Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING1/19/2021 Florida Building Code Online www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquFsbTbi%2b3jRWwJ%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA%3d%3d 1/3 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL13339-R8 Application Type Affirmation Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Attic Breeze Address/Phone/Email 1370 FM 116 Gatesville, TX 76528 (254) 865-9999 travis.hipp@atticbreeze.net Authorized Signature Travis Hipp travis.hipp@atticbreeze.net Technical Representative Travis Hipp Address/Phone/Email 1370 FM 116 Gatesville, TX 76528 (877) 288-4234 travis.hipp@atticbreeze.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report James L. Buckner, P.E. @ CBUCK Engineering Florida License PE-31242 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/01/2029 Validated By Michael John Riemer, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL13339_R8_COI_COI CertOf Indep James Buckner,P.E. sc.PDF Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1708.2 I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. 1/19/2021 Florida Building Code Online www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquFsbTbi%2b3jRWwJ%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA%3d%3d 2/3 Documentation from approved Evaluation or Validation Entity Yes No N/A FL13339_R8_COC_Affirmation_FL13339_ss.pdf Product Approval Method Method 2 Option B Date Submitted 11/04/2020 Date Validated 11/04/2020 Date Pending FBC Approval Date Approved 11/05/2020 Summary of Products FL #Model, Number or Name Description 13339.1 01_Solar Attic Fan Models AB-201A, AB-202A, AB-251A, AB-252A, AB-2022A, AB- 3022A & AB-4022A. Self-flashing, solar powered fan units, with solar panel directly attached to fan unit shroud/dome Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. Installation Instructions FL13339_R8_II_1-7_Attic Breeze-SPAF Panel Direct to Flush Mount Unit_EvalReport.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339_R8_AE_1-7_Attic Breeze-SPAF Panel Direct to Flush Mount Unit_EvalReport.pdf Created by Independent Third Party: Yes 13339.2 02_Solar Attic Fan Models AB-201D, AB-202D, AB-251D, AB-252D, AB-401, AB- 402, AB-2022D, AB-3022D & AB-4022D. Self-flashing, solar powered fan units, with solar panel(s) remotely attached from fan unit, using low profile mounting brackets Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. Installation Instructions FL13339_R8_II_2-7_Attic Breeze-SPAF Panel Remote to Low Profile_EvalReport.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339_R8_AE_2-7_Attic Breeze-SPAF Panel Remote to Low Profile_EvalReport.pdf Created by Independent Third Party: Yes 13339.3 03_Solar Attic Fan Models AB-201D, AB-202D, AB-251D, AB-252D, AB-401, AB- 402, AB-2022D, AB-3022D & AB-4022D. Self-flashing, solar powered fan units, with solar panel(s) remotely attached from fan unit, using universal mounting bracket Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. Installation Instructions FL13339_R8_II_3-7_Attic Breeze-SPAF Panel Remote Inclined_EvalReport.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339_R8_AE_3-7_Attic Breeze-SPAF Panel Remote Inclined_EvalReport.pdf Created by Independent Third Party: Yes 13339.4 04_Solar Attic Fan Models AB-601, AB-602 & AB-6022D. Self-flashing, solar powered fan units, with solar panel remotely attached from fan unit, using low profile mounting brackets Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. Installation Instructions FL13339_R8_II_4-7_Attic Breeze-SPAF Panel Remote to Low Profile_EvalReport.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339_R8_AE_4-7_Attic Breeze-SPAF Panel Remote to Low Profile_EvalReport.pdf Created by Independent Third Party: Yes 13339.5 05_Solar Attic Fan Models AB-601, AB-602 & AB-6022D. Self-flashing, solar powered fan units, with solar panel remotely attached from fan unit, using universal mounting brackets Limits of Use Approved for use in HVHZ: No Installation Instructions FL13339_R8_II_5-7_Attic Breeze-SPAF Panel Remote 1/19/2021 Florida Building Code Online www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquFsbTbi%2b3jRWwJ%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA%3d%3d 3/3 Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. Inclined_EvalReport.