HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
` Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: SMITH RESIDENCE
Builder Name:
Street: 4800 INDRIO RD.
Permit Office:
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner.
Jurisdiction:
Design Location: FL, Fort Pierce
County. St. Lucie(Florida Climate Zone 2)
1. New construction or existing New (From Plans)
10. Wall Types(2637.0 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Ext Insul, ExterioiR=4.1 2417.00 ft2
b. Frame - Wood, Adjacent
R=11.0 220.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types(2463.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2463.00 ft2
6. Conditioned floor area above grade (ftz)
2462
b. N/A
R= ft2
Conditioned floor area below grade (ftz)
0
c. NIA
R= ft2
7. Windows(400.5 sqft.) Description
Area
12. Ducts, location & insulation level R ft2
a. U-Factor: Sgl, U=1.05
400.51 ft2
a. a. Sup: Attic, Ret: Attic, AH:
Attic 6 250
SHGC: SHGC=0.25
b.
b. U-Factor. N/A
ft2
C.
SHGC:
13. Cooling Systems
kBtu/hr Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
47.0 SEER:14.50
SHGC:
Area Weighted Average Overhang Depth:
8.830 ft
Area Weighted Average SHGC:
0.250
14. Heating Systems
kBtu/hr Efficiency
8. Skylights Description
Area
a. Electric Heat Pump
45.0 HSPF:8.50
U-Factor:(AVG) NIA
N/A ft2
SHGC(AVG): N/A
15. •Hot Water Systems
9. Floor Types Insulation
Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R= 0.0
2462.00 ft2
EF: 0.950
b. N/A R=
ft2
b. Conservation features
c. N/A R=
ft2
None
16. Credits
None
Glass/Floor Area: 0.163 Total Proposed Modified Loads: 74.65
PASS
Total Baseline
Loads: 78.48
I hereby certify that the plans and specifications covered by
Review of the plans and
CHEST
A?F
this calculation ar compliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
pF
S'
ti O
PREPARED BY:
Before construction is completed
tix' �:• °-"-
((
DATE: �� l"�!�'C�G
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
a
O t
I hereby certify that this building, as designed, is in compliance
WE
with the Florida Energy Code.
OWNERIAGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSURESNET/ICC 380, is not greater than 0.000 Qn for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
6/21/2021 8:03:03 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
SMITH RESIDENCE
Address type:
Street Address
Building Type:
User
Bedrooms: 3
Lot #:
--
Owner:
Conditioned Area: 2462
Block/SubDivision: —
Total Stories: 1
PlatBook:
—
Builder Name:
Worst Case: No
Street:
4800 INDRIO RD.
-Permit Office:
Rotate Angle: 0
County:
St. Lucie
Jurisdiction:
Cross Ventilation: No
City, State, Zip:
FT. PIERCE,
Family Type:
Detached
Whole House Fan: No
FL,
New/Existing:
New (From Plans)
Terrain: Suburban
Year Construct:
Shielding: Suburban
Comment:
