Loading...
HomeMy WebLinkAboutEnergy Efficiency Code.4f FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method EStreet: ct Name: CURTIS CHANCEY Builder Name: Cole Construction services Uc 9620 Carlton Rd Permit Office: ST LUCIE COUNTY State, Zip: Port St Lucie, FL , 34987 Permit Number:1711-0274 er: CURTIS CHANCEY Jurisdiction: 611000 Design Location: FL, ST_LUCIE_CO INTL County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or ebsting New (From Plans) 9. Wall Types (2001.7 sqft.) Insulation Area a. Concrete Block - Int Insult Exterior R=4.0 2001.70 ft2 2. Single family or multiple family Single-family b. NIA R= ft2 3'.*, Number of units, if multiple family 1 c. NIA R= fP r 5 d. NIA R= � 4l Number of Bedrooms 10. Ceiling Types (2472.0 sgfL) insulation Area 5.. Is this a worst case? No a. Under Attic (Vented) R=30.0 . 2472.00 W 2472 b. N/A R= ft2 6. Conditioned floor area above grade (ft2) c. NIA R= ft2 Conditioned floor area below grade (ft) 0 11. Ducts R ft2 a. Su 7. Windows(220.3 sgft.) Description Area P: Attic, Ret: Attic, AH: Main 6 494A a. U-Factor: Dbl, U=0.30 180.25 ft2 SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency b. U-Factor: Dbl, U=0.38 40.00 ft2 a. Central Unit 66.0 SEER:16.00 SHGC: SHGC=0.22 c. U-Factor: N/A ftZ SHGC: 13. Heating systems kBtumr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 3•640 ft. 14. Hot water systems Area Weighted Average SHGC: 0.212 a. Electric Cap: 40 gallons 8. Floor Types (2472.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2472.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= fF 15. Credits Pstat Total Proposed Modified Loads: 72.60 PASS Glass/Floor Area: 0.089 Total Baseline Loads: 75.90 �KF sr9r I hereby certify that the plans and specifications covered by Review of the plans and QF� this calculation are in compliance h the Florida E specifications covered by this.a°r�" Code. calculation indicates compliance with the Florida Energy Code. t� PREPARED BY: Before construction is completed ,z this building will be inspected for 0x DATE: compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test report with envelope leakage no greater,than 5.0 ACH50 (R402.4.1 2).^h WNW- `PEf�111 "r a e 1 of 4 1211212017 2:02 PM EnergyGauge® USA - v5.1- Section R405.4.1 Compliant Software St, Lucle County', F1P 9 FORM R405-2014 PROJECT Title: CURTIS CHANCEY Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2472 Lot # Owner: CURTIS CHANCEY Total Stories: 1 Block/SubDivision: PlatBook: SeclTownlRange: 03137 # of Units: 1 Worst Case: No 0 Street: 9620 Carlton Rd Builder Name: Cole Construction Services Lie Rotate Angle: County: St. Lucie Permit Office: ST LUCIE COUNTY Cross Ventilation: City, State, Zip: Port St Lucie , Jurisdiction: 611000 Whole House Fan: FL, 34987 Family Type: Single-family New/E)asting: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp / V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL Fl-VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blocki 2472 19776 SPACES Name Area Volume Kitchen Occupants Bedrooms Intl ID Finished Cooled Heated Number 1 Main 2472 19776 Yes 6 5 1 Yes Yes Yes FLOORS # Floor Type YP Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 240 ft 0 2472 fF ---- 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Materials Area Area Color Absor. Tested Tested Insul. (deg) # Type 1 Hip Composition shingles 2678 ftz 0 fF Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 i 2472 ft2 N N CEILING V F 7=9 Ceiling Type Space i R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2472 ftz 0 Wood Page 2 of 4 12/12/2017 2:02 PM EnergyGauge® USA v5.1 - Section R405.4.1 Compliant Software I FORM R405-2014 r WALLS cavity Width Height ty Sheathing Framing Solar Below r�r;ktie Adjacent Space _ Area R value Frac:hnn Ahsor N Exterior Concrete Block - Int Insul Main 4 68 4 9 615.0 ftz 0 0.75 0 2 E Exterior Concrete Block - Int Insul Main 4 31 8 248.0 ftz 0 0.75 0 _ 3 E Exterior Concrete Block - Int Insul Main 4 22 6 8 180.0 ftz 0 0.75 0 _ 4 S Exterior Concrete Block - Int Insul Main 4 68 4 8 546.7 fiz 0 0.75 0 _ 5 W Exterior Concrete Block - Int Insul Main 4 29 6 8 236.0 ftz 0 0.75 0 _ 6 W Exterior Concrete Block - Int Insul Main 4 22 8 176.0 ftz 0 0.75 0 DOORS # Omt Door Type Space Storms U Value Ft Width In Height Ft In Area 1 E Insulated Main None .28 3 6 8 20 ftz 2 W Insulated Main None 17 3 6 8 20 ftz WINDOWS Orientation shown is the entered, Proposed orientation. I Overhang ff::::�2 Wall rnt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening N 1 Vinyl Low-E Double Yes ; 0.3 0.21 11.4 ftz 2 It 0 in 1 ft0 in None None E 2 Vinyl Low-E Double Yes 0.3 0.21 47.3 IF2 ft 0 in 1 ft0in None None E 3 Vinyl Low-E Double Yes 0.38 0.22 40.0 ftz 8 It 8 in 1 ft0 in None None 4 S 4 Vinyl Low-E Double Yes 0.3 0.21 47.3 IF 2 It 0 in 1 ft 0 in None None g W 5 Vinyl Low-E Double Yes 0.3 0.21 31.5 ftz 2 It 0 in 1 tt 0 in None None 6 W 5 Vinyl Low-E Double Yes 0.3 0.21 11.4 ftz 2 it 0 in 1 ft0 in None None 7 W 6 Vinyl Low-E Double Yes 0.3 0.21 31.5 ftz 5 It 0 in 1 ft0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1648 90.47 170.15 .1906 5 HEATING SYSTEM # Sub a System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM _ # Subtype System Type Sub a Efficiency Capacity Air Flow SHR Block . Ducts None SEER: 16 56 kBtu/hr 1680 cfm 0.75 1 sys#1 1 Central Unit 12/12/2017 2:02 PM � g Ener Gau e® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 4 FUKM K4U*-LUI4 HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation Electric None Main 0.98 40 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM EC rF Collector Storage t # Company Name System Model # Collector Model # Area Volume FEF ne None ft2 DUCTS ---- Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 494.4 ft Attic 123.6 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb He an Mar WApr Apr May X Jun rl Jul May Jun Jul ri Aug Aug p Sep W Oct Oct HNov N v Dec Venting [ Feb Mar Thermostat Schedule: HERS 2006 Reference Hours 9 10 11 12 Schedule Type 1 2 3 4 5 6 7 8 Cooling (WD) AM 78 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 PM 80 Cooling (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) PM gg 68 66 68 68 68 68 68 68 68 68 66 68 66 Heating(WEH) 6g 68 68 68 68 68 68 68 68 68 66 66 PM 12/12/2017 2:02 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 y ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD' ESTIMATED ENERGY. PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. - 9620 Carlton Rd, Port St Lucie, FL, 34987 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms S. Is this a worst case? 6. Conditioned floor area (W) 7. Windows" Description a. U-Factor: Dbl, U=0.30 SHGC: SHGC=0.21 b. U-Factor: Dbl; U=0.38 SHGC: SHGC=0.22 c. U-Factor: N/A SHGC: d. U-Factor: NIA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: New (From Plans) Single-family 1 5 No 2412 Area 18025 ft2 40.00 ft2 ft2 ft2 3.640 ft. 0.212 8. Floor Types Insulation Area a. Slab -on -Grade Edge Insulation R=0.0 2472.00 ft2 b. N/A R= ft2 c. N/A R= ft2 9. Wall Types a. Concrete Block - Int Insul, EXterior b. N/A c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A .c. NIA 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Insulation R=4.0 R= R= R= Insulation R=30.0 R= R= Area 2001.70 fta ftz ftz ftz Area 2472.00 ft2 ftz fe R ft2 6 494.4 kBtu/hr Efficiency 56.0 SEER:16.00 kBtu/hr Efficiency 34.0 COP:1.00 Cap: 40 gallons EF: 0.98 Pstat 0, 1r aar�lftt�4. �; 60- M "Note: This is not a Building Energy Rating. If your Index is below 7.0, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 636-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, .contact the"Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/12/2017 2:02 PM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1