HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING1/19/2021 Florida Building Code Online
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquFsbTbi%2b3jRWwJ%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA%3d%3d 1/3
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL13339-R8
Application Type Affirmation
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Attic Breeze
Address/Phone/Email 1370 FM 116
Gatesville, TX 76528
(254) 865-9999
travis.hipp@atticbreeze.net
Authorized Signature Travis Hipp
travis.hipp@atticbreeze.net
Technical Representative Travis Hipp
Address/Phone/Email 1370 FM 116
Gatesville, TX 76528
(877) 288-4234
travis.hipp@atticbreeze.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
James L. Buckner, P.E. @ CBUCK Engineering
Florida License PE-31242
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/01/2029
Validated By Michael John Riemer, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL13339_R8_COI_COI CertOf Indep James Buckner,P.E. sc.PDF
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1708.2
I affirm that there are no changes in the new Florida Building
Code which affect my product(s) and my product(s) are in
compliance with the new Florida Building Code.
1/19/2021 Florida Building Code Online
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquFsbTbi%2b3jRWwJ%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA%3d%3d 2/3
Documentation from approved Evaluation or Validation Entity Yes No N/A
FL13339_R8_COC_Affirmation_FL13339_ss.pdf
Product Approval Method Method 2 Option B
Date Submitted 11/04/2020
Date Validated 11/04/2020
Date Pending FBC Approval
Date Approved 11/05/2020
Summary of Products
FL #Model, Number or Name Description
13339.1 01_Solar Attic Fan Models AB-201A, AB-202A, AB-251A, AB-252A, AB-2022A, AB-
3022A & AB-4022A. Self-flashing, solar powered fan units, with
solar panel directly attached to fan unit shroud/dome
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
Installation Instructions
FL13339_R8_II_1-7_Attic Breeze-SPAF Panel Direct to Flush
Mount Unit_EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339_R8_AE_1-7_Attic Breeze-SPAF Panel Direct to Flush
Mount Unit_EvalReport.pdf
Created by Independent Third Party: Yes
13339.2 02_Solar Attic Fan Models AB-201D, AB-202D, AB-251D, AB-252D, AB-401, AB-
402, AB-2022D, AB-3022D & AB-4022D. Self-flashing, solar
powered fan units, with solar panel(s) remotely attached from
fan unit, using low profile mounting brackets
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
Installation Instructions
FL13339_R8_II_2-7_Attic Breeze-SPAF Panel Remote to Low
Profile_EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339_R8_AE_2-7_Attic Breeze-SPAF Panel Remote to Low
Profile_EvalReport.pdf
Created by Independent Third Party: Yes
13339.3 03_Solar Attic Fan Models AB-201D, AB-202D, AB-251D, AB-252D, AB-401, AB-
402, AB-2022D, AB-3022D & AB-4022D. Self-flashing, solar
powered fan units, with solar panel(s) remotely attached from
fan unit, using universal mounting bracket
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
Installation Instructions
FL13339_R8_II_3-7_Attic Breeze-SPAF Panel Remote
Inclined_EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339_R8_AE_3-7_Attic Breeze-SPAF Panel Remote
Inclined_EvalReport.pdf
Created by Independent Third Party: Yes
13339.4 04_Solar Attic Fan Models AB-601, AB-602 & AB-6022D. Self-flashing, solar
powered fan units, with solar panel remotely attached from fan
unit, using low profile mounting brackets
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
Installation Instructions
FL13339_R8_II_4-7_Attic Breeze-SPAF Panel Remote to Low
Profile_EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339_R8_AE_4-7_Attic Breeze-SPAF Panel Remote to Low
Profile_EvalReport.pdf
Created by Independent Third Party: Yes
13339.5 05_Solar Attic Fan Models AB-601, AB-602 & AB-6022D. Self-flashing, solar
powered fan units, with solar panel remotely attached from fan
unit, using universal mounting brackets
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL13339_R8_II_5-7_Attic Breeze-SPAF Panel Remote
1/19/2021 Florida Building Code Online
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquFsbTbi%2b3jRWwJ%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA%3d%3d 3/3
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
Inclined_EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339_R8_AE_5-7_Attic Breeze-SPAF Panel Remote
Inclined_EvalReport.pdf
Created by Independent Third Party: Yes
13339.6 06_Cardinal Ventilation Models CV-2000 & CV-3000. Self-flashing, circular shaped solar
powered fan units, with solar panel directly attached to fan unit
hood/dome
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use. Refer to manufacturer's installation instructions as a
supplemental guide.
