HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 62' WYNNE GRAND CARLTON
Builder Name: COMFORT CONTROL OF SLC, INC.
Street: '� L]
CQS�S
Permit Office:
City, State, Zip: FL, -
Permit Number:
Owner: GRAND CARLTON
62'
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing
New (From Plans)
9. Wall Types (1514.5 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.3 1514.50 ft2
b. N/A
R= ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
2
d. N/A
R= ft2
10. Ceiling Types (1446.0 sqft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2)
1446
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c.
R= ft2
11. Ducts
R ft2
7. Windows(114.0. sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 90
a. U-Factor: Dbl, U=1.30
114.00 ft2
SHGC: SHGC=0.50
b. U-Factor: N/A
ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
28.2 SEER:15.00
c. U-Factor: N/A
ft2
• SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Heat Pump
28.2 HSPF:8.60
SHGC:
Area Weighted Average Overhang Depth: 3.833 ft.
Area Weighted Average SHGC:
0.500
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1446.0 sqft.)
Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation
R=0.0 1446.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.079
Total Proposed Modified Loads: 26.16
PASS
Total Standard Reference Loads: 32.81
I hereby certify that the plans and specifications covered by
Review of the plans and
111101009'0JE SrATB
this calculation are in co Hance wit
Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
rrr,, . '�h� ;•-° ';' �. „ O
PREPARE B :
Befor construction is completed
c Z„
DATE:
thi uilding will be inspected for
k�
mpliance with Section 553.908
*
I hereby certify that this build' d
ed, is in compliance
Florida Statutes.
CAD
with the Florida Ener ode.
WE
rc4
OWN,ER/A r= , " !
NOW
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure
qualifies as certified factory -sealed in accordance with 403.2.2.1.1.
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
FILLOO COPY
5/15/2012 9:20 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
62' WYNNE GRAND CARLT
FLProp2010
GRAND CARLTON 62'
1
COMFORT CONTROL OF SL
Single-family
New (From Plans)
Bedrooms: 2
Conditioned Area: 1446
Total Stories: 1
Worst Case: No
Rotate Angle: 45
Cross Ventilation: No
Whole House Fan: No
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
ST. LUCIE
FL, -
CLIMATE
Design Location TMY Site
IECC Design Temp
Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_ST LUCIE_CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name Area
Volume
1
Blockl 1446
11568
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
RoomslnBlockl 1446
11568 Yes 2
2
1 Yes
Yes Yes
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio RoomslnBlockl 150.7 ft 0
1446 ft2
__-_
0 0 1
ROOF
/
V #
Type Materials
Roof Gable Roof
Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip Metal
1523 ft2 0 ft2 Medium
0.88
N 0.9
No 0 18.4
ATTIC
V #
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic Vented 300 1445 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Vented) RoomslnBlockl 30 1446 ft2
0.1
Wood
5/15/2012 9:20 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
it
Ornt TO Wall Tvn, Space
R-VaIUP Ft In Ft
In
ACPa
R-value
FraM. ipn Ahs
°
1
N Exterior Concrete Block - Int InsRoomsInBIoc
4.3 32 2 9
10
316.3055
0
0 0.8
0
2
E Exterior Concrete Block - Int InsRoomsInBloc
4.3 49 11 9
10
490.8472
0
0 0.8
0
3
S Exterior Concrete Block - Int InsfAoomslnBloc
4.3 15 6 8
0
124 ft2
0
0 0.8
0
4
SW Exterior Concrete Block - Int Ins6loomslnBloc
4.3 4 3 8
0
34 ft2
0
0 0.8
0
5
W Exterior Concrete Block - Int InsRoomSInBloc
4.3 35 2 8
0
281.3333
0
0 0.8
0
6
W Exterior Concrete Block - Int Ins6loomsInBloc
4.3 8 0 8
0
64 ft2
0
0 0.8
0
7
S Exterior Concrete Block - Int InsRoomsInBIoc
4.3 25 6 8
0
204 ft2
0
0 0.8
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 S=>E Insulated RoomslnBloc
Metal
0.6 3
0
7 0
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt ID Frame Panes NFRC U-Factor SHGC Storms
Area
Depth
Separation
Int Shade
Screening
1
N=>W 1 Metal Double (Tinted) Yes
1.3 0.5 N
27 ft2
10 ft 0 in
0 ft 6 in
HERS 2006
None
2
N=>W 1 Metal Double (Tinted) Yes
1.3 0.5 N
15 ft2
1 ft 0 in
0 ft 6 in
HERS 2006
None
3
N=>W 1 Metal Double (Tinted) Yes
1.3 0.5 N
15 ft2
1 ft 0 in
0 ft 6 in
HERS 2006
None
4
E=>N 2 Metal Double (Tinted) Yes
1.3 0.5 N
20 ft2
1 ft 0 in
0 ft 6 in
HERS 2006
None
5
E=>N 2 Metal Double (Tinted) Yes
1.3 0.5 N
15 ft2
1 ft 0 in
0 ft 6 in
HERS 2006
None
6
S=>E 3 Metal Double (Tinted) Yes
1.3 0.5 N
16 ft2
6 ft 0 in
0 ft 6 in
HERS 2006
None
7
W=>S 5 Metal Double (Tinted) Yes
1.3 0.5 N
6 ft2
1 ft 0 in
0 ft 6 in
HERS 2006
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 382.8 ft2 382.8 ft2
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 BySpaces Proposed SIA 0.000360 1365.4 74.960 140.97
0.2628
7.0821
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump None
HSPF: 8.6
28.2 kBtu/hr
1
sys#1
5/15/2012 9:20 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit
None
SEER: 15 28.2 kBtu/hr 846 cfm
0.8
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.9 40 gal
50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
---- Return ----
Air
Percent
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
CFM 25
Leakage
QN
RLF
Heat Cool
1 Attic
6 90 ft2
Attic
25 ft2 DSE=0.88
Attic
0.0 cfm
0.00 % 0.00
0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling X] Jan Feb
Mar
Apr
Xjj May Jun jj Jul
X Aug
Sep
Oct
Nov
Dec
XFebMar
Heating E 1 JanJXJ
r
�Xj
JXXJApr
X] Jul
] May JXXJ Jun IX
IX
Ag
jXXj Sep
�Xxl Oct
JXXJ Nov
�XXJ Dec
Ventin Jan X Feb
Mar
X Apr
Xjj May X Jun X]] Jul
[X Au
lX�
X Se
X Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (VVEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
FIL C-Opte
5/15/2012 9:20 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Yge 4 of 5
11
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT #:
, FL, -
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required'for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4116/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
ILE
5/15/2012 9:20 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 5 of 5