HomeMy WebLinkAboutProduct Approval Roofing UnderlaymentBCIS Home Log In User Registration Hol Tob,cs su M. urcharge a s ac u ica ion
db'Or
�,...(, ; `}' Product Approval
� USER: Public User
} Product Approval Menu > Product or App ication Search > Application List > Application Detail
9M'�t
„a;f�yq�Ak.�� FL # FL10626-R22
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany, NJ 07054
(800) 766-3411
mstieh@gaf.com
Authorized Signature Robert Nieminen
Ireith@nemoetc.com
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
Tech nicalQuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Roofing
Underlayments
ps ixl0to ,-gggsaca.
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
12/17/2021
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
i
Referenced Standard and Year (of Standard)
FL10626 R22 COI 2021 01 COI NIEMINEN pdf
Standard
Year
ASTM D1970
2015
ASTM D4533 (tear)
2015
ASTM D4798 (weathering)
2011
ASTM D4869 (water transmission)
2016
ASTM D5035 (tensile)
2011
ASTM D6164
2011
ASTM D6757
2016
FM 44.74
2011
FRSA/TRI, 6th Edition
2018
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
......._..__._
Model, Number or Name
10626.1
GAF Roof Underlayments for
use in FBC non-HVHZ
jurisdictions
1 Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
I Design Pressure: +N/A/-442.5
Other: 1.) The design pressure noted in,this
I application relates to one particular
underlayment system. Refer to ER Section S.8.3
for details. 2.) Refer to ER Section 5 for other
Limits of Use.
Method 1 Option D
06/09/2021
06/11/2021
06/17/2021
08/10/2021
12/16/2021
Description
Roofing Underlayments for use in sloped roof systems
Installation Instructions
FL10tiZ6_R2.2 II 2021 0¢ 09 FINAL ER (;AF UNDERLAYMENTS FL10626-
R22. pAff
Verified By: Robert Niemien 59166
Created by Independent Third Party: Yes
Evaluation Reports
FL10626 R22 AE 2021 06 09 FINAL ER GAF UNDERLAYMENTS FL10626-
R22.pdf
Created by Independent Third Party: Yes
Contact U :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 050.487.1395. -Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails
provided may be. used for official communication wit♦{ the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department wlln an email address which Fan be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
I Product Approval aAccepts:
riiqq'.: � 4=te
Credit Card
Safe
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
e .q.
GAF Evaluation Report 01505.04.08-R22
1Campus Drive FL10626-R22
Parsippany, NJ 07054 Date of Issuance: 04/25/2008
(800) 766-3411 Revision 22: 06/09/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida 'The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted
herein.
i
DESCRIPTION: GAF Roof Underlayments for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Reportlis valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility locations) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the; named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entirel Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E. • Cc. •'Tµ The facsimile seal appearing was authorized by Robert
t, Nieminen, P.E. on 08/09/2021. This does not serve as an
Florida Registration No.59166, Florida DCAANE1983
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or control,ed by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOIETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previdus versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC, LLC
ONEMO I etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: U nderlayment
Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the
following sections of the 71h Edition (2020) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
Section
Propert'u
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1507.1.1, 1507.2.4, 1507.2 9.2 /
Materialistandard
ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.1.1.1(2&3, Exception),
I ear Strength
ASTM D4533
201S
1507.1.1.1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
1507.1.1.1(2&3, Exception),
Tensile strength
ASTM D5035
2011 .