Installation Instructions
FL13339_R8_II_6-7_AB-Cardinal SPAF Panel Direct to Flush
Mount Unit_EvalReport.pdf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339_R8_AE_6-7_AB-Cardinal SPAF Panel Direct to Flush
Mount Unit_EvalReport.pdf
Created by Independent Third Party: Yes
13339.7 Curb Mount Series Curb Profile vent fan base for attachment to roof curbs
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and conditions
of use.
Installation Instructions
FL13339_R8_II_7-7_Curb-SPA-CM-ER W 10.pdf
Verified By: James L Buckner, P.E. @CBUCK, Inc P.E. # 31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339_R8_AE_7-7_Curb-SPA-CM-ER W 10.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Facsimile of digital copy signed by
James L. Buckner, P.E.
Electronically signed and sealed documents shall
comply with the provisions of FAC Rule 61G15‐23.
2018.01.04 15:00:37 -05'00'
Evaluation Report
Curb Mount Profile Base
Solar Powered Roof Ventilation
Appendix A
To Evaluation Reports: FL13339 .1 To .5
Manufacturer
Attic Breeze, LLC.
1370 FM 116
Gatesville, Texas 76528
(877) 288-4234
for
Florida Product Approval
# FL 13339.7 R6
Florida Building Code 6th Edition (2017)
Per Rule 61G20-3
Method: 2 - B
Category: Roofing
Sub - Category: Roofing Accessories that are an Integral
Part of the Roofing System
Product Name:
Product Description:
Curb Mount
Curb Mount Series
with Hood/Dome Mounted Solar Panel
& Remote Mount Solar Panel
Prepared by:
James L. Buckner, P.E., SECB
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Report No. 18-101-C-SPA-CM-ER
Date: 1 / 4 / 17
Contents:
Evaluation Report Pages 1 – 6
CBUCK, Inc. - Palm Beach County, Florida
Phone: (561) 491-9927 · Email: cbuck@cbuckinc.net · Website: www.cbuckinc.net
CBUCK Engineering
Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
FL #:
Date:
Report No.:
Page
FL 13339.7 R6
1 / 4 / 18
18-101-C-SPA-CM-ER
2 of 6
CBUCK Engineering
Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Manufacturer: Attic Breeze, LLC.
Curb Mount Vent and Fan Base Models
Roofing
Roofing Accessories that are an Integral part of the Roofing System
State Product Approval Rule 61G20-3.005 (2) (b)
Curb profile vent fan base for attachment to roof curbs. Curb material is the
same as the self flashing base in FL13339 Evaluation reports .1 to .5.
Curb profile base attached to roof curb designed by others.
This Appendix A is linked to FL13339 Reports .1 through .5
The vent units model numbers in this report are the same product specification
in Reports .1 to .5 , including the same minimum base specifications.
This report .7 includes additional model numbers. The envelope
structural components are the same as previous reports. The differences
are internal mechanical and/or electrical.
This report addresses options for attaching the Curb Profile to roof curbs.
Product Name:
Product Category:
Product Sub-Category
Compliance Method:
Product Description:
Product Assembly as
Evaluated:
Appendix A Scope:
Model Numbers
Included in This Report:
FL13339.7
AB-1020
AB-2042A
AB-3042A
AB-4042A
AB-2042D
AB-3042D
AB-4042D
AB-6042D
FL #:
Date:
Report No.:
Page
FL 13339.6 R6
1 / 4 / 18
18-101-C-SPA-CM-ER
3 of 6
CBUCK Engineering
Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Vent Unit Curb Base Support: Type & Minimum Strength Specification :
Design of curbs is outside the scope of this evaluation
(1) Wood
Description:
15/32” or greater Plywood, or
Wood (based on minimum density/specific gravity of0.42)
(2) Steel
Roof Slope:
22 gauge minimum thickness, 33 ksi minimum yield strength
(3) Aluminum
1/8 inch minimum thickness, alloy 6063-T52 or 6063-T6
Slope shall be in compliance with FBC, Chapter 15 based on the type of roof covering.
