HomeMy WebLinkAboutGenerator Product Information & Specifications20/22/24 kW
MEN__
INCLUDES:
• True Power'" Electrical Technology
s Two-line multilingual digital LCD Evolution" controller
(Eng I ish/Spanish/French/Portuguese)
• 200 amp service rated transfer switch available
• Electronic governor
0 Standard Wi-Fi® connectivity
• System status & maintenance Interva€ LED indicators
• Sound attenuated enclosure
s Flexible fuel line connector
s Natural gas or LP gas operation
0 5 Year limited warranty
• Listed and labeled by the Southwest Research Institute allowing
installation as close as 18 in (457 mm) to a structure.*
"Must be located away from doors, windows, and fresh air intakes and in
accordance with local codes.
hltps,-Ilassets.swri.org//ibraryIDirectoiyOfListedProducts/
Constructioolndustry/973_DoC 204_13204-01-07_Rev9.pdf
FEATURES
O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen-
erac's success in providing the most reliable generators possible. Generac's G-
Force engine lineup offers added peace of mind and reliability for when it's needed
the most. The G-Force series ergfnes are purpose built and designed to handle the
rigors of extended run times in high temperatures and extreme operating conditions.
O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
form produce less than 5% Total Harmonic Distortion for utility quality power. This
allows confident operation of sensitive electronic equipment and micro -chip based
appliances, such as variable speed HVAC systems.
O TEST CRITERIA:
✓ PROTOTYPE TESTED ✓ NEMA l i-22 EVALUATION
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY
O MOBILE LINV' CONNECTIVITY: FREE with select Guardian Series Home standby
generators, Mobile Link Wi-Fi allows users to monitor generator status from any-
where in the world using a smartphone, tablet, or PC. Easily access information such
as the currert operating status and maintenance alerts. Users can connect an
account to an authorized service dealer for fast, friendly, and proactive service. With
Mobile. Link, users are taken care. of before the next power outage.
GENERAL"
GUARDIAN' SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW 60 Hz
3007042-2, G007043-2, G007042-3, G007043-3 (Aluminum - Bisque) - 22 kW 60 Hz
G007209-0, G007210-0 (Aluminurn - Bisque) - 24 kW 60 Hz
01%
or C V0 uSnu! cus LISTED `j(
Nate: GETL or CUL certification only applies to unbundled units and units packaged
with limited circuit switches. Units packaged with the Smart Switch are ETL or UL
certified in the USA only.
O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
state-of-the-art power maximizing regulation system is standard on all Generac mod-
els. It provides optimized FAST RESPONSE to changing load conditions and MAXI-
MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge
loads tone engine, Digital voltage regulation at ±1 %,
O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network
provides parts and service know-how for the entire unit, from the engine to the small-
est electronic component.
O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with
GENERAC POWER SYSTEMS. One reason for tl ss confidence is that the GENERAC
product kne is offered with its own transfer systems and controls for total system
compatibility.
O PWRVIi TRANSFER SWITCH: The Generac PWtiview Automatic Transfer
Switch integrates the PWRview energy monitor to provide real-time energy con-
sumption data that can help lower a home's electricity bill. Using a convenient
mobile app, homeowners can access energy usage and alert information while under
utility power ar generator power. The PWRview energy monitor is a simple to use and
low cost tool which helps save money over the life of the generator. Included with
model G007210-0.
w GENERAC GEN— E�:
PROMISE Q
e� � PWR
GENERAC®
20/22/24 kW
Features and Benefits
Engine
• Generac G-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
rings help tirc engine run cooler, reducing oil consumption and resulting in longer engine life.
• "Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine lite.
• Electronic ignition/spark advance
These teatures combine to assure smooth, quick starting every time.
• Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine
life. Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown
Prevents damage due to overheating.
Generator
•
Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
•
Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•
Displaced phase excitation
Maximizes motor starting capability.
•
Automatic voltage regulation
Regulating output voltage to ±1 % prevents damaging voltage spikes.
•
UL 2200 listed
For your safety.
Transfer Switch (if applicable)
•
Fully automatic
Transfers vital electrical loads to the energized source of power.
•
NEMA 3R
Can be installed inside or outside for maximum flexibility.
•
Integrated load management technology
Capability to manage additional loads for efficient power management.
