Loading...
HomeMy WebLinkAboutGenerator Product Information & Specifications20/22/24 kW MEN__ INCLUDES: • True Power'" Electrical Technology s Two-line multilingual digital LCD Evolution" controller (Eng I ish/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor 0 Standard Wi-Fi® connectivity • System status & maintenance Interva€ LED indicators • Sound attenuated enclosure s Flexible fuel line connector s Natural gas or LP gas operation 0 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a structure.* "Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. hltps,-Ilassets.swri.org//ibraryIDirectoiyOfListedProducts/ Constructioolndustry/973_DoC 204_13204-01-07_Rev9.pdf FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- erac's success in providing the most reliable generators possible. Generac's G- Force engine lineup offers added peace of mind and reliability for when it's needed the most. The G-Force series ergfnes are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA l i-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY O MOBILE LINV' CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone, tablet, or PC. Easily access information such as the currert operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile. Link, users are taken care. of before the next power outage. GENERAL" GUARDIAN' SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW 60 Hz 3007042-2, G007043-2, G007042-3, G007043-3 (Aluminum - Bisque) - 22 kW 60 Hz G007209-0, G007210-0 (Aluminurn - Bisque) - 24 kW 60 Hz 01% or C V0 uSnu! cus LISTED `j( Nate: GETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac mod- els. It provides optimized FAST RESPONSE to changing load conditions and MAXI- MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads tone engine, Digital voltage regulation at ±1 %, O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the small- est electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for tl ss confidence is that the GENERAC product kne is offered with its own transfer systems and controls for total system compatibility. O PWRVIi TRANSFER SWITCH: The Generac PWtiview Automatic Transfer Switch integrates the PWRview energy monitor to provide real-time energy con- sumption data that can help lower a home's electricity bill. Using a convenient mobile app, homeowners can access energy usage and alert information while under utility power ar generator power. The PWRview energy monitor is a simple to use and low cost tool which helps save money over the life of the generator. Included with model G007210-0. w GENERAC GEN— E�: PROMISE Q e� � PWR GENERAC® 20/22/24 kW Features and Benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help tirc engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine lite. • Electronic ignition/spark advance These teatures combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. PWRview Transfer Switch (if applicable) • PWRview energy monitor Energy usage at -a -glance. • Abilityto view real-time energy consumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy intelligence and insights. Evolution" Controls • AUTG/MANUAUOFF illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpeints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting far weekly or monthly operation providing flexlbihty and potentially lower fuel casts to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. GENERAC' 20/22/24 kW Features and Benefits Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking root panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffier Quiet, critical grade muffier is mounted inside the unitto prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in {457 mm) away from a structure. Installation System • 14 in (35.6 cm) ftexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity (WI-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Fxercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • MonNy report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnosfics displaying current state of the battery. • Weather information Provides detailed focal ambient weather conditions for generator location. 20/22/24 kW GEIVERAC Specifications Generator Model G007038-1 G007042-2 G007038-3 6007042-3 G00720M S007039-1 G001043-2 G007039-3 1301 G00721M (201 (221 (201 (221 (24 ftW) Rated maximum continuous power capacity (LP) 20,000 Watts' 22,000 Watts' 20,000 Watts" 22,000 Watts` 24,000 Watts" Rated maximum continuous power capacity (NO) 18,000 Watts" 19,500 Watts" 18,000 Watts` 19,500 Watts' 21,000 Watts - Rated voltage 240 Rated maximum continuous load current — 240 volts (LP/NG) 83.3 / 75.0 91.7 / 81.3 83.3 / 75.0 91.7 / 81.3 100187.5 Total Harmonic Distortion Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement (not included) 12 Volts, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight (Ib / kg) 4481203 466 / 211 438119E 4451202 455 / 206 Dimensions {L x W x H) in / cm 4B x 25 x 291121.9 x 63.5 x 73.7 Sound output in dB(A) at 23 ft (7 mJ with generator operating at normal load" 67 67 67 67 67 Sound output in d8(A) at 23 it (7 m}with generator in Quiet -Test' low -speed exercise mode" 55 57 55 57 57 Exercise duration 5 min Engine Engine type GENERAC G-Farce 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum wy cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/ magneto Governor system Electronic Compression ratio 9,5:1 Starter 12 UDC Oil capacity including filter Approx.1.9 qt/ 1.8 L Operating rpm 3,600 Fuel consumption Natural gas ft3/hr (m31hr) 112 Load 204 (6.78) 226 (6.46) 164 (4.64) 203 (5.75) Full Load 301 (8,52) 327 (9.26) 287 (BA3) 306 (8.86) Liquid propane fl3/ht (gaVi fUhr] 1/2 Load 87 (2.37) (8.991 92 (2.53) [9,571 86 (2.36) (8.951 92 (2.53) [9.571 Futi Load 130 (3.bi [13.481 142 (3.90) [14.771 136 (3.74) t14.151 142 (3,90) 114,771 Note: Fuel pipe must be sized for full load. Required luel pressure to generator luel inlet at all load ranges - 3.5-7 in water column (0.37-1.74 kPa) for NG, 10-12 in water column (2.49-2.99 1 for LP