HomeMy WebLinkAboutVinyl Impact Single Hung WindowInstallation Notes:
1. Seal flange/frame to substrate.
2. Use #10 PH or greater fastener though the nail In with sufficient length to penetrate a minimum of 1
1/20 into the wood framing. For 2X wood frame substrate (min. S.G. = 0.42).
3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads
to the structure. The host structure is the responsibility of the architect or engineer of record for the
project of installation.
Digitally signed by Hermes F. Norero, P.E.
Reason:I am approving this document
Date: 2014.09.1916:25:32-04'00'
This schedule addresses only the fasteners required to anchor the
1t 11 1111111
window to achieve the rated design pressure up to the size limitations
/i�
noted. It is not intended as a guide to the Installation process and does
not address he sealing consideration that may arise in different wall
•.•'' •`• • • • %
conditions. For the complete installation procedure, see the instructions
r ; *
packaged with the window or go to
7
www.jeld-wen.com/resourcesfrnstallation.
* ,
DISCLAIMER:
This drawing and Its contents are confidential and are not to be
�,� '•, C p pP �:
reproduced or copied in whole or in part or used or disclosed to others
except as authorized by JELD-WEN Inc.
aee
1 va° MM EMBEDMENr
2 ZX WOOD FRAME
MM DISTANCE
FOR EDGEi 3/4'
v4° MAX 3
SHIM SPACE
Zmm
3mm 3mm
s�ss az'rE
GLAZING DETAIL.
FRAME SECTION (TYP)
VERTICAL SECTION
WMambft—"wFl."dW..aa+,mp
vW MAX
sHUA sPACE 3
MM WSTANCE
FOR EDGE: 3/4'
xx WOOD FRAME
EMBEDMENT
838
MIN. DISTANCE
FOR EDGE: 3/4'
xx woob R
FRAMES I
1 W MIN.
EMBEDMENT
NAIL FIN INSTALLATION
1/4' MAX
SHIM SPACE
JAMB SECTION (TYP)
HORIZONTAL SECTION
NOTE Cddk 6 ft=Nd1M9 Flanged Wdd Oped4
PREMIUM ATLANTIC VINYL SH WINDOW
Max Frame I DP RATING IMPACT
52 1/8 x 75 1 +50/-60 1 YES
LARGE MISSILE IMPACT
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria
of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida
Building Code (FBC) Including HVHZ and the industry requirement for the stated conditions.
2. AII glazing shall conform to ASTM E1300.
3. At minimum, glazing Is 3mm annealed -11mm airspace - 3mm annealed - 2mm PVB Interlayer by
DuPont - 3mm annealed.
4. Use structural or composite shims where required.
RWECr'ENGINEER: DATE; 08/13/2014 3737 Lakeport Blvd
--
)PAWN BY. soaEl bamath Falls, OIL 97601
D. Vezo NTS J Phone: (541) 882-3451
NEaW BY: nnE:
J. Kantola
WPROVEDBr: Premium Atlantic Vinyl Impact Single Hung Window
001-. 1OF3
Installation Notes:
1. Seal flange/frame to substrate.
2. Use 3116" ITW Tepcon or equivalent fasteners through frame with sufficient length to penetrate a
minimum of 1 114" Into concrete or masonry at each location with a 21/2" min from edge distance. For
concrete (min. Pc = 3000psi) or masonry substrate (CMU shall adhere to ASTM C90).
3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads
to the structure. The host structure is the responsibility of the architect or engineer of record for the
project of Installation.
This schedule addresses only the fasteners required to anchor the
to the design the limitations
I I I I I I I ���i
window achieve rated pressure up to size
�����,
noted. It Is not Intended as a guide to the installation process and does
%
not address he sealing consideration that may arise in different wall
��` Q' ,.�.G""' <
X.
conditions. For the complete installation procedure, see the Instructions
packaged with the window or go to
www.jeid-wen.comfresourceslinstalladon.
:.
DISCLAIMER
This drawing and Its contents are confidential and are not to be
reproduced or copied in whole or in part or used or disclosed to others
��, `P
except as authorized by JELD-WEN Inc.
