block - Int Insul Main 4.0999 34 10 340.0 fN 0 0.15 0 3 S Exterior Concrete Block - Int Insul Main 4.0999 33 10 330.0 fe 0 0.15 0 -4 W Exterior Concrete Block - Int Insul Main 4.0999 36 10 360.0 ft= 0 0.15 0 _ 5 N Garage Frame - Steel Main 11 21 10 210.0 ft' 0.11 0.15 0 -6 W Garage Frame - Steel Main 11 1 10 10.0 ft2 0.11 0.15 0 DOORS # Omt Door Type Space Storms U-Value eightln Area FtW'dth In Ft 1 S Insulated Main None .46 3 6 8 20 ft' 2 N Wood Main None .46 2 8 6 8 17.8 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC' U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 0.65 0.25 N 24.0 ft' 1 ft 6 in 1 ft D.in None None 2 N 1 Metal Single (Tinted) Yes 0.65 0.25 N 12.0 ft2 12 ft 0 in 1 ft 0 in None None 3 N 1 Metal Single (Tinted) Yes 0.65 0.25 N 53.3 ft2 12 ft 0 in 1 ft 0 in None None 4 N 1 Metal Single (Tinted) Yes 0.65 0.25 N 15.0 ft: 1 It 6 in 1 ft 0 in None None 5 E 2 Metal Single (Tinted) Yes 0.65 0.25 N 6.0 ft' 1 It 6 in 1 It 0 in None None 6 S 3 Metal Single (Tinted) Yes 0.65 0.25 N 22.6 ft2 1 ft 6 in 0 It 6 in None None 7 S 3 Metal Single (Tinted) Yes 0.66 0.25 N 39.0 ft2 1 ft 6 in 2 ft 0 in None None 8 S 3 Metal Single (Tinted) Yes 0.65 0.25 N 12.0 W 1 It 6 in 2 ft 0 in None None GARAGE # Floor Area Gelling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 4511111 451 V 64 It loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 f Wholehouse Proposed ACH(50) .000444 1894.7 103,95 195.15 .1381 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heal/ None COPA 31 kStulhr 1 sys#1 12/17/2021 8:16 AM EnergyGauge& USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 RnRnn Rang-9wn IMPUT SHMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency , Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Singl SEER:15 34.6 kBtulhr 1038 cfm 0.75 1 sys#1 HOT WATER SYSTEM # `System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS -- Supply — r/ # Location R-Value Area — Return --- Air Location Area Leakage Type Handler CFM 25 CFM25 TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 164.8ft Attic 61.212 Defauit.Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Coolin [[ ]Jan [[ ]Feb Mar Heating [X] Jan (X] Feb XMar Venting [[ 11 Jan [[ l Feb tt�x]] Mar Ceiling Fans: r , A r r may rl Jun rl Jul rlAug [ ]Apr [ May Jun Jul Aug [[[XXXIII Apr ((( ]]]Ma Jun Jul Aug Sep [ Sep E []]l Sep lx]] ]Oct ]Oct Oct Nov Nav kiNov Dec Dec Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Heating (VVD) AM 66 PM 68 Heating (WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 .78 78 78 78 66 66 68 68 68 68 68 68 66 66 68 68 68 '68 68 68 78 80 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 78 78 78 68 66 68 68 80 178 78 78 68 66 69 66 80 78 78 78 68 66 68 66 ,MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 - Electric Strip Heat 0% 1 -Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibsrs .ft. 0 ft2 0 It 0.3 Main 12/17/2021 8:16 AM EnergyGauge®•USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate: FL VERO BEACH_MUNICIPAL A 5508 MYRTLE DRIVE SOUTHERN CITY 1624 FT PIERCE, FL 12/17/2021 EnergyGaage® / USRCZB v7.0.00 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate: FL VERO_BEACH_MUNICIPAL A 5508 MYRTLE DRIVE SOUTHERN CITY 1624 FT PIERCE, FL 12/17/2021 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 17417 Stuh Sensible Duct Load 7746 Btuh Total Sensible Zone Loads 25164 Btuh Sensible ventilation 0 Btuh Blower 0 Stuh Whole House Total sensible