Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOF TILE ADHESIVES6/30/2021 Florida Building Code Online ProfessionalLi r BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links Search FI 17da r Product Approval D,,-. �` USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL6332-R9 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer ICP Adhesives & Sealants, Inc. Address/Phone/Email 12505 NW 44th Street Coral Springs, FL 33065 (888)774-1419 Ext201 rylipelkonen@icpadhesives.com Authorized Signature Riku Ylipelkonen rylipelkonen@icpadhesives.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roof Tile Adhesives Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/21/2024 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL6332 R9 COI 2020 01 COI NIEMINEN.pdf Standard SSTD 11 Year 1997 Product Approval Method Method 1 Option D https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquanCtKft6f%2fM%2b3ax6XpXuonHOZ5EfLMrw°/a3d 1/2 6/30/2021 Florida Building Code Online Date Submitted 09/29/2020 Date Validated 10/04/2020 Date Pending FBC Approval 10/11/2020 Date Approved 12/15/2020 Summary of Products FL # Model, Number or Name Description 6332.1 POLYSET AH-160 Dual component expanding polyurethane roof tile adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL6332 R9 II 2020 09 29 FINAL ER POLYSET Approved for use outside HVHZ: Yes AH160 FL6332-R9.pdf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +n/a/-178 Created by Independent Third Party: Yes Other: 1.) The design pressure limitation in this application Evaluation Reports refers to hip and ridge tiles in one configuration. Refer to Table FL6332 R9 AE 2020 09 29 FINAL ER POLYSET 2 of ER for all hip and ridge tile limitations. 2.) Field tiles are AH160 FL6332-R9.pdf designed based on overturning moment resistance. Refer to Created by Independent Third Party: Yes Table 1 of ER for field tile limitations. 3.) Refer to ER Sections 5 for other Limitations of Use. Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: = = ® Check Credit Card Safe https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquanCtKft6f%2fM%2b3ax6XpXuonHOZ5EfLMrw%3d 2/2 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 04 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION• ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-R9 12505 NW 441" Street FL6332-R9 Coral Springs, FL 33065 Date of Issuance: 08/08/2008 (888) 774-1419 Revision 9: 09/29/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7" Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: POLYSETO AH-160 LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. of The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 _ ,,. ;;{,,;« Nieminen, P.E. on 09/29/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, LLC ONEMOletc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Roof Tile Adhesives Compliance Statement: POLYSET® AH-160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the following sections of the 7" Edition (2020) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Sections Property Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 Entity Examination Reference Date ERD (TST 6049) Static Uplift — SSTD 11 P39740.02.12 02/20/2012 ERD (TST 6049) Static Uplift — SSTD 11 P39740.11.13-R1 01/02/2015 ICC-ES (EVL2396) 2012 IBC Compliance ESR-1709 12/01/2018 Miami -Dade (CER 1592) HVHZ compliance 17-0322.03 04/27/2017 NEMO (TST6049) Tensile Adhesion (ridge metal) 4i-ECM-20-SSCRT-01 09/29/2020 NEMO (TST6049) Tensile Adhesion 4p-ICP-20-SSLAP-01 09/29/2020 PRI (TST 5878) Static Uplift — SSTD 11 ECM-001-02-01 09/21/2001 PRI (TST 5878) Static Uplift — SSTD 11 PFI-006-02-01 05/09/2005 PRI (TST 5878) Static Uplift — SSTD 11 PFI-006-02-02 05/09/2005 PRI (TST 5878) Static Uplift — SSTD 11 PFI-007-02-01 10/11/2005 PRI (TST 5878) Static Uplift — SSTD 11 PFI-008-02-04 02/21/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFI-009-02-03 02/21/2006 PRI (TST 5878) Static Uplift — SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift — SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFPI-011-02-01 12/07/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFPI-012-02-01 12/07/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFPI-013-02-01 12/07/2006 PRI (TST 5878) Static Uplift — SSTD 11 PFPI-014-02-01 12/07/2006 PRI (TST 5878) Static Uplift — SSTD 11 ECM-003-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM-004-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM-005-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM-006-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM-007-02-01 06/13/2008 PRI (TST 5878) Static Uplift — SSTD 11 ECM-008-02-01 06/13/2008 UL LLC (QUA 9625) Quality Assurance Service Confirmation 02/07/2018 UL, LLC. (QUA 9625) Quality Assurance Florida BCIS Current POLYSET® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders. NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET® AH-160 Revision 9: 09/29/2020 Page 2 of 10 ONEMOletc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or R902 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. 