Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL SKYLIGHT7/16/21, 4:51 PMFlorida Building Code Online Page 1 of 3https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtbxPqODTr%2bX3SmdxkQz1gYkti9hvFBgwBsiNia5FSUxg%3d%3d BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL20881-R5 Application Type Affirmation Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Sun-Tek Mfg Address/Phone/Email 10303 General Dr Orlando, FL 32824 (407) 859-2117 jfeudner@sun-tek.com Authorized Signature James Feudner engineering@sun-tek.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Sky Lights Subcategory Skylight Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard)Standard Year TAS201 1994 TAS202 1994 TAS203 1994 Equivalence of Product Standards Certified By I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. 7/16/21, 4:51 PMFlorida Building Code Online Page 2 of 3https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtbxPqODTr%2bX3SmdxkQz1gYkti9hvFBgwBsiNia5FSUxg%3d%3d Documentation from approved Evaluation or Validation Entity Yes No N/A FL20881_R5_COC_ICMGII 2020 FBC letter.pdf FL20881_R5_COC_IFGC 2020 FBC letter.pdf Product Approval Method Method 1 Option A Date Submitted 12/04/2020 Date Validated 12/04/2020 Date Pending FBC Approval Date Approved 12/12/2020 Summary of Products FL #Model, Number or Name Description 20881.1 ICMGII ICMGII (Impact) Aluminum Skylight Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Certification Agency Certificate FL20881_R5_C_CAC_NI013292-R2 ICMGII.pdf Quality Assurance Contract Expiration Date 03/31/2022 Installation Instructions FL20881_R5_II_ICMGII installation inst - Approved 6.21.16 JW.pdf Verified By: James D Wells Jr. P.E. P.E. No. 53616 Created by Independent Third Party: Yes Evaluation Reports FL20881_R5_AE_2017FBC ICMGII report.pdf Created by Independent Third Party: Yes 20881.2 IFGC IFGC 4949 Flush Mounted Wood Skylight Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Certification Agency Certificate FL20881_R5_C_CAC_NI013293-R3 IFGC.pdf Quality Assurance Contract Expiration Date 03/31/2022 Installation Instructions FL20881_R5_II_1283.IF - IFGC Install Inst - Final - Approved 7.26.16 JW.pdf Verified By: James D. Wells Jr. P.E. No. 53616 Created by Independent Third Party: Yes Evaluation Reports FL20881_R5_AE_2017FBC IFGC report.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 7/16/21, 4:51 PMFlorida Building Code Online Page 3 of 3https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtbxPqODTr%2bX3SmdxkQz1gYkti9hvFBgwBsiNia5FSUxg%3d%3d This item has been electronicallyEngineer of Recordsigned and sealed by James DJames D Wells, Jr,PEWells, Jr,PE on 6/21/2016 Using- 401- . Professional Engineer No 53616INSTALLATION INSTRUCTIONSa Digital Signature*AM#rSun-Tek Manufacturing, IncJ & L Wells Consulting LLC10303 General DriveINSULATED GLASS SERIESaPrinted copies of this documentI7, -44.1453 Arbitus Circle0Sun TekOrlando, FL 32824are not considered signed andOviedo, FL 32765407 / 859-2117MODEL ICMG11sealed and the signature must be -1ªA{SKYL GHTS(407) 496-5489www Sun-Tek comUse on any type roof (curb required)verified on any electronic copiesL*45.Ä*u,L, CustomerService@sun-tek comCertificate of Authorization No 27162t«-':SIZE INFORMATIONFastener ScheduleJames D WellsSKYLIGH TO CURB CURBTODECKJr#12*2 Pillips Pan #10*21: DeckFinishedHead ,crewsScrewsUr iOpeningFits onShortLong Short Long£Ä111, 1/,/I attest to theSizeRoofSideSideSide SideItM" Drywal| Curb Outside Center/4* accuracy andCode Opening Dimension) Dimension SpacingIPer)(Per)(Per) {Per)\*S40 43616 hic- Integrity of1414 111/2"x 111/2" 101/2"* 10'h" 14'/2"X 14'h"16"22221422 1172"x 1916" 101/2"X 181/i" 14'h"X 221/2"•* STATE OFty*41 OR# -*7 this document16"22231430 111/2"x 276. 101/2"X 261/2" 14'X 301/2"162323'##111)""201606211-CURBOD -'///ffill116"24241425 51\1; 1"]Il 11",S211 14716"2323\-04'00'I *4-I1733 1471"x 3(Oh" 13,h"X 29'h" 17'4'X 33/216.1-423233 - Finished4486ª-1749 141/i"x 46th" 130"* 450" 176"x 49/2"16"2424 Opening2222 191/2"x 191/2" 18,h"x 18'h" 22%"x 221/2"24"3333Roof2230 19th"x 271/2" 181/1"x 261/i" 221h"X 30'/2"24"3333Opening -2246 1914"*439," 181/1"x 421/" 2214"x 461/2"24"3434You will need:2525 221/,"x 221h" 211/1"X 211/i" 251/z"x 25/2"24"3333CLEANING YOUR SKYLIGHTSTS 1000 Caulk - Use only between decking and underside of skylight flange onā hammerā sealant/masticUse a mild soap and water or glass cleaners only Fresh paint splashes, glazing Glass Series Not necessary on CMG22533 221/2"x 301/," 211/2"X 291/" 251/2"x 331/2"24"3333ā keyhole sawā tape measurecompound, etc may be removed by rubbing lightly with a soft cloth or cotton ball2549 221/i"x 461/2" 211/1"X 451/2" 251/"X 491/224"3434ā skill sawā chalkline or straight edgesoaked in mineral spirits3030 27/"x 2702" 261/1"x 261/" 30'h"X 3014" 16"or 32"3333ā nailsā trowel or caulkgunACCESSORIESStep Flash Kit- Pre-formed, precut flashing eliminates need for flashing on self-builtā drillā utility knife3046 271/,"x 431/2" 261/2"(429." 