gain 25164 Btuh Totals for Cooling Latent infiltration gain (for 62 gr. humidity difference) 1890 Btuh Latent ventilation gain 0 Btuh Latent duct gain 2706 Btuh Latent occupant gain (8.0 people @ 200 Btuh per person) 1600 Btuh Latent other gain D Btuh Latent total gain 6196 Btuh TOTAL GAIN 31360 Btuh EQUIPMENT 1. Central Unit # 34600 Btuh `Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U-Factor) (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half(%)) (Omt - compass orientation) MANUAL Jo EnergyGauge® I USRCZB v7.0.00 Page 3 Residential System Sizing Calculation Summary Project Title: 5508 MYRTLE DRIVE SOUTHERN CITY 1624 FT PIERCE, FL 12f17f2021 Location for weather data: Fort Pierce, FL - Defaults: Latitude(27.48) Aititude(25 ft.) Temp Range(L) Humidi data: Interior RH 50% Outdoor wet bulb 78F Humiditvdifference 62 r. Winter design temperature(TMY3 99%) 40 F Summer design temperature(TMY3 99%) 91 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 30 F Summer temperature difference 16 F Total heatina load calculation 30438 Btuh Total coolina toad calculation 31360 Btuh Submitted heating capacity % of calc Btuh Submittedcooling capacity % of calc Btuh Total (Electric Strip Heat) 101.8 31000 Sensible (SHR = 0.75) 103.1 25950 Latent 139.6 8650 Total 110.3 34600 WINTER CALCULATIONS Winter Heating Load (for 1624 Load com onent Load Window total 184 sqft 3585 Btuh Wall total 1568 sqft 6836 Btuh Door total 38 sqft 521 Btuh Ceiling total 1624 sqft 1552 Btuh Floor total 1624 -sqft 6337 Btuh Infiltration 60 cfm 1972 Btuh Duct loss 9635 Btuh Subtotal 30438 Btuh Ventilation 0 efm 0 Btuh TOTAL HEAT LOSS 30438 Btuh SUMMER CALCULA Summer Cooling Load for 1624 s ft Load com onent Load Window total 184 sqft 3000 Btuh Wall total 1568 sqft 4523 Btuh Door total 38 sqft 539 Btuh Ceiling total 1624 sqft 2327 Btuh Floor total 0 Btuh Infiltration 45 cirri 789 Btuh Internal gain 6240 Btuh Duct gain 7746 Stuh Sens, Ventilation 0 cfm 0 Stuh Blower Load 0 Btuh Total sensible gain 25164 Btuh Latent gain(ducts) 2706 Btuh Latent gain(infiltration) 1890 Btuh Latent gain(ventilation) 0 Btuh Latent gain(intemal/occupants/other) 1600 Btuh Total latent gain 6196 Btuh TOTAL HEAT GAIN 31360 Btuh wm�stn.sx> 1 Ceilin95l�+%) , Windowsll+�) DUetsl31.7x) Walls(14.4%) Doors(1.7%) --I CeflingsVA%fl Du7ts(33.3%) Windows(9.65b) r z Int.Galn(19.9'K) EnergyGaugeS s ng PREPARED BY:- 1i -4� DATE: EnergyGauge® / USRCZB v7.0.00 System Sizing Calculations - Summer Residential Load - Room by Room Component Details Project Title: 5508 MYRTLE DRIVE SOUTHERN CITY 1624 FT PIERCE, FL 12l17l2D21 Reference City: Fort Pierce, FL Temperature Difference: 16.OF(TMY3 99%) Humidity difference: 62gr. Component Loads for Room #1: Main Type" Overhang Window Area(sgft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross Shaded Unshadec Shaded Unshaded 1 1 NFRC 0.25, 0.65 No No N 1.5ft Loft 24.0 0.0 24.0 16 16 378 Btuh 2 1 NFRC 0.25, 0.65 No No N 12.Of 1.0ft 12.0 0.0 12.0 16 16 189 Btuh 3 1 NFRC 0.25, 0.65 No No N 12.Of 1.0ft 53.3 0.0 53.3 16 16 840 Btuh 4 1 NFRC 0.25, 0.65 No No N 1.5ft 1.0ft 15.0 0.0 15.0 16 16 236 Btuh 5 1 NFRC 0.25, 0.65 No No E 1.5ft 1.0ft 6.0 0.5 5.5 16 35 199 Btuh 6 1 NFRC 0.25, 0.65 No No S 1.5ft 0.5ft 22.5 22.5 0.0 16 17 354 Btuh 7 1 NFRC 0.25, 0.65 No No S 1.5ft 2.Oft 39.0 39.0 0.0 16 17 614 Btuh 8 1 NFRC 0.25, 0.65 No No S 1.5ft 2.Oft 12.0 12.0 0.0 16 17 189 Btuh Window Total 1 184 (s ft) 3000 Btuh Walls