Loading...
HomeMy WebLinkAboutProduct Approval Window Single HungFlorida Building Code Online Page 1 of 5 Lag i.. ia DCIS Home Log in User RegePatlon Hot Topics submit surcharge Stats & Facts Publications FBC Staff SCIS Site Map Links Search ' }Product Approval USER: Public User r rt Frcduct Aoo, oval Flenu >.PrYud er Aoslicaticn Search > ApJli:ation Liz i > Application Detail FL : FL14911-R7 Application Type Revision Code Version 2014 Application Status Approved '4 I � Comments Archived, Product Manufacturer q' Silverline Building. Products Corp. Address/Phone/Email One Silverline Drive North Brunswick, NJ,08902 (651)264-4178, Nicholas: Kopp@andersencorp:com Authorized Signature Vivian Wright '. rickw@rwbidg consultants.dom Technical Representative Jon Berrian Address/Phone/Email One Silverline Drive North Brunswick, NJ 08902 (.732) 4354000 jo.nberrian@slbp.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florlda Registered Architect or a Licensed, Florida Professional Engineer -' Evaluation Report - Hardcopy Received Florida Engineer -or Architect Name who developed Lyndon F.'Schmidt, P.E. the -Evaluation Report Florida License PE-43409 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality.Assurance Contract Expiration Date 08/03/2021 Validated By Ryan 7. King, P.E. Validation Checklist -Hardcopy Received Certificate of Independence F_i.4trij Y Ci:; i=:_r'xi r-:fir_?rienen^en eiZl.rdT Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/C5A/101/1.S.2/A440 2008 AAMA/WDMA/CSA/1G1/I.S.2/A440. 2011 ASTM D1929 1996 ASTM D2843 1993 ASTM.D635 1996 ASTM 0638 1996- ASTM E1886 2005 ASTM E1996 2009 ASTM G26 1995 TAS 201, 202 and 203 1994 T'le copy https://floridabuilding.org/pr/pi _app_dtl.aspx?param=wGEVXQwtl)quZRj59%2fDrx9lb... 10/30/2017 Florida Building- Code Online Page 2 of 5 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date. Validated Date Pending FBC.Approvai Date Approved Date. Revised Summary of.Products Go to Page ;Florida Licensed Professional Engineer or Architect 7 En l = lyr:ler.r `t}F Standards:nd` Method 1:Option D 04/02/2015 ,04/13/2015 0411612DIS 06/23/2015 10/21/2017 41 d Page 1/ 26 0 r FL # Model, Number or Name Description 14911.1 a: S 2900/4900 - M 2901/4901 Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for usein.HVHZ: No =Li 911 R7 iI Irst 14 n11.1.odf Approved for use outside HVHZ: Yes . Impact Resistant* Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 14911.11 for Design Pressure Ratings, any additional use limitations, installation instructions and =L1.-9 i. 22 AE Eval 14l'.IJ -odf Created by Independent Third Party: Yes product particulars. 14911.2 b. S 2900/4900 - M 2901/4901 "Oriel" Extruded Vinyl Single Hung Window With Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ: No Fir:7R7 ii i55ti=t5i.i.'.oat Approved.for use outside 14VHZs Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent: Third Party:. Yes Design Pressure: NIA Evaluation Reports Other: See' INST 14911.2'For Design Pressure Ratings, any. 4 � a;`i . R7 AE Tv r s i,.i.?.qLr additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14911.3 c. Series.2900/490'0 Models Single Hung Extruded Vinyl Window with Nailing Fin 2001/4901"Weather Stopper" Limits of Use Installation Instructions Approved for use in HVHZ: No FL14 S 1 ; R7 11 Insi i I9g 1.3.r;Lit Approved for use outside HVHZ: Yes. Verified By: Lyndon F..Schmidi, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party:.Yes. Design Pressure: N/A� Evaluation Reports Other: SeerINST 14911.3 for Design -Pressure Ratings, any �:i_14911 R7 AE Evai 1491.1. 