HomeMy WebLinkAboutEnergy Efficiency Code.4f
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
EStreet:
ct Name: CURTIS CHANCEY Builder Name: Cole Construction services Uc
9620 Carlton Rd Permit Office: ST LUCIE COUNTY
State, Zip: Port St Lucie, FL , 34987 Permit Number:1711-0274
er: CURTIS CHANCEY Jurisdiction: 611000
Design Location: FL, ST_LUCIE_CO INTL County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or ebsting New (From Plans) 9. Wall Types (2001.7 sqft.) Insulation Area
a. Concrete Block - Int Insult Exterior R=4.0 2001.70 ft2
2. Single family or multiple family Single-family b. NIA R= ft2
3'.*, Number of units, if multiple family 1 c. NIA R= fP
r 5 d. NIA R= �
4l Number of Bedrooms 10. Ceiling Types (2472.0 sgfL) insulation Area
5.. Is this a worst case? No a. Under Attic (Vented) R=30.0 . 2472.00 W
2472 b. N/A R= ft2
6. Conditioned floor area above grade (ft2) c. NIA R= ft2
Conditioned floor area below grade (ft) 0 11. Ducts R ft2
a. Su
7. Windows(220.3 sgft.) Description Area P: Attic, Ret: Attic, AH: Main 6 494A
a. U-Factor: Dbl, U=0.30 180.25 ft2
SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency
b. U-Factor: Dbl, U=0.38 40.00 ft2 a. Central Unit 66.0 SEER:16.00
SHGC: SHGC=0.22
c. U-Factor: N/A ftZ
SHGC: 13. Heating systems kBtumr Efficiency
d. U-Factor: N/A
ft2 a. Electric Strip Heat 34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3•640 ft. 14. Hot water systems
Area Weighted Average SHGC: 0.212 a. Electric Cap: 40 gallons
8. Floor Types (2472.0 sgft.) Insulation Area EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2472.00 ft2 b. Conservation features
b. N/A R= ft2 None
c. N/A
R= fF 15. Credits Pstat
Total Proposed Modified Loads: 72.60 PASS
Glass/Floor Area: 0.089 Total Baseline Loads: 75.90
�KF sr9r
I hereby certify that the plans and specifications covered by Review of the plans and QF�
this calculation are in compliance h the Florida E specifications covered by this.a°r�"
Code. calculation indicates compliance with the Florida Energy Code. t�
PREPARED BY: Before construction is completed ,z
this building will be inspected for 0x
DATE: compliance with Section 553.908
Florida Statutes.
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this
project requires an envelope leakage test report with envelope leakage no greater,than 5.0 ACH50 (R402.4.1 2).^h
WNW- `PEf�111 "r a e 1 of 4
1211212017 2:02 PM EnergyGauge® USA - v5.1- Section R405.4.1 Compliant Software St, Lucle County', F1P 9
FORM R405-2014
PROJECT
Title:
CURTIS CHANCEY
Bedrooms:
5
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2472
Lot #
Owner:
CURTIS CHANCEY
Total Stories:
1
Block/SubDivision:
PlatBook:
SeclTownlRange: 03137
# of Units:
1
Worst Case:
No
0
Street:
9620 Carlton Rd
Builder Name:
Cole Construction Services Lie
Rotate Angle:
County:
St. Lucie
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
City, State, Zip:
Port St Lucie ,
Jurisdiction:
611000
Whole House Fan:
FL, 34987
Family Type:
Single-family
New/E)asting:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
/
V
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter Summer Degree Days
Moisture Range
FL, ST_LUCIE_CO_INTL
Fl-VERO_BEACH_MUNI 2 39 90
70 75
299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blocki
2472 19776
SPACES
Name
Area Volume Kitchen Occupants
Bedrooms Intl ID
Finished
Cooled Heated
Number
1
Main
2472 19776 Yes 6
5 1
Yes
Yes Yes
FLOORS
# Floor Type
YP
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 240 ft 0
2472 fF ----
0 0 1
ROOF
Roof Gable Roof
Solar SA
Emitt
Emitt Deck Pitch
Materials Area Area Color
Absor. Tested
Tested Insul. (deg)
# Type
1 Hip
Composition shingles 2678 ftz 0 fF Medium
0.96 No
0.9
No 0 22.6
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area RBS
IRCC
1 Full attic
Vented 150
i
2472 ft2 N
N
CEILING
V F
7=9
Ceiling Type
Space i R-Value Ins Type Area
Framing Frac Truss Type
1 Under Attic (Vented) Main 30 Blown 2472 ftz
0
Wood
Page 2 of 4
12/12/2017 2:02 PM EnergyGauge® USA v5.1 - Section R405.4.1 Compliant Software
I
FORM R405-2014
r
WALLS
cavity Width Height
ty
Sheathing
Framing Solar
Below
r�r;ktie
Adjacent Space
_
Area
R value
Frac:hnn Ahsor
