Loading...
HomeMy WebLinkAboutProduct Approval - Roofing� -'���1�4i Product Approval `.:rtiUSER: Public User _ter - jol Product Approval Menu > Product or Application Search > Application List > Application Detail OW4 FL # FL16952-R1 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer American Metals Supply, Inc. Address/Phone/Email 3119 Queen Palm Dr. Tampa, FL 33619 (813) 242-8100 Santos.Gonzatez@americanmetals.us Authorized Signature Santos Gonzalez Santos. Gonzalez@a mericanmetals, us Technical Representative Address/Phone/Emall Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing FBC Staff BCIS Site Map Links Search I)EC 1 3 201? R-ER."All7iidCs 5t. Lucie Oounj, FL Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Do Kim Report Florida License PE-49497 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By lames L. Buckner, P.E. @ CBUCK, Inc. °°' Validation Checklist - Hardcopy Received Certificate of Independence FL16952 R1 C01 certificate of independence.odf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By a Sections from the Code y j 1504 7 1507.4 1609 2002.4 Product Approval Method Method 2 Option B i• 6Date Submitted 10/30/2015 Date Validated 10/30/2015 Date Pending FBC Approval 11/04/2015 Date Approved 12/15/2015 1 FL # ;Description ... _..... .... ....... _............................. - .... -................. -- - ---._._._._.._........._.........._..._._._..... - ..._...)t ...— — - - ......_... -- ------ 16952.1 3" Riser Aluminum Roof Panels 10.024" and 0.030" thick x 3" x 12" wide riser roof panels https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvBwYu9TrZNm9sRhczFZg8OEz8Yl2zTMKu8D068ZcFIMQ%3d%3d 1/2 11/30/2017 Florida Building Code Online - \ Y I Limits of use Installation Instructl" i Approved for use In HVHZ: No -_�' F I'g 2 RI II 2014 : •r2.1 3 Inch Riser Pan Install Dwg.pdf Approved for use outside HVHZ: Yes Verified By: Do Kim PE 49497 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +48.6/-48.6 Evaluation Reports Other: For use in outdoor patio construction only. See Installation instructions for i FL16952 RI AE 2014 AMS Evaluation Reoort.odf other design limitations. I Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: eChsct Credit. i sale securitym https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvBwYu9TrZNm9sRhczFZg8OEz8Yl2zTMKu8D068ZcFIMQ%3d%3d 2/2 Q�lD�A11�1 AMERICAN METALS SUPPLY - ALUMINUM ROOF PANELS li�flLLllll 1I✓�rNN1111 3119 Queen Palm Dr. MEMLS, Tampa, FL 33619 Sone r / (813) 242-8100 LOCK PANELS TO INSTALL 3" RISER ROOF PANELS. Exposure B JASCE 7-10 Ultimate Design Pressure Span Table OPEN STRUCTURES Wind Speed Design Pressure 0.024" span (ft) 0.030" span (ft) 110 18.4 10.00 12.00 120 23-2 9.95 12.00 130 24.8 9.40 12.00 140 28.8 8.87 11.58 150 33.0 8.17 11.11 160 37.5 7.68 8.50 Exposure B JASCE 7-10 Ultimate Design Pressure Span Table ENCLOSED ATTACHEDI STRUCTURES Wind Speed Design Pressure 0.024" span (ft) 0.030" span (ft) 110 19.0 10.00 12.00 120 22.6 9.68 12.00 130 26.5 9.19 11.83 140 30.8 8.53 11.36 150 35.3 7.88 8.81 160 40.2 7.44 8.11 PRODUCT APPROVAL DETAILS: • BLDG CODE: 2014 FLORIDA BUILDING CODE • HVHZ: NOT FOR USE IN HVHZ • LIMITS OF USE: FOR PATIO USE ONLY. -CARPORTS -PATIO COVERS -SUNROOMS -SCREEN ENCLOSURES -CANOPIES -OTHER SIMILAR MINOR STRUCTURES Notes: I. Aluminum roof panels shall be of aluminum alloy 3105-H I or approved equal. 2. Roof panel metal thickness tested: 0.024" and 0.030". 3. Product materials conform to ASTM B209. 4. S. All inside bend radii are 0.047 unless otherwise noted. Standard Manufacturing Tolerances: Dimension + / - 0.005 Radius -1 .005 Angle +/- /° .o 6. Product test report for 0.030" and 0.024" Thickness Rolled 3" Riser Roof Pancls, Test Report No.: E9946.01-40144, Oct. 2, 2015. ASTM E3301E33OM-14. Architectural Testing, Inc. an Intertek company, 2250 Massaro Blvd., Tampa, FL 33619. 7. All product performance specifications and construction requirements shall be engineered by a L licensed design professional in accordance with the Aluminum Design Manual, Specifications & Guidelines for Aluminum Structures, Washington, DC, for wind resistance in conformance to FBC Chapter 16 for Components and Cladding Loads. ASCE 7-10 Chapter 30 for Roof Components and Cladding for Enclosed and Open Structures. Effective area for wind load calculations based on 36 sq. feet (absolute value of controlling design pressure is shown on span tables). 8. Span schedule show maximum roof panel spans between supports. Max, span deflection limit L/60. 9. Mean roof height of structure shall not exceed 15 feet above grade. Span tables for open structures based on 5° max, roof slope. Span tables for enclosed structures based on 27e max. roof slope. 