3.eif additional use limitations, installation instructions and Created by Independent. Third' Party: Yes product particulars. (Note -See 14911.24-forWind Zone 4 and HVHZ Impact Product) 14911.4 .d.-S-2900/4900- M 2902/4902 Twin - Single Hung Continuous Head and Sill Extruded Vinyl Window with Nailing Fin Limits of use Installation Instructions Approved for use in HVHZ: No FL14f�11: R7 ii 1n;t 119i i:.liGf Approved for use outside. HVHZ:. Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created'by Independent Third Party: Yes Design. Pressure: N/A Evaluation Reports Other. See INST 14911.4.forDesign Pressure Ratings, any FLI49 L R7 AE­ F.:•al +' g i i.a.mif additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 149.11.5 e. S.2900/4900 - M 2903/4903 Triple- Single Hung Continuous Head and Sill Extruded Vinyl Window with. Nailing Fin Limits of Use Installation Instructions Approved for use In HVHZ, No : ! :4n:t1 F7J.1,Ytnst 1YU.i Approved for use outside HVHZ: Yes Verified By:'Lyndon`F. Schmidt'. P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 14911.5 for Design Pressure Ratings, any hops:/Lflo.'ridabuilding.arglpr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj 59%2fDrx2lb,.. 10730/2017 Florida Building Code Online Page 3 of 5 additional use limitations, installation instructions and EL!491:::7 Ae F 11149.1.5.ndi product particulars. Created by Independent Third Party: Yes 14911.6 f. S 2900/4900 - M 2901/4901 Single Hung Extruded Vinyl Window -Flange with Strap Anchoron Sill Limits of.Use Installation Instructions Approved for use in HVFI& No FI 1a3i •. R7 ! ins± 101.1..6_or_f Approved for use outside HVHZ: Yes Verified By Lyndon F. Schmidt, P.E. 43409 impact Resistant:,'No Created by Independent Third Party:'Yes Design Pressure: N/A Evaluation Reports Other. See INST 14911.6 for Design Pressure Ratings, any FL14PI i n7 AE Ev al 1 s :.o.0d additional use limitations, installation instructions and Created by Independent Third Party: Yes 14911.7 g. S 2900/4900 - M 2902/4902 ( Twin - Single,Hung Continuous Head and Sill Extruded Vinyl Window -Flange with Strap Anchor on Sill Limits of Use Installation Instructions Approved fer use in HVHZ: No Approved for use outside HVHZ: Yes verified By:- Lyndon F Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports other: This Product Is No Longer Offered by Silverline ten; s P7_ aF FV`1. 149�1,,7 Building Products, Corporation (See 14911.7. - 2010 FBC Created by Independent Third Party: Yes version for Historicai Documents regarding this Approval) 14911.8 h. S 2900/4900 - M 2903/4903 I Triple -Single Hung Continuous Head and Sill Extruded Vinyl Window -Flange with -Strap Anchor on Sill Limits of use Installation Instructions Approved for use in HVHZ: No 1 ^1491 I. '' I! IN^T 14911.8.edf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design, Pressure: N/A. Evaluatloh.Reports .Other: This Product is No Longer Offered by Silverilne i _!49 ', P= EVAL ice`-1==.i3_tidt Building Products, Corporation (See 14911.8 - 2010 FBC Created by Independent Third Party: Yes version for Historical Documents regarding this Approval) 14911.9 1. Series 240014900 Models { Extruded Vinyl: Single Hung Window 2901/4901 "WeathecStopper" Limits of. Use Installation Instructions .Approved for use in HVHZ: No -Lle9 R7 T1 In;`'14`-i Approved for use outside HVHZ:'Yes Verified By Lyndon F. Schmidt, P.E. 43409 impact Resistant: Yes Created by Independent Third Party: Yes DesignPressure; N/A .Evaluation.Reports Other: See INST 14911.9 for Design Pressure Ratings, any F; ? 