Loading...
HomeMy WebLinkAboutEnergy Efficiency Code- DISAPPROVEDFORM R405-2017 ,FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KAUFMAN RENOVATION Street: 1491 NORTHWEST WILD OLIVE CT. City, State, Zip: PALM CITY, FL, Owner. JOHN KAUFMAN Design Location: FL, Fort Pierce Builder Name: RUBIN CUSTOM HOMES Permit Office: ST. LUCIE COUNTY Permit Number: Jurisdiction: County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (4466.5 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 4466.50 ft2 3. Number of units, if multiple family 1 b. N/A R= ft2 4. Number of BedroomaBedrms In Addition) 0(0) c. N/A d. WA R= ft2 5. Is this a worst case? No 10. Ceiling Types (4573.0 sqft.) R= ft2 Insulation Area 6. Conditioned floor area above grade ( ftz) 4573 a. Under Attic (Vented) R=30.0 4573.00 ft2 b. N/A R= ftz Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(551.0 sgft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 a. U-Factor: Dbl, U=0.65 305.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 125 6 100 SHGC: SHGC=0.30 c. Sup: Attic, Ret: Attic, AH: Attic 6 100 b. U-Factor: Dbl, U=0.65 192.00 ft2 12. Cooling systems _ kBtu/hr Efficiency SHGC: SHGC=0.35 a. Central Unit 48.0 SEER:14.50 c. U-Factor: Dbl, U=0.65 27.00 ft2 b. Central Unit 23.6 SEER:14.50 SHGC: SHGC=0.25 2 additional cooling systems (see details) d. U-Factor other (see details) 27.00 ft2 g systems 13. Heatina. Electric Strip Heat kBtu/hr Efficiency SHGC: other (see details) Area Weighted Average Overhang Depth: 2.000 ft. b. Electric Strip Heat 2 additional heating systems 34.0 COP:1.00 17.0 COPA.00 Area Weighted Average SHGC: 0.313 14. Hot water systems - None required (see details) 8. Floor Types (4572.5 sgft.) Insulation Area a. Cap: N/A a. Slab -On -Grade Edge Insulation R=0.0 4572.50 ft2 EF: 0.000 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, Pstat Glass/Floor Area: 0.120 Total Proposed Modified Loads: 129.06 PASS Total Baseline Loads: 128.69 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance PREPARE BY with the Florida Energy Code. DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AG NT: DATE: I I BUILDING OFFICIAL: DATE: P%. - Compliance requires certification by the air handler unit manufacturer that waitI P4GI' certified factory -sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance wit envelope leakage test report with envelope leakage no greater than 7.00 AC H50 (R402.4.1 it 1/8/2018 8:58 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software qualifies as his project requires -an Page 1 of 5 FORM R4ns-gn17 _ PROJECT Title: KAUFMAN RENOVATION Bedrooms: 0 Building Type: User Address Type: Street Address Owner Name: JOHN KAUFMAN Conditioned Area: 4573 Total Stories: 1 Lot # # of Units: 1 Block/Subdivision: Worst Case: No Builder Name: RUSIN CUSTOM HOMES Rotate Angle: 0 PlatBook: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No Street: 'County: 1491 NORTHWEST WI Jurisdiction: Family Type: Single-family Whole. House Fan: No City, State, Zip: St. Lucie PALM CITY, New/Existing: Addition FL , Comment: CLIMATE Design Location Design Temp TMY Site Int Design Temp Heating Design Daily Temp 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 UNIT 1 1920 18432 2 UNIT 2 1107 15498 3 UNIT#3 774 6966 4 MINI SPLIT 772 6948 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID' Finished Cooled Heated 1 MINI SPLIT 772 6948 No 0 1 Yes Yes Yes 2 EXT. UNIT 3 774 6966 No 2 1 Yes Yes Yes 3 EXT. UNIT 1 1920 18432 No 2 1 Yes Yes Yes 4 EXT. UNIT 2 1107 15498 No 1 1 Yes Yes Yes FLOORS Floor Type Space Perimeter Perimeter R-Value ' Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MINI SPLIT 82 ft 0 772 ft2 0 1 0 2 Slab -On -Grade Edge Insulatio EXT. UNIT 3 63 ft 0 '774 ft2 0 1 0 3Slab-On-Grade Edge Insulatio EXT. UNIT 101 ft 0 1920 ft2 0 1 0 4 Slab -On -Grade Edge Insulatio EXT. UNIT 2 131.3 ft 0 1106.5 ft2 0 1 0 ROOF # Type Materials Roof Gable Roof Area Solar SA Emitt Emltt Deck Pitch Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel the 4819 ft2 0 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 4573 ft2 Y N 1/8/2018 8:58 AM EnergyGaugeO USA - Fla.ReS2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 • CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MINI SPLIT 30 Blown 772 ft2 0.1 Wood 2 Under Attic (Vented) EXT. UNIT 3 30 Blown 774 ftz 0.1 Wood 3 Under Attic (Vented) EXT. UNIT 1 30 Blown 1920 ft2 0.1 Wood 4 Under Attic (Vented) EXT. UNIT 2 30 Blown 1107 ft2 0.1 Wood WALLS Adjacent Space --If ypp_ Cavity Width Height Sheathing Framing Solar Below 1 NE Exterior Concrete Block - Ext InstMINI SPLIT 4.1 34 0 9 0 306.0 ft2 0 0 0.5 0 2 SE Exterior Concrete Block - Ext InsllI+IINI SPLIT 4.1 28 0 9 0 252.0 ft2 0 0 0.5 0 -3 NW Exterior Concrete Block - Ext InstMINI SPLIT 4.1 20 0 9 0 180.0 ft2 0 0 0.5 0 4 SE Exterior Concrete Block - Ext Ins8DCT. UNIT 3 4.1 .48 0 9 0 432.0 ft2 0 0 0:5 0 5 SW Exterior Concrete Block - Ext InsEXT. UNIT 3 4.1 15 0 9 0 135.0 ft2 0 0 0.5 0 6 NE Exterior Concrete Block - Ext IhsECT. UNIT 1 4.1 34 9 9 7 333.0 ft2 0 0 0.5 0 -7 SE, Exterior Concrete Block - Ext InsEXT. UNIT 1 4.1 8 5 9 7 80.7 ft2 0 .0 0.5 0 -8 SW Exterior Concrete Block - Ext InsEXT. UNIT 1 4.1 55 4 9 7 590.3 ft2 0 0 0.5 0 -9 NW Exterior Concrete Block - Ext InsEXT. UNIT 1 4.1 39 5 9 7 377.7 ft2 0 0 0.5 0 10 N Exterior Concrete Block - Ext InsEiXT. UNIT 2 4.1 1 5 14 0 19.8 ft2 0 0 0.5 0 _ 11 NE Exterior Concrete Block - Ext InsEiXT. UNIT 2 4.1 32 0 14 0 448.0 ft2 0 0 0.5 0 _ 12 SE Exterior Concrete Block - Ext InsEXT. UNIT 2 4.1 23 0 14 0 322.0 ft2 0 0 0.5 0 _ 13 SW Exterior Concrete Block - Ext InsEXT. UNIT 2 4.1 30 0 14 0 420.0 ft2 0 0 0.5 0 _14 NW Exterior Concrete Block- Ext InsEiXT. UNIT.2 4.1 45 0 14 0 630.0 ft2 0 0 0.5 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated MINI SPLIT None .46 26 8 208 ft2 2 NE Insulated EXT. UNIT 1 None .39 6 8 48 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 2 Metal Low-E Double Yes 0.65 0.3 N 32.0 ft2 2 ft 0 in 1 ft4 in None None 2 SE 4 Metal Low-E Double Yes 0.66 0.3 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 3 SE 4 Metal Low-E Double Yes 0.65 0.3 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 4 NE 6 Metal Low-E Double Yes 0.65 0.3 N 27.0 ft2 ft 0 in 1 ft 4 in None None 5 SE 7 Metal Low-E Double Yes 0.65 0.3 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 6 SW 8 Metal Low-E Double Yes 0.65 0.3 N 4.0 ft2 2 ft 0 in 1 ft 4 in None None 7 SW 8 Metal Low-E Double Yes 0.65 0.3 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 8 SW 8 Metal Low-E Double Yes 0.65 0.3 N 9.0 ft2 2 ft 0 in 7 ft 0 in None None 9 SW 8 Metal Low-E Double Yes 0.65 0.35 N 96.0 ft2 ft 0 in 1 ft 4 in None None 10 SW 8 Metal Low-E Double Yes 0.65 0.3 N 34.0 ft2 2 ft 0 in 1 ft 4 in None None 11 SW 8 Metal Low-E Double Yes 0.65 0.3 N 27.0 ft2 2 ft 0 in 1 ft 4 in None None 12 NW 9 Metal Low-E Double Yes 0.65 0.3 N 6.0 ft2 2 ft 0 in 7 ft 0 in None None 1/8/2018 8:58 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 WINDOWS i venation shown, is the entered, Proposed orientation. /• 1/ Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening g 13 NW 9 Metal Low-E Double Yes 0.65 0.3 N 9.0 ft2 2 ft 0 in 1 ft4 in None None 14 NE 11 Metal Low-E Double Yes 0.65 0.3 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 15 NE 11 Metal Low-E Double Yes 0.65 0.3 N 32.0 ft2 2 ft 0 in 1 ft 4 in None None 16 SW 13 Metal Low-E Double Yes 0.65 0.35 N 96.0 ft2 2 ft 0 In 1 ft 4 in Drapes/blinds Exterior 1 17 Skylt Metal Low-E Double Yes 0.65 0.3 N 72.0 ft2 0 ft 0 in 0 ft 0 in None None 18 NE 6 Metal Low-E Double Yes 0.65 0.25 N 27.0 111:2 2 ft 0 in 1 ft 4 in Drapes/blinds None 19 NW 9 Metal Double (Tinted) Yes 0.65 0.25 N 27.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000465 5581.8 306.43 576:29 .3397 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Existing/co None COPA 34 kBtu/hr 1 sys#1 2 Electric Strip Heat/Existing/co None COPA 17 kBtu/hr 2 sys#2 3 Electric Strip Heat/Existing/co None CODA 17 kBtulhr 3 sys#3 4 Electric Heat Pump/Suppleme Split HSPF:11.2 18 kBtu/hr 4 Ductless COOLING SYSTEM # System Type Subtype Efficiency ..Capacity Air Flow SHR Block Ducts 1 Central Unit/Existing/confirme Split SEER: 14.5 48 kBtu/hr cfm 0.7 1 sys#1 2 Central Unit/Existing/confirme Split SEER: 14.5 23.6 kBtu/hr cfm 0.7 2 sys#2 3 Central Unit/Existing/confirme Split SEER: 13 17 kBtu/hr cfm 0.7 3 sys#3 4 Central Unit/Supplemental