HomeMy WebLinkAboutEnergy Efficiency Code 1-9-18At FQRM R405-2017 I ' 0 n(9
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KAUFMAN RENOVATION
Builder Name: RUBIN CUSTOM HOMES
Street: 1491 NORTHWEST WILD OLIVE CT.
Permit Office: ST. LUCIE COUNTY
JA N r p 2018
City, State, Zip: PALM CITY, FL,
Permit Number:
Owner: JOHN KAUFMAN
Jurisdiction:
ST, woo oo 6®unty,
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate
Permittin
one
1. New construction or existing Addition
9. Wall Types (4466.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 4466.50 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedroornoedrms In Addition) 0(0)
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (4573.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 4573.00 ft2
6. Conditioned floor area above grade (W) 4573
b. NIA
R= ft2
Conditioned floor area below grade (w) 0
c.
R= ft2
Duct
11. Duucts
R ft2
7. Windows(533.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 125
a. U-Factor. Dbl, U=0.65 287.00 ft2
b. Sup: Attic, Ret: Attic, AH: Attic
6 100
SHGC: SHGC=0.30
c.. Sup: Attic, Ret: Attic, AH: Attic
6 100
b. U-Factor. Dbl, U=0.65 192.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.35
a. Central Unit
48.0 SEER:14.50
c. U-Factor: Dbl, U=0.65 27.00 ftz
b. Central Unit
2 additional cooling systems
23.6 SEER:14.50
(see details)
SHGC: SHGC=0:25
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see. details) 27.00 ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC: other (see details)
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 2.006 ft.
2 additional heating systems
(see details)
Area Weighted Average SHGC: 0.313
14. Hot water systems - None required
$. Floor Types (4572.5 sqft.) Insulation Area
a.
Cap: N/A
a. Slab -On -Grade Edge Insulation R=0.0 4572.50 ft2
b. Conservation features
EF: 4.54086E009
b. N/A R= ft2
c. N/A R= ft2
15. Credits
CF, Pstat
GlasslFloorArea: 0.117 Total Proposed Modified Loads: 128.65
PASS:
Total Baseline Loads: 129.74
I hereby certify that the plans and specifications covered by
Review of the plans and
�TtiE Srg?,
this calculation are in compliance with the Florida Energy
specifications covered by this
1,0 ' 0�,
Code,
calculation indicates compliance
,_ `
with the Florida Energy Code.
N nr,,,.; -.•�;���,� Ot�
PREPARE BY'
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
* °
I hereby certify that this building, as deWed, ed, is in compliance
Florida Statutes.
with the Florida Energy Code.
G'OD WE �v
OWNER/AQNT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation',
nspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope.lealkage no greater than 7.00 ACH50 (R402.4.1.2).
ST. LU E()UNT4' BUILD! �IO'ICTf1V
P.l✓WENiTO FOR j.VN, CE
"VIENN'EB BY _,)&4flux
1/9/201 X;tAM r auge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
ITT rIiIST RE KEPT ON JOB
0R.N1a YINSPECTION NVIL , BE «�E' File COPY
r-^MRA MAAG n^A'7
PROJECT
Title:
KAUFMAN RENOVATION
Bedrooms: 0
Address Type:
Street Address
Building Type:
User
Conditioned Area: 4573
Lot #
Owner Name:
JOHN KAUFMAN
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
RUBIN CUSTOM HOMES
Rotate Angle: 0
Street:
1491 NORTHWEST WI
Permit Office:
ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
PALM CITY,
Family Type:
Single-family
FL,
New/Existing:
Addition
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
Design
Location TMY Site
97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
'Number
Name Area
Volume
1
UNIT 1 1920
10432
2
UNIT 2 1107
15498
3
UNIT #3 774
6966
4
MINI SPLIT 772
6948
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
MINI SPLIT 772
6948 No 0
1 Yes
Yes
Yes
2
EXT. UNIT 3 774
6966 No 2
1 Yes
Yes
Yes
3
EXT. UNIT 1 1920
18432 No 2
1 Yes
Yes
Yes
4
EXT. UNIT 2 1107
15498 No 1
1 Yes
Yes
Yes
FLOORS
#
Floor Type Space
Perimeter Perimeter R-Value,
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MINI SPLIT 82 ft 0
772 ft2
____
0 1
0
2 Slab -On -Grade Edge Insulatio EXT. UNIT 3 63 ft 0
774 ft2
0 1
0
3 Slab -On -Grade Edge Insulatio EXT. UNIT 1 101 ft 0
1920 ft2
0 1
0
4 Slab -On -Grade Edge Insulatio EXT. UNIT 2 131.3 ft 0.
1106.5 ft2
0 1'
0
_
-
ROOF
Roof Gable Roof
Solar
SA Emitt Emitt Deck Pitch
#
Type Materials
Area Area Color
Absor.
