KSM JOB #:219325-1d/JM/bm
NUC #234
Nuc Model:MC-DR
Nuc Serial #:MD60308234
1912 Lynx Drive
Ft. Pierce, Florida
Compacted Foundation Fill
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F)
PERCENT
COMPACTION
1 S.W.0" - 12"15 D 112.7 114.1 98.8%
2 N.W."14 D 110.0 "96.4%
3 Center "15 D 113.2 "99.2%
4 N.E."15 D 111.4 "97.6%
5 S.E."15 D 112.3 "98.4%
Proctor Optimum Moisture:
Proctor Max. Dry Density: P.C.F.
@ Test Locations the Density &
Penetrometer readings indicate the
Degree of Compaction Meets
2/8/2022
Brown Tan Sand With Traces Of Clay And Shell
Fragments
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE
Disclaimer:Contractor is responsible to maintain the tested area in
the condition that KSM completed the indicated passed
compaction test.KSM is not responsible if the tested area has been
altered from the approved inspected condition.
Julie E. Keller, P.E. President
PE # 68366
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
114.1
Minimum Requirement
For a Staked Foundation
Respectfully Submitted:
In Place Moisture:
11.3 %
10 %
TEST LOCATION
OF SAMPLE
Soil Description:
PERMIT #:
CONTRACTOR:Complete Construction
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
DATE TESTED:February 7, 2022
ITEM TESTED:
JOB LOCATION:
109.0
110.0
111.0
112.0
113.0
114.0
115.0
116.0
5 6 7 8 9 10 11 12 13
W
E
I
G
H
T
P
C
F
D
R
Y
Moisture -% of Dry Weight