Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 1-9-18At FQRM R405-2017 I ' 0 n(9 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KAUFMAN RENOVATION Builder Name: RUBIN CUSTOM HOMES Street: 1491 NORTHWEST WILD OLIVE CT. Permit Office: ST. LUCIE COUNTY JA N r p 2018 City, State, Zip: PALM CITY, FL, Permit Number: Owner: JOHN KAUFMAN Jurisdiction: ST, woo oo 6®unty, Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Permittin one 1. New construction or existing Addition 9. Wall Types (4466.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 4466.50 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedroornoedrms In Addition) 0(0) d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (4573.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 4573.00 ft2 6. Conditioned floor area above grade (W) 4573 b. NIA R= ft2 Conditioned floor area below grade (w) 0 c. R= ft2 Duct 11. Duucts R ft2 7. Windows(533.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 125 a. U-Factor. Dbl, U=0.65 287.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 100 SHGC: SHGC=0.30 c.. Sup: Attic, Ret: Attic, AH: Attic 6 100 b. U-Factor. Dbl, U=0.65 192.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.35 a. Central Unit 48.0 SEER:14.50 c. U-Factor: Dbl, U=0.65 27.00 ftz b. Central Unit 2 additional cooling systems 23.6 SEER:14.50 (see details) SHGC: SHGC=0:25 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see. details) 27.00 ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 2.006 ft. 2 additional heating systems (see details) Area Weighted Average SHGC: 0.313 14. Hot water systems - None required $. Floor Types (4572.5 sqft.) Insulation Area a. Cap: N/A a. Slab -On -Grade Edge Insulation R=0.0 4572.50 ft2 b. Conservation features EF: 4.54086E009 b. N/A R= ft2 c. N/A R= ft2 15. Credits CF, Pstat GlasslFloorArea: 0.117 Total Proposed Modified Loads: 128.65 PASS: Total Baseline Loads: 129.74 I hereby certify that the plans and specifications covered by Review of the plans and �TtiE Srg?, this calculation are in compliance with the Florida Energy specifications covered by this 1,0 ' 0�, Code, calculation indicates compliance ,_ ` with the Florida Energy Code. N nr,,,.; -.•�;���,� Ot� PREPARE BY' Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 * ° I hereby certify that this building, as deWed, ed, is in compliance Florida Statutes. with the Florida Energy Code. G'OD WE �v OWNER/AQNT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation', nspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope.lealkage no greater than 7.00 ACH50 (R402.4.1.2). ST. LU E()UNT4' BUILD! �IO'ICTf1V P.l✓WENiTO FOR j.VN, CE "VIENN'EB BY _,)&4flux 1/9/201 X;tAM r auge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 ITT rIiIST RE KEPT ON JOB 0R.N1a YINSPECTION NVIL , BE «�E' File COPY r-^MRA MAAG n^A'7 PROJECT Title: KAUFMAN RENOVATION Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 4573 Lot # Owner Name: JOHN KAUFMAN Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: RUBIN CUSTOM HOMES Rotate Angle: 0 Street: 1491 NORTHWEST WI Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: PALM CITY, Family Type: Single-family FL, New/Existing: Addition Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS 'Number Name Area Volume 1 UNIT 1 1920 10432 2 UNIT 2 1107 15498 3 UNIT #3 774 6966 4 MINI SPLIT 772 6948 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MINI SPLIT 772 6948 No 0 1 Yes Yes Yes 2 EXT. UNIT 3 774 6966 No 2 1 Yes Yes Yes 3 EXT. UNIT 1 1920 18432 No 2 1 Yes Yes Yes 4 EXT. UNIT 2 1107 15498 No 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value, Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MINI SPLIT 82 ft 0 772 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio EXT. UNIT 3 63 ft 0 774 ft2 0 1 0 3 Slab -On -Grade Edge Insulatio EXT. UNIT 1 101 ft 0 1920 ft2 0 1 0 4 Slab -On -Grade Edge Insulatio EXT. UNIT 2 131.3 ft 0. 