HomeMy WebLinkAboutRevision4
OFFICE USE ONLY:
DATE FILED:
REVISION. FEE: -75
PERMIT # 21�
RECEIPT # 0 1 g U l L
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION `o�
2300 VIRGINIA AVENUE t T ( 1
FORT PIERCE, FL 34982.5652 lam-' 1 RE
(772) 462-1553
APPLICATION FOR BUILDING PERMIT REVISIO
pq
AP JI 9320 21
PROJECT INFORMATION St. Lucie Ccunry
Permitting
LOCATION/SITE
ADDRESS:
.IWa'z� 'Tanaelo 00.
DETAILED .DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION:
FL
STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #:
BUSINESS NAME: gWrletg-
QUALIFIERS NAME: — e�.r4-
ADDRESS: 9bI_,'(L)13lYhCyP b} :
CITY:P�- STATE: FI ZIP9 cl
PHONE (DAYTIME): -77 7259 - 9140P1 FAX: '77a 3q!d 9 1-+ m!
OWNER/BU1LDER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME:
STATE:
ARCHITECT/ENGINEER INFORMATION:
FAX:
NAME: Paul weich I nc
ADDRESS:1 G R4 S (-i1 B illwcre Si- <&, je IN
CITY: St- STATE: T- L
PHONE (DAYTIME): 7n -7 s 'q$ FAX:
SLCCC: 9123109
Revised 06130117
ZIP:
ZIP: ZH C $mil
M
F
PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1984 S.W. Bilt6re St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
February 18, 2022
Re: Permit# 21090484
New Residence
5703 Tangelo Dr.
Ft. Pierce, Florida
To Whom It May Concern:
Please allow approval of Dynamic Metal DMC Class 1500 26ga metal roof (FL# 27499.1)
w/ clips at 4" from end and 12" o.c. max w/ (2) #10 x 1" panclip fasters (2) per clip in lieu
of the shingles noted on the plan.
Thank you for your attention tothis matter.
Since ly:
PAUL ELCH INC.
Paul W Ic , P.E.
Fla. Reg. No. 29945
PW:ns
��. C W44c'%,
\.����P.•��C E N 8�' •'y ��''%�
ho. 29945
0 STATE OF
WOLTERS ENGINEERING
ENGINEERING, DRAFTING, CONSULTING
15211 971h Road N
West Palm Beach, FL 33412
Ph/Fx: (561) 225-1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 500 26 GA. GALVALUME 5V CRIMP 24" WIDE
ROOF PANEL (FLPA# 27499.20)
MANUFACTURER: DYNAMIC METALS, LLC
3201 SE DOMINICA TERRACE
STUART, FL 34997
To all concerned,
The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code, The panel has been
tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38-450-44 and H2686.02-
450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-
02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "5VS-HZ" dated 8/15/19, signed and sealed by Scott. Wolters, PE.
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE.
3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary
R Priest, PE.
4. Supplemental Calculations to support 5VS-HZ, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
P�o0J 9 Overall Limitations: Maximum Panel Width: 24" (nominal)
T% Fastener Spacing across panel: 12" (at Overlaps & Center Rib)
Min. Slope; Non-HVHZ: %'112" La with
( P Sealant)
3" /12" (no Lap Sealant)
SPrCIA RING IN imrA.C,C pE515rAj\if CUpTmJ xAi ,;, 5,ro rpow5, & WINl2o,.15
Option #1
Installation
Option #2
Installation
Max. Design Pressure:
-117.75 psf
-206 psf
Fastener Spacing:
4" From Ends, 16" Max. O.C.
4" From Ends, 8" Max. O.C.
Min Panel Fasteners:
#10x1 V HiLo HWH Screw
with Weather -seal Washer
#10x1 V HiLo HWH Screw
with Weather -seal Washer
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, in areas with windspeeds < 170 mph, 1" round
plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be
used to prevent galvanic reactions.
Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section
1507.1.1.1 (min).
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, in areas with windspeeds < 170 mph, 1" round
plastic caps meeting the requirements of FBC Section 1507.1.1.1 may be
used to prevent galvanic reactions.
Minimum Substrate: '/2 (15/32" min) 4-ply CDX Plywood or 3/4' solid wood planks (S.G. = .42
min) nailed to 2x rafters spaced 24" max. on center with 8d ring -shank
nails spaced 6" on center.
Note: The V wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architect/Engineer
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or"
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
5C' GXIZING IN IMPACf FE515TANT CUUAINWA15, 5TOt; PONT5, & WINPOW5
4. All panel system perimeters, penetrations, and transitions to be
flashed and sealed per the requirements of RAS 133.
5. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction,
6. Where required by the Florida Building Code, panels shall be
permanently labeled with the manufacturer's name and/or logo, and the
following statement, "Dynamic Metals FL #27499.20, DM Class 500".
Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 3rd party QA provider, to the dimensions shown on Drawing 5VS-HZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-669051.7 SSQ-4560615 SSQ2-2310920
5VC-0490718 5VC-0360516 SSQ2-2320920
Re -Roofing: The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel
may be installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1511 of the Florida Building Code.
If you have any questions or need more information concerning this approval, please contact me.
Thank you,
x S;SKSd Ba
No 62354
Scott Wolters
FL PE# 62354
�. STATE o r- l�r
APR 15 2021
.
,v.
�s. ......
;a
°
5"FCIALIZING IN IMPACT FF515`f W CU1ZTAINVVAL L5, %OF?,FIZONIS, & WiN✓OW5
>
co
co
z
0
m
n
910
m
m
0
y ES
jjjt
FL Pri F7.354
DYNAMIC METALS
CM YDLTERS
3201 SE DOMINICA TERRACE wwmdyf;aml,,irreoLn
W.4 •+,' NAME CHANGE EMS
STUART -^L 34997 FAX: (77?) 2.47-2;,66
r PALM KArM,'Ft
PH. (772) 247m?465 EMAIL 1. -
PRMTS IsSUED MR XV.0 DAM
M
RIVAROVA., Iff. RUN I 'Ib *I'll a
12"O,C. 12" o.c.'
See F
fort
S1
24!'k4aximum Net Coverage
... . . .......... . .
518
Panel Profile
VI EN E
A-,
—j 6 r, 0
<
U-j
<
u 2
< Y.
zm
u,
0 2
rq
m Ln 8:
GVS—HZ