Loading...
HomeMy WebLinkAboutENGINEERINGCOVER PAGE PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US COVER PAGE SYSTEAD INFORADATION MODULE HANWHA Q.PEAK DUO BLK ML-G9+ 380 INVERTER ENPHASE IQ7PLUS-72-2-US RACKING SUNMODO EZ GRIP &ECOFASTENCLICKFITSYSTEM 2-RAIL SYSTEM SIZE (DC)11.02 KW LOCATION 27.3353320,-80.3307543 HANWHA Q.PEAK DUO BLK ML-G9+ 380 380 WATT MODULE 72.44'' X 40.5'' X 1.26''(SEE DATASHEET) BUILDING INFORMATION/B.O.M. # STORIES 1/15 ROOF AREA 2578.59 P.V. AREA 590 ROOFING TYPE CORRUGATED METAL ROOF PITCH 10 # RAILS 14 # L-FOOT ATTACHMENTS 54 # MODULES 29 # INVERTERS 29 # SKIRTS 0 # ENPHASE COMBINER BOXES 1 EATON 60A FUSIBLE SOLAR AC DISCONNECT 1 45A FUSES 2 125A LINE TAPS 2 PLAN KEY PV-1 COVER PAGE PV-2 SITE PLAN PV-3 PANEL SPECIFICATION PV-3.1 PANEL LOAD TESTING RESULTS PV-3.2 INVERTER SPECIFICATION PV-3.3 COMBINER BOX SPECIFICATION PV-3.4 JUNCTION BOX SPECIFICATION PV-3.5 ATTACHMENT DETAIL PV-3.6 STRUCTURAL CALCULATION PV-3.7 SEALANT SPECIFICATION PV-4 THREE LINE DIAGRAM PV-4.1 ELECTRICAL NOTES PV-4.2 EQUIPMENT LABELS PV-5 STRUCTURAL CERTIFICATION STRUCTURAL STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE SECTION 1512 THROUGH 1525 AND SECTION 1616 THROUGH 1626 FOR HIGH VELOCITY HURRICANE ZONES. GENERAL NOTES: THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE, 7TH EDITION 2020 FLORIDA FIRE PREVENTION CODE, NEC 2017 AND ALL LOCAL CODES & ORDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF FOR SLOPED ROOF AND NO MORE THAN 10-INCHES ABOVE THE SURFACE OF THE ROOF FOR FLAT ROOF. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF CHAPTER 471 ENGINEERING AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO THE DESIGN CONSTRUCTION OR ALTERATION OF BUILDINGS AND STRUCTURES FOR HUMAN HABITATION. INVERTER PLACEMENT: SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2020 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 1 / 14 SCALE: 1/8" = 1'-0" SITE PLAN PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US NOTE: 1. ROOF COVERING MATERIAL IS COMPOSED OF 2. EXACT ATTACHMENT LOCATION AND QUANTITY OF ATTACHMENTS ARE BASED ON EXISTING RAFTER LOCATIONS OBTAINED FROM FIELD MEASUREMENTS. . THE LOCATION AND QUANTITY OF ATTACHMENTS MAY VARY BASED ON RAFTER LAYOUT START POINT, SPACING VARIATIONS AND ROOFING TYPE. VERIFY IN THE FIELD ALL RAFTER LOCATIONS AND ADJUST LAYOUT AS REQUIRED. A TILE ROOF WILL PRODUCE A STAGERED ATTACHMENT LAYOUT BECAUSE OF EXISTING STAGERED TILE JOINT LOCATIONS 3. EXISTING RESIDENCE EQUIPPED WITH SMOKE/CO DETECTOR IN AND OUTSIDE OF ALL SLEEPING ROOMS HARDWIRED AND INTERCONNECTED AS PER FEDERAL LAW CORRUGATED METAL SITE PLAN SYMBOL LEGEND MAIN SERVICE PANEL UTILITY METER SKYLIGHT VENT CHIMNEY SUB-PANEL MSP SP M SOLAR AC DISC UDC LC N3R CB SOLAR AC DISCONNECT LOAD CENTER NEMA 3R BOX W/ ENVOY-S COMBINER BOX PIPE VENT FAN SATELLITE DISH MODULE FIRE SETBACKS PITCH DIRECTION UTILITY DISCONNECT