7 AF Eval = 91 .G. odi additional use'limitations,'Installatlon instructions and Created by. Independent Third Party: Yes product particulars. (Note- See 14911.25.for Wind Zone 4 and HVHZ'Impact Product) 14911.10 j. Series•2000 / Model 2001 Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use In HVHZ: No LLR7 iI 1nst i!L"11., 0-nof. .Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other. See INST 14911.10 for Design Pressure Ratings, " t :-2-'s P7 Ai: Ev?l i4911.I Ox6f' any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14911.11 k Series 2000 / Model 2002 Extruded vinyl Twin Single Hung Window (Continuous.Head and Slll with, Integral Mullion) Limits of Use Installation Instructions Approved for use in HVHZs No .�''. ' Z i i Irt iC�j..,>r•.:_4.: Ls�.i� Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 14911:11:for Design Pressure Ratings, FL14 11 R7 A Eva1.149i 1:11:dadf any additional use limitations, installation In and Created by Independent Third. Party: Yes product particulars. 14911.12 1. Series 2000 / Model 2003 I Extruded Vinyl Triple Single Hung Window (Continuous Head and Sill with Integral Mullion) Limits of Use Installation instructions Approved for use in HVHZ: No L 4911 R7 Ti Ins 1.1 49112.cdf Approved for use outside HVHZ: Yes Verified By:, Lyndon F.,Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INSf 14911.12 for Design Pressure Ratings, 4y11 R7 AR: Created by Independent Third Party: Yes https://floridabuilding.org/pripr app_dtl.aspx?paramwGEUXQwtDquZRj590/o2#Drx21b... 1013.012017 Florida Building Code Online Fage 4 o1 � any additional use limitations, installation instructions and p"roduct particulars. Extruded Vinyl Single Hung Window -Flange Y4911 13 m. Series 2100 / Model 2111 Limits of Use Approved for use in HVHZ: No1.1'•nI Installation Instructions Approved for use outside. HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: NjA Other: See INST 14911.13 for Design Pressure Ratings, Evaluation Reports L"?G11 ?J E Eva! . •: i1..;3.onr any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14911.14 n. Series 2200/2300 -Model extruded vinyl Single Hung Window - Nailing Fin Z201fZ301 Limits of Use installation Instructions Approved for use in HVHZ: No F, i­911 R7 11 In;t 14911-14.3vi Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 impact Resistant: No Created by Independent Third Party:, Yes Design Pressure: N/A Evaluation Reports other: See INST 14911.14 for Design Pressure Ratings, L ? AE rval 1491a.14.ndf any additional use limitations; installation instructions and Created by Independent Third Party: Yes product particulars: 14911.15 o. Series 2200/2300 - Model Extruded Vinyl Twin Single Hung Window - Nailing Fri Head and.Sill with Integral ,Mullion) 2202/2302 (Continuous Limits of use Approved for use in HVHZ: No Installation Instructions .'