HomeMy WebLinkAboutAPPROVED 33 SOVREIGN WAY, HUTCHINSON ISLAND (SOLUTION) - Copy (2) Border (1) (1)FOUND
S NAIL EP SPECIFIC PURPOSE SURVEY LEGAL DESCRIPTION:
LOT A, BLOCK 8, QUEENS COVE —UNIT 1, ACCORDING TO THE MAP OR PLAT
23 SO THEREOF, AS RECORDED IN PLAT BOOK 11, PAGES 12B AND 12C, OF THE PUBLIC
8S c� ' • (-Op (Q4e hsC j�,� RECORDS OF ST. LUCIE COUNTY, FLORIDA.
e4s 81S\W R�9ht�o f` lw by 0 LOT AREA: 11,556 Sq. Ft.; 0.27 Acres±
oEP of eeor�ng� 3' W o�� D 202 P t) STREET ADDRESS: 33 SOVREIGN WAY, HUTCHINSON ISLAND, FLORIDA 34949.
,o NAIL
e 4ve�ent SURVEYORS' NOTES:
10,
1. BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF SOVREIGN WAY
AS PLATTED AND BEARS N 71`58'15" W.
��•c�s o% /� 312» 8 2. THE EXPECTED USE OF THE SURVEY AND MAP IS FOR CONSTRUCTION
w 819 72, 6PERMITTING.
/ S6•�3, 3. ALL DISTANCES AND BEARINGS ARE AS FIELD MEASURED AND ARE COINCIDENT
/ WITH "PLAT" AND DESCRIPTION DATA UNLESS OTHERWISE NOTED.
/ O
FOUND 1/2" � Q� � 4. THIS DRAWING IS NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL
IRON ROD ��•2', OF A FLORIDA LICENSED SURVEYOR & MAPPER.
�; 1.2
I LWig) 6 5. THIS SURVEY IS BASED UPON A DESCRIPTION FURNISHED BY THE CLIENT, THERE
64 0, HAS BEEN NO EXTENSIVE SEARCH OF THE PUBLIC RECORDS BY THIS OFFICE.
49.72 , 6. NO ATTEMPT HAS BEEN MADE TO LOCATE UNDERGROUND IMPROVEMENTS.
1
24 FLOOD ZONE "X" - 7. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE
SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE
N (0.2 PCT ANNUAL \ SIGNING PARTY OR PARTIES.
LOT A CHANCE FLOOD HAZARD 8. PROPERTY HEREON LOCATED IN FLOOD ZONE "AE" (EL 5') PER F.I.R.M.
4 Block 8 IN COASTAL ZONE) 121 1 1 C0089K, DATED 2-19-20.
■ to] 914N
CL = CENTERLINE
EP = EDGE OF PAVEMENT
D = DELTA ANGLE
L = ARC LENGTH
R = RADIUS
SPECIFIC
SURVEY
Permit#:
LOT B
Block 8
(IMPROVED)
PURPOS
.j
D ZO
EXISTING
4" FRAME WALL
TO BE REPLACED
WITH 8" BLOCK 11.0 a
FOUND 1/2"
IRON RO O_
At
TFLOOD ZONE 'Y'
o (MINIMAL FLOOD
N HAZARD)
EXISTING ONE—STORY
RESIDENCE
FFE=5.13
EXISTING
568' COVERED
TILED PATI
�6.3 cn EXISTING
Ep�srrNc POOL
0C� DECK
EXISTING
COMPOSITI
DOCK &
WALKWAY
/ EXISTING`
4" FRAME WA
0 BE REPLAC
— EXISTING ITH 8" BLOC
BLOCK WALL 1
�40'p)�, � FO
N/ IR(
$
0• 68' (�
Platted Water EXISTING
Channe
ALUMINUM —
CAPPED
SEAWALL
» A F>>�
U
a �O
��ryto
4v
9. THE TRAVERSE CLOSURE FOR THE SUBJECT PROPERTY EXCEEDS 1:10,000'.
10. PARCEL IDENTIFICATION NUMBER: 1414-701-0064-000-2.
11. ALL MEASUREMENTS ARE IN ACCORDANCE WITH THE UNITED STATES STANDARD
IN FEET.
12. THE SPECIFIC PURPOSE OF THIS SURVEY IS TO DEPICT THE PROPOSED
IMPROVEMENTS TO BE CONSTRUCTED ON THE SUBJECT PROPERTY. EXISTING
IMPROVEMENTS ON THE PROPERTY NOT DEPICTED HEREIN ARE NOT PERTINENT TO
THE SPECIFIC PURPOSE OF THIS SURVEY.
CERTIFIED TO: DAVID C. SMITH
CERTIFICATION:
I HEREBY CERTIFY THAT THE SURVEY PRESENTED HEREON WAS PERFORMED
UNDER MY SUPERVISION AND IT COMPLIES WITH THE STANDARDS OF PRACTICE
AS SET FORTH BY THE FLORIDA BOARD OF SURVEYORS & MAPPERS IN CHAPTER
5J-17.050 - 17.052 OF THE FLORIDA ADMINISTRATIVE CODE, PURSUANT TO
SECTION 472.027, FLORIDA STATUTES, AND FURTHER THAT THERE ARE NO
VISIBLE, ABOVE GROUND ENCROACHMENTS UNLESS SHOWN OR NOTED.
Date of last field work: 01-12-22 STEVEN D. MARSHALL LS6376