Loading...
HomeMy WebLinkAboutAPPROVED REVISION, PERMIT REVISIONOFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT # 2202-0141 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 9415 BUNTING LN, FT PIERCE, FL 34951 DETAILED DESCRIPTION OF PROJECT REVISIONS: ADVISED DUCT DRAWING AND MANUAL J CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CMC035421 ST. LUCIE CO CERT. #: BUSINESS NAME: SEACOAST AIR CONDITIONING AND SHEET METAL INC, QUALIFIERS NAME: CHRISTOPHER LANGEL ADDRESS: 3108 INDUSTRIAL 31ST STREET CITY: FT PIERCE STATE: FL ZIP: 34946 PHONE (DAYTIME): 772-466-2400 FAX: 772-448-4416 OWNER/BUILDER INFORMATION: NAME: JOHN & BETH SNOWE ADDRESS: 9415 BUNTING LANE CITY: FT PIERCE PHONE (DAYTIME: 207-319-5488 STATE: FL ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC.- 9123109 Revised 06130117 STATE: p r f-)lA : ZIP: 34951 ZIP: 9QFF'E - wrightsofto Project Summary Date, AHU 1 By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FT.PIERCE, FL 34946 Firma: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information For: SNOWE RESIDENCE Notes; Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF DesignTD 28 OF DesignTD 15 OF Daily range M Relative humidity 50 Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18034 Btuh Structure 19126 Btuh Ducts 4794 Btuh Ducts 6146 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfin) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22828 Btuh Use manufacturer's data n Rate/swingg multipplier 0.95 Infiltration Equipmentsensibleload 24009 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2363 Btuh Ducts 1984 Btuh Central vent (0 cfm) 0 Btuh Heatingg coolingg (none) Area (ft) 1333 1333 Equipment latent load 4347 Btuh Volume (fN) 10660 10660 Airchanges/hour 0,29 0.16 Equipment Total Load Sen+Lat) 28356 Bfuh Equiv. AVF (cfm) 52 28 Re . total caI ty at 0.7� SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NA03700GOBO AHRI ref Coil FX4DNF037L AHRI ref 202024448 Efficiency 100 EFF Efficiency 13.5 EER716 SEER Heating input 6.5 kW Sensible cooling 24640 Btuh Heating output 22167 Btuh Latentcooling 10560 Btuh Temperature rise 50 OF Total cooling 35200 Stub Actual airflow 403 dim Actual airflow 1173 cfm Airflowfactor 0.018 cfmBtuh Airflowfactor 0.046 cfmBtuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved byACCA to meet all requirements of Manual J 8th Ed ' r wrigFitsofC' 2022-Feb-1615:05:20 '� ^-^^-•^ •^•^^••a -a^• RI9R-SuleQ�]Uriversa1202222.0.01 RSW6101 Pa 1 �� ...1QUICK1DoamerlslWri9Msoft HVAClSNOWE RES..np CaIc=MJ6 Front Doorfaces: E 9e Pro ect Summa Date. wrightsofta AHU 2 ry By QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@J OLCOM Project Information For: SNOWE RESIDENCE Notes: �- Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25328 Btuh Structure 19190 Btuh Ducts 6042 Btuh Duds 7448 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) none Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 31370 Btuh Use manufacturer's data n Rate/sWngg multipplier 0,95 Infiltration Equipmentsensibleload 25306 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1659 Btuh Ducts 2407 Btuh Central vent (0 cfm) 0 Btuh Heatingg coolingg (none) Area (ft2) 2046 2046 Equipment latent load 4066 Btuh Volume (it') 16364 16364 Airchangeslhour 0,27 0,15 Equipment Total Load (Sen+Lat) 29372 Btuh Equiv. AVF (cfm) 74 40 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NA03700GOBO AHRI ref Coil FX4DNF037L AHRI ref 202024448 Efficiency 100 EFF Efficiency 13.5 EER216 SEER Heating Input 9.3 kW Sensible cooling 24640 Btuh Heating output 31767 Btuh Latent cooling 10560 Btuh Temperature rise 25 OF Total cooling 35200 Btuh Actual air flow 1173 cfirn Actual air flow 1173 cfirn Airflowfactor 0.037 cfrn/Btuh Airflowfactor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved byACCA to meet all requirements of Manual J 6th Ed. _ � wrigl>ltsofC® 2022-Feb-1615:05:20 -�•^ ••^^-•e^^• Fiigk-Sule®Unvarse1202222.0.01 RSW8707 pa9e2 ACCA ...