HomeMy WebLinkAboutProduct Approval Single HungFlorida Building Code Online
Fio0a Department!
3usines )
Profess i ia1
Regulation
l
. }�
Page 1 /of 2
BCIS Home f Log In 1 User Registratibn s Hot Topics ; Submit Surcharge ; Slats & Fads Publicath
I " Product Approval
USER: Public User
Product Aoproval Menu>Pmdud or HpolicaEionSearch>APulicEApproved
on Detall
FL"# -R1
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email,
Authorized Signature
Technical Representative_
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance. Contract Expiration Date
Validated By
Certificate of Independence
G
Custom Window Systems Inc.
1900 SW 44th Avenue
Ocala, FL 34474
(352)368-6922
ekoss@cws.cc
Koss Erin
ekoss@cws.cc
Erin Koss
1900 SW 44th Ave..
Ocala, FL34474
(352)368-6,922 Ext291
ekoss@cws.cc
Jay Lathrop
1900 SW 44th Ave.
Ocala; FL,34474
(352) 368-6922 Ext 291
jlathrop@cwscc
Windows J
Single Hung II
i
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
' Z Evaluation Report- Hardcopy Received
Lucas A. Turner
PE-58201
Keystone Certifications, Inc.
07/21/2020
Steven M. Urich, PE
', Validation Checklist- Hardcopy, Received
Referenced Standard and Year (of Standard) Standard
Year
AAMA/WDMA/CSA/101/I.S.2/A440-08 2008
ASTM E1300-04 f 2004
ASTINI E1886r05 C 2005.
ASTM E1996-09 2009
PA TAS 201/202/203 1994
.Equivalence of Product Standards ails Copy
Certified By-�
i
}
i
I
htq)s://floridabuilding.org/pr/pr_app 4tl.aspx7param=wGEVXQwtDqvyf4ngAXhIOy8Qt,... 10/27/2015
Fld ida_Building Code Online
Page 2 of 2
Sections from the Code
A.
Product Approval Method
Method 1 Option D
Date Submitted
04/14/2015
Date Validated
04/21/2015
Date Pending FBC Approval
04/25/2015
Date Approved
06/22/2015
Summary of Products
.,
L'
fL #
Model, Number or Name
Description
16177.1
SH-8160 PVC Single Hung
SH-8100,PVC Single Hung Impact°:Resistant
window.
Limits of Use
Installation Instructions
}t
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes.
Impact Resistant: Yes
fL16177 R1 II CINS-812B (SH-8100
IMP .NoSillAnch) pdf
Verified By: Lucas A. Turner 58201
Created by Independent Third Party: Yes
Design Pressure: +70/-70
Other: SH-8100 PVC Impact, no sill anchors required.
Safety glazing required on outer lite above 30 ft. in HVHZ
Glass complies to ASTM E3300-04.
Evaluation Reports
FL16177 R1 AE DuPont PVB NOA 13-0129 27 odf
FL16177 R AE EvalReo CWS-8128
(SH-8100 IMP
NoSillAnch).odf
FL16177 RS AE Ouanex (Mikronl
NOA 12-1017 02 odf
Created by Independent Third -Party:
'Yes
Back Next
Contact us. k: 191Q North Monroe Street Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AAIEEO employer. Copyright 2007-2013 State of Florida..: PrhOcv5tatement :: Acresslb0itv:5
Under Florida law; email addresses are public records. If you do not want young -mail address released in response toapp
electronic mail to this entity. Instead, contact the office by, phone or traditional mail. Ifyou have any, questions, please a
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the
they have one. The emalls provided may be used.for official communication.with the licensee. However email, addresses are.;
supply a personal address, please provide the Department with an email address whichcan be made available to the public. To
Chapter 455, F.S., please ddc here
Product Approval Accepts:
5[TUritvsmr itww
:: Refund Statement
s request, do not send
487.1395. -Pursuant to
�t with an.email address if
rd. If you do not wish to
if you area licensee under
httpsa/www.floridabuilding.org/pr/pr_app_dtl:aspx?param=wGEVXQwtDgvyf4ngA)hl6y.., 8/4/2015
.SINGLE HUNG - LARGE MISSILE IMPACT
1/8" MAX. OVERALL FLANGE WIDTH
—51 7/8" MAX. UNIT WIDTH—
—4711/16 GLASS DLO.