•
Remote mounting
Mounts near an existing distribution panel for simple, low-cost installation.
PWRview Transfer Switch (if applicable)
•
PWRview energy monitor
Energy usage at -a -glance.
•
Abilityto view real-time energy consumption data
Better understand the home's energy profile.
•
PWRview mobile app
Access daily energy intelligence and insights.
Evolution" Controls
•
AUTG/MANUAUOFF illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
•
Two-line multilingual LCD
Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.
•
Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
•
Utility voltage sensing
Constantly monitors utility voltage, setpeints 65% dropout, 80% pick-up, of standard voltage.
•
Generator voltage sensing
Constantly monitors generator voltage to verify the cleanest power delivered to the home.
•
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
•
Engine warm-up
Verifies engine is ready to assume the load, setpoint approximately 5 seconds.
•
Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
•
Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator for
5 minutes every other week. Also offers a selectable setting far weekly or monthly operation providing
flexlbihty and potentially lower fuel casts to the owner.
•
Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
•
Main line circuit breaker
Protects generator from overload.
•
Electronic governor
Maintains constant 60 Hz frequency.
GENERAC'
20/22/24 kW
Features and Benefits
Unit
•
SAE weather protective enclosure
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph (241 km/h). Hinged key locking root panel for security. Lift -out front for easy access
to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
•
Enclosed critical grade muffier
Quiet, critical grade muffier is mounted inside the unitto prevent injuries.
•
Small, compact, attractive
Makes for an easy, eye appealing installation, as close as 18 in {457 mm) away from a structure.
Installation System
•
14 in (35.6 cm) ftexible fuel line connector
Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
•
Integral sediment trap
Meets IFGC and NFPA 54 installation requirements.
Connectivity (WI-Fi equipped models only)
•
Ability to view generator status
Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for
complete peace of mind.
•
Ability to view generator Fxercise/Run and Total Hours
Review the generator's complete protection profile for exercise hours and total hours.
•
Ability to view generator maintenance information
Provides maintenance information for the specific model generator when scheduled maintenance is due.
•
MonNy report with previous month's activity
Detailed monthly reports provide historical generator information.
•
Ability to view generator battery information
Built in battery diagnosfics displaying current state of the battery.
•
Weather information
Provides detailed focal ambient weather conditions for generator location.
20/22/24 kW
GEIVERAC
Specifications
Generator
Model
G007038-1
G007042-2
G007038-3 6007042-3
G00720M
S007039-1
G001043-2
G007039-3 1301
G00721M
(201
(221
(201 (221
(24 ftW)
Rated maximum continuous power capacity (LP)
20,000 Watts'
22,000 Watts'
20,000 Watts" 22,000 Watts`
24,000 Watts"
Rated maximum continuous power capacity (NO)
18,000 Watts"
19,500 Watts"
18,000 Watts` 19,500 Watts'
21,000 Watts -
Rated voltage
240
Rated maximum continuous load current — 240 volts (LP/NG)
83.3 / 75.0
91.7 / 81.3
83.3 / 75.0 91.7 / 81.3
100187.5
Total Harmonic Distortion
Less than 5%
Main line circuit breaker
90 amp
100 amp
90 amp 100 amp
100 amp
Phase
1
Number of rotor poles
2
Rated AC frequency
60 Hz
Power factor
1.0
Battery requirement (not included)
12 Volts, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum
Unit weight (Ib / kg)
4481203
466 / 211
438119E 4451202
455 / 206
Dimensions {L x W x H) in / cm
4B x 25 x 291121.9 x 63.5 x 73.7
Sound output in dB(A) at 23 ft (7 mJ with generator operating at normal load"
67
67
67 67
67
Sound output in d8(A) at 23 it (7 m}with generator in Quiet -Test' low -speed exercise mode"
55
57
55 57
57
Exercise duration
5 min
Engine
Engine type
GENERAC G-Farce 1000 Series
Number of cylinders
2
Displacement
999 cc
Cylinder block
Aluminum wy cast iron sleeve
Valve arrangement
Overhead valve
Ignition system
Solid-state w/ magneto
Governor system
Electronic
Compression ratio
9,5:1
Starter
12 UDC
Oil capacity including filter
Approx.1.9 qt/ 1.8 L
Operating rpm
3,600
Fuel consumption
Natural gas ft3/hr (m31hr)
112 Load 204 (6.78) 226 (6.46) 164 (4.64)
203 (5.75)
Full Load 301 (8,52) 327 (9.26) 287 (BA3)
306 (8.86)
Liquid propane fl3/ht (gaVi fUhr]
1/2 Load 87 (2.37) (8.991 92 (2.53) [9,571 86 (2.36) (8.951
92 (2.53) [9.571
Futi Load 130 (3.bi [13.481 142 (3.90) [14.771 136 (3.74) t14.151
142 (3,90) 114,771
Note: Fuel pipe must be sized for full load. Required luel pressure to generator luel inlet at all load ranges - 3.5-7 in water column (0.37-1.74 kPa) for NG, 10-12 in
water column (2.49-2.99 1 for LP
gas. For BTU content, multiply 0s/hr x 2500 (LP) or fi3lhr x 1000 {NG). for Megajoule content, multiply m3/hr x 93,15 (LP) or ml/hr x 37.26 (NO).