for Split SEER:'20.5 18 kBtu/hr cfm 0.7 4 Ductless SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / -Supply - ---- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 125 ft2 Attic 45 ft2 Default Leakage Attic (Default) (Default) 1 1 2 Attic 6 100 ft2 Attic 45 ft2 Default Leakage Attic (Default) (Default) 2 2 3 Attic 6 100 ft2 Attic 45 ft2 Default Leakage Attic (Default) (Default) 3 3 1/8/2018 8:58 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Sofhlare Page 4 of 5 FORM R405-2017 ' TEMPERATURES* Programable Thermostat: Y Ceiling Fans: Cooling Jan Venting Jan Feb Feb Mar Mar Apr Apr ]Mayy Ma Jun Jun Jul Jul Aug Aug Sep Sep Oct IXIOct Nov Dec Dec X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (VVD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 80 80 80 80 Cooling (WEH AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 78 66 78 66 78 66 78 66 78 68 78 78 78 78 78 78 PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 68, 68 68 68 68 68 68 68 68 _ 68 68 68 68 66 66 1/812018 8:58 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: KAUFMAN RENOVATION Builder Name: RUSIN CUSTOM HOMES Street: 1491 NORTHWEST WILD OLIVE CT. Permit Office: ST. LUCIE COUNTY City, State, Zip: PALM CITY, FL, Permit Number. Owner: JOHN KAUFMAN Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable Insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing g cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping; joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts; utility penetrations, and flue shafts opening to .exterior or unconditioned space shall be sealed. Batts in narrow cavities•shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall autAnd behind Dining and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire spronkler cover plates and walls or ceilinas,.. a. ,n auuwull, n iopri mun ur iug waus snau oe in accordance With the provisions of Icc-40u. 1/8/2018 8:58 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY OeAFORMANCE LE Vi L (EPL) DISPLAY CARD ESTIMATED ENERGY" PERFORMANCE INDEX* = 100 The lower the EnergyRerformance Index, the more efficient the home. 149.1 NORTHWEST WILD OLIVE CT., PALM CITY, FL, I. New construction or existing Addition 2. Single family or multiple family Single-family 3. Number of units, if multiple family 1 4. Number of Bedrooms 0(0) 5. Is this a worst case? No 6. Conditioned floor area (ft2) 4573 7. Windows" Description Area a. U-Factor: Dbl, U=0.65 305.00 ft2 SHGC: SHGC=0.30 b. U-Factor. Dbl, U=0.65 192.00 ft2 .SHGC: SHGC=0.35 c. U-Factor: Dbl, U=0.65 27.00 ft2 SHGC: SHGC=0:25 d. U-Factor: other (see details) 27.00,111:2 SHGC: other (see details) Area Weighted. Average Overhang Depth: 2.000 ft. Area Weighted Average- SHGC: 0.313 8. Floor Types Insulation Area a. Slab-On-Grade.Edge Insulation R=0.0 4572.50'f12 b. NIA R= ft2 c. N/A R= ft2 9. Wall Types Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 4466.50 ft2 b. NIA R= ft2 c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 4573.00 ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 ' 125 b. Sup: Attic, Ret: Attic, AH: Attic 6 100 c. Sup: Attic, Ret: Attic, AH: Attic 6 100 12. Cooling systems kBtu/hr Efficiency a. ,Central Unit 48.0 SEER:14.50 b. Central Unit 23.6 SEER:1,4.50 2 additional cooling systems (see details) 13. Heating systems kBtulhr Efficiency a. Electric Strip Heat 34.0 COP:1.00 b. Electric Strip Heat 17.0 COP:1.00 2'additional heating systems (see details) 14. Hot water systems - None required a Cap: N/A EF: b. Conservation features None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EFL Display Card will be completed based on installed Code compliant feakires. Builder Signature: Date: 8 1 FT. Address of New Home:q� \�0C l �� n��V� j� City/FL Zip: 34�' . '.Note: This is not.a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficientmortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the. EnergyGauge web site at energygauge.com for information'and a list of certified Raters. For information about the Florida. Building Code, Energy Conservation; contact the 'Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/8/2018 8:58 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1