A
63"
MAX.
- --t -
OVERALL
i
FLANGE
HEIGHT
B
� I
I
G1
3/4^
t
MAX.
UNIT
HEIGHT
I
30 NIS,
I
V
I.
MAX.
SASH
HEIGHT
I
f..
x
■1
TABLE OF CONTENTS
GENERAL NOTES:& ELEVATIONS.....1
GLAZING DETAIL, .....................2
SECTION VIEWS.................................3
EXTRUSIONS & B.O.M........................4
ANCHOR SCHEDULE & NOTES
INSTALLATION DETAILS....................6
A
— 451116
GLASS DLO
48 W8"
MAX. SASRWIDTH
R
X,
i
ti
1,THEP PRODUCT
1,THEPRODUCT SHOWN HEREIN ISDESIGNEDC AND MANUFACTURED
6bge ���j77
TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC), CURRENT
WINDOW SYSTEKS
EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND
1900 SW`44TH AVE.
IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED
OCALA, FLORIDA 34474
IN ASTM E 1996 PER THE FBC.
W W W.CWS.CC
2. GLAZING OPTIONS: (SEE SHEET 2)
8100 PVC
3. CONFIGURATIONS: "O.
IX
SINGLE HUNG
4. DESIGN PRESSURE RATING:
IMPACT
-NEGATIVE, DESIGN LOADS BASED ON, TESTED PRESSURE AND
GLASS TABLES ASTM E-130D-04.
-POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER
a
INFILTRATION TEST PRESSURE AND GLASS TABLES
ASTM E-130.0-04,
c
r
F
5. ANCHORAGE: THE 33 1/3h STRESS INCREASE HAS NOT BEEN USED
IN THE DESIGN OFTHIS PRODUCT. SEE SHEET'6 FOR ANCHOR
DETAILS.' WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD
ANCHOR CALCULATIONS.
B 26
6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE
GLASS
DLO
NOT REQUIRED.
7. ALL FRAMES AND, VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT
USED AT FIXED MEETING RAIL AND JAMB.
8. SERIES / MODEL DESIGNATION SH-8100.
9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING:
X= OPERABLE SASH, O = FIXED SASH
26718"
10. SECTION CALLOUTS APPLYTO ALL ELEVATIONS .IN A SIMILAR
GLASS
LOCATION.
DLO
I
11. EXTERNAL WEEP SLOT = 1/4" X 1-1/4" LOCATED 4" FROM BOTH ENDS.
MAX. UNIT SIZE
DESIGN PRESSURE
IMPACT RATING
RATING
5.1-7/8" x 61-3/4"
+/- 70 PSF
LARGE MISSILE IMPACT
Lucas A.
Tumer
201 &04-11
15:15-04:00
v : No 58201
41 er
90: STATE OF 7**,(U6.
g' 451ONA li E�
z
4111/2015
LUCAS A. TURNER, P.E.
FL PE # 59201
1239 JABARA AVE.
NORTHPORT, FL34288
GENERAL NOTES AND
ELEVATIONS
IAWN BY: DATE:
BAT 06/18/12
G x: .
CWS-812 B
7 SHEET
1:15 1 OF6
4"
4, 1
ANCHORLAYOUT- (FLANGE)
c
NOTE 2
ALLATION
HOR (T'P.)
RAIL
NOTES:
1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.:NO ANCHORS REQUIREDIN SILL
2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS: MAX. ALLOWABLE SHIM STACK TO BE 14'. USE SHIMS WHERE SPACE GREATER THAN III 6" IS PRESENT. LOAD BEARING SHIMS SHALL BE
CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.
3.ANCHOR TYPE; SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6,
4, ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST
BE PROTECTED TO PREVENT REACTION.
S. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM
SPECIFIED IN TABLE 1, SHEET'6.
6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS; IF USED, INTO SUBSTRATE.
INSTALLATIONS TO SOLID CONCRETE OR GROUT•FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE.
INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3" FOR MASONRY, 1" FOR WOOD AND METAL.
8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS' SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE.
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TASLEI, SHEET S. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.
