HomeMy WebLinkAboutEPL Display Card4
Address of New Home:
ENERGY
PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 80
The lower the EnergyPerformance Index, the more efficient the home.
„ FL, -
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=4.3
1514.50 ft2
b. N/A
R=
ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
2 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No a. Under Attic (Vented)
R=30.0
1446.00 ft2
6. Conditioned floor area (ft2)
1446 b. N/A
R=
ft2
c. N/A
R=
ft2
7. Windows** Description
Area
11 . Ducts
R ft2
a. U-Factor: Dbl, U=1.30
114.00 ft2 a. Sup: Attic, Ret: Attic, AH: Attic
6 90
SHGC: SHGC=0.50
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
28.2 SEER:15.00
SHGC:
d. U-Factor: N/A
ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump
28.2
HSPF:8.60
Area Weighted Average Overhang Depth:
3.833 ft.
Area Weighted Average SHGC:
0.500
8. Floor Types Insulation Area 14. Hot water systems
Cap:
40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1446.00 ft2 a. Electric
EF: 0.9
b. N/A R=
ft2
b. Conservation features
c. N/A R=
ft2
None
15. Credits
CF, Pstat
I certify that this home has complied with the Florida Energy Efficien
Construction through the above energy saving features which will
in this home before final inspection. Otherwis new EPL Dis ay
based on installed Code compliant feattwis!
R
City/FL Zip:'�,�Qj��.
Date
c Code for Building
installed (or exceeded)
Card will be completed
'6
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if n A T.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software