Tested
Tested Insul. (deg)
1
Hip Barrel the
4819 ft2 0 ft; Light
0.6
No 0.9
No 0
18.4
ATTIC
IRCC
V #
Type Ventilation Vent Ratio (1 in)
Area
RBS
1
Full attic Vented 300 4573 ft2
Y N
1/9/2018 10:11 AM EnergyGauge® USA - F1aRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area.
Framing Frac Truss Type
1
Under Attic (Vented) MINI SPLIT
30
Blown
772 ftz
0.1
Wood
2
Under Attic (Vented) EXT. UNIT 3
30
Blown
774 ft2
0.1
Wood
3
Under Attic (Vented) EXT. UNIT 1
30
Blown
1920 ft2
0.1
Wood
4
Under Attic (Vented) EXT. UNIT 2
30
Blown
1107 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing Solar Below
a
Ornt
10
MIMI TypeSpace
1
NE
Exterior
Concrete Block - Ext InsMINI SPLIT
4.1
34
0 9
0
.306.0 ft2
0
0 0.5
0
_ 2
SE
Exterior
Concrete Block - Ext InsMINI SPLIT
4.1
28
0 9
0
252.0 ft2
0
0 0.5
0
-3
NW
Exterior
Concrete Block - Ext InsMINI SPLIT
4.1
20
0 9
0
180.0 ft2
0
0 0.5
0
4
SE
Exterior
Concrete Block - Ext InsElKT. UNIT 3
4.1
48
0 9
0
432.0 ft2
0
0 0.5
0
5
SW
Exterior
Concrete Block - Ext InsEKT. UNIT 3
4.1
15
0 9
0
135.0 ft2
0
0
-6
NE
Exterior
Concrete Block - Ext InsruXT. UNIT 1
4.1
34
9 9
7
333.0 ft2
0
0 6.5
0
7
SE
Exterior
Concrete Block - Ext InsEIKT. UNIT 1
4.1
8
5 9
7
80.7 ft2
0
0 0.5
0
8
SW
Exterior
Concrete Block - Ext InsEXT. UNIT 1
4.1
55
4 9
7
530.3 ft2
0
0 0.5
0
-9
NW
Exterior
Concrete Block - Ext InsEXT. UNIT 1
4.1
39
5 9
7
377.7 ft2
0
0 0.5
0
10
N
Exterior
Concrete Block - Ext InsEXT. UNIT 2
4.1
1
5 14
0
19.8 ft2
0
0 0.5
0
11
NE
Exterior
Concrete Block - Ext InsEXT. UNIT 2
4.1
32
0 14
0
448.0 ft2
0
0 0.5
0
12
SE
Exterior
Concrete Block - bd Ins0KT. UNIT 2
4.1
23
0 14
0
322.0 ft2
0
0 0.5
0
13
SW
Exterior
Concrete Block -.Ext InsEXT. UNIT 2
4.1
30
0 14
0
420.0 ft2
0
0 0.5
0
14
NW
Exterior
Concrete Block - Ext InsEKT.. UNIT 2
4.1
45.
0 14
0
630.0 ft2
0
0 0.5
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NE
Insulated MINI SPLIT
None
.46
26
8
208 ft2
2
NE
Insulated EXT. UNIT 1
None
.39
6
8
48 ft2
WINDOWS
Orientation shown is the entered,. Proosed orientation.
/
Wall
Overhang
1/
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SE 2
Metal Low-E Double Yes
0.65
0.3
N
32.0 ft2
2 ft 0 in
1 ft 41n
None
None
2
SE 4
Metal Low-E Double Yes
0.65
0.3
N
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
3
SE 4
Metal Low-E Double Yes
0.65
0.3
N
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
NE 6
Metal Low E Double Yes
0.65
0.3
N
27.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
SE 7
Metal Low-E Double Yes
0.65
0.3
N
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
SW 8
Metal Low-E Double Yes
0.65
0.3
N
4.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
SW 8
Metal Low-E Double Yes
0.65
0.3
N
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
8
SW 8
Metal Low-E Double Yes
0.65
0.3
N
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
9
SW 8
Metal Low-E Double Yes
0.65
0.35
N
96.0 ft2
2 ft 0 in
1 ft 4 in
None
None
10
SW 8
Metal Low-E Double Yes
0.65
0.3
N
34.0 ft2
2 ft 0 in
1 ft 4 in
None
None
11
SW 8
Metal Low-E Double Yes
0.65
0.3
N
27.0 ft2
2 ft 0 in
1 ft 4 In
None
None.
