HomeMy WebLinkAboutProduct Evaluation ReportR W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico. FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Swinging Plastpro Inc. ' Opaque Fiberglass Doors Exterior Doors Exterior Door 5200 W. Century Blvd. Doubles Assemblies Los Angeles, CA wl or wlout Sidelites Phone 440.969.9773 Inswing l Outswing - "Impact' Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for Plastpro Inc., based on Rule Chapter No. 61G20-3, Method I of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company . manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code structural requirements excluding the "High Velocity Hurricane Zone". 2.' Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level °D° and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1.;- 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing. FL-17347.14 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-17347.14 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01391141 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V. K Wright TEL 01390617 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V. K Wright TEL 01650058 TAS 201, 202 & 203-94 Testing Evaluation Lab.,lnc. Lyndon F. Schmidt, P.E. TEL 01391120 TAS 201, 202 & 203-94 Testing Evaluation Lab.,lnc. William B. Shelton, P.E. 2. Miami -Dade NOA Materials Testing 17-0712.05 Saflex° PVB Interlayer (Eastman Chemical Company) 3. Drawing No. Prepared by No. FL-17347.14 RW Building Consultants, Inc. (CA #9813) 4. Calculations Prepared by Anchoring RW Building Consultants, Inc. (CA#9813) 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Plastpro Inc. is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and t stj.SIiZ11111110 Guide 53. �`pt ,C. SCit 4/ ts00 sir No 43409 ° ST- 1 � O ' _ d�,,PsoC jN r�►fi �L � �q lob 18 Sheet 1 of 1 Signed & Sealed by Lyndon F. Schmidt, P.E. Siqned & Sealed by Lyndon F. Schmidt, P.E. Lyndon F. Schmidt, P.E. FL PE No. 43409 9/25/2017 �S l V —rERMANEN7\A-Florida PtoductAppravals\FL-17347 Fiberglass Door-ImpaR-nonimpa-.t\C- Drawings\FL-173476THED(2017)\FL-17347+3.14.dwg,22 ti • • 79.2Y MAX, PANEL HEIGHT a N � TO N W Z 113 -i�; o• _.1 m r :E 0 36.19" >0 m 5 0 �0 m K = M 1 1 n` r; :1 •'. Cm Om O S O 1�•�Q� 10 O O3. C,o. m p • •e�t� : ' . 9 n Q ±Tr v K ` wO vy p:. O = � m 0 �n `A z ZSA `>m Z tJ N D — Z m T� A n h I� A 0 • IT o t- y m 2 7 21/17 .-, IW v Un T 4 14 15 JUpj a P NO DATE 02014 R.W. BYILo1NG Camsu Ly^ws INC. G No.43409 PLASTPRO INC. Documents areperod 5r � ` Lyndon �� �ZOF80R•'• FIBERGLASS DOOR F. Schmidf \ �� P�.I- No. 43409 7 l�WO',.•, I ASSEMBLY' '11 }� BUILDING CONSUL7ANIS, lINNQ. DOOR `/ u( P•D- Box 23C, velr;w, FL 33595 PANEL DETAILS Phone Np-: 87:1659.9797 FBPE C.A. No_ satz