"CLIMATE
Design
Design Temp
Int Design Temp
Heating
Design
Daily temp
Location
Tmy Site
97.5% 2.50/6
Winter Summer
Degree Days
Moisture
Range
FL, Fort Pierce
FL VERO—BEACH—MUNICIPA 39 90
70 75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2462
'25156
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
Finished
Cooled
Heated
1
BATH 3
47
470 No 0
Yes
Yes
Yes
_
BEDROOM 4
139
1390 No 1
1
Yes
Yes
Yes
—2
BEDROOM 3
156
1560 No 1
1
Yes
Yes
Yes
—3
BATH 2
48
480 No 0
Yes
Yes
Yes
—4
5
BEDROOM 2
148
1480 No 1
Yes
Yes
Yes
_
6
;LAUNDRY
117
1170 No 0
Yes
Yes
Yes-
_
PANTRY
14
140 No 0
No
Yes
Yes
-7
8
FAMILY ROOM
255
2550 No 0
Yes
Yes
Yes
_
9
HALL
34
340 No 0
Yes
Yes
Yes
_
10
KITCHEN
271
2710 Yes 0
Yes
Yes
Yes
_
11
DINING/LIVING
536
5896 No 4
Yes
Yes
Yes
_
12 MASTER BEDROOM
282
2820 No 2
1
Yes
Yes
Yes
_
13
9WIC 2
30
300 No 0
No
Yes
Yes
_
14
WIC
36
360 No 0
Yes
Yes
Yes
_
_ 15
TLT
18
180 No 0
Yes
Yes
Yes
16
M BATH
155
1550 No 0.
Yes
Yes
Yes
_
17
DEN
176
1760 No 0
Yes
Yes
Yes
6/21/2021 8:03:03 AM EnergyGauge® USA 7A:00 FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2
FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
(Total Exposed Area = 2462 sq.ft.)
# Floor Type
Space Exposed Perim Perimeter R-Value
Area U-Factor Joist R-Value
Tile
Wood Carpet
1 Slab -On -Grade Edge Ins
BATH 3 14
0
48 ft
0.473
--
0.00
1.00 0.00
_
Slab -On -Grade Edge Ins
BEDROOM 4 11
0
139 ft
0.473
--
0.00
1.00 0.00
-2
3 Slab -On -Grade Edge Ins
BEDROOM 3 12
0
157 ft
0.473
-
0.00
1.00 0.00
T 4 Slab -On -Grade Edge Ins
BATH 2 6
0
48 ft
0.473
-
0.00
1.00 0.00
5 Slab -On -Grade Edge Ins
BEDROOM 2 25
0
147 ft
0.473
--
0.00
1.00 0.00
_
6 Slab -On -Grade Edge Ins
;LAUNDRY 15
0
117 ft
0.473
-
0.00
1.00 0.00
_
7 Slab -On -Grade Edge Ins
PANTRY 1
0
14 ft
0.473
--
0.00
1.00 0.00
_
8 Slab -On -Grade Edge Ins
FAMILY ROOM 32
0
255 ft
0.473
-
0.00
1.00 0.00
_
9 Slab -On -Grade Edge Ins
HALL 5
0
34 ft
0.473
-
0.00
1.00 0.00
_
_ 10 Slab -On -Grade Edge Ins
KITCHEN 4
0
271 ft
OA73
-
0.00
1.00 0.00
_ 11 Slab -On -Grade Edge Ins
DINING/LIVING 42
0
536 ft
0.473
-
0.00
1.00 0.00
_ 12 Slab -On -Grade Edge Ins
MASTER BEDROOM 38A
0
282 ft
0.473
-
0.00
1.00 0.00
_ 13 Slab -On -Grade Edge Ins
GWIC 2 1
0
30 ft
0.473
-
0.00
1.00 0.00
_ 14 Slab -On -Grade Edge Ins
WIC 6
0
36 ft
0.473
-
0.00
1.00 0.00
_ 15 Slab -On -Grade Edge Ins
TLT 3
0
18 ft
0.473
-
0.00
1.00 0.00
_ 16 Slab -On -Grade Edge Ins
M BATH 11.9
0
154.5 ft
0.473
-
0.00
1.00 0.00
17 Slab -On -Grade Edge Ins
DEN 34.9
0
175.5 ft
0.473
--
0.00
1.00 0.00
ROOF
Roof Gable
Roof
Rad Solar SA
Emitt
Emitt
Deck Pitch
J# Type
Materials Area Area
Color
Barr Absor. Tested
Tested
Insul. (deg)
1 Hip
Composition shingles 2595 ft2 0 ftZ
Medium
N
0.6 No
0.9
No
0 18.43
ATTIC
# Type
Ventilation
Vent Ratio (1 in) Area
RBS
IRCC
1 Full attic
Vented
150
2462 ftZ
N
N
CEILING
(Total Exposed Area = 2463 sq.ft.)-
# Ceiling Type
Space
R-Value
Ins. Type
Area
U-Factor
Framing Frac.
