Loading...
HomeMy WebLinkAboutRevisionOFFICE USE ONLY: DATE FILED: REVISION FEE ' `s. O PERIVIIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 23.00 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (7-72)462-1.193 ST. LUCIE COUNTY BUILDING DIVISION APPLICATION FOR BUILDI 413 PERMIT RE'►ISIONSIED PROJECT INFO Ip®III COMP is �t lE1MW BY DATE o. LOCATION/SITE PLANS mo PERMIT ADDRESS: 771� MUST 139 E�EI�'1" ON, JOB OR DX • NO INS!ECTION WILL BE MADE DETAILED DESCRIPTION OF PROJECT REVISIONS: Pe l V6, 4 71',o A 00NTRACTOR INFORMATION: STATE of FL REG./CERT. #: ,S aS�S S� ST. LUCIE CO CERT. #: 5 BUSINESS NAME: a n r,P f QUALIFIERS NAME: rr c ADDRESS: Z .. _ CITY: SP�a �-r_� STATE: PHONE (DAYTIl ffi): ,S'�Z� Ql Id ld FAX: 3f? _% l ®y OWNER/BuELDER INFORMATION: NAME: G� rn '8 r ADDRESS: CITY: P.,C' C STATE: IeL ZIP: PHONE (DAYTIME: FAX: ARCEnECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: . FAX: Orol EV' I S 10 w Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone: (772)462 1553 Fax:(772)462-1578 BUILDING PERMIT Online address:-htip:%/www:s0ucieco.o�/pfanninglpennitting.htm Quick Links: Permit Status Lookup Online Building Inspection System Permit #: SLC 1711-0265 Confirmation #: 457 Job Location: 2703 BENT PINE DR Permit Type: GAS/GAS PIPING -1 & 2 FAMILY Status: ISS RESIDENTIAL Job Description: BURY # 250 TANK. AND 314" POLY LINE. Subdiv: MONTE CARLO COUNTRY CLUB UNIT 2 Lot: 97 Setbacks Left: Number of Units: -1 Flood Map: Block: Right: Front: Floors: 1 Flood Zone: X 3� Elev: Buildings: 1 Issued: -1111512017 City: FORT PIERCE. Date Expired: 05/16/2018 Parcel: 1334-502-0014-00011 Rear. Zoning: PUD Square Footage: Contractor ERIC L MACHADO SECURE GAS & MAINTENANCE INC (772) 538-9606 13660 77TH ST • SEBASTIAN, FL 32958 Property Owner GHO MEADOWOOD CORP (546)131=9281 590 NW MERCANTILE PL PORT ST LUCIE, FL 34986 Permit holder acknowledges through acceptance of this pennit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing and structural work. Further he/she acknowledges responsibility to comply with all requirements of the Florida Bulding Code and the St Lucie County Land Devlelopment Code. Issuance of this permit may be appealed to the St Lucie county Board of Adjustment by an aggrieved party by filing a notice of appeal with -St. Lucie County Growth Management Director within thirty (30) days of the issuance of this permit in accordance with St Lucie County Land Cevelopment Code, Section 11.11.00., Appeals. Building Permits shall expire and become null and void if work authorized by suclkBuilding Permit is not commenced, having called for and received a satisfactory Inspection within six (6) months from the date of issuance of the permit or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit in accordance with St Lucie County Land Development Code Section 11.05.01 (A)(2). NOTICE: In addition to the requirements of this permit, there may be. additional restrictions applicable to this property that may be found in the records of this county, and there may be additional permits required from other governmental entities such as water management disitricts, state agencies, or federal agencies. s:553.79(10), F.S. . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. a NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. " IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORIDNG YOU NOTICE OF COMMENCEMENT. s:713.135 (10(a), F.S. Carl Peterson Building Official Date i e3, FND P (,Noll 99.6' } 99.9, e, •s � J .0. LL 0- p k F0c ;::i- ` - Yoh N Cv / n c 6 2 49VF� \',1 J+i� W E � 9— 9� 99k 98 VAACArNT) ( SCALE 1"=40' LOT 99 (VACANT) as LEGEND A o CU17M ARGUE R - CURVE WIUS L - CURVE LENGTH (C) - CALCULATED (P) - PLAT CERTIFIED TO: IR = 5i IRON ROD GHO MEADOWOOD CORPORATION H Tn' Prof aILU = OYQa1F11D UTRTIIFS DESCRIPTION a CONCRETE MONUMENT WE = FTN191 BOOR ELEVATION LOT 97, MONTE CARLO COUNTRY CLUB -UNIT 2, ACCORDING TO THE PLAT THEREOF. AS I ' HM NA AND aLSK P.LS - PRaFE59GNAL LAND SURVEYOR RECORDED IN PLAT BOOK 23. PAGE 26, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY. FLORIDA-LB = uc�um t1U P.B. = PUT BOOK SAID LAND CONTAINS 0.43 ACRES, MORE OR LESS. R/w - RIGHT-OF-WAY ® - MSRNG WELL SURVEY NOTES o =AT&T PEDESTAL 1. This survey is not valid without a signature and original embossed seal of a Floi)da ®= WATER METER Professional Land Surveyor. crb - WOOD POWER POLE 2. Description provided by client and/or their agent O - FRO M (No ID) 3. The last date of field work was May 22, 2017. CONC = CONCRETE 4. Underground improvements and foundations were not located as part of this survey. DR n R IRON ROD & CAP ' 5. Bearings shown hereon are based on the Westerly R/W line of Bent Pine Drive, bearing D.U.E - DRAINAGE AND ummr EASFNE S36'40'06'E, per plat end as monumented. All bearings are relative thereto. x-- e• VINT. FENCE 6. Ali boundary information shown is calculated per plot, unless otherwise shown. 0 -CAM TELEVISION BOX 7. Property lies in flood zone 'X', per mop 12111CO16D J. dated 2-16-12. V -FIRE HYDRANT B. Additions or deletions to survey maps or reports by other than the signing party or A - WATER VALVE parties is prohibited without written consent of the signing party Or parties. NSLRWCO - NORTH ST. WOE RIVER WATER 9. All elevations shown are based on an assumed datum. CONTROL DISTRICT LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR RIGHT OF WAYS, �� RESERVATIONS. A%MENT. AND/OR EASEYFNTS OF RECORD. SUCH (/` - DFFORMATTON, IF DESIRED, SHOULD BE OBTAINED AND CONFIRMED. BY OTHERS THROUGH APPROPRIATE TITLE VERIFICATION. BY. 'RICHARD C. LAVEN RE, FLORIDA P.L.97 #5209 DATE REVISION DESCRIPTION DATE BOUNDARY SURVEY 1 ADD PROPOSED FIFE 6/7/17 PREPARED FOR GHO MEADOWOOD CORPORATION REF. JOB NO. DRAWN BY DATE DRAWING NO+LB LAVENTURE & ASSOCIATES. INC. 17.185D-103 MWH 5/24/17 17.1850-103PROFESSIONAL SURVEYING AND MAPPING F.B..PG. CALCULATED B SCALE SHEET N0. 774 W. MIDWAY ROAD FORT PIERCE. FLORIDA 34962 GPS RCL 1'=40' 1 OF 1 7056 (772) 398-6430 PHONE (772) 396-6426 FA M • UP V IL 9 -� A I CIUV , KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 PO. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 October 30, 2017 Eric Machado Secure Gas, Inc. 1064 Persian Lane Sebastian, Florida 32958 Re: 250 Gallon Underground Tank 2703 Bent Pine Drive Fort Pierce, Florida KSM Project #: 173252-lpgas Dear Mr. Machado: Please see attached detail for how to tie down the 250 gallon underground tank at the referenced site. The following are general notes concerning the attached drawing. 1. Prior to installing the earth augers, check for underground utilities. 2. Earth auger and cables shown are designed to resist buoyancy forces from an empty tank fully submerged. 3. Earth augers type and length is dependent of Soil Class. For this site soil is assumed as Class 4 Soil. If the onsite soils are not Class 4, engineer is to be notified. 