BOB
MASONRY INSTALLATION
I v+" Mu.L
EMBECMIW
• V+' MAX
SMM WALE
AM DISTANCE 0 L
FMEWF.?.VY
MASONRY
eLocx �
JAMB SECTLON (1YP)
HORIZONTALSECTtON
PREMIUM ATLANTIC VINYL SH WINOOW
Max Frame I bP RATING IMPACT
52 1/8 x 75 1 +50/-60 1YES
LARGE MISSILE IMPACT
General Notes:
1. The product shown herein Is designed, tested and manufactured to comply with the wind load criteria
of the adopted Intemational Building Code(IBC), the International Residential Code(IRC), the Florida
Building Code (FBC) including HVHZ and the industry requirement for the stated conditions.
2. All glazing shall conform to ASTM El300.
3. At minimum, glazing is 3mm annealed -11 min airspace - 3mm annealed - 2mm PVB Interlayer by
DuPont - 3mm annealed.
4. Use structural or composite shims where required.
P=ECr ENGQiEEiL DATE:08/13/2014 IWT 3737 Lakeport Blvd
Iaamath Falls
D Vezo NTS� Phone: (541) 8--Z73451
CHECKED BY. TrrLE:
J. Kantola
APPROVED BY. Premium Atlantic Vinyl Impact Single Hung Window
is�Fw S8o IDENIIREP PLAM NM1E AND LOCATION: CAD DWG. Na.: REV: SHEEr
4� - NCTL210-3874 -FBC 00 2CF3
eaeays
1W OR-
MA1L nm
ern
A#
fe MA
Inm
CORKM
I--- _WWW wimp (sa I/e• iw
I ---�
TYPICAL ELEVATION WITH FASTENER SPACING
Installation Notes:
1. Seal flange/frame to substrate.
2. For anchoring into metal framing use #8 TEK Self Tapping screws with sufficient length to achieve a
minimum embedment of three threads past the frame thickness. Steel substrate min,18ga., fy = 33 ksi.
3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads
to the structure. The host structure is the responsibility of the architect or engineer of record for the
project of installation.
This schedule addresses only the fasteners required to anchor the
I I I I I I r
window to achieve the rated design pressure up to the size limitations
noted. It Is not intended as a guide to the installation process and does
—
not address he sealing consideration that may arise in different wall
conditions. For the complete installation procedure, seethe Instructions
��� ��c. , �..... ' • —<
••
; • �,�
packaged with the window or go to
www.jeid•wen.com/resourceslinstaliation.
* ,
DISCLAIMER:
T
•'•.,.
This drawing and its contents are confidential and are not to be�
O OP•'•
reproduced or copied in whole or in part or used or disclosed to others
a a x.
except as authorized by JELD-WEN Inc,
age E
STEEL INSTALLATION
16 gauge min
Steel Stud
1/4• MAX
SHIM SPACE
MIN. DISTANCE
FOR EDGE: 1/2"
Min. embedment
of three threads 3
past frame
1
JAMB SECTION (TYP)
HORIZONTAL SECTION
PREMIUM ATLANTIC VINYL SH WINDOW
Max Frame I DP RATING IMPACT
52 1/8 x 75 +50/-60 YES
LARGE MISSILE IMPACT
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria
of the adopted International Building Cods(IBC), the International Residential Cods(IRC), the Florida
Building Code (FBC) including HVHZ and the industry requirement for the stated conditions.
2. All glazing shall conform to ASTM E1300.
3. At minimum, glazing is 3mm annealed -11mm airspace - 3mm annealed - 2mm PVB Interiayer by
DuPont - 3mm annealed.
4. Use structural or composite shims where required.
MUM[ trdumtw
�O
DRAWN BY:
D. Vezo
J. Kantola
iZ r
APPROVED BY.
3813
IDENTIFIER No.
1/2014 3737 Lakeport Blvd
JMW1fJr Klamath Falls, OR. 97601
NTS Phone: (541) 882-3451
Premium Atlantic Vinyl Impact Single Hung Window
Na.: I REV. 00 I SHEET
30F3