MIN 3'x3' GROUND ACCESS POINT WIND PRESSURE ZONE LINES ROOF PANEL COUNT TILT AZIMUTH SHADING R1 29 10°271°95% RAFTER SPACING 24" O.C. (TYP) CLAMPING MAX SPACING IN ZONE 1 48" O.C AND IN ZONE 2 AND ZONE 3 24" O.CRIDGERIDGEGUTTER GUTTERGUTTERGUTTERGUTTERR1 J-BOX MSPM SOLAR AC DISC CB 58'-11 2" 58'-11 2" 59'-2"59'-2" 5'-9" 5'-9" 5'-9" 5'-9" 5'-9"5'-9" 5'-9" 5'-9" 5'-9" 5'-9" 5'-9" 5'-9" 5'-9"5'-9" 5'-9"5'-9" PZ1 PZ1 PZ3 PZ3 PZ3 PZ3 PZ3 PZ3 PZ3 PZ3 PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ1 PZ2e PZ2e PZ2e PZ2e PZ2e PZ2e PZ2e PZ2nPZ2n PZ2n PZ2n PZ2r PZ2r PZ2r PZ2r PZ2rPZ2r PZ2rPZ2r PZ3e PZ3e PZ3e PZ3e PZ3e PZ3r PZ3r PZ3rPZ3r FRONT OF RESIDENCECOCONUT AVENUE EASTDigitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 2 / 14 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US PANEL SPECIFICATION Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 3 / 14 PANEL LOAD TESTING RESULTS PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 4 / 14 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US INVERTER SPECIFICATION Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 5 / 14 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.3 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US COMBINER BOX SPECIFICATION Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 6 / 14 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.4 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US JUNCTION BOX SPECIFICATION ROOF JUNCTION BOX SPECIFICATION FOR LOW-SLOPE/TILE/METAL/CONCRETE ROOF Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 7 / 14 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.5 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US ATTACHMENT DETAIL ATTACHMENT DETAIL FOR CORRUGATED METAL ROOF REVISIONS REV A B DESCRIPTION INITIAL RELEASE ADD B15019-001 BY LWF LWF DATE 10/16/2018 10/24/2018 IN 1/2" PLYWOOD LOAD DIRECTION UPLIFT LATERAL.PERP. TO SLOT LATERAL.PARALLEL TO SLOT IN 7/16" OSB 5 4 LOAD DIRECTION UPLIFT LATERAL.PERP. TO SLOT LATERAL.PARALLEL TO SLOT NOTES * Factor of Safety as shown 3 * Torque at 3/8" T-Bolt = 15ft.lbs (20 N.m) * All loads in pounds force * Values valid only for conditons equal or better than test conditions * Values valid only when product is used in accordance with SunModo 7 2 installation instruction and other technical documentation * The kit as shown in the BOM. For alternative configurations, contact SunModo 4 1/4" Deck Screws in Min 7/16" OSB 8 B 1 B 6 8 B15019-001 7 B15018-001 6 C50001-001 5 B15003-001 4 B20007-002 3 A20062-001 2 B15039-001 1 A50224-001 ITEM MATERIAL PART NUMBER SEE NOTES Third Angle Projection: GENERAL SPECIFICATIONS All Dimensions in inches [millimeters] Tolerances X.XXX ±0.01 [0.25mm] X.XX ±0.02 [0.50mm] X.X ±0.039 [1.0mm] Unless otherwise spec'd DRAWN BY LWF THIS DRAWING IS CONFIDENTIAL PROPERTY OF SUNMODO AND ITS CONTENTS MAY NOT BE DISCLOSED WITHOUT THE PRIOR WRITTEN