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339_R8_AE_5-7_Attic Breeze-SPAF Panel Remote Inclined_EvalReport.pdf Created by Independent Third Party: Yes 13339.6 06_Cardinal Ventilation Models CV-2000 & CV-3000. Self-flashing, circular shaped solar powered fan units, with solar panel directly attached to fan unit hood/dome Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. Installation Instructions FL13339_R8_II_6-7_AB-Cardinal SPAF Panel Direct to Flush Mount Unit_EvalReport.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339_R8_AE_6-7_AB-Cardinal SPAF Panel Direct to Flush Mount Unit_EvalReport.pdf Created by Independent Third Party: Yes 13339.7 Curb Mount Series Curb Profile vent fan base for attachment to roof curbs Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Installation Instructions FL13339_R8_II_7-7_Curb-SPA-CM-ER W 10.pdf Verified By: James L Buckner, P.E. @CBUCK, Inc P.E. # 31242 Created by Independent Third Party: Yes Evaluation Reports FL13339_R8_AE_7-7_Curb-SPA-CM-ER W 10.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Facsimile of digital copy signed by  James L. Buckner, P.E.   Electronically signed and sealed documents  shall  comply with the provisions of FAC Rule 61G15‐23. 2018.01.04 15:00:37 -05'00' Evaluation Report Curb Mount Profile Base Solar Powered Roof Ventilation Appendix A To Evaluation Reports: FL13339 .1 To .5 Manufacturer Attic Breeze, LLC. 1370 FM 116 Gatesville, Texas 76528 (877) 288-4234 for Florida Product Approval # FL 13339.7 R6 Florida Building Code 6th Edition (2017) Per Rule 61G20-3 Method: 2 - B Category: Roofing Sub - Category: Roofing Accessories that are an Integral Part of the Roofing System Product Name: Product Description: Curb Mount Curb Mount Series with Hood/Dome Mounted Solar Panel & Remote Mount Solar Panel Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Report No. 18-101-C-SPA-CM-ER Date: 1 / 4 / 17 Contents: Evaluation Report Pages 1 – 6 CBUCK, Inc. - Palm Beach County, Florida Phone: (561) 491-9927 · Email: cbuck@cbuckinc.net · Website: www.cbuckinc.net CBUCK Engineering Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 FL #: Date: Report No.: Page FL 13339.7 R6 1 / 4 / 18 18-101-C-SPA-CM-ER 2 of 6 CBUCK Engineering Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Manufacturer: Attic Breeze, LLC. Curb Mount Vent and Fan Base Models Roofing Roofing Accessories that are an Integral part of the Roofing System State Product Approval Rule 61G20-3.005 (2) (b) Curb profile vent fan base for attachment to roof curbs. Curb material is the same as the self flashing base in FL13339 Evaluation reports .1 to .5. Curb profile base attached to roof curb designed by others. This Appendix A is linked to FL13339 Reports .1 through .5 The vent units model numbers in this report are the same product specification in Reports .1 to .5 , including the same minimum base specifications. This report .7 includes additional model numbers. The envelope structural components are the same as previous reports. The differences are internal mechanical and/or electrical. This report addresses options for attaching the Curb Profile to roof curbs. Product Name: Product Category: Product Sub-Category Compliance Method: Product Description: Product Assembly as Evaluated: Appendix A Scope: Model Numbers Included in This Report: FL13339.7 AB-1020 AB-2042A AB-3042A AB-4042A AB-2042D AB-3042D AB-4042D AB-6042D FL #: Date: Report No.: Page FL 13339.6 R6 1 / 4 / 18 18-101-C-SPA-CM-ER 3 of 6 CBUCK Engineering Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Vent Unit Curb Base Support: Type & Minimum Strength Specification : Design of curbs is outside the scope of this evaluation (1) Wood Description: 15/32” or greater Plywood, or Wood (based on minimum density/specific gravity of0.42) (2) Steel Roof Slope: 22 gauge minimum thickness, 33 ksi