1507.1.1.1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
1507.1.1.1(5) / R905.1.1.1(5)
Liquid water transmission
ASTM D4869
2016
1507.1.1 / R905.1.1
IVlateriallstandard
ASTM D6757
2016
1507.3.3, R905.3.3
Material -standard
FRSA/TRI, Sixth Edition
2018
1507.11.2
IVlateriallstandard
ASTM D6164
2011
TAS 110
Accelerated Weathering
ASTM D4798
2011
Entity
Examination
Reference
Date
ERD (TST 6049)
ASTM D1623 & FRSA/TRI (Slippage)
G34150.08.11
11/14/2011
ERD (TST 6049)
ASTM D6164 (GA)
G40630.01.14-2B
01/07/2014
ERD (TST 6049)
ASTM D6164 (GA)
G46160.09.14-3A
09/09/2014
ERD (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-3
03/01/2017
ERD (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-4
03/01/2017
ERD (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-1
03/08/2017
ERD (TST6049)
(ASTM D1970 (IN)
GAF-SC16440.12.17
12/31/2017
Intertek (TST 1558)
ASTM D4869 (Dadra, India)
F8549.02-106-18
11/08/2016
NEMO (TST 6049)
Physical Properties (ON)
4q-GAF-I9-SSMBB-03.A
05/13/2019
NEMO (TST6049)
ASTM D1970
4j-FTS-20-SSUDL-01.A
12/01/2020
NEMO (TST 6049)
ASTM Dd798, TAS 103
4j-GAF-20-SSUDL-02.A
03/15/2021
NEMO (TST6049)
I ASTM D4798
4j-FTS-2I-SSUDL-02.A
06/09/2021
PRI (TST 5878)
ASTM D1970 (IN)
GAF-324-02-01
11/30/2011
PRI (TST 5878)
ASTM D226 (OK)
GAF-339-02-01
03/13/2012
PRI (TST 5878)
ASTM DIi798 (NC)
GAF-349-02-01
07/03/2012
PRI (TST 5878)
Wind Uplift
GAF-434-02-01
09/16/2013
PRI (TST 5878)
Wind Uplift
GAF-434-02-03
09/16/2013
PRI (TST 5878)
Wind Uplift
GAF-434-02-04
09/16/2013
PRI (TST 5878)
ASTM D4'533 (various)
GAF-818-02-01
12/05/2017
PRI (TST 5878)
ASTM D1970 (AL)
MSA-047-02-01
04/11/2018
PRI (TST 5878)
ASTM D4533 (LA)
GAF-826-02-01
06/4/2018
PRI (TST 5878)
ASTM D4533 (Dadra, India)
GAF-847-02-01
06/4/2018
PRI (TST 5878)
ASTM D4533 (Dadra, India)
GAF-914-02-01
04/10/2019
PRI (TST 5878)
ASTM D4533, D5035 (VA)
376TOO12
07/15/2019
PRI (TST 5878)
ASTM D4533 (Urnerkui Kilvani, India)
376T0018
07/31/2019
PRI (TST 5878)
ASTIVI 0d533 (Parzai, India)
376T0018
07/31/2019
NEMO ETC, LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization#32455 +I_I^t5-11C,NON- i:Vi•tiEVALUATION. F1.10626-1122
GAF Roof Underlayments Revision 22: 06/09/2021
Page 2 of 9
Entity
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
UL (TST 1740)
PRI (TST 5878)
PRI (TST 5878)
UL (TST 1740)
NEMO ETC
NEMO
UL, LLC (QUA 9625)
UL, LLC (QUA 9625)
UL, LLC (QUA 9625)
ExaI mination
ASTM D11970(AR)
ASIM D226 (S-CA)
AS IM D4533 (Gujarat, India)
ASTM D5035 (various)
ASTM D4533, D5035 (Rajasthan, India)
ASTM D4533, D5035 (Gujarat, India)
ASTM D6757 (TX)
ASTM D5035 (Gujarat, India)
ASTM D4533, D5035 (Rajasthan, India)
ASTM D6757 (NC)
traceability
Iraceabiility
Quality Control
Quality Control
Quality Control
ONEMO I etc.