CONSENT OF SUNMODO CORP. CHECKED BY APPROVALS Break all sharp edges .010-.020 unless otherwise specified. DATE 10/16/2018 B SCALE: TITLE METAL ROOF DECK MOUNT KIT DRAWING NUMBER NONE K50532-001 STRUCTURE SHEET 1 of 1 SEALING WASHER .26 ID X .50 X .125 HEX CAP SCREW 3/8-16 X 3/4 GASKET, EPDM, WITH ADHESIVE FLANGE NUT 3/8-16 T-BOLT 3/8-16X1.0", 304 SS L FOOT HEX WASHER HEAD LAG BOLT 1/4X3 METAL ROOF DECK MOUNT DESCRIPTION SunModo Corp. 14800 NE 65TH STREET, VANCOUVER WA 98682 4 1 2 2 1 1 4 1 QTY FOS=2 345 140 265 FOS=2 190 125 135 FOS=3 230 95 175 FOS=3 125 85 90 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 8 / 14 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.6 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US STRUCTURAL CALCULATION 2-RAIL RACKING PLUS SOLAR SYSTEM DEAD LOAD COMPONENT WEIGHT/UNIT (LB)# MODULES 0 29 INVERTERS 4.0 29 RAILS (2-RAIL) @ 1.8LB/LF.1.8 14.0 ATTACHMENT/FLASHING 0.98 54 ARRAY TOTAL AREA (SQFT)590 ARRAY TOTAL WEIGHT (LB)194 TOTAL DEAD LOAD PER SF (LB/SQFT)2.60 10 % OF LEAST HORIZONTAL DIMENSION OR 40% OF THE BUILDING HEIGHT WHICHEVER IS SMALLER BUT NOT LESS THAN EITHER 4% OF THE LEAST HORIZONTAL DIMENSION OR 3'-0" WIND PRESSURE ZONE CALCULATION (ASCE FIGURE 30.4-2A, 2B) HORIZONTAL DIMENSION A 58.1199989318847'X 10% = 5.81199989318848' HORIZONTAL DIMENSION B 59.2000007629394'X 10% = 5.92000007629394' BUILDING HEIGHT 15'X 40% = 6' PRESSURE ZONE WIDTH 5' 9.74 " CERTIFICATION OF WIND LOAD PRESSURE CALCULATION THIS IS A 2-RAIL DESIGN DESIGN LOAD CRITERIA. AS PER ASCE 7-16 (2.4.1) FOR THIS PARTICULAR CASE, THE "DOWNFORCE" CASE 2 AND UPLIFT HAVE BEEN TAKEN INTO CONSIDERATION. P (PSF) = 1xD + 1x PNET (DOWNFORCE) P (PSF) = 0.6xD + 0.6x PNET (UPLIFT) (P = TOTAL DESIGN LOAD) (PNET = WIND LOAD) (D = DEAD LOAD) PNET HAVE BEEN CALCULATED FOLLOWING THE ALLOWABLE STRESS DESIGN METHOD. THE MAXIMUM ABSOLUTE VALUE OF THE 2 CASES IS THE UPLIFT LOAD. THIS 2-RAIL DESIGN IS WELL UNDER THE CAPACITY OF THE INDIVIDUAL ATTACHMENT CAPACITIES FOR THE DESIGN. THE PHOTOVOLTAIC MODULES USED IN CONJUNCTION WITH 2-RAIL ATTACHMENT SYSTEM ADDED HAVE A DESIGN CAPACITY OF -4,000 PA., 84 PSF. THIS DESIGN IS WITHIN THE LOADING CAPACITIES OF THE PHOTOVOLTAIC MODULE 2-RAIL DESIGN TESTING CAPACITIES THAT HAVE BEEN PERFORMED BY INDEPENDENT TESTING BY THE PANEL MANUFACTURERS ENGINEERS. SEE ATTACHED MANUFACTURERS TEST DATA. WIND LOAD CALCULATIONS (ASCE 7-16 EQ. 29.4-7) VELOCITY PRESSURE Qh = 0.00256 Kz*Kzt*Kd*Ke*V^2(LB/SQFT) (EQ. 26.10-1) EXPOSURE B V (WIND SPEED)175 MEAN HEIGHT 15.00 EFFECTIVE WIND AREA (AREA OF ONE PANEL)20.37 Kz (VELOCITY PRESSURE EXPOSURE)0.57 Kzt (TOPOGRAPHIC FACTOR)1 Kd (WIND DIRECTIONALITY)0.85 Ke (GROUND ELEVATION FACTOR)1 LF (LOAD FACTOR BASED ON ASD DESIGN)0.6 Qh (VELOCITY PRESSURE)22.98 ra (SOLAR PANEL PRESSURE EQUALIZATION FACTOR)0.68 TOTAL PRESSURE AND ATTACHMENT SPACING FOR GABLE ROOF WITH 7 to 20 DEGREE TILT GCp p- (LB/SQFT)p+ (LB/SQFT) pnet- (LB/SQFT)pnet+ (LB/SQFT) ATTACHMENT SPACING (INCH)UPLIFT PRESSURE FOR EACH ATTACHMENT (LB) ZONE UPLIFT DOWNWARD ARRAY INTERIOR ARRAY EDGE ARRAY INTERIOR ARRAY EDGE ARRAY INTERIOR ARRAY EDGE ARRAY INTERIOR ARRAY EDGE 1 -1.98 0.30 -30.82 -46.23 4.66 -16.93 -26.18 7.26 48.00 24.00 -204.41 -158.01 2e -1.98 0.30 -30.82 -46.23 4.66 -16.93 -26.18 7.26 24.00 24.00 -102.20 -158.01 2n -2.56 0.30 -39.76 -59.63 4.66 -22.29 -34.22 7.26 24.00 24.00 -134.58 -206.57 2r -2.56 0.30 -39.76 -59.63 4.66 -22.29 -34.22 7.26 24.00 24.00 -134.58 -206.57 3e -2.56 0.30 -39.76 -59.63 4.66 -22.29 -34.22 7.26 24.00 24.00 -134.58 -206.57 3r -3.04 0.30 -47.31 -70.96 4.66 -26.82 -41.02 7.26 24.00 16.00 -161.93 -165.07 WIND PRESSURE PNET IS CALCULATED BY ASCE 7-16 EQ. 29.4.7, WHERE Qh IS CALCULATED BY EQ. 29.4-7 (PARAMETERS SHOWN IN THE TABLE). GCp ARE CHOSEN FROM FIGURE 30.3-A-I FOR SPECIFIC ROOF TYPE AND ROOF TILT WITH EFFECTIVE WIND AREA EQUALS TO 10 SQFT (INTERPOLATION MAY REQUIRED). ARRAY EDGE FACTOR rE = 1.5 FOR ARRAY EDGES UPLIFT PRESSURE IF ARRAY EDGE IS MORE THAN 10 FEET (0.5h) TO ROOF EDGES AND MORE THAN 4 FEET TO ADJACENT ARRAY OR NEXT ADJACENT PANEL. rE = 1.0 FOR ARRAY INTERIOR UPLIFT PRESSURE AND ALL DOWNWARD PRESSURE AS DEFINED IN ASCE 7-16 29.4.4. NO PANEL ARE LOCATED IN ARRAY EDGE AREA AS DEFINED BY ASCE 7-16 29.4.4. FOR THIS PROJECT. ALLOWABLE LOAD / ATTACHMENT 5/16” LAG SCREW W/ 3.00” EMBEDMENT INTO RAFTER BELOW ACCORDING TO THE NATIONAL DESIGN SPECIFICIFICATION FOR WOOD CONSTRUCTION 2015 EDITION. = W' = W X CD X CT. - PER TABLE 11.3.1 NDS 5/16” DIA. 4" LONG LAG W/ 3.00” EMBEDMENT INTO 2X ROOF RAFTER W' = 266LB/IN (NDS11.3.1 TABLE 12.2A) FOR DF. LARCH, S.Y.P., AND S.P.F. SPECIES CD = 1.6 (TABLE 2.3.2 2015 NDS), CT = 1.0 (TABLE 10.3.4 2015 NDS) W' = 266LB/IN X 3.00” X 1.6 X 1.0 = 1,276.8LBS = ULTIMATE MAX ALLOWABLE UPLIFT PRESSURE WITH 60% OF ULTIMATE CAPACITY 1,276.8LBS X 0.6 = 766.08LBS -THREAD MUST BE EMBEDDED IN THE SIDE GRAIN OF A TRUSSES OR OTHER STRUCTURAL MEMBER INTEGRAL WITH THE BUILDING STRUCTURE. -LAG BOLTS MUST BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER. -THESE VALUES ARE NOT VALID FOR WET SURFACE. -INSTALL LAG BOLTS WITH HEAD AND WASHER FLUSH TO SURFACE (NO GAP). TORQUE AS PER MANUFACTURERS SPECIFICATIONS. DO NOT OVER-TORQUE. -WITHDRAWAL DESIGN VALUES FOR LAG SCREW CONNECTIONS SHALL BE MULTIPLIED BY APPLICABLE ADJUSTMENT FACTORS IF NECESSARY. SEE TABLE 10.3.1 IN THE AMERICAN WOOD COUNCIL NDS FOR WOOD CONSTRUCTION. Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 9 / 14 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.7 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US SEALANT SPECIFICATION SEALANT SPECIFICATION FOR CORRUGATED METAL ROOFS Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 10 / 14 ENPHASE 80A AC COMBINER BOX 10A/15A BREAKER (MANUFACTURER SUPPLIED FOR ENVOY) 20A BREAKER (A) 20A BREAKER (B) 20A BREAKER (C) 2A 2B 2C 3 GND NEU TERMINATION CAP INSTALLED ON END OF CABLE =...