Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HOMECRETE-INGRAM RES Builder Name: HOMECRETE HOMES Street: DYER RD Permit Office: City,State,Zip: PORT ST LUCIE,FL, Permit Number: Owner: INGRAM RES. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall TypeV219.3 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=6.5 1999.30 ft2 b. Frame-Wood,Adjacent R=11.0 220.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11.Ceiling Types (2266.0 sqft.) Insulation Area a. Roof Deck(Unvented) R=20.0 2266.00 ft2 6. Conditioned floor area above grade(ft2) 2266 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 7. Windows(289.1 sqft.) Description Area 12.Ducts R ft2 a.Sup:Attic, Ret:Attic,AH:Attic 6 320 a. U-Factor: Dbl, U=0.29 214.46 ft2 SHGC: SHGC=0.26 b. U-Factor: Dbl,U=0.32 74.60 ft2 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.26 a. Central Unit 35.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 5.743 ft. 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.260 a. Electric Heat Pump 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot water systems SHGC(AVG): N/A a.Electric Cap:50 gallons 9. Floor Types (2266.0 sqft.) Insulation Area EF:0.930 a.Slab-On-Grade Edge Insulation R=0.0 2266.00 ft2 b. Conservation features b. N/A R= ft2 None c.N/A R= ft2 16.Credits Pstat Glass/Floor Area: 0.128 Total Proposed Modified Loads: 68.87 PASS Total Baseline Loads: 74.01 I I hereby certify that the plans and specifications covered by Review of the plans and O -TEiE ST,q � this calculation are in compliance wit the Florida Energy specifications covered by this _N� Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed ¢ DATE: this building will be inspected for _' ��^ •x► compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. ✓"V with the Florida Energy Code. BCDWE OWNER/AGE BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 10/26/2021 11:01 AM EnergyGaugeO USA 7.0.00-FlaRes2021 FBC 7th Edition(2020) Compliant Software Page 1 of 6 i FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HOMECRETE-INGRAM RE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2266 Lot# Owner Name: INGRAM RES, Total Stories: 1 BlocklSubdivisiom #of Units: 1 Worst Case: No PlatBook: Builder Name: HOMECRETE HOMES Rotate Angle: 0 Street: DYER RD Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City,State,Zip: PORT ST LUCIE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.6% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2266 22660 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 2 182 1820 No 1 4 1 No Yes Yes 2 BATH 2 60 600 No 0 1 No Yes Yes 3 BEDROOM 3 168 1680 No 1 1 No Yes Yes 4 DINING ROOM 436 4380 No 0 1 No Yes Yes 5 GREAT ROOM 320 3200 No 0 1 No Yes Yes 6 NOOK 88 880 No 0 1 No Yes Yes 7 KITCHEN 200 2000 No 0 1 No Yes Yes 8 LAUNDRY 70 700 No 0 1 No Yes Yes 9 MASTER TOILET 26 260 No 0 1 No Yes Yes 10 MASTER BATH 144 1440 No 0 1 No Yes Yes 11 WIC MASTER INT 48 480 No 0 1 No Yes Yes 12 WIC MASTER EXT 48 480 No 0 1 No Yes Yes 13 MASTER SUITE 300 3000 No 2 1 No Yes Yes 14 BEDROOM 4 138 1380 No 1 1 No Yes Yes 15 CABANA BATH 36 360 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 2 40 ft 0 182 ft2 ---- 0 1 0 2 Slab-On-Grade Edge Insulatio BATH 2 6 ft 0 60 ft2 ---- 1 0 0 3 Slab-On-Grade Edge Insulatio BEDROOM 3 12 ft 0 168 ft2 _--- 0 1 0 10/26/2021 11:01 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 4Slab-On-Grade Edge Insulatio DINING ROOM 11 ft 0 438 ft2 0 1 0 5 Slab-On-Grade Edge Insulatio GREAT ROOM 27 ft 0 320 ft2 _-__ 0 1 0 6 Slab-On-Grade Edge Insulatio NOOK 17 ft 0 88 ft2 __-_ 0 1 0 7 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 200 ft2 ____ 1 0 0 8 Slab-On-Grade Edge Insulatio LAUNDRY 7 ft 0 70 ft2 ___- 1 0 0 9 Slab-On-Grade Edge Insulatio MASTER TOILET Oft 0 26 ft2 -_-_ 1 0 0 10SIab-On-Grade Edge Insulatio MASTER BATH 20 ft 0 144 ft2 1 0 0 11SIab-On-Grade Edge Insulatio WIC MASTER IN 1 ft 0 48 ftz _-__ 0 1 0 12SIab-On-Grade Edge Insulatio WIC MASTER EX 8 ft 0 48 ft2 ____ 0 1 0 13SIab-On-Grade Edge Insulatio MASTER SUITE 31 ft 0 300 ft2 0 1 0 14SIab-On-Grade Edge Insulatio BEDROOM 4 19.5 ft 0 138 ft2 __-_ 0 1 0 15Slab-On-Grade Edge Insulatio CABANA BATH 18 ft 0 36 ft2 ____ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2454 ftz 0 ft2 Medium N 0.9 No 0.9 No 20 22.6 / ATTIC v # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 2266 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) BEDROOM 2 0 Blown 182 ftz 0.1 Wood 2 Under Attic(Unvented) BATH 2 0 Blown 60 ftz 0.1 Wood 3 Under Attic(Unvented) BEDROOM 3 0 Blown 168 ft2 0.1 Wood 4 Under Attic(Unvented) DINING ROOM 0 Blown 438 ft2 0.1 Wood 5 Under Attic(Unvented) GREAT ROOM 0 Blown 320 ft2 0.1 Wood 6 Under Attic(Unvented) NOOK 0 Blown 88 ft2 0.1 Wood 7 Under Attic(Unvented) KITCHEN 0 Blown 200 ft2 0.1 Wood 8 Under Attic(Unvented) LAUNDRY 0 Blown 70 ft2 0.1 Wood 9 Under Attic(Unvented) MASTER TOILET 0 Blown 26 ft2 0.1 Wood 10 Under Attic(Unvented) MASTER BATH 0 Blown 144 ft2 0.1 Wood 11 Under Attic(Unvented) WIC MASTER IN 0 Blown 48 ft2 0.1 Wood 12 Under Attic(Unvented) WIC MASTER EX 0 Blown 48 ft2 0.1 Wood 13 Under Attic(Unvented) MASTER SUITE 0 Blown 300 ft2 0.1 Wood 14 Under Attic(Unvented) BEDROOM 4 0 Blown 138 ft2 0.1 Wood 15 Under Attic(Unvented) CABANA BATH 0 Blown 36 ft' 0.1 Wood 10/26/2021 11:01 AM EnergyGauga USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below -01rit To Wall Tvnim8 _ 1 N Exterior Concrete Block-Int Ins8EDROOM 2 6.5 16 3 8 0 130.0 ft2 0 0 0.5 0 2 S Exterior Concrete Block-Int InsBEDROOM 2 6.5 15 0 8 0 120.0 ft2 0 0 0.5 0 3 W Exterior Concrete Block-Int InsSIEDROOM 2 6.5 18 9 8 0 150.0 ft2 0 0 0.5 0 4 S Exterior Concrete Block-Int Insul BATH 2 6.5 7 6 8 0 60.0 ft2 0 0 0.5 0 - 5 S Exterior Concrete Block-Int InsBEDROOM 3 6.5 15 0 8 0 120.0 ft2 0 0 0.5 0 - 6 W Exterior Concrete Block-Int InsQINING ROO 6.5 7 9 8 0 62.0 ft2 0 0 0.5 0 7 E Exterior Concrete Block-Int InsQREAT ROO 6.5 20 0 8 0 160.0 ft2 0 0 0.5 0 - 8 W Exterior Concrete Block-Int InsC9REAT ROO 6.5 13 9 8 0 110.0 ft2 0 0 0.5 0 9 E Exterior Concrete Block-Int Insul NOOK 6.5 11 3 8 0 90.0 ft2 0 0 0.5 0 10 S Exterior Concrete Block-Int Insul NOOK 6.5 10 0 8 0 80.0 ft2 0 0 0.5 0 _11 N Exterior Concrete Block-Int InsMASTER BA 6.5 11 3 8 0 90.0 ft2 0 0 0.5 0 _12 N Exterior Concrete Block-Int InsWIC MASTE 6.5 10 0 8 0 80.0 ft2 0 0 0.5 0 _13 N Exterior Concrete Block-Int InsMASTER SUI 6.5 20 0 8 0 160.0 ft2 0 0 0.5 0 _14 E Exterior Concrete Block-Int InsMASTER SUI 6.5 18 9 8 0 150.0 ft2 0 0 0.5 0 15 E Exterior Concrete Block-Int InsBEDROOM 4 6.5 10 0 8 0 80.0 ft2 0 0 0.5 0 16 S Exterior Concrete Block-Int InsBEDROOM 4 6.5 14 5 8 0 115.3 ft2 0 0 0.5 0 _17 N Exterior Concrete Block-Int InsIBABANA BA 6.5 7 6 8 0 60.0 ft2 0 0 0.5 0 _18 S Exterior Concrete Block-Int Insi0ABANA BA 6.5 7 6 8 0 60.0 ft2 0 0 0.5 0 _19 W Exterior Concrete Block-Int Insi0ABANA BA 6.5 7 6 8 0 60.0 ft2 0 0 0.5 0 _20 N Garage Frame-Wood MASTER BA 11 22 0 10 0 220.0 ft2 0 0 0.5 0 _21 W Exterior Concrete Block-int InSDIINING ROO 6.5 7 9 8 0 62.0 ft2 0 0 0.5 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated DINING ROO None .39 3 7 6 8 23.9 ft2 2 S Insulated CABANA BA None .39 3 4 6 8 22.2 ft2 3 N Wood MASTER BA None .39 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 3 Metal Double(Tinted) Yes 0.29 0.26 N 15.8 ft2 1 ft 6 in 1 ft 0 in None None 2 S 4 Metal Double(Tinted) Yes 0.29 0.26 N 10.0 ft2 1 ft 0 in 1 ft 0 