Truss Type-
1 UnderAttic(Vented)
BATH 3
30.0
Blown
48.0ft2
0.053
0.10
Wood
_
Under Attic(Vented)
BEDROOM 4
30.0
Blown
139.0ft2
0.053
0.10
Wood
-2
Under Attic(Vented)
BEDROOM 3
30.0
Blown
156.0ft2
0.053
0.10
Wood
-3
Under Attic(Vented)
BATH 2
30.0
Blown
48.0ft2
0.053
0.10
Wood
-4
Under Attic(Vented)
BEDROOM
30.0
Blown
148.0ft2
0.053
0.10
Wood
_5
UnderAttic(Vented)
;LAUNDRY
30.0
Blown
117.Oft2
0.053
0.10
Wood
_6
Under Attic(Vented)
PANTRY
30.0
Blown
14.0ft2
0.053
0.10
Wood
_7
8 Under Attic(Vented)
FAMILY ROOM
30.0
Blown
255.0ft2
0.053
0.10
Wood
_
9 Under Attic(Vented)
HALL
30.0
Blown
34.OW
0.053
0.10
Wood
_
_ 10 Under Attic(Vented)
KITCHEN
30.0
Blown
271.0f12
0.053
0.10
Wood
11 Under Attic(Vented)
DINING/LNING
30.0
Blown
536.OftZ
0.053
0.10
Wood
_
_ 12 Under Attic(Vented)
MASTER BEDROOM 30.0
Blown
282.02
0.053
0.10
Wood
13 Under Attic(Vented)
11WIC2
30.0
Blown
30.0ft2
0.053
0.10
'
Wood
_14 Under Attic(Vented)
WIC
30.0
Blown
36.0ft2
0.053
0.10
Wood
-„ 15 Under Attic(Vented)
TILT
30.0
Blown
18.0ft2
0.053
0.10
Wood
_ 16 Under Attic(Vented)
M BATH
30.0
Blown
155.0ft2
0.053
0.10
Wood
17 Under Attic(Vented)
DEN
30.0
Blown
176.0ft2
0.053
0.10
Wood
6121/2021 8:03,03 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
(Total Exposed Area = 2637 sq.ft.)
Cavity
Width
Height Area U-
Sheath Frm. Solar Below
VAdjacent
# Ornt
To
Wall Type
Space R-Value
Ft
In
Ft In sq.ft. Factor
R-Value Frac.
Absor. Grade
_ 1 N
Exterior
Cone. Blk - Ext Ins
BATH 3
4.1
8.0
0
10.0 0 80.0 0.131
0 0
0.60 0 %
-2 W
Exterior
Cone. Blk - Ext Ins
BATH 3
4.1
6.0
0
10.0 0 60.0 0.131
0 0
0.60 0 %
_ 3 W
Exterior
Cone. Blk - Ext Ins
BEDROOM 4
4.1
11.0
0
10.0 0 110.0 0.131
0 0
0.60 0 %
W
Exterior
Cone. Blk- Ext Ins
BEDROOM 3
4.1
12.0
0
10.0 0 120.0 0.131
0 0
0.60 0 %
_4
5 W
Exterior
Cone. Blk - Ext Ins
BATH 2
4.1
6.0
0
10.0 0 60.0 0.131
0. 0
0.60 0 %
_
6 W
Exterior
Cone. Blk - Ext Ins
BEDROOM 2
4.1
11.0
0
10.0 0 110.0 0.131
0 0
0.60 0 %
_
7 E
Exterior
Cone. Bilk - Ext Ins
;LAUNDRY
4.1
6.0
0
10.0 0 60.0 0.131
