HomeMy WebLinkAboutslabŠ Š Š Š Š Š ŠŠ VALID FOR 1 PERMIT ONLY U.N.O.REMARKSDRWNCHKDDATESCALE: COPYRIGHT ENGINEERING EXPRESSŠC:\Users\colby\Engineering Express\Production - Documents\Projects\21-36079 Precast Pads - 32x54x4\WP\Drawings & CAD\21-36079b - Precast Pads 32x54x4 Foam Core Pad.dwg03/11/2021 - 2:26pmcolbyINIT ISSUE (19-16293)LOFLB10/14/192020 FBCCCBFLB1/15/21PRECAST PADS FOAM CORE CONCRETE GENERATOR PAD 32 X 54 x 4 IN, FOAM CORE (341 LB MIN) (ON-GRADE APPLICATIONS ONLY) STEP 1: DETERMINE WIND VELOCITY PER LOCATION, RISK, AND EXPOSURE NOTE: TABLE ABOVE INCLUDES A QUICK REFERENCE OF COMMON FLORIDA CONDITIONS (AT ULTIMATE DESIGN WIND VELOCITIES) FOR SITE-SPECIFIC CONDITIONS, CONSULT LOCAL BUILDING MUNICIPALITY. MAXIMUM DESIGN WIND PRESSURES AT GRADE PER SPECIFIED EXPOSURE REMAIN CONSTANT FOR ANY MAX WIND VELOCITY. FOR SITE-SPECIFIC WIND VELOCITY AND PRESSURE CONVERSIONS, SEE QR LINK PROVIDED BELOW. STEP 2: DETERMINE CONCRETE PAD PER ALLOWABLE WIND PRESSURE DESIGN NOTES 1.THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SIXTH & SEVENTH EDITION (2017 & 2020). 2.POSITIVE AND NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED BY OTHERS ON A JOB-SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. 3.MAXIMUM DIMENSIONS AND WEIGHT OF GENERATORS UNIT SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. 4.THE AREA UNDER CONCRETE SLAB ON GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. THESE CONCRETE PADS HAVE BEEN DESIGNED FOR A MINIMUM BEARING CAPACITY OF 2,000 PSF AND MINIMUM SUBGRADE MODULUS = 100 PCI. SHOULD OTHER CONDITIONS OR MATERIALS BE ENCOUNTERED, THE ENGINEER OF RECORD SHALL BE NOTIFIED PRIOR TO PROCEEDING WITH THE WORK. 5.SLIDING IS ASSUMED RESISTED BY 2" EMBEDMENT OF PAD IN GROUND ALONG WITH RESISTANCE FROM CONNECTED CABLING. NOMIAL SLIDING IS NOT ASSUMED A FAILURE CASE IN THIS DESIGN 6.ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 7.ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN.15. 8.HOLLOW PADS FOR USE WHERE APPLICABLE BY CODE. USE OF PADS MAY BE SUBJECT TO BUILDING DEPT APPROVAL 9.WATER-TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER-TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 10.THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 11.THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR-SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 12.EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB-SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE-SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE POSITIVE OR NEGATIVE