== INVERTERS INSTALLED ON RAIL SYSTEM =...== =...== 1A TO 1C ROOF JUNCTION BOX BRANCH CIRCUIT A 10 MICRO-INVERTERS BRANCH CIRCUIT B 10 MICRO-INVERTERS BRANCH CIRCUIT C 9 MICRO-INVERTERS 29 HANWHA Q.PEAK DUO BLK ML-G9+ 380 380W MODULES PAIRED WITH 29 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS GND BUS NEU BUS POWER GROUND EXISTING SQUARE D 200A MAIN SERVICE PANEL 240 V MAIN BREAKER: 150A 150A UTILITY METER GRID GND BUS NEU BUS POWER GROUND EXISTING SQUARE D 200A MAIN SERVICE PANEL 240 V MAIN BREAKER: 150A 150A UTILITY METER GRID GND NEU 4 EATON 60A FUSIBLE SOLAR AC DISCONNECT 45A 45A FUSES SOLAR CIRCUIT DISCONNECTING MEANS GND BUS NEU BUS POWER GROUND EXISTING SQUARE D 200A MAIN SERVICE PANEL 240 V MAIN BREAKER: 150A 150A UTILITY METER GRID PV SYSTEM CURRENT 43.8625 A SOLAR AC DISCONNECT EMPHASE COMBINER BOX EXISTING METER MSP LOCATED INSIDE OF STRUCTURE MSP METER RISER #2/0 AWG SERVICE CONDUCTOR FROM OVERHEAD FOR 200AMP SERVICE HOT LINE TAPS MINUMUM BEND RADIUS 4" ENCLOSURE DIMENSIONS LENGTH: 21.31" WIDTH:10.3" DEPTH:9.06" #2/0 AWG SERVICE CONDUCTOR FROM UTILITY METER FOR 200AMP SERVICE Wire Tag Conduit Wire Qty Wire Gauge Wire Type Temp. Rating Wire Ampacity (A) Temp. Derate Conduit Fill Derate Derated Ampacity (A) Inverter Qty NOC (A)NEC Correction Design Current (A) Ground Size Ground Wire Type 1A TO 1C OPEN AIR 3 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 10 1.21 1.25 15.13 06 AWG BARE CU 2A 3/4" PVC 6 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 10 1.21 1.25 15.13 08 AWG THWN-22B10 AWG THWN-2 75°C 35 0.96 0.8 26.88 10 1.21 1.25 15.13 2C 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 9 1.21 1.25 13.61 3 3/4" PVC 3 + G 08 AWG THWN-2 75°C 50 0.96 1 48.00 29 1.21 1.25 43.86 08 AWG THWN-2 4 3/4" PVC 3 + G 06 AWG THWN-2 75°C 65 0.96 1 62.40 29 1.21 1.25 43.86 THWN-2 THREE LINE DIAGRAM PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-4 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US ELECTRICAL SERVICE ELEVATION INTERCONNECTION DETAIL NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2020 SOLAR INSTALLER NOTES: 150AMP METER/RISER/FEEDER REPLACEMENT REQUIRED Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 11 / 14 ELECTRICAL NOTES SUB PANEL BREAKER SIZE # OF MODULES PV BREAKER PER BRANCH UP TO 16 20A PV ADODULE RATINGS MODULE MAKE HANWHA MODEL Q.PEAK DUO BLK ML-G9+ 380 MAX POWER 380W OPEN CIRCUIT VOLTAGE 45.04V MPP VOLTAGE 37.85V SHORT CIRCUIT CURRENT 10.5A MPP CURRENT 10.04A NUMBER OF MODULES 29 UL1703 COMPLIANT YES INVERTER RATINGS INVERTER MAKE ENPHASE MODEL IQ7PLUS-72-2- US MAX OUTPUT POWER 290W OPEN DC VOLTAGE 60V NOMINAL AC VOLTAGE 240V MAX AC CURRENT 1.21A CEC INVERTER EFFICIENCY 97% NUMBER OF INVERTERS 29 UL1703 COMPLIANT YES VOLTAGE DROP CALCULATIONS FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE WIRE RUN Vmp Imp R L (FT)Vo % Vo WIRE SIZE BRANCH TO J-BOX 240.00 J-BOX TO LOAD CENTER 240.00 LOAD CENTER TO AC DISCONNECT 240.00 AC DISCONNECT TO INTERCONNECTION 240.00 #NUM!1.98 #NUM!