4. Earth auger shall have a tested minimum pull out value of 3000 lbs. 5. Location of tanks are dependent on local codes and are the responsibility of the persons obtaining the permit. Please accept this letter as certification that it is our intent to meet the regulations as specified in Section 930.07(2)(g) of Indian River County's Land Development Code. 2#�1iYii�l�gi ,questions, N SS c,Q ectFt�ly No.6�, jr....-- please feel free to contact the office. iregas@yahoo.com Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 GROUND LEVEL 1/4#" IVANIZED VINYL 250 GAL \/j/C �DWIRE ROPE LP GAS / \\/y �\ TANK `/ 518" x 48" TRAILER ANCHOR WITH 6"HELIX (4REQUIRED) GROUND LEVEL 1/4" GALVANIZE \\ VINYL COATED \\ /\ WIRE ROPE 250 GAL /\ LP GAS \ TANK \\ \\ \\ \ \ \ \ \ \ \\ \\ \\ \\ \\ \\ \ 5/8" x 48" TRAILER ANCHOR \ •' \�\ WITH 6" HELIX vT'• , 10 \ \\ \ \ - -� . 0 . ..... ENGINEE L$�j �9LOR; IF NOT CONTACT ENGINEER°1'0,AUTHENTIC PROJECT: SECURE GAS: 2703 Bent Pine Drive Fort Pierce, Florida SHEET 1 OF 1 T-w xEN DRAWN BY: J.L. dr 04-ok 'mFL PE # 68366 DESIGNED BY: J.K. PROJECT NO.: 173252 AL16 NO 111�M NONE AND TESTING DATE: 10 SCALE: NONE F GF FND PKP. (NO. ID)::.10 F i6'9 / ' 99.6• 9 F y0�'pyG��` 99* S� 0. • Cb1 d• s , y s �1�?S �, _ - �o--• z: 'P tk RFj N N \ O 70•\ �h�/ aim -3 7726' .� LOT 98 (VACANT) SCALE : 1"=40' k LOT 99 (VACANT) LEGEND A = cum& ANIAE Y� ' R WRVS RADIUS l WRVS LIXWM (C) . CALCULATED ' (P) a PLAT CERTIFIED TO: ro = ram 5/6 SON ROD • P = 1jr am PIPE CHO MEADOWOOD CORPORATION am ovamm UMM DESCRIPTION �FU FFE u F71/91 FLUOR ElEVATtw LOT 97, MONTE CARLO COUNTRY CLUB -UNIT 2. ACCORDING TO THE PLAT THEREOF, AS pa o PK NAL AND MsK Pt.s w lAna suavETOR RECORDED IN PLAT BOOK 23. PAGE 26. OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORID• • o LIED � P.B. a PLAT BOOK SAID LAND CONTAINS 0.43 ACRES, MORE OR LESS' R/W ra°t ® . EASnNG WELLaL SURVEY NOTES o -AT&T PEDESTAL 1- This survey is not valid without a signature end original embossed seal of o Floiido ® a WATER NEIM Professional Land Surveyor. 2. Description provided by Client and/or their agent. C(23- r1000 POW Pats O o FHD M (ND tD) 3. The lost date of field work was May 22, 2017- 4. Underground improvements and foundations were not located as part of this survey. w CONC UatE16 MC #, taw BUD a'CAP ' 5. Bearings shown hereon are based an the Westerly R/W line of Bent Pine Drive, bearing VA& - DRAMACE AND umnY EAsm X W VDM FMM S36'40'O6'E, per plot and as monumented. All bearings ore relative thereto. information is calculated per plat, unless otherwise shown. 0 -CABLE TELEMON BOK 6. AD boundary shown 7. Property lies in flood zone ')', per map 12111CO160 J doted 2-16-12.. reports by other than the signing party or ZC - ARE HTURAW D4 o WATER VALVE B. Additions or deletions to survey maps or parties is prohibited without written consent of the signing party or parties. NSRrAo a �0. � WATER 9. Ali elevations shown are based on an assumed datum. LANDS 9tOtw HERSM WHE NDr ABSmACIED RN WMT OF WAM REMNA1UM-AMMUM S AND/at EASOLQA5 OF BOOM suw :. � _ aSORY1a1DN. lF Df9AEA SNOUID tff MOM AND CORFMM.S.Y OTtERs TFaWINOt m—Robrx.9 VONICAML BY: _ /'.'JUtX RICH D: C. LAVEN, R > ,FLORIDA P.L.S. 05209 DATE DA1 BOUNDARY SURVEY REVISION DESCRIPTION 1 ADD PROPOSED FIFE e/7/17 PREPARED FOR GHO MEADOWOOD CORPORATION REF. JOB 110.1 DRAWN BY DATE DRAWING NO LAVOTURE & ASSOCIATES, INC.11.1850-1031 MWH 5/24/17 17.1850-103 PROFESSIONAL SURVEYING AND MAPPING F.B.,PG. ALCULATED B SCALE SHEET NO. FORT I HIE, FLORIDAROAD FORT PIERCE. FL34982 CPS RCL 1'=40 1 OF 1 LB 7056 (772) 395-6430 PHONE (772) 395-6426 F/