Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSProperty Information Owner:Richard or Barbara Schukraft Address:8514 Belfry Pl Port St Lucie, FL 34986 Building Information Wind Zone:170 MPH. Exposure Category:C Minimum Building Dimension:40 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 64 80 7 34.7 -37.9 2 Int 63 23 7 37.8 -41.0 3 Int 37 81 7 36.0 -39.2 4 Int 35 81 7 36.1 -39.3 5 Int 35 71 7 36.5 -39.7 6 Int 35 71 7 36.5 -39.7 7 Int 35 71 7 36.5 -39.7 8 Int 219 95 7 31.2 -34.4 9 Int 51 71 7 35.5 -38.7 10 Int 25 49 7 37.8 -41.0 11 Int 36 65 7 36.6 -39.8 12 Int 36 65 7 36.6 -39.8 13 Int 35 81 7 36.1 -39.3 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1