DESIGN PRESSURE "ASD" CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. ALLOWABLE DESIGN PRESSURE VISIT ECALC.IO/36079 FOR ENGINEER CERTIFIED ORIGINALS & MORE INFORMATION ABOUT THIS DOCUMENT OR SCAN THIS QR CODE VISIT ENGINEERINGEXPRESS.COM/PRECASTPADS FOR ADDITIONAL PLANS, REPORTS & RESOURCES GENERAL NOTES GENERATOR UNIT BY SEPARATE SUBMITTAL (SEE TABLE FOR MINIMUM WEIGHT & SIZE REQUIREMENTS) ASCE 7-10 & 7-16 ULT WIND VELOCITY TO ASD DESIGN PRESSURE AT GRADE CONVERSION CHART - HVHZ OR NON HVHZ EXAMPLE COUNTY RISK EXPOSURE RISK EXPOSURE RISK EXPOSURE I C D II C D III, IV C D FORT MYERS 145 MPH 29.4 PSF 35.6 PSF 160 MPH 35.8 PSF 43.4 PSF 175 MPH 42.8 PSF 51.9 PSF PALM BEACH 150 MPH 31.5 PSF 38.1 PSF 170 MPH 40.4 PSF 49.0 PSF 180 MPH 45.3 PSF 54.9 PSF BROWARD 156 MPH 34.0 PSF 41.2 PSF 170 MPH 40.4 PSF 49.0 PSF 180 MPH 45.3 PSF 54.9 PSF MIAMI-DADE 165 MPH 38.1 PSF 46.1 PSF 175 MPH 42.8 PSF 51.9 PSF 186 MPH 48.4 PSF 58.6 PSF MONROE 175 MPH 42.8 PSF 51.9 PSF 180 MPH 45.3 PSF 54.9 PSF 200 MPH 55.9 PSF 67.8 PSF Kz (Exp C/D) (Table 26.10-1) =0.85 1.03 Kd (Table 26.6-1) =0.9 G (Section 26.11) =0.85 Kzt (Section 26.8.2) =1.0 Ke (Section 26.9) =1 Cf (Table 29.4-1) =1.4 TABLE 2.1: CONCRETE PAD INFORMATION PRECAST PADS MODEL L, IN W, IN H, IN WT, LB 32 X 54 x 4, FOAM CORE 32 54 4 341 TABLE 2.2: ALLOWABLE LATERAL ASD PRESSURE FOR PAD / GENERATOR COMBINATION BRAND CAPACITY MODEL L, IN W, IN H, IN WT, LB ALLOWABLE ASD PRESSURE EQUIVALENT WIND EXP C EXP D GENERAC 10 KW 005871 & 005883 25.0 48.0 28.8 387 44.4 PSF 175 MPH 160 MPH 14 KW 005872 & 005884 25.0 48.0 28.8 439 47.6 PSF 180 MPH 165 MPH 16 KW 7035, 7036, 7037 25.0 48.0 28.8 406 45.5 PSF 180 MPH 160 MPH 16 KW 007176 & 7178 25.5 48.5 28.6 420 46.5 PSF 180 MPH 165 MPH 16 KW 006721 25.0 48.0 28.8 448 48.1 PSF 180 MPH 165 MPH 16 KW 6459, 6461, 6462 25.0 48.0 28.8 513 52.1 PSF 190 MPH 175 MPH 17 KW 005874 & 005886 25.0 48.0 28.8 421 46.5 PSF 180 MPH 165 MPH 17 KW 005873 & 005885 25.0 48.0 28.8 455 48.5 PSF 186 MPH 165 MPH 18 KW 007226 & 007228 25.0 48.0 29.0 420 45.8 PSF 180 MPH 160 MPH 20 KW 007038 & 007039 25.0 48.0 28.8 448 48.1 PSF 180 MPH 165 MPH 20 KW 005875 & 005887 25.0 48.0 28.8 451 48.3 PSF 180 MPH 165 MPH 20 KW 006729 & 006730 25.0 48.0 28.8 516 52.3 PSF 190 MPH 175 MPH 22 KW 007042 & 7043 25.0 48.0 28.8 466 49.2 PSF 186 MPH 170 MPH 22 KW 006551 & 006552 25.0 48.0 28.8 526 52.9 PSF 190 MPH 175 MPH 24 KW 007209 & 7210 25.0 48.0 29.0 455 47.9 PSF 180 MPH 165 MPH KOHLER 14 KW 14RCA 26.2 47.0 32.2 440 39.4 PSF 165 MPH 150 MPH 14 KW 14RCAL 26.2 47.0 32.2 490 41.9 