Reference
376T0032
376TOO54
376TOO58
376TO103
376TO111
376TO113
02NK22569
376TO146
376TO161
IONK11990
FBC Cross -Listing
FBC Cross -Listing
Service Confirmation
Service Confirmation (AL)
Florida BCIS
Date
10/22/2019
02/18/2020
02/18/2020
09/11/2020
12/22/2020
12/22/2020
06/04/2002
03/11/2021
05/07/2021
05/18/2011
04/22/2020
04/08/2021
03/23/2021
05/04/2020
Current
•oe P. c
Plant(s)
Product
Material Standard
GAF Extended Dry -In Membrane
ASTM D1970
Langley, BC Canada
Liberty"" SBS Self -Adhering Base/Ply
Mt. Vernon, IN
4.27
Sheet
ASTM D1970
Savannah, GA
Mt. Vernon, IN
4.3
StormGuard' Film -Surfaced Leak Barrier
ASTM D1970
Savannah, GA
Arkadelphia, AR
4.4
WeatherWatch" Mineral -Surfaced Leak
ASTM D1970
Mt. Vernon, IN
Barrier
Savannah, GA
Tuscaloosa, AL
4.5
Deck -Armor`"" Premium Breathable Roof
1507.1.1.1(2&3, Exception) /
Dadra, India
Deck Protection
) R905.1.1.1(2&3, Exception)
i
Dadra, India
FeltBuster'" Synthetic Roofing Felt
1507.1.1.1(2&3, Exception),
Gujarat, India
(CPP) Rajasthan, India
4.6
(formerly FeltBuster-High-rroction Synthetic
1507.1.1.1(5) / R905.1.1.1(2&3,
(MIP) Rajasthan, India
Roofing Felt)
Exception), R905.1.1.1(5)
Richmond, VA
Spartanburg, SC
I ASTM D226, Type II (Table 1)
Pryor, OK
Shaffer, CA
4.7
Shingle -Mate" Root Deck Protection
4.8
StormSafe'"' Anchor Sheet
1507.9..1.1(2&3, Exception) /
North Bay, ON
R905.1.1.1(2&3, Exception)
Dadra, India
Tiger PaW'"" Premium Roof Deck
I 1507.1.1.1(2&3, Exception) /
Gujarat, India
4.9
Protection (formerly Tiger Paw"' Roof Deck
I R905.1.1.1(2&3, Exception)
Parzai, India
Protection)
Umerkui Kilvani, India
4.10
VersaShield') Fire -Resistant Roof Deck
i ASTM D6757
Conover, NC
Protection
4.11
Ruberoid' Mop Granule
ASTM D6164
Savannah, GA
FRSA/TR109-18
ASTM D6164
4.12
Ruberoid' Mop Giantik� FR i
Savannah, GA
FRSA/TR109-18
I
NEMO ETC, LLC I Evaluation Report 01506.04.08-R22
Certificote afAuthorization 1132455 1101�l t2Ll2i)) F.0 fi4N I` H?. EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22: 06/09/2021
Page 3 of 9
ONEMO I etc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use ihi FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If no listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section:
1507.2
1507.3
1507.4 and 1507.5
1507.7
1507.8 and 1507.9
Clay and Concrete Tile
Metal
Slate or
Wood
Underlayment
Asphalt
MechanicalSlate-Type
Adhesive-
Shingles
Attach
Set
panels
Shingles
Shingles
Shingles
Shakes
Yes
Yes
GAF Extended Dry -In Membrane
I Yes
No
No
Yes
Yes
Yes
(iointstrips,
aointstrips,
1507.1.1.3 /
1507.1.1.3 /
R905.1.1.3)
R905.1.1.31
Yes
Yes
Liberty'" 5855elf-Adhering i Yes
No
No
No
No
No
(joint strips,
(lolntstrips,
Base/Ply Sheet
I
1507.1.1.3/
1507.1.1.3/
R905.1.1.3)
R905.1.1.3)
Yes
Yes
StormGuard19 Film -Surfaced Leal:
Yes
No
No
Yes
Yes
Yes
Barrier
1507.1t13/
1)507.11.3/
R905.1.1.3)
R905.1.1.31
Yes
Yes
WeatherWatch" Mineral-SurfacedUoint
Yes
o
No
No
No
No
Leak Barrier
1507.1.1.3strips,
1507.1.1.3 /
1507..1.strips,
1507.1.1.3 /
I
R905.1.1.3)
R905.1.1.31
Deck -Armor'" Premium Breathable
Yes
No
No
Yes
Yes
Yes
No
No
Roof Deck Protection
FeltBuster" Synthetic Roofing Felt Yes
No
No
No
No
No
No
No
Shingle-Matep1 Roof Deck
Yes
No
No
No
No
No
No
No
Protection
Tiger Paw" Premium Roof Deck
Yes
No
No
Yes
Yes
Yes
No
No
Protection
VersaShield° Fire -Resistant Roof
Yes
No
No
No
No
No
No
No
Deck Protection
Yes
Yeseel
Ruberoid" Mop Granule No !