? , a1 R3 U inst 101i-�' •nafr Approved for use outside HVHZ: Yes Verified By: Lyndon F Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes 'Design Pressure: NIA other: See INST 14911.15 for Design Pressure Ratings, Evaluation Reports Yi_14911 F:7. }�= -c�'ci 14911.15::5df any additional. use limitations, installation Instructions and, Created by Independent Third Party: Yes p. Series 2200/2300 - Model Extruded Vinyl Triple Single Hung Window - Nailing Fin 2203/2303 (Continuous Head and Sill with Integral Mullion) Installation Instructions e in HVHZ:No FLApprovedd 9;': 37 1i Ins: 14�1.1-se outside HVHZ• Yesed By: Lyndon F. Schmidt, P.E: 43409 ted by Independent Third Party: Yes nt:.No Design Pressure: N/A ation Reports jand6reated Other: See INST 14911.16 for Design Pressure Ratinr y AE E�rzl 4011.' c.r,•ii any additional use limitations, installation instructions by Independent Third Party: Yes product particulars. 14911.17 q. Series 2907 Model 2907 Single Hung Extruded Vinyl Window with Nallin;g Fin In. Limits Of Use Installation, Instructions Approved for use in HVHZ: No =? - E ' iI ins ? iFi I•.17.nrir Verified By: Lyndon F. Schmidt, P.E. 43409 Approved.for use outside HVHZ: Yes Impact Resistant: No Created by Third Party:. Yes Design Pressure: NIA Evaluation Reports Other: See INST 14911.17 for Design Pressure Ratings, a-' t 7 Ar- Fcal 1' 1!.17.oar any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14911.18 r. Series 2907 Model 2907TW Twin - Continuous Head & Sill Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use. installation Instructions Approved for use in HVHZ: No ?^?? n, a ins'-_ 1+1 Y2.1at-df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant No treated by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports other: See INST 14911AB for.Design Pressure Ratings, °_ t R7 Ar F� a1 s 11 S.nd� any additional use limitations, installation instructions' and Created by Independent Third Party.: Yes product particulars. 14911.19 s. Series 2907 Model 2907TR Triple - Continuous Head':& Sill Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ: No L3 �i:1 R IP=n 4 1.1;.19 nd; Approved for use outside HVHZ: Yes Verified By Lyndon F Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INSL 14911.19 for Design Pressure Ratings, R7 AE Evai 1-9I1.1Ing any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. https://floridabuilding.org/pr/pr= app dtl.aspx?param.=w(3EVXQWtDquZRj59%2fDrx2lb-.. 10/300017 Florida_ Building Code Online Page 5 of 5 14911.20 1 t. Series 70 Model 2127 1 Extruded Vinyl Single Hung .Window - Na)lipg Fin Limits of Use Installation Instructions Approvedlor use4n HVHZ: Yes F! 1=�11 r? H Inst 1-19 Approved for use.outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E..43409 Impact Resistants No. Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports, Other: See INST 14911.20 for Design Pressure Ratings, EL- qj-, R7 r Evat,1.4911.20_odi any additional use limitations, instailation instructions and Created by.independentThird Party: Yes Go to Page sa:k 1'tg Contact US;; Z60i tilair StQ66 Road, TaliahasseeTU32399 Phone: e50.487-1924 19) 6 Page 1/2.& 6 The State pf Florida Is,an.AAfEEO employer. Coovrfdht 2007-2013 State of Florida. ::•Prlvaty Statement::: Accessibility Statement Refund Statement Under Fiorhla raw omail addmssos am pubec romrds. If you do not want your (-mail address released In'lresponso to a public -records reoueti4 do not send electronic mall be this entity. Instead, contact the office by phone or by traditional. mail. if you have any questMns,please contact 050.487.1395.'Pursuant to Section 45S.275(1), Florida Statutes, eAetifve. October 1, 2012,-licensees licensed under Chapter 455. P.S.'must provide the Oepanment with an email address If they have one. The omalts provided may be used foroft-pal.communiration with the ricensee. However email addresses are public record. If you,do not wish to supply personal address,. please provide the. 0epartment.wfth an email address which can be made available to the public To determineaTyou area licensee under Chapter 455, F.S., please dick, here Pioduct Approval Accepts: ca {_�� c � re 9i-, Card Safe https://floridabuilding-org/pr/pr app dtl.aspx?param=wCTEVXQwtDquZRj59%o2fDrx2lb... 10/30/2017 Florida Building Code Online Page 2 of 3 Equivalence of Product Standards Certified By Sections. from the Code Product Approval Method Date Submitted Date Validated 'Date Pending'FBC Approval Date Approved .Date Revised Summary of Products Go to Page : l NO Florida Licensed Professional Engineer or Architect 71, R EMji- FOUivalencca OX Standarrla.r,df Method 1 Option D 04/02/2015 04/13/2015 04/16/2015 06/23/2015 '10/21/2017 -W 6 Page Z / 2 -' i'Ii FIL # MModeli Number or Name Description 14911.21, u. Series 70 NEodei 2127 Extruded Vinyl Single Hung Window - Flange Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL14911 R7 11 Inst 14911.21:Ddr Approved for use outside HVHZ: Yes Verified By: Lyndon.F: Schmidt, P.E. 43409 impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other.:See INST 14911.21 for Design Pressure Ratings, F! 145+ i R7 A - Eti ai !4q+ i.21.ndi any additional use limitations, installation instructions and Created- by Independent Third Party: Yes product particulars. 14911.22 v. Series 70 Model 2127 Limits of'Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant 'Yes Design Pressure: N/A Other., gee INST 14911.22 for Design Pressure Ratings, any additional use' limitations, installation instructions and product' particulars. Hung Window - Installation Instructions P,7 U Ina 14o+1.2 i.nd` Verified By: Lyndon F; Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports. 911 A' A cy'1 +rgI1.72.0cf Created by Independent Third Party: Yes Fin 14911:23 w. Series 70 Model 2127 Extruded Vinyl Single Hung'1Nindow - Flange Limits of use Installation Instructions Approved for use in HVHZ: Yes FL14913 R7 1I rnst 1491 i.23.DdY Approved for use outside HVHZ: Yes Verified By: Lyndon F.;Schmidt, P.E. 43409 Impact Resistant -.'Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 14911.23 for Design Pressure Ratings, FL14911 R7 AE Eval 14911 73 odf any additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. 14911.24 x. S,2900/4900 -.M 2901/4901 Singte.Hung extruded Vinyl Window with, Nailing Pin Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Verified By:,Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: NIA Evaluation Reports Otheri See INST 14911:24 for Design Pressure Ratings, F'_1491 i P.7 N'c %vat 1<9_3,24.!;df any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. 14911.25 y_ S, 9900/4900 - M 2901/4901 Single Hung EExtruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ: Yes FLI491.I R7 Ii [n;t 1-97I*25.,,df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant. Yes Created -by Independent Third Party:. Yes Design Pressure: N/A Evaluation Reports Other: See INST 24911.25 for Design Pressure Ratings, -r_1. i y • i_ R7 A .F 'ciai 14g3.1 .31. f any additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars_ Go to Page = 6.