gas. For BTU content, multiply 0s/hr x 2500 (LP) or fi3lhr x 1000 {NG). for Megajoule content, multiply m3/hr x 93,15 (LP) or ml/hr x 37.26 (NO). Two-line plain text multilingual LED Simple user interlace for ease of operation. Mode buftons: AUTO Automatic start on utility failure -Weekly, St -weekly, or Monthly selectable exerciser. MANUAL Start with starter control, unit stays on. If utility fails, transfer to load lakes place. OFF Stops unit. Power Is removed. Control and charger still operate. Ready to RuNMainlenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Bill illy Voltage Loss/Return to Utility adjustable (brownout setting) From 14C-171 V / 190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/AlarrNMaintenance logs 50 events each Engine staff sequence Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration}. Starter lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC warning Standard Low 8attery/Baltery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Slepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard OvereranWOverspeed (�1a 72 Hi)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaulVlncorrect Wiring protecffon Standard Common external tault capabillty Standard Field upgracil to firmware Standard ""Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may he higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with 355514, IS03046 and DIN6271). ' Maximum kilovolt amps and current are subjectta and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 fl (304.8 m) above sea level: and also will decrease approximately 1 %for each 10 IF 1 °C) above 60 °F (16'C). GENERAC 20/22/24 kW Service Rated Automatic Transfer Switch Features • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated; mechanically -held contacts for fast, clean connections. • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2-pale, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/tJL 33 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility Dimensions 200 Amps 120/240, is Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 26.8 30.1 10.5 13.E 6.9 cm 67.95 76.43 26.67 34,18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MGM - #6 350 MGM - #6 2/0 - #14 PWRview Automatic Transfer Switch Features • Integrated PWRview monitor provides real-time energy usage data through PWRview app. • intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMi • Electrically operated; mechanically -held contacts for last, clean connections. • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Heavy duty Generac Contactor is an ETL recognized device. Dimensions 200 Amps 120/240,10 Open Transition Service Rated Height Width Depth H4 H2 W1 W2 in 26.8 30.1 105 13.5 6.9 cm 67.95 1 76.43 26,67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MGM - #6 350 MGM - #6 2/0 - #14 Switch Options Model G007039-1, G007039-3 (20 kW) G007043-2, G007043.3 (22 kW) No. of poles 2 Current rating (amps) 200 Voltage rating (VAC) 120/240, 10 Utilltyvoltage monitor (fixed)* -Pick up 80% Dropout 65`% Return to Utility' Approx. 13 see Exercises bi-weekly for 5 minutes' Standard €TL or UL fisted Standard Enclosure type NEMA/UL 313 Circuit breaker protected 22,000 Lug range 250 MOM - #6 '"Function of Evolution controller Exercise can be set to weekly, bi-weekly, or monthly Model G007210-0 (24 kW) No. of poles 2 Current rating (amps) 200 Voltage rating (VAC) 120/240, 10 Utility voltage monitor (fixed)' Pick-up 80% -Dropout 65% Return to Utility` Approx. 13 sec Exercises bi-weekly for 5 minutes' Standard ETL or UL listed Standard Enclosure type NEMA 3A Circuit breaker protected 22,000 Lug range 250 MOM - #6 'Function of Evolution controller Exercise can be set to weekly, bi-weekly, or monthly GENERAC® 20/22/24 kW Available Accessories Model # Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air -coaled standby product (excluding PowerPact®). G007101-0 Battery Pad Warmer Pad warmer rests under the battery. Recommended for use if temperature regularly falls below 0 °F (-18 °C). (Not nec- essary for use with AGM -style batteries). G007102-0 bit Warmer Oil wanner slips directly over the ail filter. Recommended for use if temperature regularly falls below 0 °F (-18 °C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to Pock out a single large electrical load that may not be Contact Kit needed. Not compatible with 50 amp pre -wired switches. 0007027-0 - Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air -coaled generators. This offers a sleek, contoured (Standard on 22 kW) appearance as welt as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0 - Bisque .Touch -Up Paint Kit If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generaos scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator (oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the Monitor LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure. Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0 (50 amp) Smart Management Module Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0 - 4G LTE Mobile LinO Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world, using G007170-0 - Wi-FV Accessories a smart phone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Us-. Ethernet ers can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. G007220-0 - Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators, This offers a sleek, contoured appearance, as well as offers protection from rodents and insects by covering the lifting holes located in the base. Kit contains four plugs, sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696411074208 G007042-3 696471074208 G007043-2 696411014215 G007043-3 696471074215 G007209-0 696471071511 G007210-0 606471078220 GENERAC® 72J t21 , , L".' - LEFT SIbE VIEW FRONT VIEW Dimeisiors shown are approximate. See lastallaton manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac,com @2020 Generac Power Syslems, Inc. AIT rights reserved. All specifications are subject to change without notice. Part No. ADD00937814 Rev. A 07/15/2020