in None None 3 S 5 Metal Double(Tinted) Yes 0.29 0.26 N 15.8 ft2 1 ft 0 in 1 ft 0 in None None 4 W 21 Metal Double(Tinted) Yes 0.29 0.26 N 32.4 ft2 7 ft 0 in 1 ft 0 in None None 5 E 7 Metal Double(Tinted) Yes 0.32 0.26 N 74.6 ft2 12 ft 0 in 1 ft 0 in None None 6 W 8 Metal Double(Tinted) Yes 0.29 0.26 N 15.8 ft2 1 ft 0 in 1 ft 0 in None None 7 E 9 Metal Double(Tinted) Yes 0.29 0.26 N 15.8 ft2 1 ft 0 in 1 ft 0 in None None 8 S 10 Metal Double(Tinted) Yes 0.29 0.26 N 15.8 ft2 23 ft 0 in 1 ft 0 in None None 9 N 11 Metal Double(Tinted) Yes 0.29 0.26 N 13.0 ft2 1 ft 0 in 1 ft 0 in None None 10 N 13 Metal Double(Tinted) Yes 0.29 0.26 N 32.0 ft2 1 ft 0 in 1 ft 0 in None None 11 E 14 Metal Double(Tinted) Yes 0.29 0.26 N 32.1 ft2 1 ft 0 in 1 ft 0 in None None 10126/2021 11:01 AM EnergyGaugeOD USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang �/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 12 S 16 Metal Double(Tinted) Yes 0.29 0.26 N 16.8 ft2 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wail Insulation 1 467 ft2 467 ft2 64 ft loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000317 1888.3 103.6 194.5 .0987 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 50921 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ---Supply-- ---Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RLF Heat Cool 1 Attic 6 320 ft2 Attic 150 ft2 Default Leakage Attic (Default) (Default) 1 1 10/26/2021 11:01 AM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooiin [( ]]Jan HFeb [[ ]]Mar Apr May X Jun ri Jul X AugX Se Oct Nov Dec Heating [X]Jan Feb [X]Mar Apr May Jun Jul Aug Sep €X�Oct Lx1 Nov Dec Venting [[ 11 Jan Feb [[XX]]Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 It 0.3 BATH 2 Default(8 Ibs/sq.ft, ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 It 0.3 DINING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 tbs/sq.ft. ft2 ft 0.3 NOOK Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER TOILET Default(8 lbs/sq.ft, ft2 ft 0.3 MASTER BATH Default(8 lbsisq.ft. ft2 ft 0.3 WIC MASTER INT Default(8 Ibs/sq.ft. ft2 It 0.3 WIC MASTER EXT Default(8 Ibslsq.ft. ft2 ft 0.3 MASTER SUITE Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/s .ft. ft2 ft 0.3 CABANA BATH 10/26/2021 11:01 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. DYER RD, PORT ST LUCIE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=6.5 1999.30 ftT b.Frame-Wood,Adjacent R=11.0 220.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area a.Roof Deck(Unvented) R=20.0 2266.00 ft2 6. Conditioned floor area(ft2) 2266 b. N/A R= ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.29 214.46 ft2 12. Ducts, location&insulation level R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 320 SHGC: SHGC=0.26 b. U-Factor: Dbl,U=0.32 74.60 ft2 SHGC: SHGC=0.26 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 35.0 SEER:16.00 SHGC: d. U-Factor: N/A ftZ 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average Overhang Depth: 5.743 ft. Area Weighted Average SHGC: 0.260 8. Description Skylights tion Area 15. Hot water systems p Cap:50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF:0.93 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab-On-Grade Edge Insulation R=0.0 2266.00 ft2 Credits(Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: �d Date: T Address of New Home: City/FL Zip: WE 3 y`L5 CP- *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/26/2021 11:01 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 Project Summa Dat esL Bate: LINDSTROM Enure House Y wLindstrom Air Conditioning 3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromair.com Proiect Information For: HOMECRETE Notes: INGRAM RES. Design e • Weather: St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23749 Btuh Structure 21692 Btuh Ducts 3029 Btuh Ducts 2293 Btuh Central vent (72 cfm) 2287 Btuh Central vent (72 cfm) 1214 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29066 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25199 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3335 Btuh Ducts 1645 Btuh Central vent (72 cfm) 2773 Btuh Heatingg Cooling Outside air Area (ft2 2266 2266 Equipment latent load 7753 Btuh Volume(ft3) 22660 22660 Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 32952 Btuh Equiv.AVF (cfm) 121 60 Req. total capacity at 0.80 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER ade Trade Model CH16NA036 Cond CH16NA036 AHRI ref Coil FX4DNF037 AHRI ref Efficiency 8.5 HSPF Efficiency 16 SEER Heating Input Sensible cooling 28000 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 7000 Btuh Temperature rise 26 OF Total cooling 35000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.050 cfm/Stuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.76 Capacity balance point= 0 OF Backup: CARRIER 5 KW Input= 9 kW, Output= 29939 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - - wrightsaft" 2021-Oct-26 11:02:07 ..» .„ .•..»a- -». Right-Suite®Universal 2019 19.0.12 RSU08398 Page 1 /�� ...RGY1A-MANUAL JIHOMECRETE-INGRAM RES-FTP.rup Cale=MJ8 Front Door iaces: W Right-J®O/�orfcsheet Job: Ontire House Date: LINDS4 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD,POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name Entire House BEDROOM 2 2 Exposed wall 220.5 ft 40.0 ft 3 Room height 10.0 ft 10.0 ft heat/coot 4 Roam dimensions 13.0 x 14.0 ft 5 Roan area 2266.0 ft2 182.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (W) Load number (Btuh/ft?°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cc01 Gross N/PIS Heat Cool 6 13A-6ocs 0.111 n 3.22 1.79 520 475 1529 849 130 130 418 232 ID-h2om 0.290 n 8.41 13.69 32 0 269 438 0 0 0 0 iD-h2om 0.290 n 8.41 13.69 13 0 109 178 0 0 0 0 13A-6ocs 0.111 e 3.22 1.79 480 358 1152 640 0 0 0 0 11 1D-h2om 0.290 a 8.41 46.75 16 0 135 748 0 0 0 0 1D-h2om 0.290 e 8.41 46.75 32 0 269 1496 0 0 0 0 1D-h2ornd 0.320 e 9.28 14.15 74 148 687 1047 0 0 0 0 13A-6ocs 0.111 s 3.22 1.79 555 475 1529 849 120 120 386 214 1 D-h2cm 0.290 s 8.41 13.91 32 56 269 445 0 0 0 0 10-h2cm 0.290 s 8.41 13.69 10 20 84 137 0 0 0 0 1D-h2om 0.290 s 8.41 13.69 16 32 135 219 0 0 0 0 11DO 0.390 s 11.31 11.43 22 22 249 251 0 0 0 0 W 13A-60cs 0.111 w 3.22 1.79 430 342 1101 611 150 134 431 239 1 D-h2om 0.290 w 8.41 46.75 32 0 269 1496 0 0 0 0 ID-h2om 0.290 w 8.41 45.13 16 2 135 722 16 1 135 722 1E-h2fm 0.290 w 8.41 26.87 16 19 135 430 0 0 0 0 11 DO 0.390 w 11.31 11.43 24 24 271 274 0 0 0 0 12B-Obw 0.097 - 2.81 0.86 220 198 557 175 0 0 0 0 II-D 11 DO 0.390 is 11.31 11.43 22 22 249 251 0 0 0 0 C 16B-19md 0.049 s 1.42 2.59 2266 2266 3220 6863 182 182 259 471 F 22A-tpm 1.180 s 34.22 0.00 2266 221 7546 0 182 40 1369 0 6 c)AED excursion 0 229 Envelope loss!gain 19898 17119 2998 2108 12 a) Infiltration 3852 1023 776 206 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 5 1150 1 230 Appliances/other 2400 1 1 0 Subtotal(lines 6 to 13) 23749 21692 3774 2544 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23749 216921 3774 2544 15 Duct loads 13% 111% 3029 2293 13% 11% 481 269 Total room load 26779 23984 4256 2813 Air required(cfm) L-120011200 191 141 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ F}et wrightsaft` 2021-Oct-2611:02:07 Right-Suite)Universal 2019 19.0.12 RSU08398 Page 1 �` ...RGY\A-MANUAL J\HOMECRETE-INGRAM RES-FTP.rup Calc=MJ8 Front Door faces: W Right-J® Worksheet Job: Entire House Date: 10-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954.420-0064 Web:www.lindstrornair.com 1 Room name BATH 2 BEDROOM 3 2 Exposed wall 6.0 ft 12.