Two-line plain text multilingual LED
Simple user interlace for ease of operation.
Mode buftons: AUTO
Automatic start on utility failure -Weekly, St -weekly, or Monthly selectable exerciser.
MANUAL
Start with starter control, unit stays on. If utility fails, transfer to load lakes place.
OFF
Stops unit. Power Is removed. Control and charger still operate.
Ready to RuNMainlenance messages
Standard
Engine run hours indication
Standard
Programmable start delay between 2-1500 seconds
Standard (programmable by dealer only)
Bill illy Voltage Loss/Return to Utility adjustable (brownout setting)
From 14C-171 V / 190-216 V
Future Set Capable Exerciser/Exercise Set Error warning
Standard
Run/AlarrNMaintenance logs
50 events each
Engine staff sequence
Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration}.
Starter lock -out
Starter cannot re-engage until 5 sec after engine has stopped.
Smart Battery Charger
Standard
Charger Fault/Missing AC warning
Standard
Low 8attery/Baltery Problem Protection and Battery Condition indication
Standard
Automatic Voltage Regulation with Over and Under Voltage Protection
Standard
Under-Frequency/Overload/Slepper Overcurrent Protection
Standard
Safety Fused/Fuse Problem Protection
Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown
Standard
OvereranWOverspeed (�1a 72 Hi)/rpm Sense Loss Shutdown
Standard
High Engine Temperature Shutdown
Standard
Internal FaulVlncorrect Wiring protecffon
Standard
Common external tault capabillty
Standard
Field upgracil to firmware
Standard
""Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may he higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying
emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with 355514, IS03046 and DIN6271). ' Maximum kilovolt amps and current are
subjectta and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 fl (304.8 m) above sea
level: and also will decrease approximately 1 %for each 10 IF 1 °C) above 60 °F (16'C).
GENERAC
20/22/24 kW
Service Rated Automatic Transfer Switch Features
• Intelligently manages up to four air conditioner loads with no additional hardware.
• Up to eight additional large (240 VAC) loads can be managed when used in conjunction
with Smart Management Modules (SMMs).
• Electrically operated; mechanically -held contacts for fast, clean connections.
• Rated for all classes of load, 100% equipment rated, both inductive and resistive.
• 2-pale, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/tJL 33 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility
Dimensions
200 Amps 120/240, is
Open Transition Service Rated
Height
Width
H1
H2
W1
W2
Depth
in
26.8
30.1
10.5
13.E
6.9
cm
67.95
76.43
26.67
34,18
17.5
Wire Ranges
Conductor Lug
Neutral Lug Ground Lug
250 MGM - #6
350 MGM - #6 2/0 - #14
PWRview Automatic Transfer Switch Features
• Integrated PWRview monitor provides real-time energy usage data through PWRview app.
• intelligently manages up to four air conditioner loads with no additional hardware.
• Up to eight additional large (240 VAC) loads can be managed when used in conjunction
with Smart Management Modules (SMi
• Electrically operated; mechanically -held contacts for last, clean connections.
• Rated for all classes of load, 100% equipment rated, both inductive and resistive.
• 2-pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility.
• Heavy duty Generac Contactor is an ETL recognized device.
