HomeMy WebLinkAboutfire department' SAINT LUCIE COUNTY FIRE DISTRICT PLAN REVIEW FORM 5160 N.W. Milner Drive Port Saint Lucie, FL 34983 Telephone: 772-621-3322 Fax: 772-621-3604 Web Address: www.slcfd.com Building Dept. SLC FMO Permit # B-22-57 Project Name Kenworth BLDG Permit # Address 5690 Enviroment Drive City Ft Pierce Contractor AO Construction Company Address 3535 Lake Alfred Road City Winter Haven State FL Zip 33881 Telephone (863) 299-4444 Architect/Engineer EDC Engineers Telephone F772) 462-2455 Occupancy Type Storage Construction Type 11B Square Feet 6000 Occupant Load 20 per plans Number of Stories Access Box Access Key Switch AFS Permit I FA Permit I FFP Permit General Notes 1. An electronic copy of the construction documents submitted on a CD is required. The file format shall be .pdf only. 2. All revisions, including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. A Radio coverage Pre -Survey Signal Strength inspection is required before any final inspection is scheduled. 5. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 6. Failed inspections require payment of fee prior to rescheduling of further inspections. 7. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans. 8. Fire alarm panels shall be located indoors within air conditioned space. 9. Plans and construction are subject to corrections in the field to maintain code compliance. 10. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. 11. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE CURRENTLY ADOPTED VERSION OF THE FLORIDA FIRE PREVENTION CODE IS ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. See General Notes Above and Required Revisions Below 1. Future Tenant build out will require a separate review and permit. 2. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. Provide a remote test and inspect appliance equipped with an audible/visual'indicator for each HVAC duct smoke detector. 3. Portable fire extinguishers from a licensed contractor are required. 4. Exit and emergency lights are required. Page 17 of 1❑ Reviewed by Tony Jerger Date 02-24-2022