)ca)shrr in
I
Cap in
( 5hNo
No
No
No
No
2-ply system)
2-ply; Blom)
�
Sec 5.6.1 �
Ruberoidp' Mop Granule FR No
�s
(Cap sheet in
L
Yes
(Cap Sheet)
No
No
No
No
No
---- -----�._----
2-ply system)
-
2-ply system)
See 5.6.1
NEMO ETC, LLC
Certificote of Authorization 1132455
I
i
• ,� 1BC r1014••;Svt-tZ EVALUATION
GAF Roof Underlayments
Evaluation Report 01506.04.08-R22
FL10626-R22
Revision 22: 06/09/2021
Page 4 of 9
ONEMOjetc.
5.6.1 Adhesive -set is limited to use of tollowing underlayment / tile-adnesive comoinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS' i
Underlayment Adhesive Florida Product Approval
Ruberoid° Mop Granule; Ruberoid" Mop Granule FR Dupont "Tile Bond'"' Roof Tile Adhesive" FL22525
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Primer
Substrates
GAF Extended Dry -In Membrane
self -adhering
None
plywood
Liberty'" SBS Self -Adhering Base/Ply Sheet i _
self -adhering
(Optional)
ASTM D41
plywood
StormGuard' Film -Surfaced Leak Barrier
Weather Watch" Mineral -Surfaced Leak Barrier
Liberty'" SBS Self -Adhering Base/Ply Sheet
self -adhering
None
ASTM D226 felt, Type II
StormGuard" Film -Surfaced Leak Barrier I
Weather WatchQ° Mineral -Surfaced Leak Barrier
Liberty'" SBS Self -Adhering Base/Ply Sheet I
self -adhering
ASTM D41
metal (flashing metal, valley metal,
etc.)
StormGuar0'' Film -Surfaced Leak Barrier I
--
Weather Watch"(Mineral-Surfaced Leak Barrier
Ruberoid' Mop Granule
hot asphalt
ASTM D41
structural concrete
Ruberoid' Mop Granule FR
Ruberoid' Mop Granule
-----------------------,---
Ruberoid Mop Granule FR
hot asphalt
None
GAFGLAS° #80 Ultima'"' Base Sheet
or Ruberoid' 20 Smooth
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1. r
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but -- for mechanically attached base sheets - not less than:
• FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1 (for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck: i
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay�Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Refer to Tile Manufacturer's or Adhesive Monufo turer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization#32455 "%:C. lt:�d;;,!)7.rr! 0 N0114-1?'•%;♦_GVALUAt'EC7N FL10626-R22
GAF Roof Underlayments Revision 22: 06/09/2021
Page 5 of 9
i
ONEMOletc.
#1 Maximum Design Pressure = -442.5 psf.
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction i
Base Sheet: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4,
Tri-Ply Ply 4 or GAFGLAS; Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20
to 25 Ibs/square.