1106.5 ft2 0 1' 0 _ - ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel the 4819 ft2 0 ft; Light 0.6 No 0.9 No 0 18.4 ATTIC IRCC V # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Vented 300 4573 ft2 Y N 1/9/2018 10:11 AM EnergyGauge® USA - F1aRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area. Framing Frac Truss Type 1 Under Attic (Vented) MINI SPLIT 30 Blown 772 ftz 0.1 Wood 2 Under Attic (Vented) EXT. UNIT 3 30 Blown 774 ft2 0.1 Wood 3 Under Attic (Vented) EXT. UNIT 1 30 Blown 1920 ft2 0.1 Wood 4 Under Attic (Vented) EXT. UNIT 2 30 Blown 1107 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below a Ornt 10 MIMI TypeSpace 1 NE Exterior Concrete Block - Ext InsMINI SPLIT 4.1 34 0 9 0 .306.0 ft2 0 0 0.5 0 _ 2 SE Exterior Concrete Block - Ext InsMINI SPLIT 4.1 28 0 9 0 252.0 ft2 0 0 0.5 0 -3 NW Exterior Concrete Block - Ext InsMINI SPLIT 4.1 20 0 9 0 180.0 ft2 0 0 0.5 0 4 SE Exterior Concrete Block - Ext InsElKT. UNIT 3 4.1 48 0 9 0 432.0 ft2 0 0 0.5 0 5 SW Exterior Concrete Block - Ext InsEKT. UNIT 3 4.1 15 0 9 0 135.0 ft2 0 0 -6 NE Exterior Concrete Block - Ext InsruXT. UNIT 1 4.1 34 9 9 7 333.0 ft2 0 0 6.5 0 7 SE Exterior Concrete Block - Ext InsEIKT. UNIT 1 4.1 8 5 9 7 80.7 ft2 0 0 0.5 0 8 SW Exterior Concrete Block - Ext InsEXT. UNIT 1 4.1 55 4 9 7 530.3 ft2 0 0 0.5 0 -9 NW Exterior Concrete Block - Ext InsEXT. UNIT 1 4.1 39 5 9 7 377.7 ft2 0 0 0.5 0 10 N Exterior Concrete Block - Ext InsEXT. UNIT 2 4.1 1 5 14 0 19.8 ft2 0 0 0.5 0 11 NE Exterior Concrete Block - Ext InsEXT. UNIT 2 4.1 32 0 14 0 448.0 ft2 0 0 0.5 0 12 SE Exterior Concrete Block - bd Ins0KT. UNIT 2 4.1 23 0 14 0 322.0 ft2 0 0 0.5 0 13 SW Exterior Concrete Block -.Ext InsEXT. UNIT 2 4.1 30 0 14 0 420.0 ft2 0 0 0.5 0 14 NW Exterior Concrete Block - Ext InsEKT.. UNIT 2 4.1 45. 0 14 0 630.0 ft2 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated MINI SPLIT None .46 26 8 208 ft2 2 NE Insulated EXT. UNIT 1 None .39 6 8 48 ft2 WINDOWS Orientation shown is the entered,. Proosed orientation. / Wall Overhang 1/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 2 Metal Low-E Double Yes 0.65 0.3 N 32.0 ft2 2 ft 0 in 1 ft 41n None None 2 SE 4 Metal Low-E Double Yes 0.65 0.3 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 3 SE 4 Metal Low-E Double Yes 0.65 0.3 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 4 NE 6 Metal Low E Double Yes 0.65 0.3 N 27.0 ft2 2 ft 0 in 1 ft 4 in None None 5 SE 7 Metal Low-E Double Yes 0.65 0.3 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 6 SW 8 Metal Low-E Double Yes 0.65 0.3 N 4.0 ft2 2 ft 0 in 1 ft 4 in None None 7 SW 8 Metal Low-E Double Yes 0.65 0.3 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 8 SW 8 Metal Low-E Double Yes 0.65 0.3 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 9 SW 8 Metal Low-E Double Yes 0.65 0.35 N 96.0 ft2 2 ft 0 in 1 ft 4 in None None 10 SW 8 Metal Low-E Double Yes 0.65 0.3 N 34.0 ft2 2 ft 0 in 1 ft 4 in None None 11 SW 8 Metal Low-E Double Yes 0.65 0.3 N 27.0 ft2 2 ft 0 in 1 ft 4 In None None. 12 NW 9 Metal Low-E Double Yes .0.65 0.3 N 6.0 ft2 2 ft 0 in 1 ft 4 In None None 1/9/201810:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FC1Rf1h PAnr,_7n17 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame_ Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 13 NW 9 Metal Low-E Double Yes 0.65 0.3 N 9.0 ft2 2 ft 0 in 1 ft.4 in None None 14 NE 11 Metal Low-E Double Yes 0.65 0.3 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 15 NE 11 Metal Low-E Double Yes 0.65 0.3 N 32.0 ft2 2 ft 0 in 1 ft 4 in None None 16 SW 13 Metal Low-E Double Yes 0.65 0.35 N 96.