10. Each roof panel shall be connected per design professional's instructions, but shall have min. of (3)4i 10 SMS w/neoprene gasket and washer at each support point (or other approved connection by design professional) w/ min. 0.040" thick, 6063-T6 aluminum base metal. Exposure C ASCE 7-10 Ultimate Design Pressure Span Table OPEN STRUCTURES Wind Speed Design Pressure 0.024" span (ft) 0.030" span (ft) 110 22.2 9.73 12.00 120 25.0 9.38 1200 130 30.0 8.67 11.44 140 34.8 7.93 9.89 150 39.9 7.46 8.16 160 45.4 1 6.94 7.45 Exposure C ASCE 7-10 Ultimate Design Pressure Span Table ENCLOSED ATTACHED STRUCTURES Wind Speed Design Pressure 0.024" span (ft) 0.030" span (ft) 110 23.0 9.63 12.00 120 27.3 9.09 11.74 130 32.1 8.32 11.21 140 37.3 7.70 8.53 150 42.7 7.21 7.79 160 48.6 6.49 7.05 D❑ KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO BOX 10039 Tampa, FL 33679 Re jw a Description n '- iss-W 3 x� H� c I 1 co O a O� ❑. of 0 2 d J O QO� to aFx Z aU 5 op _ ~ � P P a aato w0X W (0 mX0 Z U p i 02 3nr✓1d I6�d�� aidAE. BECleflppMBER d�d9 * DO KIM IAT�9 11''CAM 7 O TaaMtmFL 33679, -15 Drawing No. -140316 SHEET 1OF1 DO Kim & ASSO0IATE89 LLC CONSULTING STRUCTURAL ENGINEERS Florida Board of Engineers Certificate of Authorization No. 26887 Product Evaluation Report Date: October 27, 2015 Report No.: 152710.1 FL Product Approval t FL# 16952 Product Category: Roofing Product sub -category: Metal Roofing Product Name: 3" Aluminum Riser Roof Panel Manufacturer: American Metal Supply, Inc. 3119 Queen Palm Dr. Tampa; FL 33619 Phone:8.13.242.8100 Fax:813.242.8110 Scope: This product evaluation report issued by Do Kim and Associates, LLC and Do Kim, P.E. for American Metal Supply, Inc. and is based on Florida Department of Business. and Professional Regulation Rule 61 G20-3, Method (2) (b) of the State of Florida Product Approval. Re-evaluation of this product shall be required following pertinent Florida Building Code modifications or updates. Do Kim and Associates, LLC and Do Kim, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in theapprovalprocess of the product named herein. This product has been evaluated for use in locations adhering to the Florida Building Code, 51h Edition (FBC) and where pressure and deflection requirements, as determined by Chapter 1.6 of the Florida Building Code, do not exceed the design pressures as shown on the approval. Digitally signed by Do Kim, P.E. Date: 201°5:0.30 14:2.156-04'00' 10-27-15 Do Kim, P.E. FL #49497 P.O. Box 10039 Tampa, FL 33679 dk@dokimengineering.net 813.857.9955 Sheet 1 of 2 DO Kim & ASSOCIATES, LLC CONSULTING STRUCTURAL ENI3INEERS Supporting Documents 1. Product Approval Installation Drawings: a. Drawing No. 140316 titled "3" RISER ROOF PANELS", Sheet 1 of 1, prepared by Do Kim & Associates, LLC signed and sealed by Do Kim, P.E (FL PE# 49497). 2. Testing: a. Testing per ASTM E330/E330M-14, Test Report No.: E9946.01-401.44, Report Date: 10/02/15, 3" Riser Pan Series, 0.030" and 0.024" Thickness Rolled Formed Aluminum Roof Panel rendered to American Metals Supply, Inc,,, Tampa, FL by Architectural Testing, Inc., an Intertek Company ("Intertek-ATI"), 2250 Massaro Blvd., Tampa,_.FL 33619. 3. Engineering Analysis/Calculations: a. Comparative and rational analysis has been conducted for allowable span conditions. based on minimum and maximum boundary span testing. b. Rational analysis has been performed per FBC requirements as listed in the product application and acceptable standards of engineering principles. 4. Quality Assurance Entity: a. Letter of Participation issued by PRI Construction Materials Technologies, LLC. (FBC Organization Number QUA9110) confirms that .this manufacturer is within a quality assurance program for this product under Rule 61G20-3.008 (5). Limitations and Condition of Use 1. This product has not been tested for Impact Resistance. 2. This product has been not been evaluated for use within the High Velocity Hurricane Zone (HVHZ). 3. This product has been designed to resist wind loads as indicated in the design schedules. on the Product Evaluation Documents and Installation Drawings. 4. The product listed above shall conform to and be in strict compliance with all requirements and limitations as described in this Product Evaluation Report and in the Installation Drawings. All product components shall be of the material specified in the Product Evaluation Documents and Installation Drawings. 5. Refer to Product Approval Installation Drawings noted above for: • All supporting host structures shall be designed to resist all superimposed loads and shall be of a material listed in this product's respective anchor schedule. Host structure conditions which are not described in this product's anchor details shall be designed for on a site -specific basis by a registered design professional. • All components which are permanently installed shall be protected against corrosion, contamination, and other such damage at all times per FBC. • Material fabrication, properties, and performance parameters. 6. Linear interpolation may be used for figures shown in all tables. Do Kim, P.E. FL #49497 P.O. Box 10039 dk@dokimetigineering.net Tampa, FL 33679 813.857.9955 Sheet 2 of 2