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 6.0 x 10.0 ft 12.0 x 14.0 ft 5 Room area 60 0 ft' 168.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft') Load number (Btul1/ft1-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 V6 13A-6ocs 0.111 n 3.22 1.79 0 0 0 0 0 0 0 0 1D-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 1D-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 V1��JJ 13A-6ocs 0.111 e 3.22 1.79 0 0 0 0 0 0 0 0 11 1D-h2om 0,290 e 8,41 46.75 0 0 0 0 0 0 0 0 1 D-h2om 0.290 e 8.41 46.75 0 0 0 0 0 0 0 0 1 D-h2omd 0.320 e 9.28 14.15 0 0 0 0 0 0 0 0 13A-6ocs 0.111 s 3.22 1.79 60 50 161 89 120 104 335 186 1 D-h2om 0.290 s 8.41 13.91 0 0 0 0 16 14 135 223 1 D-h2om 0.290 s 8.41 13.69 10 10 84 /37 0 0 0 0 1 D-h2om 0.290 s 6.41 13.69 0 0 0 0 0 0 0 0 11DO 0.390 s 11,31 11.43 0 0 0 0 0 0 0 0 W 13A-60cs 0.111 w 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.41 46.75 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.41 45.13 0 0 0 0 0 0 0 0 1 E-h2fm 0.290 w 8.41 26,87 0 0 0 0 0 0 0 0 11 DO 0.390 w 11.31 11.43 0 0 0 0 0 0 0 0 R 12B-Obw 0.097 - 2.81 0,88 0 0 0 0 0 0 0 0 L--0 11 DO 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 C 16B-19md 0.049 s 1.42 2.59 60 60 85 155 168 168 239 435 F 22A-tpm 1.180 s 34.22 0.00 60 6 205 0 168 12 411 0 6 c)AED excursion -27 -61 Envelope loss/gain 536 354 1119 782 12 a) Infiltration 116 31 233 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 652 385 1352 1074 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 652 385 1352 1074 15 Duct loads 13% 11% 83 41 13% 11% 172 114 Total room load 735 426 1524 1188 Air required(cfm) 33 21 68 59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed 4cc�. -f wrightsott^ Right-Suite®Universal 2019 19.0.12 RSU08398 2021-Oct-2611:02:07Page 2 ..RGY1A-MANUAL JIHOMECRETE-INGRAM RES-FTprup Calc=MJB Front Door faces: W Right-J®Worksheet Job: Entire House oats: 10-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD.POMPANO BEACH,FL 33069 Phone:954421-4117 Fax 954-420-0064 Web:www,lindstromair.com 1 Room name DINING ROOM GREAT ROOM 32 Exposed Room ) 27.0 ft height %0 ft 11 0 ft heat/cool 10.0 ft heat/cW 4 Room dimensions 20.0 x 21.9 ft 20.0 x 16.0 ft 5 Room area 438.0 ft2 320.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftx-°F) (Stuhlft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/PIS Heat I Cool Gross N/P/S Heat I Cool 6 T 13A-6ocs 0.111 n 3.22 1.79 0 0 0 0 0 0 0 0 L-�{^ 1 D-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 iD-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 13A-6ocs 0.111 a 3.22 1.79 0 0 0 0 160 86 277 154 11 1 D-h2om 0.290 a 8.41 46.75 0 0 0 0 0 0 0 0 1 D-h2om 0.290 a 8.41 46.75 0 0 0 0 0 0 0 0 1 D-h2omd 0.320 a 9.28 14.15 0 0 0 0 74 74 687 1047 13A-60cs 0.111 s 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0,290 s 8.41 13.91 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13.69 0 0 0 0 0 0 0 0 1 D-112om 0.290 s 8.41 13.69 0 0 0 0 0 0 0 0 11 DO 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 13A-6ocs 0.111 w 3.22 1.79 110 54 174 97 110 94 303 168 1D-h2om 0.290 w 8.41 46.76 16 0 136 748 16 0 136 748 ID-h2om 0.290 w 8.41 45.13 0 0 0 0 0 0 0 0 1 E-h2fm 0.290 w 8.41 26.87 16 10 135 430 0 0 0 0 11 DO 0.390 w 11.31 11.43 24 24 271 274 0 0 0 0 12B-Obw 0.097 - 2.81 0.88 0 0 0 0 0 0 0 0 q-D 11DO 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 C 16B-19md 0.049 s 1.42 Z59 438 438 622 1133 320 320 455 828 F 22A tpm 1.180 s 34.22 0.00 438 11 376 0 320 27 924 0 6 c)AED excursion 681 -n Envelope loss/gain 1713 3363 2779 2868 12 a) Infiltration 213 57 524 139 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 to, 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 1927 34 3303 3007 Less external load 0 0 0 Less transfer 0 0 0 Redistribution 0 014 Subtotal 1927 34 330315 Duct loads 13% 11% 246 313% 11°h 421 318 Total room load 2172 3781 1 3725 3325 Air required(cfm) 1 1 97 189 167 16B Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 'f i'� wright�ott-..