301//x 461/2" 16"or 32"3434Skyhght Shades - a variety of sizes areavailableand are easily installed Contactyour curb Use with Curb Mount models Note Step flash kit designed for use with curbsā 2 x 4'sbuilding materials dealeror Sun-Tek Manufacturing fordetails3333 304"x 301/z" 2914"x 291/2" 331/2"x 331/2" 16"or 32"3333constructed of 2 x 61 onlyFor Light-funnel RECOMMENDED SEALANTS:3349 301/2"x 46'h" 291h"x 451/1" 331/2"( 491/2" 16"or 32"3435ā 8 or 10 penny nails ā 100% Silicone4646 431/2"*431/2" 4216"*421/," 461/2"x 461/2" 16", 24"or 48" 4455LIGHT TUNNEL INSTALLATION INSTRUCTIONSā plywood ordrywall ' STS1000(Sun-Tek exclusive)4949 460"x 461/i" 450"x 45'h" 490"x 491h" 16; 24"or 48" 4455Butyl rubber sealant/caulkFor homes with an attic, it is necessary to build a tunnel between skylights and ceiling The tunnel walls may be straight, or flared for extra light andarchitectural appeal It's very easy to increase the tunnel size along the length of the ceiling Joists As long as no roof-supporting members are cut, nospecial framingis needed While it ispossibletoflarethetunnel inalldirections, ifsupportmembersare cut, special framing will be required forstructuralFAILURE TO FOLLOW RECOMMENDED INSTALLATION PROCEDURES MAYVOIDWARRANTYsupport In this caseyou must consult a qualified building professionalto insure proper and safe resultsCheck local building codes for glass requirements. ā Please read instructions completely before beginning. ā Deck and roofing1 After roof and ceiling openings have been framed, measure distance (at each corner of roofopening) between rafter/truss and ceiling jol st2 Using these four measurements, cut 2*4 lumber for vertical support members (two per corner)felt should already by installed.3 In each corner, nail vertical support members into place at right angles to each other4 Measure, cut, and nail tunnel walls into place Suggestions for lining tunnelI To properly position skylight between trusses/rafters, locate the roof opening £,/9//1 =from the underside of the decking (If this area is not accessible, locate the- use drywall, tape corners, and paint white using regular or texture paint (Texture paint alone, ./1\ceiling Joists from inside the house, mark opening in ceiling (a-c), and cutwill hide and fill untaped Joints, but In time, cracks may appear in corners )iceiling opening Then follow steps below for roof opening)- use prefinished paneling with molding in cornersa) measure distance between trusses/rafters and mark center point-line the tunnel with cedar, pine, ora wood to coordinate with yourdecorid 'h> 11- for special effects, try painting the tunnel a striking accent color, or use mirrors or wallpaperonb) tocenterskylight, measureone-half of appropriate roof opening to eachside of center point and marktunnel wallsc) using the sidemarks asaguide, markcorners by drilling holes or driving5 Caulkthe slight gap between thetunnel walls and skylight base\«L \6- -6 Finish offtunnelatcelling with molding, or blend edges Into ceiling with texture paintnalls through roof7 Be sure to wrap the exterlor of the tunnel with insulation forenergy savings2Remove shingles 6 - 8"out from roof openingSun Tek Manufacturing Inc z Sun Te19 10303 General Drive, Orlando Florida 32824 (407,859 211INSULATED GLASS SKYLIGHT LIMITED WARRANTY7 warrant,thus SIlighton*he followingtermsandconditions A Warranty Coverage -hi warrant) applies to both the original purchaser3Cut roof opening (snap a chalkline from corner to corner, or draw line with aand first consumer owner of a Skyhght made by Sun Tek B Warranty Duration This warranty shall remain in effect for a period of twenty (20) years after the date the SK> light is putased or the date the Skylight is delwered to the n'stconsumer owner whicheier,s later During the first ten 110 yearsof this warrantyperiod Sun Tek Industries covers 100 percent of .11 mater,al cost for the ent,re unit After 10 years following the initiation of this warranty Sun Tek Industrlestraightedge )will cover a pro rated portion and issuea credit as followsYearsCoverage11 to 1314 to 1685cS4Frame roof opening17 to 2025 percentThis 20 year limited warranty applies to glas, series skylights only for skylights manufactured after January 1 1908 For products manu factured before January 1,1998 the warranty period Iso >earsa) cut two 2 x 4's to fit the actual distance between trusses/rafters and nailC Warranty Application Thi warranty applies only to the materials and fabilcation orthe Sk>light and does netappl> toany defect or damage caused by improper use improper installation improper care or accident Glass breakage isinto placeNOTE Size 2525,2549,3333,3349,4949 Skip step"bnot covered D Performance by Sun Tek During the warranty period Sun Tek will providefreeof charge an ecurvalent M. skylight forcomponent thereof) for one found to bedefect,ve in materialor vorkmanship Shipping cost,ofsuchproceedreplacements.e nottherespons,bilityofSun Tek Sun Tekwillnotberesponsibl•foran¥cost,of removal or re installation Condensationot damaged caused ry condens'tion 15 not covered under his ./.IN E Valdation Procedureto C.Toobtain perfoimance Linder thus wairanty the purchaser must 11}On installed skylights, contact Sun Tek for instructions before removing skylight Removal of skylight from roof before inspection will void warranty (2) NotifySun Tek in writing of any claim within thirty (30) days after the defect is discovered and <3) Sun Tek orits authorized agents must examine high quality installed photographs of the subject skylight and determine to its satisfaction whetherb) cut two 2 x 4's to the exact length of the roof opening and nail to thethe defect is covered by thts w«irranty , and (4) Present acopy ofthe receipt as proof of purchase F Imphed Warranties IN'PLIED WARRANTIES INCLUDING BUT NOT LIMITED TO IWPLIED WARRANTIES OF MERCHANTABILITY AND FITNESSFOR A PARTICULAR PURPOSE SHALL NOT EXTEND BEYONDTHE DURATION OF THE EYPRESS WARRANTIES PROVIDED HEREIN Some states do notallow Ilmitationson how long an implied warranty lasts sotheabove limitation may no applytrusses/raftersloyou G Incidentalo,Consequential Damages SUN TEK SHALLNOT BELIABLEFOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES WHATSOEVER, INCLUDINC BUT NOTLIMITEDTOLOSSOFTIVEORREVENUE GASOLINE TELEPHONEGR OTHER EXPENSES Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you H Exclusive Warranty THIS WARRANTY IS EXCLUSIVE AND INc) if applicable, cut ceiling opening and build tunnel framing (See "LightLIEU OF ALL OTHER WARRANTIES This .arrant> g,es you speclfic legal rights Yol ma have other rights which q.ry from st,te to stateTunnel Installation Instructions")All installation information :,supplied,n good faith, but without recornmendation to Its use Noguaranteeof theresultsof anyuseof th,sinformation is to be implied, since conditionsof use are beyond our control Please consult local building codes for compliance before installing1283 IC2 - 6/16 5 Build curb:a) Construct curb with 2 x 4's, 2 x 6's, etc. (depending on height desired orbuilding code requirements). Curb should be minimum 4"high. Be sure insidemeasurement of curb is the same as roof opening measurement.b) Secure curb to roof. See fastener schedule and drawina.6 Shingle roof up to bottom of curb.7 Flash curb (sizes 2525,2549,3333,3349,4949 can be used with Sun Tek'spreformed, pre-cut Step Flash Kit withone-piece head and sill). Use galvanizedsheet metal, aluminum, or copper. Metalshouldextenda minimumof4 overshingles Ion bottom side), then up sidesof curb. Flashing should be flush withcurb top.8 shingle up sides and across the top.ªª19 Position the skylightover thecurb with the"THIS EDGE DOWN"label atthelowest side of the curb. Center the skylight over the curb, making sure the foamgasket is in contact with the top of the curb. As the fasteners, (see fastenerschedule),arebeing attached to the curb, push down on the frame just abovethe fastener to insure a good seal. Use the#12 x 2" screws, provided. Continueattaching the remaining fasteners in the same manner. All fastener installationholes provided must be used.5bcMG7 G6CMG-S THIS EDGE | 44 LioWN #j0.4"" lili1, , 15/8" plywooddeck3"#10 DECKSCREWX 23'" -411-32C VIG 11 FASTENER DRAWINGFASTENERS CURB TO DECKSee schedule for total number offosteners per side, Each siderequires o fastener Y from eachend, Additional fasteners to beequally spaced,#10 x 2 1/2« minimumSpacing not to exceed 14 7/8«.FASINERS SKYLGH" TO CURBSee schedule for total number offasteners per side, Each sidecequires a fastener 4' from eachend. Additional fasteners to beequally spaced. #12 x2' minimumSpacing not to exceed 15 5/8",40/,9Mwtv.:071 1}f#12 X 2" SHEET METAL SCREW\DESIGN PRESSURE RATINGt. 60. PSELARGE MISSLE IMPACT RESISTANCE2X CURB( BY OTHERS)4" -Engineer of Record:James D. Wells, Jr., P.E.Professional Engineer No. 53616J & L Wells Consulting LLC1453 Arbitus CircleOviedo, FL 32765(407) 496-5489Certificate ofAuthorization No. 27162