PSF 170 MPH 156 MPH 20 KW 14RES & 20RES 26.0 48.0 28.8 500 51.3 PSF 190 MPH 170 MPH 20 KW 20RCA 26.2 47.0 32.2 555 45.2 PSF 175 MPH 160 MPH 20 KW 20RCAL 26.2 47.0 32.2 600 47.5 PSF 180 MPH 165 MPH NOTES: 1- CONCRETE PADS WEIGHT CALCULATED PER STANDARD WEIGHT CONCRETE (150 PCF) 2- MIN REQUIRED WEIGHTS LISTED. REFER MANUFACTURER SPECS FOR SPECIFIC MODEL WEIGHT 3- CONCRETE MIN COMPRESSIVE STRENGTH TO BE f'c=6,000 PSI AT 28 DAYS. 4- UNITS NOT SHOWN ARE RATED TO EQUIVALENT PRESSSURES GIVEN EQUAL SIZE & EQUAL OR GREATER WEIGHT. FOR UNITS OR CONDITIONS REQUIRING GREATER ALLOWABLE PRESSURE, LARGER PAD OR ADDITIONAL ANCHORAGE MAY BE REQUIRED. CL GENERATOR (SEE CONCRETE PAD SCHEDULE FOR DIMENSIONS & WEIGHT REQUIRED)HEIGHTCL 4" 54" LENGTH32" WIDTHHEIGHT PAD SIDE VIEW PAD FRONT VIEW WIND LOAD RESULTANT 12 UNIT HEIGHT +12 SLAB HEIGHTGRADE 54" LENGTH32" WIDTHCONCRETE PAD GENERATOR PAD DIMENSIONS: PLAN VIEW (OPTIONAL GENERAC PRE-DRILLED ANCHOR LAYOUT SHOWN) REFER ANCHOR SCHEDULE FOR ALTERNATE MINIMUM ANCHOR REQUIREMENTS 17.98"20.51"10.43"‘$1&+25 LOCATION 1.05" 7.74" 4" MIN2" MIN CONCRETE PAD 54" 2" MIN50" GROUND 1" MIN PAD SECTION VIEW W6 X W6 / W1.4 X 1.4 MESH MIN LENGTH PAD LEN G T HHEIGHTPAD THICKNESS WI D T H PA D W I D T H ISOMETRIC VIEW GENERATOR GENERATOR ATTACHMENT BASE, VARIES WITH MODEL SEE GENERATOR SPECS OPTIONAL RUBBER VIBRATION PAD SEE ANCHOR SCHEDULE 2"x3"x3 8" GALV. STEEL WASHER FOAM CORE 4"2"2"Y XCONCRETE PAD 6,000 PSI CONCRETE MIX GENERATOR Z GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF-DRILLING SCREWS TO GENERATOR (SEE GENERATOR SPECS) GENERATOR MOUNTING CONFIGURATION: NOTES: 1.Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2". 2.X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3.Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS 3 8" THICK GALVANIZED WASHER& RUBBER VIBRATION PAD CONCRETE PAD 6,000 PSI CONCRETE MIX W6 X W6 / W1.4 X 1.4 MESH MIN  ‘'(:$/7 SCREW BOLT OR EQUIVALENT, 1.5" FULL EMBED TO CONCRETE, 3" MIN. EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. ANCHOR TO PAD SCHEDULE: NOTES: 1.ANCHOR QUANTITY PER LONG SIDE 2.EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, IF APPLICABLE. 3.ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 4.ENSURE MINIMUM SPACING TO ANY ADJACENT ANCHORS. 5.FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS TO INSTALL ANCHORS. CONCRETE: (6000 PSI MIN.) SUBSTRATE DESCRIPTION VALID ONLY FOR ZIP CODE: 34986 VALID ONLY FOR BELOW COMPANY: Energized Electric FOR PERMIT USE WITHIN 14 DAYS OF DIGITAL SEAL 86488 CA-9885 | 02/04/2022