�* --• - Right-Suite®Universal 2019 19.0.12 RSU08398 2021-Oct-26 11:02:07 Page 3 ...RGY\A-MANUAL JIHOMECRETE-INGRAM RES-FTP.rup Cale=MJ8 Front Door faces: W Right-J® N4lorksheet Job: Entire House Bate: 10-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name NOOK KITCHEN 2 Exposed wall 17.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heaticool 4 Room dimensions 11.0 x 8.0 ft 10.0 x 20.0 ft 5 Room area 88.0 W 200.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btui1/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-60cs 0.111 n 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 1 D-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 VVVVVVjjj���JJJ111 13A-6ocs 0.111 e 3.22 1.79 90 74 238 132 0 0 0 0 1 1 1 D-h2om 0.290 a 8.41 46.75 16 0 135 748 0 0 0 0 1 D-h2om 0.290 e 8.41 46.75 0 0 0 0 0 0 0 0 1 D-h2omd 0.320 e 9.28 14.15 0 0 0 0 0 0 0 0 13A-6ocs 0.111 s 3.22 1.79 80 64 206 114 0 0 0 0 1 D-h2om 0.290 s 8.41 13.91 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13.69 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13.69 16 16 135 219 0 0 0 0 11 DO 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 W 13A-6ocs 0.111 w 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.41 46.75 0 0 0 0 0 0 0 0 1D-h2om 0.290 w 8.41 45.13 0 0 0 0 0 0 0 0 1E-h2fm 0,290 w 8.41 26.87 0 0 0 0 0 0 0 0 11DO 0.390 w 11.31 11.43 0 0 0 0 0 0 0 0 12B-Obw 0.097 - 2.81 0.88 0 0 0 0 0 0 0 0 D 1100 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 C 168-19md 0.049 s 1.42 2.59 88 88 125 228 200 200 284 517 F 22A-tpm 1.180 s 34.22 0.00 88 17 582 0 200 0 0 0 6 c)AED excursion -82 -161 Envelope loss/gain 1420 1359 284 356 12 a) Infiltration 330 88 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 0 0 Appliances/other 0 1800 Subtotal(lines 6 to 13) 1 1750 1446 284 2156 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1750 1446 284 2156 15 Duct loads 1 13% 11% 223 153 13% 11% 36 228 Total room load 1973 1599 320 2384 Air required(cfm) 88 80 1 14 119 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -F}t vvrightsoftu 2021-Oct-2611:02:07 ^...,..^°• •.•�^- - • Right-Suites Universal 2019 19.0.12 RSU08398 Page 4 ...RGY\A-MANUAL JIHOMECRETE-INGRAM RES-FTP.rup Cale=MJ8 Front Door faces: W Right-JO Worksheet yob. s' Entire House Date: 10-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromair.com 1 Room name LAUNDRY MASTER TOILET 2 Exposed wall 7.0 ft 4.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 10.0 x 7.0 ft 4.0 x 6.5 ft 5 Room area 70.0 ft' 26.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft?°F) (Stull/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-60cs 0,111 n 3.22 1.79 0 0 0 0 0 0 0 0 1D-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 ID-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 13A-6ocs 0.111 e 3.22 1.79 0 0 0 0 0 0 0 0 1 1 1 D-h2om 0.290 a 8.41 46.75 0 0 0 0 0 0 0 0 ID-h2om 0.290 a 8.41 46.75 0 0 0 0 0 0 0 0 -G 1 D-h2omd 0,320 e 9.28 14.15 0 0 0 0 0 0 0 0 \1 13A-6ocs 0.111 s 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13.91 0 0 0 0 0 0 0 0 ^ 1 D-h2om 0.290 s 8.41 13.69 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13.69 0 0 0 0 0 0 0 0 D 11 DO 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 Ud 13A-6ocs 0.111 w 3.22 1.79 0 0 0 0 0 0 0 0 lD-h2om 0.290 w 8.41 46,75 