� Page 2 / 2 o hops://floridabuflding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquZRj59%2#Drx2lb:.. 10/30/2017 "elver ind byAndersen WINDOWS e D,00-RS SERIES 70 ® MODEL 2127EL EXTRUDED VINYL WGIF HUNG WhYDOW cal or, w1out FLAIYGE "NON -IMPACT' - GENERAL NOTES 1. Thisproduct has been ovdugteci and is incomplionce sv1h the 5fh Edition12014) Florida Sutloing Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details Anchorembedment to base material shall be beyondwall dressho.orstucco. 3_ When used in the °HVI•IZ"_this product is requited to be projected with anImpact resistant covering that compilesvrilh Sedffon 1626 of the FBC. 4. When used In areas outside of the "HVHT" requfingwind bome debris protection IN's product Is required to be protected with on impact resistant covering shot compiles with Section 1609,1.2 of fire FBC. 5. For 2x stud iroming.ponslruciion, anchoring of these units shall bedhe same as that shown for2x buck masonry construction. 6. Site conditions that deviate from the detats of this drawing require further engineering analysis by Ilcensed.engineer or registered architect. J. This product meets water infilirailonrequirements for`HVHT'. TABLE OF MWENNS SHEM DESCRIPTION' 1 Typica _efevation,,designpressures &general notes. 2 Horizontal &vertical cross sections 3 ... Horizontal & vertical cross sections. q Buck and rams anchoring 6 Bill of mafenals, glazing'tle ails &components 5325" MAX. OVERALL FLANGE WIDTH I- — 52.00" MAX. OVERALL FRAME WIDTH --I � s X o .J o 0 / r h � o x LL OVERALL : ' ."FLANGE OVERALL MAk' GLASS DESIGNP.RESSURE (PSFj' ` . ' FRAME D L O:'_.t TYPE PO$frIVE NEGATNE ; DIM@NSION , ';P1 ENS1OJV DIMENS1oN 53.25Y x 63,5W 52:00" x 62.59' 47.69" x 28.25" , +62.8 -65.0 G1, 53.25" x 74.03" 52.00" x 73.00" 47.69" x 33.50" G2 +55.0 40 0 ft IL.-14911.21 I 27 41 .•m' a �� ti��� n NOTE 1. LOCATE OPERATING SASH LOCKS 7;5" _ • • � v ' toll / FROM EACH MD Or THE ACTIVE MEETNGRAIL, FASTEN WITH (2)USX 314 SELP TAPPING SCREWS. z 23 :7 -e° .�" 'j'' rc•'t�0 e n • 2 KEEPER FFASTEN ROM EACH �. 4��I�TT{11 �i, ,`����` « n,m' i O EN OMESASM INGRAIIH WITH 06 314" SCREWS. 2d 00 a 7 (2) X t E$ zu lllJJJJ a: CIL p —O .a E v z P. IN [XT(RIOR TERIOR SEE 32 s x 3.1: 11 NoTE 2 10 -SE[ z NOTE 1 17 i'/ 14 g C Jy q.12 OJ S 23 ABOVE THE MEETING RAIL ABOVE T14C MEETING RAIL 2g 78 27 -u' ¢ 26 INTERIOR 26, �M; • P n E ai o •. 9 34. 33 36 34 17 G2 G7 7 15 • 20 / �, m Ill d 15 � o✓ z • Erxl, n • [Juo ° • E 24 / EXTERIOR 25 24 • , ., v p 2T MME':9 10 30' 12 . i SM . N.T.S. 25'1 1 h_► Q v •' V I I.114" MIN. ? • - wv: ti4 JK m 37 BELOW THE MEETINGRNI BELOWTHEMMINGRAIL 37 EM9..TYP. lFS 3 _ 1.114'MIN. CMB. TYP, NONZONTAL CROSS SECTION 2_ VERT1CALCROSSSECTION , 2 ; Shown w/ 2X buck ow,Kvroe l FL-14911.21 ro N 2' Shamw/2Xbuck, 9au 2 OF J (� MEETING RAIL INTERIOR Mm- ABOVE THE MEETING RAIL a Y D V o D• (�14,71jQNl�' D t(�//1rWtlR4� Yq {� — EXTERIOR — 22 � THE MEETING RAIL BELOW TFIE MEE ING RAIL .3g CMD. TYP. e3HORIZONTAL CROSS SECTION M Shownw/IXbuck FRAME SHOWN w/OPTIONAL lI FLANGE ITYP TIRS SHEET) I �U14+MUUU1 G4141U141i94�i NOTE: I: LOCATE OPERAIWG SASII LOCKS 79 FROM EACH E14DOF THEACBVE MEEHNG RAIL, FASTEN WRH (2) 118 X 3/4- SELF TAPPING SCREWS: 2, LOCATE SASH KEEPER 6S FROM EACH ENO OF THEMEE 1NG RAIL, FASTEN WITH (2( IIGX3/,"SCREWS. I (\ VERTICAL CROSS SECTION 3 Optimal masonry sla �4� VERTICAL CROSS SECTION `3� Opiioncl mOSOMY sill I d EXTERIOR ,I II—._ n�, INTERIOR 0 VERTICAL CROSSSECTION 3 ShaWnW/IX buck -:: 9 T nc on Us 3 'Atl 1 11 " K It FL-1491 T.21 13 2X BUCK MASONRI OFENINC, VMAX, 2X SUCK IX BUCKJ V BUCK TYR. FRAME MASONRY OPENING 2XBUCK k37 Ix ou g3 I Tyrr. BUCKANCHORING FRAME ANCHORING MASONRY 52" X 73" MAX CONCRETE ANCHOR NqTES,-, I. cdncrefoonchorlocaffonsolinDcorners maybe cajr.usfod.fornatntaln the min. edge d(slonce to marlariolats. 