5.6 POLYSET® AH-160 may be used with flat, low and high profile tiles having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.7 Field tiles, meeting the limitations of FBC 1609.5.3, using POLYSET° AH-160 are limited to projects having an Aerodynamic Uplift Moment (M,,), determined in accordance with Table 2HB, 2HC, 2HD, 2GB, 2GC or 2GD of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or FBC 1609.5.3, not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 1: FIELD TILES IN POLYSET® AH-160 ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA (MARGINS OF5AFETYALREADY APPLIED) Tile (FBC 1609.5.3) Adhesive Paddy Placement (Section 10) Allowable Placement Overturning Type Profile Detail Paddy Details Moment (ft-lbf) #1 Independent; Single Paddy, Medium (2x7-inch, ^30 gram) 60 Clay or Flat /Low #2 Independent; Single Paddy, Large (2x10-inch, —45 gram) 112 Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at tile Concrete #3 overlap) 54 #1 Independent; Single Paddy, Medium (2x7-inch, —30 gram) 39 Clay or Medium #2 Independent; Single Paddy, Large (2x10-inch, —54 gram) 67 Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at tile Concrete #3 overlap) 58 Clay High #3 Independent; Single Paddy, Large (2x10-inch, —45 gram) 134 #1 Independent; Single Paddy, Medium (2x7-inch, —30 gram) 65 Clay or High #2 Independent; Single Paddy, Large (2x10-inch, —63 gram) 109 Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at tile Concrete #3 overlap) 40 Clay Barrel #4 2x10-inch x ^35 gram for pans; 2 @ 1x10-inch x —17 gram for cap 147 Concrete Barrel #4 2x10-inch x ^35 gram for pans; 2 @ 1x10-inch x —17 gram for cap 107 Clay Cap atop 2x #5 Independent: Continuous Paddy (-34 gram/ft) 135 stringer Concrete Cap atop 2x #5 Independent: Continuous Paddy p y (� 34 gram/ft) 116 stringer ClayCap atop 2x #6 Interdependent: 105 stringer Head: One (1) #10 x 2%" screw; Overlap: 1 x 6 inch (-10.5 gram) Concrete Cap atop 2x #6 Interdependent: 76 stringer Head: One (1) #10 x 2%" screw; Overlap: 1 x 6 inch (-10.5 gram) NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET® AH-160 Revision 9: 09/29/2020 Page 3 of 10 ONEMOletc. 5.7.1 Data in Table 1 relates to installation over a TWO-PLY underlayment system, as detailed in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, using a hot -asphalt -applied, ASTM D6380, Class M cap sheet (commonly called a '30/90 system'). Alternate underlayment systems are those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction, listed specifically for use with POLYSET® AH-160. 5.7.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with POLYSETO AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent multi -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'. 5.8 Hip and ridge tiles using POLYSET® AH-160 are limited to projects having hip/ridge design pressure requirements, Table 1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or the applicable design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3, not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2: HIP & RIDGE TILES IN POLYSET11 AH-160 ALLOWABLE UPLIFT RESISTANCE PERFORMANCE DATA MARGINS OF SAFETY ALREADY APPLIED) Placement Allowable Tile Substrate Detail Attachment Details Design (Section 10) Pressure (psf) Clay 2x PT ridge board #5 Independent: Continuous Paddy (-34 116 gram/ft) Concrete 2x PT ridge board #5 Independent: Continuous Paddy (— 34 107 gram/ft) Clay 2x PT ridge board #6 Interdependent: Head: One (1) #10 x 2%" 90 screw; Overlap: 1 x 6 inch (-10.5 gram) Concrete 2x PT ridge board #6 Interdependent: Head: One (1) #10 x 2%" 56 screw; Overlap: 1 x 6 inch (-10.5 gram) Clay or East Coast Metals "Trim Lock'"^" (FL5374): #5 Independent: Continuous Paddy (-34 173 Concrete aluminum, Galvalume® or stainless steel gram/ft) Clay or East Coast Metals "Trim Lock'"" Plus" Independent: Continuous Paddy 34 Concrete (FL5374): aluminum, Galvalume® or #5 gram/ft) 178 stainless steel Clay Ridged Systems "Top Notch" (FL8095) #5 Independent: Continuous Paddy ( 32 125 gram/ft) Concrete Ridged Systems "Top Notch" (FL8095) #5 Independent: Continuous Paddy 32 146 gram/ft) NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET® AH-160 Revision 9: 09/29/2020 Page 4 of 10 ON EMO I etc. 6.1 POLYSET® AH-160 and the tile roof assembly shall be installed in accordance with the manufacturers' current published instructions, but not less than the requirements of FBC 1507.3 and the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, subject to the limitations in Section 5. 