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.41 45.13 0 0 0 0 0 0 0 0 1E-h2fm 0.290 w 8.41 26.87 0 0 0 0 0 0 0 0 11 DO 0.390 w 11.31 11.43 0 0 0 0 0 0 0 0 R 12B-Obw 0.097 • 2.81 0.88 70 48 135 42 40 40 113 35 t-p 11DO 0.390 s 11.31 11.43 22 22 249 251 0 0 0 0 C 16B-19md 0.049 s 1.42 2.59 70 70 99 181 26 26 37 67 F 22A-tpm 1,180 s 34.22 0.00 70 7 240 0 26 4 137 O 6 c)AED excursion -75 7 Envelope loss/gain 723 400 286 95 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 600 0 Subtotal(lines 6 to 13) 723 loco 286 95 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 723 1000 286 95 15 Duct loads 13% 1% 92 106 13% 11% 37 10 Total room load 815 1106 323 106 Air required(cfm) 37 55 14 5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed _ + wrigF�isoftY Right-Suited Universe!2019 19.0.12 RSU08398 2021-Oct-2611:02:07Page 5 ...RGY\A-MANUAL J\HOMECRETE-INGRAM RES-FTP.rup Calc=MJ8 Front Door faces: W CPA am Right-J®Worksheet Job: ° � Entire House Date: 10-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromaircom 1 Room name MASTER BATH WIC MASTER INT 2 Exposed wall 20.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions Room area 144.0 W 12.0 x 12.0 ft 48.0 ftz 6,0 x 8.0 ft 5 Ty Construction U-value Or HTM Area (ft� Load Area (ft) Load number (Btuh/ftMF) (Btuh/ft� or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A-6ocs 0.111 n 3.22 1.79 90 77 248 138 0 0 0 0 1 D-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 1 D-h2om 0.290 n 8.41 13.69 13 0 109 178 0 0 0 0 13A-6o 0.11 a 3. 1.7 0 0 0 0 0 0 0 0 11 1 D-h2onn m 0.2900 a 8.4141 46.755 0 0 0 0 0 0 0 0 1 D-h2om 0.290 a 8.41 46.75 0 0 0 0 0 0 0 0 1D-h2omd 0.320 a 9.28 14.15 0 0 0 0 0 0 0 0 13A-6ocs 0.111 s 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13.91 0 0 0 0 0 0 0 0 ID-h2om 0.290 s 8.41 13.69 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13.89 0 0 0 0 0 0 0 0 11 DO 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 13A-6ocs 0.111 w 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.41 46.75 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.41 45.13 0 0 0 0 0 0 0 0 1 E-h2fm 0.290 w 8.41 26.87 0 0 0 0 0 0 0 0 11 DO 0.390 w 11.31 11.43 0 0 0 0 0 0 0 0 1213-0bw 0.097 - 2.81 0.88 110 110 309 97 0 0 0 0 11 DO 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 C 1613-19md 0.049 s 1.42 2.59 144 144 205 373 48 48 68 124 F 22A-tpm 1.180 s 34.22 0.00 144 20 684 0 48 0 0 0 6 c)AED excursion -58 -9 Envelope loss/gain 1556 727 68 116 12 a) Infiltration 175 46 0 0 b) Room ventilation 0 0 0 0 13 lntemal gains: Occupants C 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1730 774 68 116 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1730 774 58 116 15 Duct loads 13°h 11% 221 82 13% 11% 9 12 Total room load 1951 855 77 128 Air required(cfm) 87 43L 3 6 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + wrYgtitsoft^ACA Right-Bute® 2021-Oct-2611:02:07 Universal 2019 19.0.12 RSU08398 Page 6 ...RGY1A-MANUAL JIHOMECRETE-INGRAM RES-FTP.rup Calc=MJ8 Front Door faces: W 1 Right-J® Worksheet Job: Entire Mouse Date: 10-2021 ._.• Lindstrom Air Conditioning By: t-INDSTROPA 3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone: 954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name WIC MASTER EXT MASTER SUITE 2 Exposed wall 8.0 ft 31.0 ft 3 Room height 10.0 ft heaticool 10.0 ft heat/cool 4 Room dimensions 8.0 x 6.0 ft 15.0 x 20.0 ft 5 Room area 48.0 ft' 300.