Loading...
HomeMy WebLinkAboutRoofing Permit Information Sheets. LUCIE WORKS r ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Ed-tian ('202.0) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 Asphaltic Shingles A, B, C A, B, D 2,4,5,6,7 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1, Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 v E. L.uk;1E WORKS Section A (General Information) Master permit No, Process No. contractors Name: COIIinS ROOfing Inc. /� r License # CCC 0 8011 �JobAddr.c� (Ati —T7it ^i—i7 � , — .i, ❑ Low Slope ROOF CATEGORY aechanically Fastened Tile ❑Asphaltic Shingles ❑Mortar/Adhesive Set Tiles etal Panel/Shingles OWood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE ❑ .� New roof ❑ Repair ❑ Maintenance '' Reroofing ❑Recovering ROOF SYSTEM INFORMATION �, Low Slope Roof Area (SF) % 0Steep Sloped Roof Area (SF) �'1�_ -7) Total (SFf Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. b �T. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Polyglass Product Approval No.: FL 1654 —YL-11 Design Wind Pressures, From RAS 128 Or Calculations: -53. 53.3 -74.4 -95.8 Zone 1': _ one 1: —'Zone 2: —Zone 3: _ Max. Design Pressure, from the specific product approval system: Deck: Type: Plywood 5/8" Gauge Thickness: Slope: 1-1/2 / 12 Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Polyglass SA-V & 1 Base Sheet Fastener/Bonding Material: Self -Adhesive Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: White Granular Surfaces Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':— " oc @ Lap, # Rows_ � — 0c Zone 1:—." oc @ Lap, # Rows — @ — oc Zone 2:_" oc @ Lap, # Rows — ®-- oc Zone 3:r." oc @ Lap, # Rows_ @ --" oc Number of Fasteners Per Insulation Board: Zone 11:—Zone 1:—Zone 2:—Zone 3:— Top Ply: Polyglass SEE -ro(M A'Q m c� Top Ply Fastener/Bonding Material: "iNr 01-) h�p I1P�1 Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof system Manufacturer Extreme Metal Fab Notice of Acceptance Number: FL 17023 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-ILZone 2e:-3'ELZone 2n:1-4..!'one 2r�'�JZone 3e:: 81.7 _Zone 3r: Deck Type: Roof Slope: Type Underlayment High TemplSelfAdhesive Underlayment ut ide 9ugy'l 12 Insulation: N/A Fire Barrier: I N/A Ridge Ventilation? N/A Mean Roof Height: 15 ft 1 Fastener Type & Spacing: #10x1.5"-12"x12" Pattern 16" o.c. (Wood Zac) Adhesive Type: I N/A \ Type Cap Sheet I N/A Roof Covering: 26 Ga. 5V Metal Roof Panels Type & Size Drip 2"x2" Galv. Steel Edge: