HomeMy WebLinkAboutEvaluation ReportCertificate of Authorization No. M24
1.7520 Edinburgh Drive
EE�K Tampa,,FL 33647
CONCEALED FASTENERS OR ATTACHMENA313) 480-3421
i" c�I�lc.�>., 'Sic Ri/6,C S, LLC CONCEALED
THE RESPONSSLITY OF THE
CONTRACTOR OF RECORD
EVALUATION REPORT
Manufacturer: TAMKO'BUILDING PRODUCTS, INC.
P.O.Box 1404
Joplin, MO, 64802
(417) 624.-6644
hffp://www.tamko.c(im
'Quality Assurance UL'LLC (QUA9625)
SCOPE
FLORIDA BUILDING CODE, 5T" EoITION (2014)
Issued August 22, 2016
l ?I+l - o�1
ST �IJC1� COLTN 'y ALTLDENG DW HON .
REVIEWED FOR CONMIJANICiE
REVIE XED BY
DATE A777 Z ff. �O .167� p �
PLk''NS A\-DPE. 1IIT MUST BE KEPT ONJO13.
OR ATO INSPECTION RILL BE MADE.
Category:
Roofing
'Subcategory:
Underlayments
Code Sections:
1507.2.3, 1507.2.4, 1507.2:8,1507:2.9.2, 1'507:3.3, 1507.4.5.1, 1507.4.5.2, �1507.4.5.3,
1507:5.3, 1;507.5.3':*Z 1507.6.3, 1507;6.3 2, 1507.6.5i 1507.7.311507.7.3.2,1507 8.3,
1507.8..3.2, 1507.8.8; T1507.8, 1507.9.3, 1507 9.3.26§ 7FUNMD9AgLL PROPOSED WORK
'Physical
Properties:
properties. ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
REFERENCES
COMPLY WITH ALL APPLICABLE CODES,
Entity
Resort No.
Standard
Year
;PRI _Construction
Materials Technologies (TST6049)
TAP-191-02-01 REV
ASTM D 1970
2009
PRI Construction
Materials Technologies (TST6049)
TAP-192-02-01
ASTM D 1970
2009
PRI Construction
Materials Technologies (TST6049)
TAP-193-02-01
ASTMD 1970
2009
PRI. Construction
Materials Technologies (TST6049)
TAP-214-02-01
ASTM D 4869
2005e01
PRI Construction
Materials Technologies (TST6049)
TAP=215-02-01
ASTM D 226
.2006
PRI Construction
Materials Technologies (TST6049)
TAP-216-02'-03;
ASTM D: 6380
2003(2009)
PRI Construction
Materials Technologies (TST6049)
TAP-217-02=01'REV
ASTM D 6380
2003(2009)
PRI Construction
Materials Technologies (TST6049)
TAP-218-02-01
ASTM D 226
2006
PRI Construction
Materials Technologies (TST6049)
TAP-219-02=01
ASTM D 226
2006
PRI Construction
Materials Technologies (TST6049)
TAP-220-02-01
ASTMD 6380
2603(2009).
-PRI Construction
Materials Technologies (TST6049)
TAP-222-02-01
ASTM D 48,69
2005e01
PRI Construction
Materials Technologies (TST6049)
TAP-319-02-01.1
ACC 188
'2612
UL LLC (TST9628)
13CA12269
ASTM D 226
'2006
PRODUCT DESCRIPTION AND APPLICATION
TAMKOO ASTM Slate ASTM D 6386, Class.M, Type ll underlayment constructed from organic
felt saturated'
Surfaced.Rolt
Roofing with asphalt -and coated
on both sides with. asphalt and surfaced with
granules.
Min. slope;
2:12
Application:
The underlayment shall be installed
with minimum 2"
side.,laps and minimum,4" staggered, end laps and in
accordance,
with FRSA/ RI'
07230 for tile
applications.
Allowable roofcoverings: Attachment of asphalt shingle valleys and clay and
.concrete tile.
shall be permitted
in accordance with
the FBC.
T131314001.3
FL12328-R7
Page 1 of 4
This evaluation report is provided for State of Florida product approval underRule'61G20-3. The manufacturer shall notify CREEK
Technical. Services LLC of any product changes orquality assurance changes throughout the.duration for which this report is valid.
