Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ` Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SMITH RESIDENCE Builder Name: Street: 4800 INDRIO RD. Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. Jurisdiction: Design Location: FL, Fort Pierce County. St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(2637.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, ExterioiR=4.1 2417.00 ft2 b. Frame - Wood, Adjacent R=11.0 220.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types(2463.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2463.00 ft2 6. Conditioned floor area above grade (ftz) 2462 b. N/A R= ft2 Conditioned floor area below grade (ftz) 0 c. NIA R= ft2 7. Windows(400.5 sqft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=1.05 400.51 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 250 SHGC: SHGC=0.25 b. b. U-Factor. N/A ft2 C. SHGC: 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 47.0 SEER:14.50 SHGC: Area Weighted Average Overhang Depth: 8.830 ft Area Weighted Average SHGC: 0.250 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 45.0 HSPF:8.50 U-Factor:(AVG) NIA N/A ft2 SHGC(AVG): N/A 15. •Hot Water Systems 9. Floor Types Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R= 0.0 2462.00 ft2 EF: 0.950 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 16. Credits None Glass/Floor Area: 0.163 Total Proposed Modified Loads: 74.65 PASS Total Baseline Loads: 78.48 I hereby certify that the plans and specifications covered by Review of the plans and CHEST A?F this calculation ar compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance with the Florida Energy Code. pF S' ti O PREPARED BY: Before construction is completed tix' �:• °-"- (( DATE: �� l"�!�'C�G this building will be inspected for compliance with Section 553.908 Florida Statutes. a O t I hereby certify that this building, as designed, is in compliance WE with the Florida Energy Code. OWNERIAGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSURESNET/ICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). 6/21/2021 8:03:03 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: SMITH RESIDENCE Address type: Street Address Building Type: User Bedrooms: 3 Lot #: -- Owner: Conditioned Area: 2462 Block/SubDivision: — Total Stories: 1 PlatBook: — Builder Name: Worst Case: No Street: 4800 INDRIO RD. -Permit Office: Rotate Angle: 0 County: St. Lucie Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban Year Construct: Shielding: Suburban Comment: "CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.50/6 Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO—BEACH—MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2462 '25156 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 BATH 3 47 470 No 0 Yes Yes Yes _ BEDROOM 4 139 1390 No 1 1 Yes Yes Yes —2 BEDROOM 3 156 1560 No 1 1 Yes Yes Yes —3 BATH 2 48 480 No 0 Yes Yes Yes —4 5 BEDROOM 2 148 1480 No 1 Yes Yes Yes _ 6 ;LAUNDRY 117 1170 No 0 Yes Yes Yes- _ PANTRY 14 140 No 0 No Yes Yes -7 8 FAMILY ROOM 255 2550 No 0 Yes Yes Yes _ 9 HALL 34 340 No 0 Yes Yes Yes _ 10 KITCHEN 271 2710 Yes 0 Yes Yes Yes _ 11 DINING/LIVING 536 5896 No 4 Yes Yes Yes _ 12 MASTER BEDROOM 282 2820 No 2 1 Yes Yes Yes _ 13 9WIC 2 30 300 No 0 No Yes Yes _ 14 WIC 36 360 No 0 Yes Yes Yes _ _ 15 TLT 18 180 No 0 Yes Yes Yes 16 M BATH 155 1550 No 0. Yes Yes Yes _ 17 DEN 176 1760 No 0 Yes Yes Yes 6/21/2021 8:03:03 AM EnergyGauge® USA 7A:00 FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS (Total Exposed Area = 2462 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Ins BATH 3 14 0 48 ft 0.473 -- 0.00 1.00 0.00 _ Slab -On -Grade Edge Ins BEDROOM 4 11 0 139 ft 0.473 -- 0.00 1.00 0.00 -2 3 Slab -On -Grade Edge Ins BEDROOM 3 12 0 157 ft 0.473 - 0.00 1.00 0.00 T 4 Slab -On -Grade Edge Ins BATH 2 6 0 48 ft 0.473 - 0.00 1.00 0.00 5 Slab -On -Grade Edge Ins BEDROOM 2 25 0 147 ft 0.473 -- 0.00 1.00 0.00 _ 6 Slab -On -Grade Edge Ins ;LAUNDRY 15 0 117 ft 0.473 - 0.00 1.00 0.00 _ 7 Slab -On -Grade Edge Ins PANTRY 1 0 14 ft 0.473 -- 0.00 1.00 0.00 _ 8 Slab -On -Grade Edge Ins FAMILY ROOM 32 0 255 ft 0.473 - 0.00 1.00 0.00 _ 9 Slab -On -Grade Edge Ins HALL 5 0 34 ft 0.473 - 0.00 1.00 0.00 _ _ 10 Slab -On -Grade Edge Ins KITCHEN 4 0 271 ft OA73 - 0.00 1.00 0.00 _ 11 Slab -On -Grade Edge Ins DINING/LIVING 42 0 536 ft 0.473 - 0.00 1.00 0.00 _ 12 Slab -On -Grade Edge Ins MASTER BEDROOM 38A 0 282 ft 0.473 - 0.00 1.00 0.00 _ 13 Slab -On -Grade Edge Ins GWIC 2 1 0 30 ft 0.473 - 0.00 1.00 0.00 _ 14 Slab -On -Grade Edge Ins WIC 6 0 36 ft 0.473 - 0.00 1.00 0.00 _ 15 Slab -On -Grade Edge Ins TLT 3 0 18 ft 0.473 - 0.00 1.00 0.00 _ 16 Slab -On -Grade Edge Ins M BATH 11.9 0 154.5 ft 0.473 - 0.00 1.00 0.00 17 Slab -On -Grade Edge Ins DEN 34.9 0 175.5 ft 0.473 -- 0.00 1.00 0.00 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch J# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2595 ft2 0 ftZ Medium N 0.6 No 0.9 No 0 18.43 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2462 ftZ N N CEILING (Total Exposed Area = 2463 sq.ft.)- # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type- 1 UnderAttic(Vented) BATH 3 30.0 Blown 48.0ft2 0.053 0.10 Wood _ Under Attic(Vented) BEDROOM 4 30.0 Blown 139.0ft2 0.053 0.10 Wood -2 Under Attic(Vented) BEDROOM 3 30.0 Blown 156.0ft2 0.053 0.10 Wood -3 Under Attic(Vented) BATH 2 30.0 Blown 48.0ft2 0.053 0.10 Wood -4 Under Attic(Vented) BEDROOM 30.0 Blown 148.0ft2 0.053 0.10 Wood _5 UnderAttic(Vented) ;LAUNDRY 30.0 Blown 117.Oft2 0.053 0.10 Wood _6 Under Attic(Vented) PANTRY 30.0 Blown 14.0ft2 0.053 0.10 Wood _7 8 Under Attic(Vented) FAMILY ROOM 30.0 Blown 255.0ft2 0.053 0.10 Wood _ 9 Under Attic(Vented) HALL 30.0 Blown 34.OW 0.053 0.10 Wood _ _ 10 Under Attic(Vented) KITCHEN 30.0 Blown 271.0f12 0.053 0.10 Wood 11 Under Attic(Vented) DINING/LNING 30.0 Blown 536.OftZ 0.053 0.10 Wood _ _ 12 Under Attic(Vented) MASTER BEDROOM 30.0 Blown 282.02 0.053 0.10 Wood 13 Under Attic(Vented) 11WIC2 30.0 Blown 30.0ft2 0.053 0.10 ' Wood _14 Under Attic(Vented) WIC 30.0 Blown 36.0ft2 0.053 0.10 Wood -„ 15 Under Attic(Vented) TILT 30.0 Blown 18.0ft2 0.053 0.10 Wood _ 16 Under Attic(Vented) M BATH 30.0 Blown 155.0ft2 0.053 0.10 Wood 17 Under Attic(Vented) DEN 30.0 Blown 176.0ft2 0.053 0.10 Wood 6121/2021 8:03,03 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS (Total Exposed Area = 2637 sq.ft.) Cavity Width Height Area U- Sheath Frm. Solar Below VAdjacent # Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 N Exterior Cone. Blk - Ext Ins BATH 3 4.1 8.0 0 10.0 0 80.0 0.131 0 0 0.60 0 % -2 W Exterior Cone. Blk - Ext Ins BATH 3 4.1 6.0 0 10.0 0 60.0 0.131 0 0 0.60 0 % _ 3 W Exterior Cone. Blk - Ext Ins BEDROOM 4 4.1 11.0 0 10.0 0 110.0 0.131 0 0 0.60 0 % W Exterior Cone. Blk- Ext Ins BEDROOM 3 4.1 12.0 0 10.0 0 120.0 0.131 0 0 0.60 0 % _4 5 W Exterior Cone. Blk - Ext Ins BATH 2 4.1 6.0 0 10.0 0 60.0 0.131 0. 