2 concrete anchor locations noled as "MAX. O.C. (TYP.)"must be adjusted to maintdn the min. ' edge crislance to afortcrJotrits, adcUllonalconcrelis anchors may be requlfqd to ensure the "MAX.O.C. (TYPJ' dimensions are not exceeded. 3. Concrete anchor fable: AlIN' ".f:lqARAq�:F TO;MAtONRY*-, 11w TAPCONO 1/4' 1 rzLCO ULT.MC:0 SCREW INSTALLATION NOTES. 0 Valance, I"o'c. spacing or ,,njntmum51u-edgapls!oncel- on wood crews,lo prevent Ihe splitting of Wood, -- Mr ff 2XBUCK FRAME MASONRY OPENING IX BUCKf IXBUCK 2X BUCK C t IXBUCK IYP. FRAME ANCHORING 42! X 0 MAX 0,0 ............ % �d d ,z Ad BILL OF MATERIALS - ITEM DESCRIPTIOAI MATERIAL 1 EXTRUDED PVC MAIN FRAME 14524611'• PVC _ 2 EXTRUDED PVC SILL #52-2673' PVC' 3 EXTRUDED PVC SASH INTERLOCK GLAZING BEAD'411257 RVC 4 ' EXTRUDED PVC MEETING. RAIL R52-29D7t PVC 5 EXTRUDED PVC TOP LIFT RAIL 052-2949` PVC 6 EXTRUDED PVC BOTTOM RAIL 052-2905'� PVC 7 EXTRUDED PVC STILE 4152-2905' PVC 9 EXTRUDED PVC GLAZING BEAD VERL & HORT. 4452.1227' PVC 10 OPERABLE SASH LOCK, 012.2241 - I'1 _ SASH KEEPER /112-2240 STEEL 12 FIXED MEEIING RAIL REINFORCEMENT 1150.2608 ALUM• . 14 LOCK RAIL REINFORCEMENT 1150-2609 ALUM. _ 15 BOTTOM LIFT RAIL & SASH REINFORCEMENT'4150.2967 ALUM. 16 WINDOW SCREEN" - 17 WEATHERSTRIP PILE W/FIN 367 x .270,,LOCK RAIL & SASH (ULTRAFABL 18 WEATHERSTRIP PILE W/FIN .187 z .230, FIXED MEETING RAIL (ULTRAFAB) 19 WEATHERSTRIP PILE W/FIN .1 B7 x .150, SILL JULTRAFABI 20 RIP VINYL BULB .18T' X.37S' O AMESBURY 22 ,GLAZING COMPOUND (DOW Hl 199) . SILICONE 23 B 10 X 2' PPH SMS __. STEEL 24 1/R'X2.3/4"PFHELCOORITWCONCRETE SCREW. _ STEEL 25 2X BUCK SG — 0.55 WOOD 26 1/4" MAX. SHIM SPACE 27 MASONRY - 3,000 PSI MIN, CONCRETE CONFORMING TOACI 301 OR HOLLOW BLACK CONFORMING TO ASTM C90 CONCRETE. 29 1X BUCK WOOD 30 [INTERCEPT SPACER STEEL 31 SASH KEEPER #12-5550:030 STEEL- 32. __ OPERABLESASH'LOCY" 012•SKQI-100 STEEL 33 TILLLATCH 1107.76625 STEEL 34 08 X 1" PPH SMS STEEL 35 SUPERSPACER _ _ _ BUTYL 36 TILT LATCH (HP-1 MFG. BY ASHLAND) STEEL_ . . 37 1110 X 3° PPH SMS STEEL 38 I_M' X 4",PPH ELCO OR ITW'CONCRETESCREW STEEL - THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS7"OR WINDOWS ARETO BE PRODUCED BY EXTP,UDERS'LICENSEES IN'AAMA CERTIFICATION PROGRAMS'EOR RIGID PVC EXTRUSIONS". d I I✓ --I- 1.1 6 EXTRUDED PVC BOTTOM BAIL 7116 7116 1Hic 518'dVERALL GLASS 1/8"ANNEALED AIR SPACE IIB'ANNEALED GT GLAZ GDEf 1 5/8° OVERALL GLASS 1/8"ANNEALED G2 GLAZING DETAIL d O14 LOCK RA►L TOP Roinlorcemanl I 0.065" L� } :4 .�- I----D.9r 0 4 E iRUDED PVC MEERNG RAH O EXTRUDED PVC SBlE 5, E RUDED PVCaDP LIFT AIL d AIR SPACE 11WANNEMED aR 0.78 VM sL, 9z I I W OqAZIMG REAP ` Sash Intedock ' o. z z O,GIAZING (LEAD 0 a 088 0.34" c O.A35 -•-I I -- I 0 LOCKbIEEHNGRAIL BOR'OAALIFT.RAILBSASH . 14 Rolnlarcomenf 15 Ralaforcomonf-� II 0.055" O O Optional Flange ---Optional Flange OPVC MAIN FRAME v 2 PVC SBL 0 Z. I se 10 30 12 u�+ .14T.S, JK '^ c w.. LFS rm"; Na FL-14911.21