Dimensions
200 Amps 120/240,10
Open Transition Service Rated
Height
Width
Depth
H4
H2
W1
W2
in
26.8
30.1
105
13.5
6.9
cm
67.95
1 76.43
26,67
34.18
17.5
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
250 MGM - #6
350 MGM - #6
2/0 - #14
Switch Options
Model
G007039-1, G007039-3 (20 kW)
G007043-2, G007043.3 (22 kW)
No. of poles
2
Current rating (amps)
200
Voltage rating (VAC)
120/240, 10
Utilltyvoltage monitor (fixed)*
-Pick up
80%
Dropout
65`%
Return to Utility'
Approx. 13 see
Exercises bi-weekly for 5 minutes'
Standard
€TL or UL fisted
Standard
Enclosure type
NEMA/UL 313
Circuit breaker protected
22,000
Lug range
250 MOM - #6
'"Function of Evolution controller
Exercise can be set to weekly, bi-weekly, or monthly
Model
G007210-0 (24 kW)
No. of poles
2
Current rating (amps)
200
Voltage rating (VAC)
120/240, 10
Utility voltage monitor (fixed)'
Pick-up
80%
-Dropout
65%
Return to Utility`
Approx. 13 sec
Exercises bi-weekly for 5 minutes'
Standard
ETL or UL listed
Standard
Enclosure type
NEMA 3A
Circuit breaker protected
22,000
Lug range
250 MOM - #6
'Function of Evolution controller
Exercise can be set to weekly, bi-weekly,
or monthly
GENERAC®
20/22/24 kW
Available Accessories
Model # Product
Description
G005819-0 26R Wet Cell Battery
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for
use with all air -coaled standby product (excluding PowerPact®).
G007101-0 Battery Pad Warmer
Pad warmer rests under the battery. Recommended for use if temperature regularly falls below 0 °F (-18 °C). (Not nec-
essary for use with AGM -style batteries).
G007102-0 bit Warmer
Oil wanner slips directly over the ail filter. Recommended for use if temperature regularly falls below 0 °F (-18 °C).
G007103-1 Breather Warmer
Breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where
heavy icing occurs.
G005621-0 Auxiliary Transfer Switch
The auxiliary transfer switch contact kit allows the transfer switch to Pock out a single large electrical load that may not be
Contact Kit
needed. Not compatible with 50 amp pre -wired switches.
0007027-0 - Bisque Fascia Base Wrap Kit
The fascia base wrap snaps together around the bottom of the new air -coaled generators. This offers a sleek, contoured
(Standard on 22 kW)
appearance as welt as offering protection from rodents and insects by covering the lifting holes located in the base.
G005703-0 - Bisque .Touch -Up Paint Kit
If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion.
The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
G006485-0 Scheduled Maintenance Kit Generaos scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a
Generac automatic standby generator (oil not included).
G007005-0 Wi-Fi LP Tank Fuel Level
The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the
Monitor
LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure. Sta-
tus alerts are available through a free application to notify users when the LP tank is in need of a refill.
G007000-0 (50 amp) Smart Management Module Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages large elec-
G007006-0
trical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can reduce
(100 amp)
the overall size and cost of the system.
G007169-0 - 4G LTE Mobile LinO Cellular
The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world, using
G007170-0 - Wi-FV Accessories
a smart phone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Us-.
Ethernet
ers can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link,
users are taken care of before the next power outage.
G007220-0 - Bisque Base Plug Kit
Base plugs snap into the lifting holes on the base of air-cooled home standby generators, This offers a sleek, contoured
appearance, as well as offers protection from rodents and insects by covering the lifting holes located in the base. Kit
contains four plugs, sufficient for use on a single air-cooled home standby generator.
Dimensions & UPCs
Model
UPC
G007038-1
696471074185
G007038-3
696471074185
G007039-1
696471074192
G007039-3
696471074192
G007042-2
696411074208
G007042-3
696471074208
G007043-2
696411014215
G007043-3
696471074215
G007209-0
696471071511
G007210-0
606471078220
GENERAC®
72J
t21
, , L".' -
LEFT SIbE VIEW FRONT VIEW
Dimeisiors shown are approximate. See lastallaton manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac,com
@2020 Generac Power Syslems, Inc. AIT rights reserved. All specifications are subject to change without notice. Part No. ADD00937814 Rev. A 07/15/2020