0 0.60 0 % _ 6 W Exterior Cone. Blk - Ext Ins BEDROOM 2 4.1 11.0 0 10.0 0 110.0 0.131 0 0 0.60 0 % _ 7 E Exterior Cone. Bilk - Ext Ins ;LAUNDRY 4.1 6.0 0 10.0 0 60.0 0.131 0 0 0.60 0 % _ 8 N Exterior Cone. Bilk - Ext Ins FAMILY ROOM 4.1 15.0 0 10.0 0 150.0 0.131 0 0 0.60 0 % _ E Exterior Cone. Blk - Ext Ins FAMILY ROOM 4.1 17.0 0 10.0 0 170.0 0.131 0 0 0.60 0 % -9 10 N Exterior Cone. Blk - Ext Ins HALL 4.1 5.0 0 10.0 0 50.0 0.131 0 0 0.60 0 % _ 11 N Exterior Cone. Bik - Ext Ins KITCHEN 4.1 4.0 0 10.0 0 40.0 0.131 0 0 0.60 0 % _ 12 N Exterior Cone. Blk - Ext Ins DININGILIVING 4.1 14.0 0 11.0 0 154.0 0.131 0 0 0.60 0 % _ 13 E Exterior Cone. Blk - Ext Ins DINING/LIVING 4.1 1.0 0 11.0 0 11.0 0.131 0 0 0.60 0 % _ _ 14 S Exterior Cone. Bilk - Ext Ins DINING/LIVING 4.1 25.0 0 11.0 0 275.0 0.131 0 0 0.60 0 % 15 W Exterior Cone. Blk - Ext Ins DINING/LIVING 4A 2.0 0 11.0 0 22.0 0.131 0 0 0.60 0 % _ 16 N Exterior Cone. Blk - Ext Ins MASTER BEDROOM 4.1 9.0 0 10.0 0 90.0 0.131 0 0 0.60 0 % _ 17 NE Exterior Cone. Bilk - Ext Ins MASTER BEDROOM 4.1 4.0 3 10.0 0 42.5 0.131 0 0 0.60 0 % _ 18 E Exterior Cone. Blk - Ext Ins MASTER BEDROOM 4.1 13.0 0 10.0 0 130.0 0.131 0 0 0.60 0 % _ 19 W Exterior Cone. Blk - Ext Ins MASTER BEDROOM 4.1 8.0 0 10.0 0 80.0 0.131 0 0 0.60 0 % _ 20 NW Exterior Cone. Blk - Ext Ins MASTER BEDROOM 4.1 4.0 3 10.0 0 42.5 0.131 0 0 0.60 0 % _ 21 E Exterior Cone. Blk - Ext Ins WIC 4.1 6.0 0 10.0 0 60.0 0.131 0 0 0.60 0 % _ 22 E Exterior Cone. Blk - Ext Ins TLT 4.1 3.0 0 10.0 0 30.0 0.131 0 0 0.60 0 % _ 23 E Exterior Cone. Blk - Ext Ins M BATH 4.1 12.0 0 10.0 0 120.0 0.131 0 0 0.60 0 % _ 24 E Exterior Cone. Blk - Ext Ins DEN 4.1 10.0 0 10.0 0 100.0 0.131 0 0 0.60 0 % _ 25 S Exterior Cone. Bilk - Ext Ins DEN 4.1 15.0 0 10.0 0 150.0 0.131 0 0 0.60 0 % _ 26 W Exterior Cone. Blk - Ext Ins DEN 4.1 10.0 0 10.0 0 100.0 0.131 0 0 0.60 0 % _ 27 N Garage Frame - Wood DEN 11.0 22.0 0 10.0 0 220.0 0.092 0.23 0.60 0 % DOORS (Total Exposed Area = 0 sq.ft.) Width Height ✓# Omt Adjacent To Door Type Space Storms U Value Ft In Ft In Area 1 N Exterior Wood BATH 3 None 0.20 0.10 0 0.10 0 0.1ft2 WINDOWS (Total Exposed Area = 401 sq.ft.) Wall ---Overhang-- ✓# Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening _ 1 N 1 Metal Low-E Single Yes 1.05 . 0.25 Y N 6.0ft2 2.0 ft 0 in 1.0 ft 5 in None None -2 W 3 Metal Low-E Single Yes 1.05 0.25 Y N 15.0ft2 2.0 ft 0 in 1.0 ft 5 in None None W 4 Metal Low-E Single Yes 1.05 0.25 Y N 15.0ft2 2.0 ft 0 in 1.0 ft 5 in None None -3 -4 W 5 Metal Low-E Single Yes 1.05 0.25 Y N 6.0ft2 2.0 ft 0 in 1.0 ft 5 in None None W 6 Metal Low-E Single Yes 1.05 0.25 Y N 15.0ftl 2.0 ft 0 in 1.0 ft 5 in None None -5 N 8 Metal Low-E Single Yes 1.05 0.25 Y N 20.0ft2 2.0 It 0 in 1.0 ft 5 in None None -6 _ 7 E 9 Metal Low-E Single Yes 1.05 0.25 Y N 41.0ft2 20.0 ft 0 in 1.0 ft 5 in None None 8 E 9 Metal Low-E Single Yes 1.05 0.25 Y N 15.0ft2 10.0 ft 0 in 1.0 ft 5 in None None _ N 10 Metal Low-E Single Yes 1.05 0.25 Y N 19.4ft2 2.0 ft 0 in 1.0 ft 5 in None None -9 _„ 10N 11 Metal Low-E Single Yes 1.05 0.25 Y N 15.0ft2 10.0 ft 0 in 1.0 ft 5 in None None 11 N 12 Metal Low-E Single Yes 1.05 0.25 Y N 61.5ft2 20.0 ft 0 in 1.0 ft 5 in None None _ 12S 14 Metal Low-E Single Yes 1.05 0.25 Y N 38.2ft2 6.0 ft 0 in 1.0 ft 5 in None None _ 13S 14 Metal Low-E Single Yes 1.05 0.25 Y N 12.5ft2 6.0 ft 0 in 1.0 ft 5 in None None _ 14S 14 Metal Low-E Single Yes 1.05 0.25 Y N 30.0112 6.0 ft 0 in 1.0 ft 5 in None None _ 15N 16 Metal Low-E