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1 17 Skylt Metal Low-E Double Yes 0.65 0.3 N 54.0 ft2 0 ft 0 in 0 ft 0 in None None 18 NE 6 Metal Low-E Double Yes 0.65 0.25 N 27.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds. None 19 NW 9 Metal Double (Tinted) Yes 0.65 0.25 N 27.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None .INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse. Proposed ACH(50) .000465 5581.8 306.43 576.29 .3397 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Existing/co None COP:1 34 kBtulhr 1 sys#1 2 Electric Strip Heat/Existing/co None COP:1 17 kBtu/hr 2 sys#2 3 Electric Strip Heat/Existing/co None COP:1 17 kBtu/hr 3 sys#3 4 Electric Heat Pump/Suppleme Split HSPF:11.2 18 kBtu/hr 4 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Untt/Existing/confirme Split SEER: 14.5 48 kBtu/hr cfm 0.8 1 sys#1 2 Central Unit/Existing/confirme Split SEER: 14.5 23.6. kBtu/hr cfm 0.8 2 sys#2 3 Central Unit/None (Baseline a Split SEER: 13 17 kBtu/hr cfm 0.8 3 sys#3 4 Central Unit/Suppiemental for Split SEER: 20.5 18 kBtu/hr cfm 0.a 4 Ductless SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF ftz DUCTS - Supply - --=- Return -- Air CFM 25 CFM25 HVAC # V # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Neat Cool 1 Attic 6 12.5 ft2 Attic 45 ft2 Default Leakage Attic (Default) (Default) 1 1 2 Attic 6 100 ft2 Attic 45 ft2 Default Leakage Attic (Default) (Default) 2 2 3 Attic 6 100 ft2 Attic 45 ft2 Default Leakage Attic _ (Default) (Default) 3 3 1/9/201810:11 AM EnergyGauge® USA FlaRes2017 Section R405.4.1 Compliant Software , Page 4 of 5 TEMPERATURES Programable Thermostat: Y Ceiling Fans: -Coolin Venting Jan Jan Feb Feb Mar Mar Apr Apr Ma May rl n Jun n Jul Jul Aug Aug rl Sep Sep �X� Oct H Nov Nov J� Dec Dec Thermostat Schedule: HERS 2006 Reference 'Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (VVD) AM 78 78 78 78 78 78 78 78 80 80 80, 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (1NEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1f91201810:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 '2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITEkfA' TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: KAUFMAN RENOVATION Builder Name: RUBIN CUSTOM HOMES Street: 1491 NORTHWEST WILD OLIVE CT. Permit Office: ST. LUCIE COUNTY City, State, Zip: PALM CITY, FL, Permit Number. Owner: JOHN KAUFMAN Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceilinglattic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors'to unconditioned attic spaces shall be sealed. _ The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls Walls The junction of the.top plate and the -top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having. a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists�shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing _members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attachedto the crawispace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal 'envelope Recessed light fixtures installed in the building shall be sealed to the -drywall. thermal envelope shall be airtight and IC rated. -Plumbing and wiring Batt insulation shall.be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. ElectdcaVphone box or The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I between fire snrinkler covermlates and wills or ceilings, a. in aaamon, inspection or iog wars snap oe in accordance warn ineprovisions.vr wt,.-wvu. 1/9/2018 10:11 AM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1