0 0
0.60 0 %
_
8 N
Exterior
Cone. Bilk - Ext Ins
FAMILY ROOM
4.1
15.0
0
10.0 0 150.0 0.131
0 0
0.60 0 %
_
E
Exterior
Cone. Blk - Ext Ins
FAMILY ROOM
4.1
17.0
0
10.0 0 170.0 0.131
0 0
0.60 0 %
-9
10 N
Exterior
Cone. Blk - Ext Ins
HALL
4.1
5.0
0
10.0 0 50.0 0.131
0 0
0.60 0 %
_
11 N
Exterior
Cone. Bik - Ext Ins
KITCHEN
4.1
4.0
0
10.0 0 40.0 0.131
0 0
0.60 0 %
_
12 N
Exterior
Cone. Blk - Ext Ins
DININGILIVING
4.1
14.0
0
11.0 0 154.0 0.131
0 0
0.60 0 %
_
13 E
Exterior
Cone. Blk - Ext Ins
DINING/LIVING
4.1
1.0
0
11.0 0 11.0 0.131
0 0
0.60 0 %
_
_ 14 S
Exterior
Cone. Bilk - Ext Ins
DINING/LIVING
4.1
25.0
0
11.0 0 275.0 0.131
0 0
0.60 0 %
15 W
Exterior
Cone. Blk - Ext Ins
DINING/LIVING
4A
2.0
0
11.0 0 22.0 0.131
0 0
0.60 0 %
_
16 N
Exterior
Cone. Blk - Ext Ins MASTER BEDROOM
4.1
9.0
0
10.0 0 90.0 0.131
0 0
0.60 0 %
_
17 NE
Exterior
Cone. Bilk - Ext Ins MASTER BEDROOM
4.1
4.0
3
10.0 0 42.5 0.131
0 0
0.60 0 %
_
18 E
Exterior
Cone. Blk - Ext Ins MASTER BEDROOM
4.1
13.0
0
10.0 0 130.0 0.131
0 0
0.60 0 %
_
19 W
Exterior
Cone. Blk - Ext Ins MASTER BEDROOM
4.1
8.0
0
10.0 0 80.0 0.131
0 0
0.60 0 %
_
20 NW
Exterior
Cone. Blk - Ext Ins MASTER BEDROOM
4.1
4.0
3
10.0 0 42.5 0.131
0 0
0.60 0 %
_
21 E
Exterior
Cone. Blk - Ext Ins
WIC
4.1
6.0
0
10.0 0 60.0 0.131
0 0
0.60 0 %
_
22 E
Exterior
Cone. Blk - Ext Ins
TLT
4.1
3.0
0
10.0 0 30.0 0.131
0 0
0.60 0 %
_
23 E
Exterior
Cone. Blk - Ext Ins
M BATH
4.1
12.0
0
10.0 0 120.0 0.131
0 0
0.60 0 %
_
24 E
Exterior
Cone. Blk - Ext Ins
DEN
4.1
10.0
0
10.0 0 100.0 0.131
0 0
0.60 0 %
_
25 S
Exterior
Cone. Bilk - Ext Ins
DEN
4.1
15.0
0
10.0 0 150.0 0.131
0 0
0.60 0 %
_
26 W
Exterior
Cone. Blk - Ext Ins
DEN
4.1
10.0
0
10.0 0 100.0 0.131
0 0
0.60 0 %
_
27 N
Garage
Frame - Wood
DEN
11.0
22.0
0
10.0 0 220.0 0.092
0.23
0.60 0 %
DOORS
(Total Exposed Area = 0 sq.ft.)
Width
Height
✓# Omt
Adjacent To Door Type
Space
Storms
U Value Ft In
Ft In
Area
1 N
Exterior
Wood
BATH 3
None
0.20 0.10 0
0.10 0
0.1ft2
WINDOWS
(Total Exposed Area = 401 sq.ft.)