Cap Sheet: Ruberoid° Mop Granule; or Ruberoid° Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Cla�l Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section
2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
#2 Maximum Design Pressure = -45 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS" #80 Ultima"! Base Sheet or Ruberoid° 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c.
at the min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center rows
in the field of the sheet.,
Cap Sheet: Ruberoid" Mop Granule jor Ruberoid" Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
#3 Maximum Design Pressure = -75 psf.
Deck: Min. '19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS" #80 Ultima'" Base Sheet or Ruberoid" 20 Smooth mechanically attached with 12 ga.,
ruin. 1.25-inch long ring $hank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c.
at the min. 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid" Mop Granule for Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure = -97.5 psf.
Deck: Min. 19/32-inch . plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS' #80 Ultirna- Base Sheet or Ruberoid' 20 Smooth mechanically attached with 11 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c.
at the min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field
of the sheet.
Cap Sheet: Ruberoid° Mop Granule or Ruberoid" Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 2.0 to 25 Ibs/square.
NEMO ETC, LLC Evaluation Report 01506.04.08-1122
Certificate ofAuthorizotiou #32455 °'G,1 @ALUM ON F1.10626-1122
GAF Roof Underlayments Revision 22: 06/09/2022
Page 6 of 9
ONEMOletc.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Prepared Roof Cover
Maximum
Underlayment
Installation Type
Exposure
(days)
Deck -Armor`" Premium Breathable Roof Deck Protection, FeltBuster'"" Synthetic
Roofing Felt, Shingle -Mate" Roof Deck Protection, StormSafe'°" Anchor Sheet, Tiger
Paw'" Premium Roof Deck Protection, VersaShield® Fire -Resistant Roof Deck
Mechanically attached
30
Protection, Liberty'"' SBS Self -Adhering Base/Ply Sheet, StormGuardm Film -Surfaced
Leak Barrier and WeatherWatch'°` Mineral -Surfaced Leak Barrier
Mechanically attached
180
GAF Extended Dry -In Membrane
Ruberoid® Mop Granule and Ruberoid°° Mop Granule FR
Adhesive -set tile roof system
180
Mechanically attached
UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPA E LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Staging Slope
_
Ruberoid® Mop Granule
_
Flat
Max. 10-tile stack
4:12
Flat
Max. 6-tile stack (4 over 2)
5:12
Lugged
Max. 10-tile stack
5:12
Ruberoid°' Mop Granule FR
Flat or Lugged
Max. 6-tile stack (4 over 2)
5:12
Lugged
Max. 10-tile stack
4:12
6.1 GAF Roof Underlayrnents shall be installed in accordance with GAF published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panols, adld check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to apblication and prime the substrate (if applicable).
6.3 Deck -Armor"' Premium Breathable RoPf Deck Protection or Tiger Paw'"' Premium Roof Deck Protection:
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception)
or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type
of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.4 FeltBusterTM Synthetic Roofing Felt:
6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception),
1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
NEMO ETC, LLC i Evaluation Report 01506.04.08-1122
Certificate of Authorization #32455 F. iN"::t)I , ;2,.)2C,I FISC NON-14Lr14Z I VALUATION FL10626-R22
GAF Roof Underlayments Revision 22: 06/09/2021
1 Page 7 of 9
1 6.5 1 StormSafeT- Anchor Sheet: I
6.5.1 StormSafe'" Anchor Sheet is limited toi use as a mechanically attached base layer in 2-ply underlayment systems.
6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception)
or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type
of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.5.3 One the same day, install Liberty" SBS Self -Adhering Base/Ply; StormGuard" Film -Surfaced Leak Barrier or
WeatherWatch"" IVlineraI-Surfaced Leak Barrier over the StormSafe'"' Anchor Sheet.