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/ftz-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh Heat Cool Gross NIP/S Heat Cool Gross N/PIS Heat Cool 6 U 13A-6ocs 0.111 n 3.22 1.79 80 80 258 143 160 128 412 229 1 D-h2om 0.290 n 8.41 13.69 0 0 0 0 32 0 269 438 1 D-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 13A-6ocs 0.111 e 3.22 1.79 0 0 0 0 150 118 380 211 11 1 D-h2om 0.290 e 8.41 46.75 0 0 0 0 0 0 0 0 1 D-h2om 0.290 a 8.41 46.75 0 0 0 0 32 0 269 1496 1 D-h2omd 0.320 e 9.28 14.15 0 0 0 0 0 0 0 0 13A-6ocs 0.111 s 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13,91 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13.69 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13.69 0 0 0 0 0 0 0 0 11D0 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 LN 13A-6ocs 0.111 w 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.41 46.75 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.41 45.13 0 0 0 0 0 0 0 0 1 E-h2fm 0,290 w 8.41 26.87 0 0 0 0 0 0 0 0 11 DO 0.390 w 11.31 11.43 0 0 0 0 0 0 0 0 12B-Obw 0,097 - 2.81 0.88 0 0 0 0 0 0 0 0 11 DO 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 C 16B-19md 0.049 s 1.42 2.59 48 48 68 124 300 300 426 776 F 22A-tpm 1.180 s 34.22 0.00 48 8 274 0 300 31 1061 0 6 c)AED excursion -21 -214 Envelope loss/gain 599 246 2817 2935 12 a) Infiltration 155 41 602 160 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 755 287 3419 3555 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 O 0 0 14 Subtotal 755 287 3419 3555 15 Duct loads 13% 11% 96 30 1390 11% 436 376 Total room load 851 317 3855 3931 Air required(cfm) 38 16 173 197 E� Calculations approved by ACCA to meet all requirements of Manual J 8th Ed 444- 2021-Oct-26 11:02:07 ^^ -'�CK Right-Suite®Universal 2019 19.0.12 RSU08398 Page 7 ...RGY1A-MANUAL AHOMECRETE-INGRAM RES-FTP.rup Calc=MJ8 Front Door faces. W Right-J® Worksheet Job: Entire House Date: 10-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH,FL 33069 Phone: 954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com 1 Room name BEDROOM 4 CABANA BATH 2 Exposed wall 19.5 ft 18.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 12.0 x 11.5 ft 6.0 x 6.0 ft 5 Room area 138.0 ftz 36.0 ft2 Ty Construction U-value Or HTM Area (ft) Load Area (w) Load number (Btuh/ft?°F) (atUNW) or perimeter (ft) (8tuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-6ocs 0.111 n 3.22 1.79 0 0 0 0 60 60 193 107 1 D-h2om 0.290 n 8,41 13.69 0 0 0 0 0 0 0 0 1 D-h2om 0.290 n 8.41 13.69 0 0 0 0 0 0 0 0 13A-6ocs 0.111 e 3.22 1.79 80 80 258 143 0 0 0 0 1 1 1 D-h2om 0.290 e 8.41 46.75 0 0 0 0 0 0 0 0 ID-h2om 0,290 a 8.41 46.75 0 0 0 0 0 0 0 0 1 D-h2omd 0.320 a 9.28 14.15 0 0 0 0 0 0 0 0 13A-60cs 0.111 S 3.22 1.79 115 99 319 177 60 38 122 68 1 D-h2om 0.290 s 8.41 13.91 16 14 135 223 0 0 0 0 1 D-h2om 0.290 s 8.41 13.69 0 0 0 0 0 0 0 0 1 D-h2om 0.290 s 8.41 13,69 0 0 0 0 0 0 0 0 11DO 0.390 s 11.31 11.43 0 0 0 0 22 22 249 251 W 13A-6ocs 0,111 w 3.22 1.79 0 0 0 0 60 60 193 107 1 D-h2om 0.290 w 8.41 46.75 0 0 0 0 0 0 0 0 1 D-h2om 0.290 w 8.41 45.13 0 0 0 0 0 0 0 0 1E-h2fm 0.290 w 8.41 26.87 0 0 0 0 0 0 0 0 11 DO 0,390 w 11.31 11.43 0 0 0 0 0 0 0 0 12B-Obw 0.097 - 2.81 0.88 0 0 0 0 0 0 0 0 D 11 DO 0.390 s 11.31 11.43 0 0 0 0 0 0 0 0 C 16B-19md 0.049 s 1.42 2.59 136 138 196 357 36 36 51 93 F 22A-tpm 1.180 s 34.22 0.00 138 20 667 0 36 18 616 0 6 c)AED excursion -67 -50 Envelope loss/gain 1574 832 1425 577 12 a) Infiltration 378 100 349 93 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 23C 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1953 1163 1774 670 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1953 1163 1774 670 15 Duct loads 13% 11% 249 i23 13% 1111. 226 71 Total room load 2202 1285 2000 740 Air required(cfm) 99 64 901 37 _ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - + wricpF�tsoR> 2021-Oct-2611:02:07 14� -�• Right-Suite®Universal 2019 19.0.12 RSU08398 Page 8 ..RGY\A-MANUAL J\HOMECRETE-INGRAM RES-FTP.rup Calc=MJ8 Front Door faces: W