minimum yield strength (3) Aluminum 1/8 inch minimum thickness, alloy 6063-T52 or 6063-T6 Slope shall be in compliance with FBC, Chapter 15 based on the type of roof covering. Allowable Wind Resistance: * Positive Design Pressure: + 115 PSF * Negative Design Pressure: - 115 PSF Performance: * Allowable design pressures for allowable stress design (ASD). Performance Standards: The following test protocol was performed to demonstrate compliance with the intent of the code as this product does not specifically addressed the performance standard in the code. • ASTM E330-02 – Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors and by Uniform Static Air PressureDifference Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 6th Edition (2017), Section 1708.2. FL #: Date: Report No.: Page FL 13339.6 R6 1 / 4 / 18 18-101-C-SPA-CM-ER 4 of 6 CBUCK Engineering Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Evaluation Report Scope: This product evaluation demonstrates compliance of this product with the structural wind load requirements of the Florida Building Code, as related to Florida Product Approval Rule 61G20-3.001. Limits of Use: • Scope of “Limitations and Conditions of Use” for this evaluation: This evaluation report for “Optional Statewide Approval” contains technical documentation, specifications and installation method(s) which include “Limitations and Conditions of Use” throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under “Optional Statewide Approval”. • Option for application outside “Limitations and Conditions of Use” Rule 61G20-3.005(1)(e) allows engineering analysis for “project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code”. Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. Design of support system is outside the scope of this report. Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof vent products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certification, Inc. (FBC Organization #: QUA 1824) FL #: Date: Report No.: Page FL 13339.6 R6 1 / 4 / 18 18-101-C-SPA-CM-ER 5 of 6 CBUCK Engineering Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Component(s) Material Standards: Vent Base Material Steel - Thickness: Yield Strength: Corrosion Resistance: 22 ga. 33 ksi Minimum Galvalume or Zincalume per ASTM A792 AZ 50 or in compliance with the FBC, Section 1507.4.3. Fastener for Wood Curb Type: Size: Standard: Corrosion Resistance: Pancake or Hex Head Wood Screw #10 × 1 in. Minimum Per ANSI/ASME B18.6.1 Per FBC Section 1506.6 . Fastener for Steel & Aluminum Curb Type: Size: Standard: Corrosion Resistance: Self Tapping or Self Drilling Screw #12 × 1 in. Minimum Per FBC Section 1507.4.4 and/or SAE J78-1979 Per FBC Section 1506.6 Evaluated Referenced Data: 1. ASTM E330-02 – Uniform Static Air Pressure Difference Test By Certified Testing Laboratories, Inc. (FBC Organization ID# TST 1577) Project #: CTLA 2002W, Dated: 11 / 20 / 09 2. Quality Assurance By Keystone Certification, Inc. (FBC Organization ID# QUA 1824) Attic Breeze, LLC. Licensee #740 3. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 4. Engineering Analysis By CBUCK Engineering Report #17-144-EA, Dated: 6 / 11 / 17 FL #: Date: Report No.: Page FL 13339.6 R6 1 / 4 / 18 18-101-C-SPA-CM-ER 6 of 6 CBUCK Engineering Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation Methods Attic Breeze, LLC. Solar Powered Roof Vent Attachment To Curbs Attach to Wood Curb: Option to attach vertical leg or horizontal flange. Screw: pancake head or hex head minimum #10 x 1 inch 3 screw on each side for a minimum total of 12. Maximum spacing of 12 inches on center and within 6 inches of corners minimum distance to base edge 1 inch Attach to Steel (22 gauge min.) or Aluminum ( 1/8 in min.) Curb: Option to attach vertical leg or horizontal flange. Screw: pancake head or hex head minimum #10 x 1 inch 3 screws on each side for a minimum total of 12. Maximum spacing of 12 inches on center and within 6 inches of corners minimum distance to base edge 1 inch Refer to manufacturer's installation instructions as a supplemental guide for attachment.