Loading...
HomeMy WebLinkAboutProduct Approval Metal Roof 12-11-17i iviijo vullutily %�iJut: vnune w y pi BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search F� ridgy .. Product Approval iUSER: Public User Product Approval Menu > Product or Application Search > Application Lis[ > Application Detail .ow ".- FL q a s Application Type u - - Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL # I Model, Number or Name 16952.1 3" Riser Aluminum Roof Panels FL16952-R1 Revision 2014 Approved American Metals Supply, Inc. 3119 Queen Palm Dr Tampa, FL 33619 (813) 242-8100 Santos. Gonzalez@americanmetals. us Santos Gonzalez Santos.Gonzalez@america nmetals, us Roofing Metal Roofing )�g�a, its 1)EC I1 12017 F+,Rge n-TjidCa 5t. Lucie Comity, FL Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer - Evaluation Report - Hardcopy Received Do Kim PE-49497 PRI Construction Materials Technologies, LLC 12/31/2020 James L. Buckner, P.E. @ CBUCK, Inc. Validation Checklist - Hardcopy Received FL16952 R1 COI certificate of indeoend nce odf 1504 1507.4 1609 2002.4 Method 2 Option B 10/30/2015 10/30/2015 11/04/2015 12/15/2015 Description ..._........ .......................... ........................"............................................................................._........._ 0.024" and 0.030" thick x 3" x 12" wide riser roof panels https://www.fl6ridabuilding.org/prlpr_app dtl.aspx?param=wGEVXQwtDgvBwYu9TrZNm9sRhczFZg80Ez8Yl2zTMKu8DO68ZcFIMOa/`3da/n3d 1ro riuriutl Duuuuly t-,oae unnne Limits of Use I Approved for use In HVH2: Nr Installation Instru(; FL16952 Rl II 2Q1 %4MS 13 Inch Riser Pan Install Dwa odf • Approved for use outside HVG,. �,s Verified By: Do Kim 'r —;s�A7 j Impact Resistant: N/A Created by Independent Third Party: Yes ' Design Pressure: +48.6/-48.6 : Evaluation Reports Other: For use in outdoor patio construction only. See Installation instructions for € FL16952 RI AE 2014 AMS Evaluation Reportodf other design limitations. i Created by Independent Third Party: Yes :_- .... _............ -.......................... _.................... -............. _.................. .._._._..-- Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487.18 4 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibillty Statement :: Refund Statement Under. Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S„ please click here . Product Approval Accepts: ro -.,y ® EChtCk 11 CreditCard Safe SL-'curifi'ML"I'R ICS' https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwlDgvBwYu9TrZNm9sRhczFZoBC)F7RYl97Tnnkj iRn0AQ'7.clnnno/,),4o,e)a AEfl�IiH AMERICAN METALS SUPPLY - ALUMINUM ROOF PANELS //��Q` 3119 Queen Palm Dr. r6r+y��+ Tampa, FL 33619 �7, F. � � (813) 242-8100 LOCK PANELS TO INSTALL i r / .. .. __ t� Ky: .. . %A_; r so.ci 7 3" RISER ROOF PANELS Exposure B JASCE 7-10 Ultimate Design Pressure Span Table OPEN STRUCTURES 0.024" span (ft) 0.030" span (ft) Wind Speed Design Pressure 110 18.4 10.00 12.00 120 21.2 9.85 12.00 130 24.8 9.40 12.00 140 28.8 8.87 11.58 150 33.0 8.17 11.11 160 37.5 7.68 g50 ltimate Design Pressure Span Table SED ATTACHED STRUCTURES Pressure 0.024" span (ft) 0.030"span (ft) 19.0 "15035.3 10.00 12.00 22.6 9.68 12.00 26.5 9.19 11.83 0.8 8.53 11.3635.3 7.88 8.81 160 40.2 7.44 8.11 PRODUCT APPROVAL DETAILS: • BLDG CODE: 2014 FLORIDA BUILDING CODE. • HVHZ: NOT FOR USE IN HVHZ D ❑ K I M & ASSOCIATES. LLC, • LIMITS OF USE: FOR PATIO USE ONLY. -CARPORTS ! CONSULTING STRUCTURAL -PATIO COVERS ENGINEERS -SUNROOMS -SCREEN ENCLOSURES -CANOPIES • PO Box ,om9 i•enp. FL 33679 -OTHER SIMILAR MINOR STRUCTURES Notes: Rra�I=o�scp�b� I. Aluminum roof pancls shall be of aluminum alloy 3105-141 or approved equal. j /�� �ssuED 2. Roof panel metal thickness tested: 0.024" and 0.030". ,^,; _-^ 3. Product materials conform to ASTM B209. ;A' 4. All inside bend radii arc 0.047 unless otherwise noted. 5. Standard Manufacturing Tolerances: Dimension + / _ 0.005 n. Radius -A .005 i Angle+i /° -A: i 6. Product test report for 0.030" and 0.024" Thickness Rolled 3" Riser Roof Panels, Test Repon No.: F.9946.01-40144, Oct. 2, 2075. ASTM F.330/E330M-14. Architectural Testing. Inc. an Intertek ^ I < company, 2250 Massaro Blvd., Tampa, FL 33619. J 7. All product performance specifications and construction requirements shall be engineered by a � licensed design professional in accordance with the Aluminum Design Manual, Specifications & = m Guidelines for Aluminum Structures. Wm'kington. DC, for wind resistance in conformance to FBC Chapter 16 for Components ' c � W and Cladding Loads. ASCE 7-10 Chapter 30 for Roof Components and: - _ Cladding for Enclosed and Open Structures. Effective area for wind load calculations based on 36 a Co O sq. feet (absolute value ofcontrolling design pressure is shown on span tables). 