Loading...
HomeMy WebLinkAboutSewage OSTDS NewSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT SYSTEM CONSTRUCTION PERMIT FOR: OSTDS New AND DISPOSAL APPLICANT: Hopeton Smith PROPERTY ADDRESS: 4800 Indrio Rd Fort Pierce, FL 34951 RECEIVED FEB 0 12022 St. Luole County Permitting LOT: BLOCK: SUBDIVISION: PROPERTY ID #: 1418-133-0030-000-4 PERMIT #:66-SF-2374986 APPLICATION #:AP1733833 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR1677700 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 1,050 ] GALLONS / GPD Septic New CAPACITY A [ ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ D [ 667 ] SQUARE FEET R [ ] SQUARE FEET A TYPE SYSTEM: [X] I CONFIGURATION: [ ] N Drainfield New SYSTEM N/A SYSTEM STANDARD [ ] FILLED [ ] MOUND TRENCH [X] BED [ ] F LOCATION OF BENCHMARK: PAINTED X NAIL IN PINE TREE W OF PROPERTY. I ELEVATION OF PROPOSED SYSTEM SITE [ 9.00 ][INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 24.001 INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT L D i 0 T H E R '.L" REQUIRED: L 3.UU ] INCHES EXCAVATION REQUIRED: [ 0.00 ] INCHES The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 gpd. SPECIFICATIONS BY: //,Matthew S V janyi TITLE: Environmental Specialist I APPROVED BY: v TITLE: Environmental Specialist I St. Lucie CHD Matthew s I&Aan ' DATE ISSUED: /11/2021/ DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EXPIRATION DATE: 07/11/2023 v 1.1.4 AP1733833 SE1613662 Page 1 of 3 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a 'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. ABOVE THIS LINE -FOR OFFICIAL USE ONLY