Loading...
HomeMy WebLinkAbout3116 NW Radcliff Way sht 4PRE-ENGINEERED TRUSSES @ 24" C PRE-ENGINEERED ` SET & OVERFRAMI SIMPSON MTS12 @ _.. _. . END AND @ 48" O.C. 1/2 8" PRECAST U—LII\ INSTALL VALCOM E CONCRETE & BUCk SEAL ALL VOIDS PERIMETER CAULKII CAULKING TO MAT( WINDOW FRAME CO SINGLE HUNG WIND( WITH IMPACT GLAS PERIMETER CAULKIN CAULKING TO MATC WINDOW FRAME COI FORMED 8c POURED CONCRETE SILL WIT (1) #5 BAR 1 1/2°' = 1'-091 POURED C( CELL WITH RECESSED CONCRETE 1" X 6" P.T. NAILER 1/2" DRYWALL 3/4" FOAM INSULATION I" X 4" P.T. NAILER NINDOW TRIM " X 6" BORATE P.T. BUCK ATTACHED TO CONC. WITH /4" X 5" TAPCONS PACING PER MANUFACTURE 'OOD WINDOW STOOL X 4" P.T. NAILER INDOW TRIM '2" DRYWALL /4" FOAM INSULATION 2" X 6" P.T WOOD BUCK ANCHOR TO C.B.S. WALL WITH (6) 3/8" X 4" SLEVE ANCHORS ITT RAMSET #HN-3830 OR EQUAL SUBSTITUTE. SPACING AS PER DOOR MANUFACTURE. ( INSTALL WINDOW OR DOOR, FASTEN PER PRODUCT APPROVAL AND SEAL WINDOW OR DOOR FRAME TO P.T. WOOD BUCK AND MASONRY. N.T.S. I 8" PRECAST U INSTALL VALC( CONCRETE & E SEAL ALL VOIC PERIMETER CAL CAULKING TO N WINDOW FRAME IMPACT GLASS 1 1/2°' POURED C( CELL WITH PERIMETER CAULKING WINDOW FR BRICK MOL[ RECESSED CONCRETE IMPACT GL, 0 �2 SET P.T. WOOD BUCK OVER C.M.U. WATERPROOFING IN URETHANE SEALANT, FASTEN PER PRODUCT APPROVALS. 3� APPLY LIQUID WATERPROOFING MEMBRANE OVER THE TOP AND FACE OF BUCK & SILL. A) SEAL EDGE OF P.T. WOOD BUCK TO MASONRY. WATERPROOFING COATINGS ON WINDOW SILLS, JAMBS & BEAMS. APPLY AROUND CORNER AND EXTEND 8" ALL AROUND FACE OF THE WALL. 1" X 6" P.T. NAILER 1/2" DRYWALL 5/4" FOAM INSULATION " X 4" P.T. NAILER VINDOW TRIM ' X 8" BORATE P.T. BUCK TTACHED TO CONC. WITH /4" X 6" TAPCONS PACING PER MANUFACTURE DOR TOP PANEL 1" X 3" P.T. FURRING STRIPS AT 16" O.C. 1/2" DRYWALL 3/4" FOAM INSULATION 1" X 4" P.T. NAILER DOOR CASING I" X 8" BORATE P.T. BUCK ATTACHED TO CONC. WITH 1/4" X 6" TAPCONS SPACING PER MANUFACTURE ALUMINUM THRESHOLD 1.5" STANDING SEAM, 24 GAUGE METAL ROOFING ON EXTERIOR C.M.U. WALL 1 LAYER OF POLYSTICK TU PLUS UNDERLAYMENT APPLIED TO 5/8" EXTERIOR GRADE APA PLYWOOD INSTALLED PERPENDICULAR TO THE ROOF FRAMING WITH END JOINTS STAGGERED, NAILED TO TRUSSES WITH 8d RING SHANK NAILS @ 6" O.C. & 4" O.C. AT ZONE 3. SIMPSON HETA16 EMBEDDED 4" IN CONCRETE BEAM & NAILED TO TRUSS WITH (9)10d X 1/27---\ STANDARD HEEL HT. OR MATCH EXISTING 10'— 8" OR MATCH EXISTING -Il BEARING &CEILING HGT. Ir GALVANIZED FLASHING ON 1" X 3" DRIP EDGE ON 2" X 8" SMOOTH CEDAR FASCIA NAILED TO SUB FASCIA SMOOTH STUCCO OVER METAL LATH (NO VENTS) OR MATCH EXISTING SMOOTH STUCCO "LAP SIDING" ON 8" X 16" CBS. WALL WITH #5 BAR VERTICAL STEEL AS PER PLAN. SMOOTH STUCCO TRIP BANDS MATCH EXISTING HT, MINIMUM 30" OVERLAP FROM DOWEL STEEL TO VERTICAL WALL STEEL SMOOTH STUCCO #5 DOWEL WITH 10" HOOK TIED TO FOOTER STEEL AS PER PLAN, FINISH GRADE D'_ 0" -FINISH FLOOR 12 4�/ IGYNENE LD—C-50 SPRAY FOAM INSULATION ON TOP CHORD OF TRUSS (R-20) 5/8" DRYWALL LID 1" X 4" P.T. NAILER (2) COURSES OF 8" X 16" BEAM BLOCK WITH (1) #5 BAR IN EACH, FILL POURED CELLS & BEAMS WITH 3000 PSI. PUMP MIX 1" X 4" P.T. FIREBLOCK NOT TO EXCEED 8'0" AFF -1/2" DRYWALL 3/4" (R-4) FOAM INSULATION 1" X 3" P.T. FURING STRIPS @ 16" O.C. 1" X 6" P.T. NAILER ® BASE BASE BOARD 4" THICK (3000 PSI) CONCRETE SLAB WITH 6X610/10 WWF. ON CHAIRS. 18" X 18" MONOLITHIC FOOTER WITH (3) #5 BARS CONTINUOUS. _ VISQUEEN VAPOR BARRIER _ CLEAN, COMPACTED, TERMITE TREATED SOIL (2500 PSF. SOIL) Joe Digitally signed by Joe McCarty Mcc arty Date:",; 2021.12.10 :17-05'00' ROOF TRUSS BOTTOM CHORD 5/ b.. DRYWALL CEILING 3 5/8" 20 GAUGE METAL TOP PLATE PROVIDE 2" X 4" FIREBLOCK. -DBL. 2" X WOOD STUDS ON EACH SIDE OF R.O. -3 5/8" 20 GAUGE METAL STUDS @ 16" 0. C. PROVIDE 1/4" X 5" TAPCONS AT 16" O.C. THROUGH 2" X STUD AND INTO C.B.S. WALL 3 5/8" 20 GAUGE METAL BASE PLATE 2" X P.T. SILL PLATE CONCRETE FLOOR —III�DIIII . l: r. .f f 14 r4 9 w n- Li j Qryr Q� U E �Q z 0 w c- 0 0 wQ �n n cn cn � o DRAWN BY R.C. DATE 8 DEC 2021 REVISIONS 1 1/2°' 11/2°' 1/2"