#NUM!#NUM!12 AWG 0 1.24 50.00 0.000 0.00%10 AWG 0 1.24 3.00 0.000 0.00%10 AWG 0 1.24 10.00 0.000 0.00%10 AWG PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-4.1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US MAKE MODEL VOLTAGE RATING CONDUCTOR RANGE MAIN CONDUCTOR RANGE TAP ILSCO IPC 4020 600 V 4/0-4 AWG 6-14 AWG ILSCO IPC 4006 600 V 4/0-2 AWG 2/0-6 AWG INSTRUCTIONS FOR LINE TAPS FIGURE 1: 1.ADJUST THE CONNECTOR NUT TO SUITABLE LOCATION 2.PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY 3.INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A CERTAIN LENGTH OF THE FIRST INSULATED LAY FROM INSERTED END 4.TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN SUITABLE LOCATION. 5.SCREW THE NUT WITH THE SLEEVE SPANNER. 6.SCREW THE NUT CONTINUALLY UNTIL THE TOP PART IS CRACKED AND DROPPED DOWN THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2020 FLORIDA BUILDING CODE AND THE 2017 NATIONAL ELECTRICAL CODE 1.ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE COEFFICIENTS. 2.THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING #6 BARE COPPER WIRE OR #8 THWN-2 COPPER WIRE. 3.THIS SYSTEM COMPLIES WITH NEC 2017 4.BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS SHALL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE COMBINER BOX SHALL BE SHOWN IN A SIMILAR FASHION 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C 7.INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8.CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9.EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10.ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(B) 11.PER NEC 690.13, 690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ *WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - OR EQUIVALENT. 12.PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13.INTERCONNECTION METHOD SHALL COMPLY WITH NEC705.12 14.AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB-CIRCUIT BRANCHES IS ACCEPTABLE. ELECTRICAL NOTES: 15.ALL CONDUCTORS MUST BE COPPER. 16.NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17.EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18.FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. 19.SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20.METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22.WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 23.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 24.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 25.TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(A)(2). 26.SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.6 - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. 28.CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. 690.6. 