HomeMy WebLinkAboutSunrise 2121 Elizabeth Ave, Ft. Pierce-dsUES Project No:
Workorder No:
Report Date:
3360.1800008.0000
262178-1
03/01/2022
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:Sunrise City Community Housing Development Organization
Inc.
UES Technician:Mark Rogers
Attn: Roderick Waller, CEO 130 S. Indian River Dr, Suite 202
Fort Pierce, FL 34950
Date Tested:02/25/2022
Project:Sunrise City Community Development
Various Locations, , TBD County, FL
Type of Test:
Area Tested:2121 Elizabeth Ave, Ft. Pierce - Pad Field:ASTM D-6938 Nuclear Gauge Method
Material:Backfill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Northeast corner of pad 0-1 ft 105.3 12.8 103.7 12.2 98 Pass
2 Southwest corner of pad 0-1 ft 105.3 12.8 104.1 12.3 99 Pass
3 Center of pad 0-1 ft 105.3 12.8 104.5 12.3 99 Pass
Remarks:Permit: 2107-0303
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Alex Albandoz, P.E.
STATE OF FLORIDA
Professional Engineer No. 92555
This item has been digitally signed and sealed by Alex Albandoz,
P.E. on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.