0- ro 8. Span schedule show maximum roof panel spans between supports. Max. span deflection limit U60. :3 ; U) ir 0 M 9. Mean roof height of stmcmrc shall not exceed 15 feet above grade. Span tables for open structures ! =° Cf) > based on 5° max. roof slope. Span tables for enclosed structures based on 27' max. rout slope. ! g Lu Oto 10. Each roof panel shall be connected per design protessional's instructions, but shall have min. of Q O_ w (3 }k W SMS w/neoprene gasket and washer at each support point or other approved connection by PPo Po ( i .c3 Co Z u_ ~ F- design professional) w/ min. 0.040" thick, 6063-T6 aluminum bast metal. - � d a U O a 0 E F O�� ExposureC ASCE 7-10 Ultimate Design Pressure Span Table OPEN STRUCTURES 0.024" span (ft) 0.030" span (ft) Wind Speed Design Pressure 110 22.2 9.73 12.00 120 25.0 9.38 12.00 130 30.0 8.67 11.44 140 34.8 7.93 8.89 150 39.9 7.46 8.16 260 45.4 6.94 7.45 Exposure C ASCE 7-10 Ultimate Design Pressure Span Table STRUCTURES Wind Speed24" span (ft) 0.030" span (ft) 1109.63 12.00 1209.09 MENICLOSEDHED 11.74 1308.321407.7ISO7.21 779 160 8 6 Q d d' F- i- ZU tY tr ,n rWn(L0 I LD a)E X U ui U - �oruwHBv; CHECKEDBr: DYv.. YSCALE_ -- -ASr . DAi E: 1N'. Jro eq/c ,aoa9 w yKtYl4fl 3i6r9=rG ' �C OR101 .15 rDrawing No.-140316 __.SHEET 1 OF 1 D.O Kim & ASSOCIATESt LLC CONSULTING STRUCTURAL ENGINEERS Florida Board of Engineers Certificate of Authorization No, 26887 Product Evaluation Report Date: October 27, 2015 Report No.: . 152710.1 FL Product Approval #: FL# 16952 Product Category: Roofing Product sub -category: Metal Roofing Product Name: 3" Aluminum Riser Roof Panel Manufacturer: American Metal Supply, Inc. 3119 Queen Palm Dr. Tampa, FL 33619 Phone: 813.242.8 100 Fax:813.242.8110 Scope: This product evaluation report issued by Do Kim and Associates, LLC and Do Kim, P.E. for American Metal Supply, Inc. and is based on Florida Department of Business and Professional Regulation Rule 61020-3, Method (2) (b) of the State of Florida Product Approval. Re-evaluation of this product shall be required following pertinent Florida Building Code modifications or updates. Do Kim and Associates, LLC and Do Kim, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Florida Building Code, 5`h Edition (FBC) and where pressure and deflection requirements, as determined by Chapter 16 of the Florida Building Code, do not exceed the design pressures as shown on the approval. r_r.11r.t�. ,. Y O Digitally signed by Do Kim, P.E. Date:2015.10.30 a - 14:21:56-04'00' �•. {TATE OF .Q, . OR 10-27-15 Do Kim, P.E. FL #49497 P.O. Box 10039 Tampa, FL 33679 dk@dokimengineering.net dokimengineering.net 813.857.9955 Sheet I of 2 Dc3 Kim & ASSOCIATES9 LLC CONSULTING STRUCTURAL ENGINEERS Supportins? Documents 1. Product Approval Installation Drawings: a. Drawing No. 140316 titled "3" RISER ROOF PANELS", Sheet l of 1, prepared by Do Kim & Associates, LLC signed and sealed by Do Kim, RE (FL PE# 49497). 2. Testing: a. Testing per ASTM E330/E330M-14. Test Report No.: E9946.01-401.44, Report Date: 10/02/15, 3" Riser Pan Series, 0.030" and 0.024" Thickness Rolled Formed Aluminum Roof Panel rendered to American Metals Supply, Inc., Tampa, FL by Architectural Testing, Inc., an Intertek Company ("Intertek-ATI"), 2250 Massaro Blvd., Tampa, FL 33619. 3. Engineering Analysis/Calculations: a. Comparative and rational analysis has been conducted for allowable span conditions based on minimum and maximum boundary span testing. b. Rational analysis has been performed per FBC requirements as listed in the product application and acceptable standards of engineering principles. 4. Quality Assurance Entity: a. Letter of Participation issued by PRI Construction Materials Technologies, LLC. (FBC Organization Number QUA9110) confirms that this manufacturer is within a quality assurance program for this product under Rule 61 G20-3.008 (5). Limitations and Condition of Use 1. This product has not been tested for Impact Resistance. 2. This product has been not been evaluated for use within the High Velocity Hurricane Zone (HVHZ). 3. This product has been designed to resist wind loads as indicated in the design schedules on the Product Evaluation Documents and Installation Drawings. 4. The product listed above shall conform to and be in strict compliance with all requirements and limitations as described in this Product Evaluation Report and in the Installation Drawings. All product components shall be of the material specified in the Product Evaluation Documents and Installation Drawings. 5. Refer to Product Approval Installation Drawings noted above for: • All supporting host structures shall be designed to resist all superimposed loads and shall be of a material listed in this product's respective anchor schedule. Host structure conditions which are not described in this product's anchor details shall be designed for on a site -specific basis by a registered design professional. • All components which are permanently installed shall be protected against corrosion, contamination, and other such damage at all times per FBC. • Material fabrication, properties, and performance parameters. 6. Linear interpolation may be used for figures shown in all tables. Do Kim, P.E. FL #49497 P.O. Box 10039 dk@d'okimengineering.net Tampa, FL 33679 813.857.9955 Sheet 2 of 2