N
Exterior Concrete Block - Int Insul Main
4 68 4 9
615.0 ftz
0 0.75
0
2 E
Exterior Concrete Block - Int Insul Main
4 31 8
248.0 ftz
0 0.75
0
_
3 E
Exterior Concrete Block - Int Insul Main
4 22 6 8
180.0 ftz
0 0.75
0
_
4 S
Exterior Concrete Block - Int Insul Main
4 68 4 8
546.7 fiz
0 0.75
0
_
5 W
Exterior Concrete Block - Int Insul Main
4 29 6 8
236.0 ftz
0 0.75
0
_
6 W
Exterior Concrete Block - Int Insul Main
4 22 8
176.0 ftz
0 0.75
0
DOORS
#
Omt Door Type Space
Storms U Value Ft
Width
In
Height
Ft In
Area
1
E Insulated Main
None .28
3
6 8
20 ftz
2
W Insulated Main
None 17
3
6 8
20 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
I
Overhang
ff::::�2
Wall
rnt ID Frame Panes NFRC
U-Factor SHGC Area
Depth
Separation
Int Shade
Screening
N 1 Vinyl Low-E Double Yes
; 0.3 0.21 11.4 ftz
2 It 0 in
1 ft0 in
None
None
E 2 Vinyl Low-E Double Yes
0.3 0.21 47.3 IF2
ft 0 in
1 ft0in
None
None
E 3 Vinyl Low-E Double Yes
0.38 0.22 40.0 ftz
8 It 8 in
1 ft0 in
None
None
4
S 4 Vinyl Low-E Double Yes
0.3 0.21 47.3 IF
2 It 0 in
1 ft 0 in
None
None
g
W 5 Vinyl Low-E Double Yes
0.3 0.21 31.5 ftz
2 It 0 in
1 tt 0 in
None
None
6
W 5 Vinyl Low-E Double Yes
0.3 0.21 11.4 ftz
2 it 0 in
1 ft0 in
None
None
7
W 6 Vinyl Low-E Double Yes
0.3 0.21 31.5 ftz
5 It 0 in
1 ft0 in
None
None
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254
1648 90.47 170.15
.1906
5
HEATING SYSTEM
#
Sub a
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat None
COP:1
34 kBtu/hr
1
sys#1
COOLING SYSTEM
_
#
Subtype
System Type Sub a
Efficiency Capacity
Air Flow
SHR Block
. Ducts
None
SEER: 16 56 kBtu/hr 1680
cfm
0.75 1
sys#1
1
Central Unit
12/12/2017 2:02 PM � g Ener Gau e® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 4
FUKM K4U*-LUI4
HOT WATER SYSTEM
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
Electric
None
Main
0.98 40 gal
80 gal
120 deg
None
SOLAR HOT WATER SYSTEM
EC
rF
Collector
Storage
t # Company Name
System Model # Collector Model # Area
Volume
FEF
ne None
ft2
DUCTS
---- Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
# Location R Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 494.4 ft
Attic
123.6 ft Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
He an
Mar
WApr
Apr
May X Jun rl Jul
May Jun Jul
ri Aug
Aug
p
Sep
W Oct
Oct
HNov
N v
Dec
Venting [ Feb
Mar
Thermostat Schedule: HERS 2006 Reference
Hours
9
10
11
12
Schedule Type
1
2
3
4 5 6
7
8
Cooling (WD) AM
78
78
80
78
78
78 78 78
78 78 78
78
78
78
78
80
78
80
78
80
78
80
78
PM
80
Cooling (WEH) PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating(WD)
PM
gg
68
66
68
68 68 68
68
68
68
68
66
68
66
Heating(WEH)
6g
68
68
68 68 68
68
68
68
68
66
66
PM
12/12/2017 2:02 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
y ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD'
ESTIMATED ENERGY. PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home. -
9620 Carlton Rd, Port St Lucie, FL, 34987
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
S. Is this a worst case?
6. Conditioned floor area (W)
7. Windows"
Description
a. U-Factor:
Dbl, U=0.30
SHGC:
SHGC=0.21
b. U-Factor:
Dbl; U=0.38
SHGC:
SHGC=0.22
c. U-Factor:
N/A
SHGC:
d. U-Factor:
NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
New (From Plans)
Single-family
1
5
No
2412
Area
18025 ft2
40.00 ft2
ft2
ft2
3.640 ft.
0.212
8. Floor Types Insulation Area
a. Slab -on -Grade Edge Insulation R=0.0 2472.00 ft2
b. N/A R= ft2
c. N/A R= ft2
9. Wall Types
a. Concrete Block - Int Insul, EXterior
b. N/A
c. N/A
d. N/A
10. Ceiling Types
a. Under Attic (Vented)
b. N/A
.c. NIA
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
Insulation
R=4.0
R=
R=
R=
Insulation
R=30.0
R=
R=
Area
2001.70 fta
ftz
ftz
ftz
Area
2472.00 ft2
ftz
fe
R ft2
6 494.4
kBtu/hr Efficiency
56.0 SEER:16.00
kBtu/hr Efficiency
34.0 COP:1.00
Cap: 40 gallons
EF: 0.98
Pstat
0,
1r aar�lftt�4.
�; 60- M
"Note: This is not a Building Energy Rating. If your Index is below 7.0, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
636-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, .contact the"Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
12/12/2017 2:02 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1