This evaluation reportdoes not express nor imply warranty; installation, recommen ied:use, or other product attributes that are not
Specifically'aadressed.herein. File Copy
CREEK-TAMKO BUILDING PRODCUTS, INC.,
TAMKO. Underlaymerits
TF-CHNICAL 91=RVIcEs, ILLIC
TAMKO® ASTM' Tile ASTM D'6380, Class.M,.Type 11 underlayment constructed from an organic. saturated
Under.1ayment- with asphalt then coated on both sides with asphalt.and surfaced with granules.
Application:
The underlayment shall be installed with minimum 2"'
side laps and;minimum,4" staggered end laps.and in
accordance. with FRSA/TRI 07230 for the
applications:
Allowable toof:coverings;
Attachment of clay and concrete: tile shall be
permitted in accordance with. the FBC..
TAMKO® Master
ASTM D 6380,•Class.S, Type IV
underlayment constructed from an ,organic felt saturated
Smooth
with asphalt then coated on both sides with asphalt and surfaced with a fine mineral.
Application:
The underlayment shall be installed along the valley
in accordance with FBC requirements.
Allowable. roof coverings:
Attachment of asphalt shingle valleys shall be
permitted in accordance with. the FBC.
TAMKOO Moisture
Self-adhered;ASTM'D 1970;, fiberglass reinforced, modified bitumen sheet membrane
Guard Plus®
with a mineral. surfacing and, a removable release film on the adhesive side.
Application:
The underlayment shall be attached by adhering
directly to the roof deck. with minimum 3-1/2"' side
laps and minimum 6" staggered end laps.
Min. application temperature:
40°F..
Allowable roof coverings:
Attachment of asphalt shingles and mechanically
fastened concrete and clay .tile roofing shall 'be
permitted in accordance with the FBC.
TAMKOO No. 15 ASTM
ASTM D 226;; Type 1 underlayment constructed from -a non -perforated organic felt'1hat is
Asphalt Saturated
saturated with,asphalt.
Organic,Felt
Application:
The underlayment shall be'installed with minimum 2"
side laps and minimum 4" end laps.
Allowable roof coverings:
Attachment of asphalt shingles, metal roofing, wood
shingles, wood shakes, and roll roofing 'shall be
permitted in accordance with the FBC.
TAMKO® No. 15 UL
ASTM D.226, Type, i underlayment constructed from.a non -perforated organic feltthat is
Asphalt Saturated
saturated With asphalt.
Organic -Felt
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" end: laps.
Allowable roof coverings:
Attachment -of asphaltshingles, metal roofing, wood
shingles,. wood shakes, and roll roofing shall be
permitted in accordance with the" FBC.
TBP14001.3 FL1=8-R7 Page 2,of 4
'This evaluation report is provided for State of Florida product approval under Rule 61'G20-3. The manufacturer, shall notify CREEK
Technical -Services, LLC of any product changes or quality assurance changes throughout the duration forwhich ;this report is valid..
This evaluation report does not express nor imply, warranty,, installation; recommended use, or other product attributes thatare not
specifically, addressed herein.
TAIVIKO BUILDING-PRODCUTS, INC.
CREEKrJ' TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKO® No. 30:ASTM ASTM D 226,; Type II underlayment constructed from a non_perforated organic feltthat is
Asphalt Saturated saturated with asphalt.
,Organic, Felt
Application:
The underlayment shall .be installed with minimum 2"
side laps and minimum 4" end laps.
Allowable roof,coverings:
Attachment of asphalt shingles, metal roofing,clay
and concrete .tile, slate shingles, -wood' shingles,
wood shakes,. and roll roofing shall be permitted in
accordance: with the FBC.
TAMKO® No. 30 UL ASTM D 226;,Type.11 underlayment constructed froma non-perforated'organic felt,that is
Asphalt Saturated saturated with asphalt.
Organic Felt
Application:,
The underlayment shall be installed with minimum 2"
side laps and. minimum 4" end laps.
Allowable roof coverings:
Attachment :of .asphalt shingles, metal roofing, clay
and concrete tile, slate shingles, wood shingles,
wood :shakes, :and, roll, roofing shall be permitted in
accordancewith the;FBC.
TAMKO®TW Metal and, Self -adhered,. flexible, ASTM D 1970, rubberized asphalt sheet membrane with. a
Tile Underlayment
-polymer film on.the surface and a removable release film.. on the adhesive side.
Application: The underlayment shall be attached by adhering
directly to the .roof deck with minimum 4" side laps
and minimum 6" staggered end•laps.