\QUICK1Do=erds\Wdghs ftWAC\SNOWERES..np Calc=MJ8 FrorADoorfaces: E Job #: Performed for; SNOWE RESIDENCE sheet 1 LIVING 164 7" 84 do — 6" BEDROOM 2 WHCEN DIN. 6' 148chn 84 dm ill. S4 drti� g„ L LIVNGONING 20 A 'MhDOM 1 14" ,278Rm LA Y 7 rfm QUICK CALCS, INC. 317 ST LUCIE LANE FT. PIERCE, FL 34946 Phone: 772-466-6799 QUICKCALCS@AOL.COM GMAIrtm Scale: 1 :135 Page 1 Right-SuiteC) Universal 2022 22,0.01 RSU08101 2022-Feb-16 15:05:44 ..s1Wr€ghtsoft HVACISNOWE RES..rup �- wrightsoW Duct System Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, Fr.PIERCE,fL 34946 Phane:772-466-6799 EmaII:QUICKCALCS@f OLCOM Project Information For: SNOWE RESIDENCE External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.343 / 0.157 in H2O 0.227 in/100ft 403 cfrn 221 Supply Branch Detail Table Job: Date: BY: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.343 / 0,157 in H2O 0.227 in/100ft 1173 cfm Name Design (Btuh) Htg (cfrn) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 499 22 23 0.227 4.0 Ox0 MFx 35.6 115.0 st1 BATH c 1739 33 81 0.312 5.0 Ox 0 VFx 14.8 95.0 BEDROOM3 c 1843 14 86 0.331 8.0 Ox 0 VFx 8.5 95.0 DEN c 2439 32 113 0,227 7.0 0x 0 VFx 36.1 115.0 st1 FORMAL LIVING-B c 5631 86 261 0.243 8.0 Ox 0 VFx 25.8 115.0 st1 FORMAL WING-C c 5631 86 261 0,255 8.01 OxO VFx 19.1 115.0 st1 FORMAL LIVING-D c 5631 86 261 0.236 9.01 OxO VFx 30.0 115.0 st1 HALLWAY c 1635 35 76 0,324 5.01 OxO VFx 10.8 95.0 WIG c 223 10 10 0,323 6,01 OxO VFx 11.0 95.0 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cim) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 PeakAVF 311 920 0.227 1172 12.0 0 x 0 VnlFlx Return Branch Detail Table Grille Htg Clg TEL Design Ueloc Diam H x W Stud/Joist Duct Name Size (in) (cfln) (cfin) (ft) FR (ipm) (in) (in) Opening (in) Matl Trunk rb4 Ox0 238 712 69A 0.227 1305 10.0 Ox 0 VFx rb2 Ox0 166 461 0 0 0 0 Ox 0 VFx edwnark vanes nave aeon mawanyovamdden _ -�i- wrightsofta zozz-Feb-rsts:os:2t ..•�•��• �•�_o w+ RI9�-Sule®Uriversa1202222.0.01 RSU06101 Pagel �� ..AOUICMDoamerAs\Wrigldsoft HUACISNOWE RES..np Caic=MJO Frord Doorfaces E -�- wrightsoW Duct System Summary Date: AHU 2 By. QUICK CALCS, INC. 317 ST. LUCIE LANE, Fr.PIERCE, EL 34946 Ptnne: 772-466-6799 Emaii: QUICKCALCS@/aOLCOM Project Information For: SNOWS RESIDENCE External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest fiction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.347 / 0.153 in H2O 0.214 in/100ft 1173 Gim 233 ft Supply Branch Detail Table Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.347 /0,153 in H2O 0.214 in/100ft 1173 cfm Name Design (Btuh) Htg (dm) Clg (dm) Design FR Diam (In) HxW (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (it) Trunk BATH c 1905 41 84 0.238 5.0 Ox0 V1Fx 30.6 115.0 st2 BEDROOM c 3435 90 151 0.227 7A Ox0 V1Fx 37.8 115.0 st2 BEDROOM2 c 3350 83 148 0.238 7.0 Ox0 VIFx 30.6 115.0 st2 GARAGE h 3286 268 145 0 0 Ox0 V Fx 0 0 KITHCENCIN. h 2247 84 67 0.227 TO Ox0 VIFx 38.2 115.0 st2 KITHCERDIN.-A h 2247 84 67 0.234 6.0 Ox0 VIFx 33.2 115.0 st2 LAUNDRY c 167 3 7 0.215 5.0 Ox0 V1Fx 46.3 115.0 st2 LIVING h 4114 154 113 0.224 6.0 Ox0 VIFx 40.0 115.0 st2 LNING-A h 4114 154 113 0.214 7.0 Ox0 VIFx 47.0 115.0 st2 LNNG/DINING-A c 6309 213 278 0,216 9.0 Ox0 VIFx 45.8 115.0 st2 Supply Trunk Detail Table Name Trunk Type Htg (dm) Clg (Gl m) Design FR Ueloc Opm) Diam (in) H x W (in) Dud Material Trunk s12 PeakAVF 905 1028 0.214 962 14.0 0 x 0 VInlFlx ed�Kearo camas name aeea n,ae�anr o�emaea� 2022-Feb-1615:05:21 ® � WPICJflY50fY® Ri9M SJle®Urivarsa1202222.0.01 RSW6101 Paget /�+� ...\QUICMDoameMs\WrigMsoli HVAC\SNOWE RES..M1Q Caic=MJB FrorA Door faces: E Grille Htg cig TEL Design Veloc Diann H x W Stud/Joist Duct Name Size (in) (cfm) (cfin) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox0 556 500 71.4 0.214 398 16.0 0x 0 MFx rb1 Ox0 617 673 0 0 0 0 Ox 0 MFx edcrnare �araes nape neap ma��anyo�emaae� _ '�' W�'IC]�1t501(Ge 2022-Feb-ifi 15:05:21 ...w�. ......o.�ry.n Rlgk-Suie®Urrversa1202222.0.01 RSW8101 Page3 �� ...\QUICMDoameiNs\WngMsoLL HVAC\SNOWE RES..np CaIc=M.IO Frort Doorraces: E