Single Yes 1.05 0.25 Y N 41.0ft2 10.0 ft 0 in 1.0 ft 5 in None None _ 16NE 17 Metal Low-E Single Yes 1.05 0.25 Y N 10.0ft2 2.0 ft 0 in 1.0 ft 5 in None None 17NW 20 Metal Low-E Single Yes 1.05 0.25 Y N 10.Oft2 2.0 ft 0 in 1.0 ft 5 in None None 18E 23 Metal Low-E Single Yes 1.05 0.25 Y N 15.0ft2 2.0 ft 0 in 1.0 ft 5 in None None 6/21/2021 8:03:04 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS(Continued) 1-19S 25 Metal Low-E Single Yes 1.05 0.25 Y N 15.02 2.0 ft 0 in 1.0 ft 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00032 2096 115.01 215.92 0.0995 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 471 ft2 471 lit' 64 ft loft 1 MASS # Mass Type Area Thickness Furniture Fraction Space _ 1 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 BATH 3 -2 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 BEDROOM 4 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 BEDROOM 3 -3 _ 4 Default(8 Ibslsq.ft:) 0 ft2 O ft 0.30 BATH 2 _ 5 Default(8 Ibs/sq.ft.) 0 ft2 oft. 0.30 BEDROOM 2 6 Default(B Ibs/sq.ft.) 0 ft2 0 ft 0.30 ;LAUNDRY _ _ 7 Default(8 Ibstsq.ft.) 0 ft2 0 ft 0.30 PANTRY _ 8 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 FAMILY ROOM _ 9 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 HALL _ 10 Default(8 Ibs/sq.fL) 0 ft2 0 ft 0.30 KITCHEN _ 11 Default(8 Ibs/sq.ft) 0 ft2 0 ft 0.30 DININGILIVING _ 12 Default(8 Ibs/sq.f .) 0 ft2 0 ft 0.30 MASTER BEDROOM _ 13 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 WVIC 2 _ 14 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 WIC _ 15 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 TLT _ 16 Default(8 lbs/sq.ft.) 0 ft2 0 ft 0.30 M BATH 17 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 DEN HEATING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity -Geothermal HeatPump---- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump None/Single HSPF: 8.50 45.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtulhr cfm 1 Central Unit Split/Single SEER:14.5 47.0 1410 0.70 sys#1 1 6/21/2021 8:03:04 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric None Garage 0.95 (0.93) 50.00 gal 61 gal 120 deg Standard None 109 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS --Supply Return- Air CFM 25 CFM 25 HVAC # JDuct # Location R-Value Area Location R-Value Area Leakage Type . Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0 250 ft2 Attic 6.0 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [] Jan [] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [.] Nov [ j Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ j Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ j Jun [ ] Jul [ ] Aug [I Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (IND) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6/21/2021 8:03:04 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA" Project Name: SMITH RESIDENCE Builder Name: Street: 48001NDRIO RD. Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: iU Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class 1 vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall • on exterior wall and tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box The air barrier shall be installed behind electrical or on exterior walls communication boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between firesprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/21/2021 8:03:20 AM EnergyGaugeO USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1