Loading...
HomeMy WebLinkAboutWind Speed & Exposure.L CONTRACTOR: East Coast Alumini ?oducts, Inc. DESIGN CRITERIA: Applicable Codes, Regulations, and Standards 1. The Sth Edition (2014) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2010 Edition and the Guide to Aluminum Construction in high wind areas, 2010. 3. ASCE 7-10. 4. Scope of Work: Does not include analysis of existing structure. Wind Loads 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category 1. 2. Basic Wind Speed, Figure 1609C, State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: VuLT =150 MPH, VASD =116 MPH 3. Exposure Category, Paragraph 1609.4.3: Exposure C 4. Building Category for Aluminum Structures, Paragraph 2002.6: Building Category 1- Roof - Replacement Scope of Work: Replacement of roof only. Does not include analysis of existing structure. Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.024" composite panel Elite 2000,1.0 density foam, Florida Product Approval Number FL 7561-R3. Foundation Design N/A Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the 5th Edition (2014) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, -signed and sealed authorization of Suncoast Aluminum Engineering, LLC. 3. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 4. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or # 12 screws 6" from ends and 12" center to center. 5. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1 % - ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: L Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after batching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 6. All flashing and weatherproofing shall be provided by the contractor. 7. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEED AND EXP- `! RE HAVE BEEN DETERMINED U,--, THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. r 0 1 0 �I�- 8'-6" �I� T in I Go 2X3KB EXISTING CARPORT EXISTING FRAMING TO REMAIN 13'-0" 4TH WALL THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO C0161PLY WITH ALL APPLICABLE CODES. CONCEALED FASTENEfS coFar�cro� OF �FA �rPv 401i� 13'-0" 3"X48"XO.024" 1.0 DENSITY FOAM COMPOSITE PANEL fJ 18'-0" so! E COMPOSITE PANEL rat M I 00 O I N T i .......... ���Ci. �• 2�i ¢� o lob',= W v 4f, ¢ 0:Z= c� a Nc�: 0Z ; IAP PRO ESSI�I L SEAL \\\ ST. MCM, CoUN REVIEWED FOR C® IANCE REVIEWED BY DATE 2 r PLANS AND PERIIIT'MUST BE KEPT ON JOB OR NO INSPECTION WILL BE _MADE. ELITE 2000 COMPOSITE PANEL. A: FL CI-R3 150MPH/EXP C ( , ®1? 3"x48"xO.024" (1.0# DENSITY FOAM) MAX SPAN: q-ri, = W-3r o ED ❑ CC ui Ld OVLLI a a �cn -o LL Z W C) cc .. 0 OC co _m W d? -i LLI z p z 0Z aZ Z s= OM w oc- Z •, U S J C7 Q_ G Z Z^gGo O Lu A A U WN-N Z 5 Z MU� tN W u N LU W 0 pW Q 0 U J pv~iRl-v �Uc�nOJ a.LucnaW DRAWN BY MC DATE DRAWN 10/31/17 REVISION Q 12/06/17 SHEET NO: A-1