Min. application temperature: 406F
Allowable roof coverings: Attachment of asphalt shingles, metal roofing, and
mechanically fastened clay and concrete, tiles shall
be permitted in accordance with'the'FBC.
TAMKO®•TW
Self -adhered, flexible; ASTM D 1970, rubberized asphalt sheet membrane with. a
Underlayment
polymer film on the surface and a removable release film on the adhesive side.
Application: The underlayment shall be attached by adhering
directly. to the: roof deck with minimum 4' side laps
and minimum'6'` staggered end laps.
.Min. application -temperature:; 40°F
Allowable roof coYerings: Attachment of asphalt shingles and metal roofing
shall, be permitted in accordance with the FBC.
TAMKOO TAM -FELT
Altemate-to ASTM D 226, Type 1_and Type Il underlayment constructed from a. non -
perforated organic felt that is saturated :,niith asphalt.
Application: The underlayment shall be installed with minimum 2"
side laps and minimum 4" end''laps.
Allowable roof coverings: Attachment of asphalt shingles shall :be permitted in
accordance:with the FBC:
TBP14001.3 FL12328-R7 Page 3 of 4
This evaluation report is provided for State of. Florida product approval under Rule 61 G20-3. They manufacturer shall notify CREEK
Technical Services, LLC of.any'product,changes or quality assurance changes. throughout the duration for which this report is valid.
This. evaluation report.does not express nor -imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
'` = TAMKOBUILDING`PRODCUTS, INC:
CREEKr` $ TAMKO;Underlayments
J%
TECHNICAL SERVICES, LLC
LIMITATIONS
1) This evaluation, report.is not for use in the HVHZ.
2) 'Fire Classification,is nofwithin the scope of this, evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) 'Installation of the evaluated product shall comply,with .this report, the FBC; and the manufacturer's published
application, instructions. Where discrepancies exist between these sources, the more, restrictive and FBC
conlpliantinstallation detail shall prevail.
5) Minimum application temperature shall be 50°F unless otherwise noted. `Contact the manufacturer when
installing at temperatures below the minimum application temperature.
6) Deck substrates shall be clean, dry, and free ;from any irregularities and debris. All •fastener$ in the deck
shall be checked for protrusion and corrected prior to underlayment application.
7) The roof deck shall be. constructed of`closely fitted sheathing for new or.existing construction. Roof deck
shall be installed in accordance with FBC requirements.
8) Unless otherwise stated, the:minimum roof slope shall be in accordance with `FB.0 requirements..
9) All underlayments shall be installed with the roll length parallel to the,eave, starting at the eave, and lapped
in successive :courses installed up the deck in, a manner that effectively sheds water from the deck. End
laps. shall be staggered between, courses _in accordance with "the manufacturer's application instructions.
10). The-underlayment. may be used as described in other current FaC product approval documents.
11); The underayment shall not be installed :over -existing; roof coverings.
12) Contact the manufacturer regarding specific exposure limits for; each underlayment.
13) All products''listed in this report shall be manufactured under a quality -assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE -STATEMENT
The products evaluated herein by Zachary. R. Priest,-.P.E. have demonstrated compliance with the Florida :Building
Code, 5t4 Edition(2014),as evidenced:in the referenced documents submitted'by the named manufacturer.
`,e��11T1ilI��IOI
o GR>
.ti•
No 74021
:.� STATE OF tCl
�111111
CERTIFICATIONOF'I NDEPENDENCE
2016.0$:2
_. 2 09:35:39
Zachary R.. Priest, 'P P.E.
Florida Registration No.74021.
Organization No: ANE9641
:CREEK T,echnical;Services, LLC does'nothave, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technlcal Services, LLC Is not owned,' operated, or controlled by any company manufacturing ordistributing products under this evaluation.
Zachary R. Priest, P.E.;does not have, nor will acquire, a financial interest -in any company manufacturing or distributing products under this evaluation.
Zachary-R. Priest; P.E, does not have, nor will acquire, a financial interest in any other entity involved'in the approval process of the product.
END OF REPORT
TBP14001.3 FL12328-R! Page 4 of 4
This, evaluation report is,provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall.notify CREEK
Technical' Services,, LLC of any product changes or quality assurance changes throughoutthe duration'for which this report is valid.
This evaluation report does not express nor -imply warranty„ installation, recommended use, orotheir product attributes that are not
specifically addressed herein.