Wall
---Overhang--
✓# Omt
ID Frame
Panes NFRC
U-Factor SHGC
Imp Storm
Area
Depth Separation
Interior Shade
Screening
_ 1 N
1 Metal
Low-E Single Yes
1.05 . 0.25
Y
N
6.0ft2
2.0 ft 0 in 1.0 ft 5 in
None
None
-2 W
3 Metal
Low-E Single Yes
1.05 0.25
Y
N
15.0ft2
2.0 ft 0 in 1.0 ft 5 in
None
None
W
4 Metal
Low-E Single Yes
1.05 0.25
Y
N
15.0ft2
2.0 ft 0 in 1.0 ft 5 in
None
None
-3
-4 W
5 Metal
Low-E Single Yes
1.05 0.25
Y
N
6.0ft2
2.0 ft 0 in 1.0 ft 5 in
None
None
W
6 Metal
Low-E Single Yes
1.05 0.25
Y
N
15.0ftl
2.0 ft 0 in 1.0 ft 5 in
None
None
-5
N
8 Metal
Low-E Single Yes
1.05 0.25
Y
N
20.0ft2
2.0 It 0 in 1.0 ft 5 in
None
None
-6
_ 7 E
9 Metal
Low-E Single Yes
1.05 0.25
Y
N
41.0ft2
20.0 ft 0 in 1.0 ft 5 in
None
None
8 E
9 Metal
Low-E Single Yes
1.05 0.25
Y
N
15.0ft2
10.0 ft 0 in 1.0 ft 5 in
None
None
_
N
10 Metal
Low-E Single Yes
1.05 0.25
Y
N
19.4ft2
2.0 ft 0 in 1.0 ft 5 in
None
None
-9
_„ 10N
11 Metal
Low-E Single Yes
1.05 0.25
Y
N
15.0ft2
10.0 ft 0 in 1.0 ft 5 in
None
None
11 N
12 Metal
Low-E Single Yes
1.05 0.25
Y
N
61.5ft2
20.0 ft 0 in 1.0 ft 5 in
None
None
_
12S
14 Metal
Low-E Single Yes
1.05 0.25
Y
N
38.2ft2
6.0 ft 0 in 1.0 ft 5 in
None
None
_
13S
14 Metal
Low-E Single Yes
1.05 0.25
Y
N
12.5ft2
6.0 ft 0 in 1.0 ft 5 in
None
None
_
14S
14 Metal
Low-E Single Yes
1.05 0.25
Y
N
30.0112
6.0 ft 0 in 1.0 ft 5 in
None
None
_
15N
16 Metal
Low-E Single Yes
1.05 0.25
Y
N
41.0ft2
10.0 ft 0 in 1.0 ft 5 in
None
None
_
16NE
17 Metal
Low-E Single Yes
1.05 0.25
Y
N
10.0ft2
2.0 ft 0 in 1.0 ft 5 in
None
None
17NW
20 Metal
Low-E Single Yes
1.05 0.25
Y
N
10.Oft2
2.0 ft 0 in 1.0 ft 5 in
None
None
18E
23 Metal
Low-E Single Yes
1.05 0.25
Y
N
15.0ft2
2.0 ft 0 in 1.0 ft 5 in
None
None
6/21/2021 8:03:04 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS(Continued)
1-19S 25 Metal Low-E Single
Yes 1.05 0.25 Y N 15.02 2.0 ft 0 in 1.0 ft 5 in None None
INFILTRATION
# Scope Method
SLA
CFM50 ELA EgLA
ACH
ACH50 Space(s)
1 Wholehouse Proposed ACH(50)
0.00032
2096 115.01 215.92
0.0995
5.0 All
GARAGE
# Floor Area
Roof Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 471 ft2
471 lit'
64 ft
loft 1
MASS
# Mass Type
Area
Thickness
Furniture Fraction Space
_ 1 Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
BATH 3
-2 Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
BEDROOM 4
Default(8 Ibs/sq.ft.)
0 ft2
O ft
0.30
BEDROOM 3
-3
_ 4 Default(8 Ibslsq.ft:)
0 ft2
O ft
0.30
BATH 2
_ 5 Default(8 Ibs/sq.ft.)
0 ft2
oft.
0.30
BEDROOM 2
6 Default(B Ibs/sq.ft.)
0 ft2
0 ft
0.30
;LAUNDRY
_
_ 7 Default(8 Ibstsq.ft.)
0 ft2
0 ft
0.30
PANTRY
_ 8 Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
FAMILY ROOM
_ 9 Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
HALL
_ 10 Default(8 Ibs/sq.fL)
0 ft2
0 ft
0.30
KITCHEN
_ 11 Default(8 Ibs/sq.ft)
0 ft2
0 ft
0.30
DININGILIVING
_ 12 Default(8 Ibs/sq.f .)