29.ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64. 30.NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.13, 690.15, 690.6. 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.12(A) OR 705.12(B) Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 12 / 14 ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING QUANTITY LOCATION A LABELTAG B C D E F 1 1 JUNCTION BOX INTERCONNECTION POINT 1 UTILITY METER 1 COMBINER BOX 1 1 AT ANY COMBINER BOX 1 AT ANY JUNCTION BOX 1 OF EACH AT FUSED AC DISCONNECT COMPLETE VOLTAGE AND CURRENT VALUES ON DISCONNECT LABEL 1 OF EACH AT BUILDING INTERCONNECTION POINT AND ONE DIRECTORY PLACARD 1 AT UTILITY METER AND ONE DIRECTORY PLACARD NOTE EXAMPLES A B D REVENUE METER C POWER TO THIS SERVICE IS ALSO SUPPLIED FROM ON-SITE SOLAR GENERATION AC SYSTEM DISCONNECT WARNING WARNING: PHOTOVOLTAIC POWER SOURCE PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 1 AC SOLAR VOLTAGE G 12 AC CONDUITS 1 AT EVERY SEPARATION BY ENCLOSURES / WALLS / PARTITIONS / CEILINGS / FLOORS OR NO MORE THAN 10' F G BACKFEED DUAL POWER SUPPLY SECONDARY SOURCE IS PHOTOVOLTAIC SYSTEM WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING NOMINAL OPERATING AC VOLTAGE : 240V NOMINAL OPERATING AC FREQUENCY : 60HZ MAXIMUM AC POWER : VA MAXIMUM AC CURRENT : 40A MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION : 20A AC CURRENT PV MODULES 1 BACKFEED PANEL H CAUTION CAUTION POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING PHOTOVOLTAIC SYSTEM INSTALLED BY MOMENTUM SOLAR 3096 B HAMILTON BLVD S. PLAINFIELD, NJ 07080 PHONE NUMBER:732-902-6224 TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN ENTIRE PV SYSTEM SOLAR ELECTRIC PV PANELS SECTIONS OF THE PV SYSTEM THAT ARE SHUT DOWN WHEN THE RAPID SHUTDOWN SWITCH IS OPERATED SECTIONS OF THE PV SYSTEM THAT ARE NOT SHUT DOWN WHEN THE RAPID SHUTDOWN SWITCH IS OPERATED EMERGENCY RESPONDER THIS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE A 240 V PHOTOVOLTAIC SYSTEM AC DISCONNECT AC DISCONNECT (RSD SWITCH) RAPID SHUTDOWN TO BE LOCATED AT AC DISCONNECT OUTSIDE THE HOUSE DUAL POWER SUPPLY SECONDARY SOURCE IS PHOTOVOLTAIC SYSTEM EQUIPMENT LABELS PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-4.2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 13 / 14 PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 3096 HAMILTON BLVD, SOUTH PLAINFIELD, NJ (732)902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-5 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING ERICH BARRANTES - MS93856 416 COCONUT AVENUE EAST PORT ST. LUCIE, FL 34952 3058969234 SN CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 2/10/2022 SYSTEM SIZE (DC ): 11.02 KW 29 MODULES: HANWHA Q.PEAK DUO BLK ML-G9+ 380 29 INVERTERS: ENPHASE IQ7PLUS-72-2-US STRUCTURAL CERTIFICATION Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2022.02.11 08:02:58 -05:00 Powered by TCPDF (www.tcpdf.org) 14 / 14