Allowable Wind Resistance:
* Positive Design Pressure: + 115 PSF
* Negative Design Pressure: - 115 PSF
Performance:
* Allowable design pressures for allowable stress design (ASD).
Performance Standards:
The following test protocol was performed to demonstrate compliance with the
intent of the code as this product does not specifically addressed the performance
standard in the code.
• ASTM E330-02 – Standard Test Method for Structural Performance of Exterior
Windows, Curtain Walls, and Doors and by Uniform Static Air PressureDifference
Code Compliance: The product described herein has demonstrated compliance with the Florida
Building Code 6th Edition (2017), Section 1708.2.
FL #:
Date:
Report No.:
Page
FL 13339.6 R6
1 / 4 / 18
18-101-C-SPA-CM-ER
4 of 6
CBUCK Engineering
Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Evaluation Report Scope:
This product evaluation demonstrates compliance of this product with the structural
wind load requirements of the Florida Building Code, as related to Florida Product
Approval Rule 61G20-3.001.
Limits of Use:
• Scope of “Limitations and Conditions of Use” for this evaluation:
This evaluation report for “Optional Statewide Approval” contains technical
documentation, specifications and installation method(s) which include
“Limitations and Conditions of Use” throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under “Optional Statewide Approval”.
• Option for application outside “Limitations and Conditions of Use”
Rule 61G20-3.005(1)(e) allows engineering analysis for “project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code”. Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the responsibility
of others.
Design of support system is outside the scope of this report.
Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance:
The manufacturer has demonstrated compliance of roof vent products in accordance
with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a
quality assurance program audited by an approved quality assurance entity through
Keystone Certification, Inc. (FBC Organization #: QUA 1824)
FL #:
Date:
Report No.:
Page
FL 13339.6 R6
1 / 4 / 18
18-101-C-SPA-CM-ER
5 of 6
CBUCK Engineering
Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Component(s)
Material Standards:
Vent Base
Material Steel
- Thickness:
Yield Strength:
Corrosion Resistance:
22 ga.
33 ksi Minimum
Galvalume or Zincalume per ASTM A792 AZ 50
or in compliance with the FBC, Section 1507.4.3.
Fastener for Wood Curb
Type:
Size:
Standard:
Corrosion Resistance:
Pancake or Hex Head Wood Screw
#10 × 1 in. Minimum
Per ANSI/ASME B18.6.1
Per FBC Section 1506.6
. Fastener for Steel & Aluminum Curb
Type:
Size:
Standard:
Corrosion Resistance:
Self Tapping or Self Drilling Screw
#12 × 1 in. Minimum
Per FBC Section 1507.4.4 and/or SAE J78-1979
Per FBC Section 1506.6
Evaluated Referenced Data: 1. ASTM E330-02 – Uniform Static Air Pressure Difference Test
By Certified Testing Laboratories, Inc. (FBC Organization ID# TST 1577)
Project #: CTLA 2002W, Dated: 11 / 20 / 09
2. Quality Assurance
By Keystone Certification, Inc. (FBC Organization ID# QUA 1824)
Attic Breeze, LLC. Licensee #740
3. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
4. Engineering Analysis
By CBUCK Engineering
Report #17-144-EA, Dated: 6 / 11 / 17
FL #:
Date:
Report No.:
Page
FL 13339.6 R6
1 / 4 / 18
18-101-C-SPA-CM-ER
6 of 6
CBUCK Engineering
Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Installation Methods
Attic Breeze, LLC.
Solar Powered Roof Vent Attachment To Curbs
Attach to Wood Curb:
Option to attach vertical leg or horizontal flange.
Screw: pancake head or hex head minimum #10 x 1
inch 3 screw on each side for a minimum total of 12.
Maximum spacing of 12 inches on center
and within 6 inches of corners
minimum distance to base edge 1 inch
Attach to Steel (22 gauge min.) or Aluminum ( 1/8 in min.) Curb:
Option to attach vertical leg or horizontal flange.
Screw: pancake head or hex
head minimum #10 x 1 inch
3 screws on each side for a minimum total of 12.
Maximum spacing of 12 inches on center
and within 6 inches of corners
minimum distance to base edge 1 inch
Refer to manufacturer's installation instructions as a supplemental guide for attachment.