9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS:
FMA/AAMA 106(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAIWDMA 250(BOX WINDOWS), FMNAAMAAVDMA 300(EXTERIOR DOORS)
WINDOW TEES
1900 SW 44TH AVE.
OCALA„FLORIDA 34474
WWW.CWS.CC
8100 PVC
SINGLE HUNG
IMPACT
No 58201
STATE OF
4/11/2015
LUCAS A. TURNER, P.E.
FL PE # 58201
ANCHOR SCHEDULE AND
NOTES
,RAW BY:
DATE:
BAT
06/1.8/12
66 O
FREV.:
CWS-812
B
ALB;
SHEET
1:15
5OF6
SUBSTRATE BY OTHERS
SEE TABLE 1
PERIMETER SEALANT—
BYINSTALLER
INSIDE AND OUT
SEALANT BEHIND -
FLANGE 'BYINSTALLER
INSTALLATION ANCHOR
SEE TABLE 1
SEALANT BEHIND
FLANGEBY INSTALLER
PERIMETER SEALANT —
BYINSTALLER
INSIDE AND OUT
SUBSTRATE BY OTHERS
SEE TABLE 1
TYPICAL HEAD
MANCHORAGE
-{
L . ,
1
MAX. SHIM
MAX. SHIM
1 -i—.MIN. EDGE'DIST.
SEE TABLE 1
OA VERTICAL SECTION
`� TYPICAL SILL ANCHORAGE
TABLE 1: APPROVED INSTALLATION FASTENERS
STRATETYPE
ANCHOR TYPE
MIN. EMBEDMENT
MIN, EDGE DIST.
CRETE (2,0 KSI MIND
3/16" ITW TAPCON
1 172"
1-178°
LM OR-C[BOUTEILLED_CMU.(.1.17.P_CF MIN.)-
[GROUT-FILLED
3C16"-ITW-TAPCON—-•-----.-
--�-----1 .
- 2"-
CRETE (2;85 KSI MIN.)
3/16" ELCO ULTRACON
CMU (ASTM C-90)
3/16" ELCO ULTRACON
1:1/4'
24/2"
2XMIK SOUTHERN PINE (G=0.55)
3/16' ITW TAPCON
OR ELCO ULTRACON
1318°
7%8"
2XMIN. SOUTHERN PBJE (G=0.55)
#10 WOOD SCREW
1.3l8"
7/8"
I6 GAUGE (0;gg0'7 MIN. STEEL STUD
(33 KSI YIELD MIN)
410-16 HILTI KWIK•FLEX OR RW
TEKS SELF -DRILLING SCREW
FULL THREAD
THRU 0.060"
118" ALUM. (6063.75 MIN.) OR
1/8" STEEL (33 KSI MIN:)
010 GRADE 5 SELF•TAPPING /
DRILLING SCREW
FULL THREAD
THRU 0.125"
INSTALLATION
SEE TABLE 1
MIN. EMBEDMENT
SEE TABLE 1
114" MAX.SHIM—
MIN.
SEE
WINDOW SYSTEMS
1 1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CWS.CC
IST. 8100 PVC
SINGLE HUNG
IMPACT
—PERIMETEASEALANT
BYINSTALLER
INSIDE AND OUT
SEALANT BEHIND
FLANGE BY'INSTALLEI
rB1 HORIZONTAL SECTION
B TYPICAL JAMB ANCHORAGE
-Z7: No 58201
-P STATE OF -: u;
�`_,�.
v�,TSC
F4, 0 R .p P,
4/11/2015
LUCAS A. TURNER, P.E.
PERIMETER SEALANT
BYINSTALLER
FL PE # 58201
1239 JABARNAVE.
---INSIDEAND OUT ----- - —
—NORTN-PORTrFL 34288-
K-C'\ HORIZONTAL SECTION
PH.841-380.1574
�BOXFRAME INSTALLATION
SHEET DESCRIPTION:
HEAD AND SILL SIMILAR FOR BOX INSTALLATION
INSTALLATION DETAILS
FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE,
UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED:
DRA B :
A E:
MIN, 1/4"FILLET OF CONSTRUCTION•GRADEADHESIVE CAULK IS APPLIED
BAT
06/18/12
INSIDE AND OUT, FULL PERIMETER, BY
Dan;
INSTALLER.
PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS
CVVS-812
B
SHOWN FOR FLANGE WINDOWS.
'0A '
SHEET
12
6OF6