Loading...
HomeMy WebLinkAboutProduct Approval Swinging Exterior DoorI „a toil BCIS Home Log In User Registration Hot Topics I Submit Surcharge Stats & Facts I Publications I FBC Staff BCIS Site Map I Unks Search Product Approval dbor � USER:PublicUser Product Approval Menu > Product or Application Search > r FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method > Application Detail FL17184-R3 Revision 2014 Approved Plastpro Inc. / Nanya Plastics Corp. 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440) 969-9773 Ext16 rickw@rwbidgconsultants.com Vivian Wright rickw@rwbidgconsultants.com Scott Johnson 5200 W Century Blvd. Los Angeles, CA 90045 (440)969-9773 Ext18 scottjohnson@plastproinc.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation & Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King, P.E. Z Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL17184 R3 COI Certificate of Independence.odf Standard AAMA/W DMA/CSA101/I. S.2/A440 ASTM E1886 ASTM E1886 ASTM E1996 ASTM E1996 ASTM E1996 ASTM E330 TAS 201, 202, 203 Year 2005 2005 2002 2002 File ile Copy a opya 2005 2002 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products, Go to Page riYv Method 1 Option D 03/10/2016 04/18/2016 04/18/2016 06/08/2016 0 0 Page t / 310 0 FL # Model, Number or Name Description 17184.21 u. Fiberglass Door Up to a 3'0 x 6'8 Glazed "Impact" Fiberglass Single Door (X Configuration) Inswing/Outswing Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R3 II Inst 17184.21.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.21 for any additional use limitations, FL17184 R3 AE Eval 17184.21.pdf installation instructions and product particulars. Created by Independent Third Party: Yes 17184.22 v. Fiberglass Door I Up to a TO x 6'8 Glazed "Impact" Fiberglass Single Door with a Sidelite (OX or XO Configurations) Inswing/Outswing Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R3 II Inst 17184.22.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.22 for any additional use limitations, FL17184 R3 AE Eval 17184.22.pdf installation instructions and product particulars. Created by Independent Third Party: Yes 17184.23 l w. Fiberglass Door l Up to a TO x 6'8 Glazed "Impact" Fiberglass Single Door with a Sidelite (OXO Configuration) Inswing/Outswing Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R3 II Inst 17184.23.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.23 for any additional use limitations, FL17184 R3 AE Eval 17184.23.pdf installation instructions and product particulars. Created by Independent Third Party: Yes 17184.24 x. Fiberglass Door Up to a 6'0 x 6'8 Glazed "Impact" Fiberglass Double Door(XX Configuration) Inswing/Outswing Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R3 II Inst 17184.24.1)df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.24 for any additional use limitations, FL17184 R3 AE Eval 17184.24.odf installation instructions and product particulars. Created by Independent Third Party: Yes 17184.25 y. Fiberglass Door Up to a 6'0 x 6'8 Glazed "Impact" Fiberglass Double Door with Sidelites (OXXO Configuration) Inswing/Outswing Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R3 II Inst 17184.25.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.25 for any additional use limitations, FL17184 R3 AE Eval 17184.25.pdf installation instructions and product particulars. Created by Independent Third Party: Yes 17184.26 z. Fiberglass Door Up to a nominal 3'0 x 70 "Non -Impact" Glazed Fiberglass Single Door with or without "Non -Impact" Sidelites (X, XO or OX, OXO Configurations) Inswing/Outswing plastpro 5200 W. CENTURY BLVD. LOS ANGELES, CA 90045 GLAZED FIBERGLASS DOOR INSWING / OUTSWING 'IMPACTr' GENERAL NOTES 1. This product has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. Z. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E 1996 and Section 1609.1.2.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTE= SHEET# DESCRIPTION I . Typical elevation; design pressures, & general notes 2 Door panel details 3 Horizontal cross sections 4 Vertical cross sections 5 Buck and frame anchoring - 2X buck masonry construction 6 Frame anchoring -1X buck masonry construction 7 Bill of materials, glazing detail & components 37.50 MAX. OVERALL FRAME WIDTH SWING _ _ . ,. OVERALL FRAME ,DIMENSION ,, OVf=RACL DLO: : DIMENSION GLASS ........ DESIGN PRESSURE (PSF7:; POS[TlVE .NEGATNE INSWING 37.60" x 82.00" 20.50" x 62.75" G1 +50.0 -50.0 OUTSWING 37.50" x 80.50" 20.50" x 62.75" +50.0 -50.0 Pc. BY. AL IL BY. LFS AWMB NW FL-17184.21 EEr 1 of 7 I or r -0 00 z z ru ?< f4 I rsg R �! � 'S P. r- AD. �-p' NODATE02014 R.W. BUILDING OGN—L—NTS IND 792S'MAX. DOOR PANEL HEIGHT 62.75'MAX. D.L.O. HEIGHT — - a cn O� go O.C. F77M—T 0 W. :0 0 ;mu PRODUCT. PLASTPRO INC. FIBERGLASS DOOR PART OR ASSEMBLY: DOOR PANEL DETAILS 0 0 .2 m 0 9 %% N0.43409 nente Prepared By:-�V, MS No. 43409 % )n F. Schmidt BUILDING CONSULTANTS. INC. P.O. Box 230. Valrico. FL 33595 Phone No.: 813.059.9197 FBPE-C.A. No. 9813 R:1Cu'ntslPlasWro, Inc PMMM MW - Florida Product Approvals\FL-17384 FihMgWss Door-LisvMn9'0 'N9\C- Drawings\Curtent\FL-1718421-25.dwg, 1.3 Z m p y W -+ p 0 oUri.� e- n 00 2 0-ram O o n T V Z o z Cq z W -+ M I29 � 0 A W A tr A � Aa A A A O. V W W W W p a T �1 M O O ww 00 p 1 g V � N O 0 A M A X x2 gcr V n t_ c 70 N 0 W N1 OO A � y p1 a n N a� zO O Z 3p V m r• V ' 7n0 K! r n � v 0 Tv T A No.49409 r R Q ar' PRODUCT: PLASTPRO INC. Documents Prepared �''�i Lyndon F. Schmidt Oo FlBERGLASS DOOR P.E. No. 43409 Iw � Do Z y in N w K�r� BUILDING CONSULTANTS, INC. 2 3 10 16 ADDED ADA O.S. BUMP THRESHOLD JK PART OR ASSEMBLY: 1 15 UPDATE TO STH ED. (2014) FBC JK IV N HORIZONTAL CROSS SECTIONS d lr Ul/ P•0. Box 230, Valrico, FL 33595 Y NO DATE BY Phona No.: 813.659.9197 FBPE CA No. 9813 REVISIONS 02014 R.W. BUILDING CONSULTANTS INC. d 0 X v '1 R:\Olents\Flastprs, Inc PERMANDNT\A - Florida Product ApprovalskFL-17184 Flberglao Door - InsMn9-0utswN9\C - Drawings\CunerR\R-171B9.21-25.dw9. 19 m m m a m m ;;0 g ¢ ° m ,e Q•. g T ° 0 T CL pa O ° T Q. .° W � p 0.1s° 1-1/4"MIN. o. CSINK '- v EMB. (TYP.) (NP.) 1-1/4° MIN. m EMB. (TYP.) Z m A ,pp e ° Z o m ;4-. A In A ;_ A�Q O n 3 T ° D '•O Q 0 Z e +� rt1 � = 0 0 N T an e m W � O WNW. MIN. EMB. (TYP.) 1-1 /4• MIN. EMB. (TYP.) 1-1/4° MIN. 7� m EMB. (TYP.) .� A N m a W = O $ ril e •° °e AA Z X� e a T .. qO CCC e O a ' 152 �.. sQ az m < N m 22 0 40 n22 �. � N0.43409 1-IMMIN. :* EMB. (TYP.) - vy `� �j PRODUCE: PLASTPRO INC. Documents Lyndon Prepared Br.�� F. Schmidt %-Z� ' • I m FIBERGLASS DOOR P/.EE.. .(•�•' `���` No. 43409 /// �0�� (I� % y LNr1 K BUILDING CONSULTANTS, INC. 2 3 10 1B ADDED ADA O.S. BUMP THRESHOLD JK PART OR ASSEMBLY: 1 G4 22 15 UPDATE TO WH ED. 2014 FBC JK I-4 vERncaL CROSS SECnONS d l� PO. Box 230• Valrleo• FL 33595 NO DATE aY phone No.: 813.859.9197 REVISIONS FBPE CA No. 9813 0 2C 1 4 R.W. BUILDING CONBULTANTB INC. MASONRY OPENING 2X BUC 91 BUCK ANCHORING fL CONCRETEANCHOR NOTES: 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortar joints. 2 Concrete anchor locations noted as "MAX. ON CENTER"must be adjusted to maintain the min. edge distance to mortar joints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. t; 3. Concrete anchor table: . ......... . .. ..... ............... .......... ... ..... ............... Q .MA ...........-- ............ ADJACENT.:;;::; WOOD SCREW INSTALL417ON NOTES: 1. Maintain a minimum 518"edge distance, 1 " end distance, & I " 0-c- spacing of wood screws to prevent the splitting of wood. LO At �0 ......... ..... TYP. HEAD & 3h INL OZ no 0 ZOE) N .: MASONRY —71 JAMBS 4 9 0 X zo zg 0 OPENING d go.fi t La a: CZ La 77 FRAME 2 g,-- 2X BUCK L? 0 owo TYP' N 6 SILL. 0 W :3M IL a) I imu HINGEJAMB FRAMEANCHORING SWKE JAMS iE a Masonry 2X buck construction r-1 T1 . HINGE DETAIL LATCH DEADBOLT DETAIL AL: N.T.S. t P& ar AL IL er LFS Awn NO.: FL— 17184.21 EEr OF tl a t t 7 = HINGE DETAIL LATCH & DEADBOLT DETAIL CONCRETE ANCHOR NOTES: 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortar joints, additional concrete anchors may be required to ensure the 'MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: ::A:NCNOR::AN(N.Ok' Z; ::`:':MIl1(:•':•:•:::;: II�iNCLEF}RlfiJCB:=NIIIVCLE�?�;RAAtCE ..........:..................... ::rii ...................TO iV'PE J MB DXA@NI ;;;;:tYYASONRY c>?......•,.,...,....:......;...:;•;> TO ADJACENT . ..................... .... ........................... .......... .. ...................................................................... . ELTL'+E:.:......:::::; ,:......-:ANCHOR.,....:• ITW 1/4" 1-1/4" 2" 4" TAPCON® ELCO ® IN 1.1/4" i" 4" ULTRACON ITW ® 3/16" 1-1/4" 3" TAPCON WOOD SCREW INSTALLATION NOTES: 1. Maintain a minimum 5/8" edge distance, 1"end distance, & 1" o.c. spacing e wood screws to prevent the splitting of wood. HINGE JAMB a a• TYP. HEAD & MASONRY JAMBS OPENING FRAME 1 X BUC FRAME ANCHORING Masonry 1 X buck construction Z �I �••�•v tg,� Sib; %S J ao R:fi.K. . O D o n m z° U N•; �$ 9 U X Z q Em zoo 8$ Eg 9 d o a "� \vV� m d a 4 C6 0 a ax 514 JTa Fuy�i Y mo m O O WO €^ o a o� o: �o N En Z o V) �w h STRiKEJAMB ro. er AL m x.6Y; LFS 3 AWM NO.: FL-17184.21 a EET _jL OF 7 N • 6 1 9 BILL OF MATERIALS ITEM DESCRIPTION MATERIAL A 1XBUCKSG>=0.55 WOOD B 2X BUCK SG >= 0.55 WOOD C IN MAX. SHIM SPACE D 1 /4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE F 1/4" X 2-1 /4" PFH ELCO OR ITW CONCRETE SCREW STEEL G 3/16" X 3-1/4" PFH ITW CONCRETE SCREW STEEL H 1 /4" X 3-1 /4" PFH ELCO OR ITW CONCRETE SCREW STEEL J 1/4" X 3-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL L #10 X 2-1/2" PFH WOOD SCREW STEEL M #8 X 2-1 /2" PFH WOOD SCREW STEEL N 1 /4" X 1-3/4 PFH ELCO OR ITW CONCRETE SCREW STEEL 6 SEALANT SILICONE 7 WEATHERSTRIP FOAM 9 4" HINGE STE 10 #10 X 3/4" PFH WOOD SCREW STEEL 20 JAMB FINGER -JOINT -PINE WOOD 21 POLYFIBER COMPOSITE JAMB POLYFIBER 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT PLATE STEEL 30 DOOR SWEEP 31 OUTSWING THRESHOLD BY DLP ALUM. / WOOD 32 ADA THRESHOLD ALUMINUM 33 INSWING THRESHOLD BY DLP ALUM. / WOOD 36 OUTSWING ADA BUMP THRESHOLD ALUMINUM 40 DOOR PANEL - SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 41 DOOR SKIN (MIN. 0.075" THICK) PLAST-PRO/NANYAFy =11,063 PSI MIN. FIBERGLASS 42 TOP RAIL CELLULAR PVC 43 LATCH & HINGE STILE CELLULAR PVC 44 REINFORCEMENT WOOD FOR LOCKS WOOD 45 BOTTOM RAIL CELLULAR PVC 46 FOAM CORE POLYURETHANE 47 LATCH & HINGE STILE REINFORCEMENT LVL 51 ODL LITE FRAME ALUMINUM 52 #10 X 1-3/4" PFH SCREW STEEL 53 GLAZING COPOUND REDI-SEAL BY ODL, POLYMERIC FOAM P/MERIC FOAM 54 STRUCTURAL SILICONE DOW #995 SILICONE 55 SCREW PLUG 4.56" 70 HEAD 3 SIDE Jamb 4.56' 91 QOSHOU NG THRESHOLD ADA SILL ISHC 0 5" o T OUTS NGADABUMP 1 ES O 36 OSHC d) d m z dm i � •. �� � °c 01 �4 v v e z ~ 9Occ t' con: a. l CZ LF z S �d 4L HEAD SIDE z PoIy fiber jamb ocbz 4.56' �o yw F a� o �Q o m INSWING THRESHOLD a ISCS GI LALNGDEiAI! DVERALL ASS THK. 1/8" TEMPERED GLASS AIR SPACE 1/8" ANNEALED GLASS 0.090" SAFLIX® PVB INTERLAYER 1/8" ANNEALED GLASS X: N.T.S. fo. BY: AL m' x MI. LFS 3 AWNO NO.: FL-17184.21 v a EEr 7 OF 7