6.1.1 Installation of POLYSET° AH-160 shall be performed by applicators that hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. 6.2 Underlayment shall hold current Florida Product Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable use with POLYSET® AH-160. The underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. 6.3 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. I IF As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Tomball, TX 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (414) 248-6409; Karen.buchmann@ul.com NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET® AH-160 Revision 9: 09/29/2020 Page 5 of 10 10.1 I DETAIL #1: Independent, Medium Paddy: Nail through plastic cement Mhen required) Underlayment 0 h� 7in.�.�in. Battens optional ° Eaves Co u rse 0. Eave Clasura Paddy (Beneath Tile) •asaa i Flat/Low Profile Tile Nail through plastic cement (wh en req u fired) Underlayment I r 7 in. 2 in. Battens opti ona I Eave *NEMO I etc. 0 10in.- 21 Medium Profile Tile Nail through plasticce (when required) Paddy (Beneath Tile) Underlayment r 7 in. - 2in. Battensoptional , r Eave Course Fascia Weephole 70in. tin. Eave closure �. �2i' Drip edge High Profile Tile Paddy (Beneath Tile) `L Eave Closure Fascia NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET® AH-160 Revision 9: 09/29/2020 Page 6 of 10 ON EMO I etc. 10.2 DETAIL #2: Independent, Large Paddy: Nail through plastic cement Paddy i6eneath Tile} (when required) Underlayment a 10 in. - Battens optional .y Eave Cou rse _ / Eave Closure 10 in. _ 2. FlatUw Profile Tile scia Nail through plastic cement (when required) �Paddy (Beneath Tile) Underlayment y 10in.x - 2 in wide Battens optional 10 in. tin. Eave Closure Eave Course Fascia Medium Profile Tile Nail through plasticce (when required) Paddy (Beneath Tile) Underlayment O lr -t 10 in.x 2 in. wide Battens -- optional'-_ i Eave Course `" Fascia Weephole 10 in. 2 in. Eave closure f'►` Drip edge High Profile Tile NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET® AH-160 Revision 9: 09/29/2020 Page 7 of 10 ON EMO I etc. 10.3 DETAIL #3: Interdependent, Two Paddy: Nail through plastic cement Paddy (between tiles) (when required} i Battens optional i ° Paddy (undertile) Single paddy on top of tile x4in. - S ing le pa d d _ under til Single paddy - on underlayment 2 x 4 in. _. q 0 10in.� ` 2 m. Fascia Eave Closure Flat/Low Profile Tile Nail through plastic cement (when required) Battens optional 4 Sin la add 9 P Y on tap of till �4 '4x4in. Single paddy on underlayment, `10;n. 2 in. J IEave Medium ProfileTile Nail through plastic ce Single paddy undertile (when required} Paddy (between tiles) Battens optional v Paddy (under tile) V Single paddy onundarlayment x 4 in. Single 2x4in. paddyon, top of the Eave C o u rse Fascia Weephole 1Din in. Eave closure •�. Drip edge edge High Profile Tile paddy under tile Paddy (between tiles) /Paddy{undertile) Y _ x 4 in.'-. ",— Eave Closure Fascia NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-119 POLYSET® AH-160 Revision 9: 09/29/2020 Page 8 of 10 ON EMO I etc. 10.4 DETAIL #4: Two Piece Barrel (Cap & Pan) Tile: 1) Place enough adhesive to achieve 65 to 70 sq.in. Steep pitch applications in contact with the pan tile. (when required) 2) Turn Covers upside down. Place adhesive 112 in. to 1 inch in tram outside edge of cover We. Install cover tile. Ensure 20 to 26 sq, in. contact area on each side of cover tile. IUUnderlayment Sheathing Eave closure (motar shown) Weephole Fascia Board Remove top portion of the eave course cover tile. Abutto second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile 10.5 DETAIL #5: Hip and Ridge (independent placement): A bead of ICP Poly 2LAR-16U may be applied above the field To attach h4Vridge tiles, a bead of ICP PolysetOAH• 160 may the surface oa both sides of the bipkidge board or galvicized be applied down the centr of the hiplridge hoard or gahinized metal frame to provide weathetblocking. frame. NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET® AH-160 Revision 9: 09/29/2020 Page 9 of 10 ON EMO I etc. 10.6 DETAIL #6: Hip and Ridge (interdependent placement): - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET® AH-160 Revision 9: 09/29/2020 Page 10 of 10