Type U Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Concrete Blk,Hollow - Ext 0.15 4.110.0 435.7 3.0 1320 Btuh 2 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 334.0 3.0 1012 Btuh 3 Concrete Blk,Hollow- Ext 0.15 4.110.0 236.5 3.0 716 Btuh 4 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 360.0 3.0 1091 Btuh 5 Frame - Steel - Adj 0.12 11.0/0.0 192.2 1.9 365 Btuh 5 Frame - Steel - Adj 0.12 11.0/0.0 10.0 1.9 19 Btuh Wall Total 1568 s ft 4523 Btuh Doors Type Area (sqft) HTM Load 1 Insulated - Exterior 20.0 14.3 285 Btuh 2 Wood - Garage 17.8 14.3 254 Btuh Door Total 38 s ft) 539 Btuh Ceilings Type/Color/Surface U-Value R Value Area(sgft) HTM Load 1 Vented Attic/Light/Shingle 0.032 30.0/0.0 1624.0 1.43 2327 Btuh Ceiling Total 1624 s ft 2327 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 1624 (ft-perimeter) 0.0 0 Stuh Floor Total 1624.0 sgft) 0 Btuh Zone Envelope Subtotal: 10388 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.17 16240 1.00, 44.9 Load 789 Btuh Internal gain Occupants Btuh/occupant Appliance 8 X 230 + 4400 Load 6240 Btuh Sensible Envelope Load: 17417 Btuh Duct load Average, sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.445) 7746 Btuh Sensible Zone Load 26164 Btuh EnergyGauge®1 USRCZB v7.0.00 Page 1 �..®i CERTIFlED� www,ahrldireciary,orgCerfificate of Product Ratincis AHRI Certified Reference Number: 201383914 Date :12-17-2021 Model Status: Active Old AHRI Reference Number: 8242064 AHRI Type: RCU-A-CB (Split System: Air -Cooled Condensing Unit, Coll with Blower) Series : GSX14 Outdoor Unit Brand Name : GOODMAN Outdoor Unit Model Number (Condenser or Single Package) : GSX140361 K` Indoor Unit Model Number (Evaporator and/or Air Handler) : ASPT47D14A' Region : Southeast and North (AL, AR,,DC, DE, FL, GA, HI, KY, LA, MD, MS, NC, OK, SC, TN, TX; VA, AK, CO, CT, ID, IL, IA, IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SD, UT, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can.only be Installed in region(s) for <' 'which they meet the regional efficiency r"ulremenL _.._ The manufacturer of this GOODMAN product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 2101240 with AddendUm';1, Perfor-man6e Rating of Unitary Air;Conditioning, 8, Air -Source -Heat Pump Equipment and subjeci to rating accuracy by AHRI,§ponsared; independent, th)rd' partytesting Cooling Capacity (A2) Single or High Stage (95F); btuh 346o0 SEER :16.00 , EER (A2)'-:Single or High Stage (95F)- : 12.50 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not being produced "Production Stopped' Model Status are those that an AHRI Certification Program Participant Is no longer producing BUT is still selling or offering for sale. Ratings that are accomoanled by WAS indicate an involuntary re -rate The new oublished rating is shown along with the omious tie WAS) rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the., unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.abridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, In any form ormatineror by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The Information for the model cited on this certificate Can be verified at www.ahridireetory.Org, click on `Verify Certificate' link we make life better' and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certificate No., which Is listed at bottom right ©2021 Air-Condltloning, Heating, and Refrigeration Institute CERTIFICATE NO:: tg2e42tss33oa3oso3