6.6 Shingle -Mate° Roof Deck Protection:
6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.7 VersaShield" Fire -Resistant Roof Deck Protection:
6.7.1 Shall be installed in compliance with requirements for an approved' mechanically attached underlayment (ASTM
D6757) in FBC Table 1507.1.1.1 or FBCI Residential Table R905.1.1.1 for the type of prepared roof covering to be
installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.8 GAF Extended Dry -in Membrane, Libe'rty'"" SBS Self -Adhering Base/Ply Sheet, StormGuard" Film -Surfaced Leak,'
Barrier or WeatherWatch" Mineral -Surfaced Leak Barrier:
6.8.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment IA.') i Ivl ulyiu) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
6.8.2 Back -nailing is required. Back -nailing shall consist of Approved cap nails spaced 18-inch o.c., encapsulated within
min. 4-inch side laps.
6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or 11905.1.1.
6.8.4 GAF Extended Dry -in Membrane, Libeky'" SIBS Self -Adhering Base/Ply Sheet, StormGuard" Film -Surfaced Leak
Barrier or WeatherWatch" Mineral -Surfaced Leak Barrier may be installed as a secondary water barrier using
minimum 4--inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system.
6.9 Ruberoid" Mop Granule; Ruberoid" Mop Granule FIR:
6.9.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the
"Two Ply System" in the FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition, and the manufacturer's installation instructions.
6.9.2 Refer to Section 5.8 herein for attachnIent limitations.
6.9.3 Refer to Table 4 for tile staging limitations.
I
I
NEMO ETC, LLC i Evaluation Report 01506.04.08-R22
Certificate of Aulhorirarion #324.55 . V h i.! kd' t')P l FL10626-R22
GAF Roof Underlayments Revision 22: 06/09/2021
Page 8 of 9
i
ONEMOjetc.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL, LLC. — QUA9625; (414) 248-6409; karen.buchmann@ul.com
-!END OF EVALUATION REPORT -
NEMO ETC, LLC i Evaluation Report 01506.04.08-1122
CertiftcateofAuthorization #32455 ""cC'.`:fitd t20::f)i e"ti WON-N-JE1Z EVALUA NON FL10626-1122
GAF Roof Underlayments Revision 22: 06/09/2021
! Page 9 of 9
4 V]�
,7�Yaii!.�
i%X° �-.. •_'�,c.`'�r .,Lr`:
6 NnjaE' .t�n6i(�aifni+� o{i�;�Sn.,4��n2+3�:
13CIS Home Log In User Registration if
Topics
Hotl 1
Submit Surcharge Stats & Facts
Publications Contact Us SCIS Site Map Links
FloI.
x: Product Approval
',
USER:'�
Product Apploval Menu > Product or Ap lication Search > Ap lication List > Application Detail
y�i oryirl�c
.(
Application •'
Revision
•d' Version
2020
Application Status
Approved
Comments
Archived
i
Product Manufacturer
Owens Corning
Address/Phone/Email
One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg. keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
1
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert I.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/01/2099
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
i
Sections from the Code
FL10674 R16 COI 2020 01 COI NIEMINEN.pdf
Standard
ASTM D1970
ASTM D3161
ASTM D3462
ASTM D7158
Year
2015
2016
2010
2019
Product Approval Method Method 1 Option D
Date Submitted
12/11/2020
Date Validated
12/17/2020
Date Pending FBC Approval
12/26/2020
Date Approved
02/09/2021
Summary of Products
FL #
Model, Number or Name
Description
10674.1
Owens Corning I Asphalt Roofing
3-tab, 4-tab, laminated, starter and hip & ridge shingles
Shingles and Starters
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10674 R16 II 2020 12 it FINAL ER OC ASPHALT
SHINGLES FL10674-R16.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert J. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10674 R16 AE 2020 12 11 FINAL ER OC ASPHALT
SHINGLES FL10674-R16.pdf
Created by Independent Third Party: Yes
hack RIflXY
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
1
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statemen
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send eleca
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.:
Florida Statutes, effective October 1, 2012, licenseesl licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, I
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click