0 ft2
0 ft
0.30
MASTER BEDROOM
_ 13 Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
WVIC 2
_ 14 Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
WIC
_ 15 Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
TLT
_ 16 Default(8 lbs/sq.ft.)
0 ft2
0 ft
0.30
M BATH
17 Default(8 Ibs/sq.ft.)
0 ft2
0 ft
0.30
DEN
HEATING SYSTEM
# System Type
Subtype/Speed
AHRI # Efficiency Capacity
-Geothermal HeatPump---- Ducts Block
kBtu/hr Entry Power Volt Current
1 Electric Heat Pump
None/Single
HSPF: 8.50
45.0
0.00 0.00 0.00 sys#1 1
COOLING SYSTEM
# System Type
Subtype/Speed
AHRI # Efficiency
Capacity
Air Flow SHR Duct Block
kBtulhr
cfm
1 Central Unit
Split/Single
SEER:14.5
47.0
1410 0.70 sys#1 1
6/21/2021 8:03:04 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
Subtype
Location
EF(UEF) Cap Use
SetPnt
Fixture Flow Pipe Ins.
Pipe length
1 Electric
None
Garage
0.95 (0.93) 50.00 gal 61 gal
120 deg
Standard None
109
Recirculation
Recirc Control
Loop Branch Pump DWHR
Facilities Equal
DWHR
Other Credits
System
Type
length length power
Connected Flow
Eff
1 No
NA NA NA No
NA
NA
NA
None
DUCTS
--Supply
Return-
Air
CFM 25 CFM 25
HVAC #
JDuct
# Location
R-Value Area Location
R-Value Area Leakage Type .
Handler
TOT
OUT QN
RLF Heat Cool
1 Attic
6.0 250 ft2 Attic
6.0 65 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans: N
Cooling [] Jan
[] Feb [ ] Mar
[ ] Apr
[ ] May [X] Jun [X] Jul
[X] Aug
[X] Sep
[ ] Oct [.]
Nov [ j Dec
Heating [X] Jan
[X] Feb [X] Mar
[ ] Apr
[ ] May [ j Jun [ ] Jul
[ ] Aug
[ ] Sep
[ ] Oct [X] Nov [X] Dec
Venting [] Jan
[ ] Feb [X] Mar
[X] Apr
[ ] May [ j Jun [ ] Jul
[ ] Aug
[I Sep
[X] Oct [X] Nov [ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3 4 5 6
7
8 9
10
11 12
Cooling (WD)
AM 78
78
78 78 78 78
78
78
80 80
80 80
PM 80
80
80 80 78 78
78
78
78 78
78 78
Cooling (WEH)
AM 78
78
78 78 78 78
78
78
80 80
80 80
PM 80
80
80 80 78 78
78
78
78 78
78 78
Heating (IND)
AM 65
65
65 65 65 65
65
68
68 68
68 68
PM 68
68
68 68 68 68
68
68
68 68
68 68
Heating (WEH)
AM 65
65
65 65 65 65
65
68
68 68
68 68
PM 68
68
68 68 68 68
68
68
68 68
68 68
6/21/2021 8:03:04 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA"
Project Name: SMITH RESIDENCE Builder Name:
Street: 48001NDRIO RD. Permit Office:
City, State, Zip: FT. PIERCE, FL, Permit Number: Y
Owner: Jurisdiction:
iU
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed.
inch minimum
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered
Where provided instead of floor insulation, insulation
with a Class 1 vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and
conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal
Recessed light fixtures installed in the building
envelope shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers
Exterior walls adjacent to showers and tubs shall
• on exterior wall
and tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box
The air barrier shall be installed behind electrical or
on exterior walls
communication boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering
or ceiling penetrated by the boot.
Concealed
When required to be sealed, concealed fire sprinklers shall only
sprinklers
be sealed In a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between firesprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/21/2021 8:03:20 AM EnergyGaugeO USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1