12
NW 9
Metal Low-E Double Yes
.0.65
0.3
N
6.0 ft2
2 ft 0 in
1 ft 4 In
None
None
1/9/201810:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FC1Rf1h PAnr,_7n17
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Omt ID Frame_ Panes NFRC
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
13
NW 9 Metal Low-E Double Yes
0.65 0.3 N 9.0 ft2 2 ft 0 in 1 ft.4 in None
None
14
NE 11 Metal Low-E Double Yes
0.65 0.3 N 12.0 ft2 2 ft 0 in 1 ft 4 in None
None
15
NE 11 Metal Low-E Double Yes
0.65 0.3 N 32.0 ft2 2 ft 0 in 1 ft 4 in None
None
16
SW 13 Metal Low-E Double Yes
0.65 0.35 N 96.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds
Exterior 1
17
Skylt Metal Low-E Double Yes
0.65 0.3 N 54.0 ft2 0 ft 0 in 0 ft 0 in None
None
18
NE 6 Metal Low-E Double Yes
0.65 0.25 N 27.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds.
None
19
NW 9 Metal Double (Tinted) Yes
0.65 0.25 N 27.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds
None
.INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse. Proposed ACH(50) .000465
5581.8 306.43 576.29 .3397 7
HEATING SYSTEM
#
System Type Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat/Existing/co None
COP:1 34 kBtulhr 1
sys#1
2
Electric Strip Heat/Existing/co None
COP:1 17 kBtu/hr 2
sys#2
3
Electric Strip Heat/Existing/co None
COP:1 17 kBtu/hr 3
sys#3
4
Electric Heat Pump/Suppleme Split
HSPF:11.2 18 kBtu/hr 4
Ductless
COOLING SYSTEM
#
System Type Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Untt/Existing/confirme Split
SEER: 14.5 48 kBtu/hr cfm 0.8 1
sys#1
2
Central Unit/Existing/confirme Split
SEER: 14.5 23.6. kBtu/hr cfm 0.8 2
sys#2
3
Central Unit/None (Baseline a Split
SEER: 13 17 kBtu/hr cfm 0.8 3
sys#3
4
Central Unit/Suppiemental for Split
SEER: 20.5 18 kBtu/hr cfm 0.a 4
Ductless
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
ftz
DUCTS
- Supply - --=- Return -- Air CFM 25 CFM25
HVAC #
V #
Location R Value Area Location
Area Leakage Type Handler TOT OUT QN RLF
Neat Cool
1
Attic 6 12.5 ft2 Attic
45 ft2 Default Leakage Attic (Default) (Default)
1 1
2
Attic 6 100 ft2 Attic
45 ft2 Default Leakage Attic (Default) (Default)
2 2
3
Attic 6 100 ft2 Attic
45 ft2 Default Leakage Attic _ (Default) (Default)
3 3
1/9/201810:11 AM EnergyGauge® USA FlaRes2017 Section R405.4.1 Compliant Software , Page 4 of 5
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
-Coolin
Venting
Jan
Jan
Feb
Feb
Mar
Mar
Apr
Apr
Ma
May rl
n
Jun
n Jul
Jul
Aug
Aug
rl
Sep Sep �X�
Oct
H Nov
Nov
J�
Dec
Dec
Thermostat Schedule:
HERS 2006
Reference
'Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (VVD)
AM
78
78
78
78
78
78
78
78
80
80
80,
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (1NEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
1f91201810:11 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
'2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITEkfA'
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: KAUFMAN RENOVATION Builder Name: RUBIN CUSTOM HOMES
Street: 1491 NORTHWEST WILD OLIVE CT. Permit Office: ST. LUCIE COUNTY
City, State, Zip: PALM CITY, FL, Permit Number.
Owner: JOHN KAUFMAN Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceilinglattic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors'to
unconditioned attic spaces shall be sealed. _
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
Walls
The junction of the.top plate and the -top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having. a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists�shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
_members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attachedto the crawispace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
Narrow cavities
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal 'envelope
Recessed light fixtures installed in the building
shall be sealed to the -drywall.
thermal envelope shall be airtight and IC rated.
-Plumbing and wiring
Batt insulation shall.be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
ElectdcaVphone box or
The air barrier shall be installed behind electrical or communication
exteriorwalls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
I between fire snrinkler covermlates and wills or ceilings,
a. in aaamon, inspection or iog wars snap oe in accordance warn ineprovisions.vr wt,.-wvu.
1/9/2018 10:11 AM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1