Loading...
HomeMy WebLinkAboutREV. Floor PlanDEMOLITION NOTES: I VERIFY LOCATION OF ALL NEN NALL5 PRIOR TO REMOVING ANY EXI5TIN5 CONSTRUCTION. 2. VERIFY ALL BEARIN6 CONDITIONS PRIOR TO REMOVAL OF ANY WALLS. 3. PROTECT ALL EXISTIN& AREAS THAT ARE NOT TO BE DISTURBED. 4. ALL WORK SHALL BE DONE IN ACCORDANCE KITH ALL LOCAL CODES AND ORDINANCE5. 5. VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO STARTING WORK. IN CASE OF ANY D15CRIPANCIE5 BETVeEN THE PLANS AND EXI5TiNG FIELD CONDITIONS, NOTIFY THE ARCHITECT IMMEDIATLY. NEN 2-54 SH. X Ij" STORE DR. '40Z-55.8 P517. TO REMAIN (TEMP. 6LA55)' +402/-53.5 P5F. REV. FLOOR PLAN EXI5T6. NINDON TO REMAIN EXIST6. WINDOW TO REMAIN EX15T6. WINDOW TO REMAIN DESIGN M"FIGAMIN FOR WIND LOAD G0IlI"MIA4NGE: STA7!'M We I CERTFY THAT, TO THE BEST OF MY KNOYLID6E AND BEAM, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESI&DED TO COMPLY WITH TFE APPLICABLE STRI1GTLWAL PORTION OD THE BUILDING CODE AS ANENIDED, ADOPTED, AND ENFORCED BY ST. LUCIE COUNTY BUILDING DEPARTMENT. d ALSO CERTIFY TWAT THE STRUCTURAL COMPOFEr1T5, SYSTEMS. AND RELATED ELEMENTS PROVIDE ADEQUATE RC515TANCE TO THE WIND LOADS AND FORCG-5 SPECIFIED BY TI r. CURRENT CODE PROVISIONS. I FERRY ACCEPT RESPONSIBILITY FOR THE STRLIOTLRAL. DESI&N. VNIM FXPAWMIM slid A NOM.YS& CODE EDITIONS: 2014 FLORIDA BUILDING CODE 5 EDITION (RESIDENTIAL) ASC.E T-10 2011 N.E.C. BUILDING DESIGN AS: ENCLOSED BASIC WIND SPEED: WEST OF TURNPIKE EAST OF TURNPIKE X __ BUILDIN6 CATE60RY: I II X III —IV WIND IMPORTANCE 1.0 FACTOR: INTERNAL PRESSURE .15 COEFFICIENT: &ARA&E DOOR SEE FLOOR PLAN FOR WIND DESIGN PRE55URE: PRESSURE' WINDOW DESIGN SEE FLOOR PLAN FOR WIND PRESSURE: PRE55LRE-5 FOR NINDON5 AND DOORS IN INT. AN REND ZONES WIND SPEED 1'10 MPH, EXPOSURE: G IMPACT PROTECTION APPROVED SHUTTERS (EXTERIOR — OPENIN65): IMPACT RESISTANT X &LASS (MUST BE INDICATED ON PERMIT DOCUMENTS FOR ALL RE-51DENTIAL / COMMERCIAL BUILDIN&5, .ALTERATIONS, AND RENOVATIONS) NOTE: ACTUAL DE516N PRESSURES FOR ALL EXTERIOR NINDON5, DOOR, GARAGE DO(ARS, AND SIMILAR ENVELOPE ELEMENTS MUST AL50 BE INDICATEDON CONSTRUCTION PLAN5.5 DEC 0 6 2017 PER 7a317TIi,K: St. Lucie CCLM,y, FL S L1(S• RFVr,WED FOR C7, T • NCE zti.vlE�;.rr ��a DATE _ PLA.'NS 1 ,"1) -�ZT c -v K2 PT ON JOB OR NO INSPECTION lN'ILL SE XADE. DRYWALL ON 1' x 2' PT • 16" OCR - SA INsj- IX4 PT CALLK SILL ALUM. WINDOW FRAME ON I'X3' PT. AW-HORED TO CONC. ELK. WALL MV 1/4' TAPCON SORE ( MIN 3' LONG ) CN.LK 5T1LC0 FIN5H ON CONC. I� WINDOW JAMB DETAIL SCALE 3.4' . I''-W PATCH EXISTS. DRYWALL TO MATCH EXIST&. R-510 INSTIL, 2' X PT. PT, SOLID WOOD BLOCKIN& ANCHORED TO CONC. WAIL W/ J" TAP CON SCREWS AT 12' OC. ALUM. WINDOW FR.AHE ON I'X 5' P7. ANG+ORED TO CONC. ELK. WALL W/ 1/4' TAPOON 5CAM45 ( MIN 5' INTO COW.) 5TK.C.O FINISH ON COW- BLK- 02 WINDOW JAMB DETAIL SCALE 5.4' • 1'0" PATCH EXtST&. DRYWALL TO MATCH EXISTS. R-3D INST_ I'X4' PT. OAILK 2 X WOOD DOOR JAMB t LL HEADER ON IX4 PT. ELKS ANCHORTO COW-. ELK. W/ 114' LONS) SCREWS MIN. 4' LONS DOOR WITH WOOD JAMB. FW 1 1/2' PAIR OF 8VTT HINSES STUOC.O FINISH ON Cow— BLJC ® DOOR JAMB DETAIL SCALE 3.4' . 1'-0" &ARY FOWELLL. ARGHITECTURE AND PLANNING 16 SOUTH RIVER ROAD SEWALLS POINT, FL. 541% OFFICE: -M2-225-1755 tu Q Q D� < LL < Q - 0 } 1- QA O �v v w lu 0 ND N DRAM B1 WGF iA vc4c GV By WGF DATE NOV. :SO, 201-7 SCALE AS NOTED 0 A CEALEO FASTENERS OR ATTACHMENTS ARE THE rRE IqtIjyor CONTRACTOR OF R65ARI) '�RE$i! PLANS AN6 ALL PROPOSED WORK Afi T S Ll"nGb BY FIELD INSPECTORS THAT . t CIESSARV IN €URDLR TO COMPLY WITH ALL A"UOAQIA E31;. r)g& A -I 1 OF -LJ SCALE: 1/4" = 1'-0"